home *** CD-ROM | disk | FTP | other *** search
/ TAP YIPL / TAP_and_YIPL_Collection_CD.iso / PHREAK / CELLULAR / GEMINI.TXT < prev    next >
Encoding:
Text File  |  2000-01-07  |  2.5 KB  |  85 lines

  1. GE/Ericsson Mini Convertible and versamobile packages.
  2.  info provided by Magic Thighs
  3.  
  4. CPU: M50747-000P 8K * 8 ROM   256 * 8 RAM
  5.  
  6. Memory: 32K * 8 CMOS EPROM
  7. 2K * 8 CMOS RAM battery backed up, NAM included
  8. SNM (Serial Number Memory) 64 * 1 CMOS EPROM'
  9.  
  10. TEST MODE:
  11. 1. Power on with [FCN/0]
  12. 2. Depress [CL] continuously
  13. 3. Enter 1414213 within 10 sec after power on, then release [CL]
  14. 4. 'INUSE' goes on. Now ready to accept the following commands,
  15.    followed by [SEND].
  16.  01 tx on
  17.  02 tx off
  18.  03 rx unmute
  19.  04 rx mute
  20.  05 tx unmute
  21.  06 tx mute
  22.  07 st on
  23.  08 st off
  24.  09 high tone on
  25.  10 high tone off
  26.  11 low tone on
  27.  12 low tone off
  28.  13 vehicular charger conversation mode on
  29.  14 "" off
  30.  16 compander on
  31.  17 compander off
  32.  2n connect DTMF to the modular (DTMF digit =n)
  33.  30 Disconnect DTMF
  34.  8n SAT on (n=SAT)
  35.  90 to 97 attenuator control, when the portable user together with booster,
  36.    act as power control
  37.  
  38.  nnn then [END] set channel
  39.  [RCL] rotate synth 001-333-666-001 ch etc.
  40.  [MUTE] indicate current RSSI level.
  41.  
  42. when connected to the test adaprtor and field tester, auto test is available
  43.  by means of serial interface. the test command reperatory is written in
  44. the AMPS specification 5.3.5. in addition, the following are new commands:
  45.  44 compander on (60,0,0)
  46.  45 compander off (21,0,0)
  47. the test adapter can convert serial data from the station into parallel 8-bit
  48. AMPS bus data and parallel 8-bit AMPS bus data from the Field tester into
  49. serial data.
  50.  
  51.  
  52.  
  53. Self check error codes: each time the fone is turned on, it performs a self-
  54. check and returns an error code if a problem.
  55.  Err 1 program memory checksum incorrect
  56.  Err 2 SNM checksum is incorrect
  57.  Err 3 NAM checksum is incorrect
  58.  Err 4 synthesizer did not achieve lock
  59.  Err 5 RF power status did did not indicate an on condition.
  60.  
  61.  
  62. NAM programming procudure:
  63.  
  64. 1. press [END/FCN] and [0] keys for 1 second or more to turn on radio.
  65. 2. within 10 seconds, press and hold [CL] key while entering 7591122
  66. 3. release [CL]
  67. 4. change any information neccessary with the keypad, press [SEND] to
  68.  move from setting to setting.
  69.  feature     values
  70.   ------     ------
  71.  
  72.    MIN        10d
  73.    unlock      000-999
  74.    sid        00000-32767
  75.    LU          0-1                local use
  76.    MIN MARK    0-1
  77.    IPCH        001-666
  78.    ACCOLC      00-15
  79.    PS          0-1                 preferred system 1=a 0=b
  80.    GIM         00-15
  81.    EE          0-1                 1=end to end signaling
  82.    BOOSTER     0-1
  83.    AR          0-1                  1=autonomous registration
  84.  
  85.