2 Failed to connect to the NPP interface, error: %X\n\n
3 Failed to start capturing, error: %X\n\n
4 (Hit space to stop) Percent Complete: %d%%
5 Total frames captured: %d\n\n
6 Capture file name: %s\n\n
7 Could not locate the temporary capture file:\n %s\n\n
8 Error creating path, could not move:\n %s\n
9 To: %s\n\n
10 Unable to move capture file from:\n %s\n
11 No frames were captured, no capture file generated\n Make sure you are capturing on the correct interface\n and/or the capture filter is not too restrictive\n See Help "/?" for more information on NIC index numbers\n\n
15 The buffer size given is too small, the minimum is: %d\n\n
16 The buffer size given is too large, the maximum is: %d\n\n
17 The network index number given is too large\n\n
18 The network index number given is too small\n\n
19 Failed to set the Buffer size\n
20 Error code: %X\n\n
21 Failed to set Local Only mode\n
22 Failed to set Trigger\n
23 Unable to load the Capture Filter file: %s\n
24 %s is not a valid Network Monitor 2.x Capture Filter file\n\n
25 Invalid ETYPE or SAP value\n
26 Make sure you are using a valid Network Monitor 2.x Capture Filter File\n\n
27 Invalid Address Expression\n
28 Invalid Pattern Match\n
29 The RPC service is not installed or not started\n
30 Could not configure the Network Monitor driver\n\n
31 Access Denied, you must be an Administrator on %s to run this program\n
32 Could not find a Network Monitor interface, make sure the Network Monitor driver is installed\n
33 You have been prevented from capturing by %s(%02X%02X%02X%02X%02X%02X):%s\n\n
38 /B:# - Buffer, capture size to take, from %dMB to %dMB default is 1Mb\n\n
39 /T - Trigger, stop capturing when the given buffer and/or pattern is reached\n If no trigger is given, the capture will stop when the buffer is full\n Use "/T N" to continue capturing even if the buffer fills\n Oldest frames in capture will be over written once the buffer is full\n Note: With "/T N" you will have to hit space bar to stop capturing\n\n
44 <HexOffset> - Hex Offset from start of frame used with P, BP, PB (NOT B)\n\n
45 <HexPattern>- Hex Pattern to match used with P, BP, PB (NOT B)\n
46 The Pattern must be an even number of hex digits\n\n
47 /C:<Capture File> - Move temporary capture to full path and/or file name\n This can be any valid local or remote path\n If "/C" is not specified the capture file will remain\n in the default temporary capture folder\n\n
48 /F:<filterfile.cf>- A Network Monitor 2.x generated capture filter (*.cf)\n\n
49 /L:<HH:MM:SS> - Capture for given amount of time (max 99:99:99)\n
50 Note: This option overrides the default 100%% trigger\n
51 unless "/T <trigger type>" is also specified\n\n
52 /N:<#> - NIC Index number
53 , for "%s\n\n"
54 , for this computer\n\n
55 Use the following index numbers for these adapters:\n
56 %d = %s (%02X%02X%02X%02X%02X%02X)
57 (Loop Back)
58 (default)
59 Unknown argument: %s.\n\n
60 Multiple buffer sizes specified.\n\n
61 Multiple networks specified (you may only specify one).\n\n
62 Capture file path too long, maximum: %d\n\n
63 "%c" is not a valid character for a path\n\n
64 Invalid Capture File, you must at least specify a path\n\n"
65 Capture Filter path must be less than %d characters long\n\n
66 Invalid Capture Filter, must have .cf extension\n\n
67 Unknown argument: %s.\n\n
68 %s is an invalid time, format should be HH:MM:SS\n\n
69 %s is too large, maximum is 99:99:99\n\n
70 Unknown Trigger type %s\n\n
71 Missing Buffer Size for Buffer Trigger\n\n
72 You must specify a Hex Offset and Pattern for Pattern Trigger\n\n
73 Missing Pattern for Trigger\n\n
74 Missing Buffer Size for Pattern then Buffer Trigger\n\n
76 No Pattern was given for /T P switch, found %s\n\n
77 Trigger Pattern is too long, maximum is 16 bytes\n\n
78 Trigger Pattern must have an even length\n\n
79 Example 1e2a01 not 1e2a1 \n\n
80 %s is not a valid Hex value for a Trigger Pattern
81 No Offset or Pattern was given for /T P switch, should be before %s\n\n
82 Trigger Hex Offset is too large, make sure you did not swap Offset and Pattern\n\n
83 %s is not a valid Hex value for the Trigger Offset\n\n
84 Missing Buffer size, should be before %s\n\n
85 Buffer must be 25, 50, 75, or 100 found: %s.\n\n
86 WAN (PPP/SLIP) Interface
87
88 Unknown interface name
89 Not enough free disk space to create the capture file in your temporary folder\n Free up space on the drive or change the temporary folder with the /tcf: switch\n\n
90 This program can only run on Windows 2000 and later\n\n
91 You have specified an invalid temporary capture folder, see help "/?"\n\n
92 You have specified a temporary capture folder that exceeds the maximum length of %d\n\n
93 Temporary Capture drive must be a fixed local disk\n See help "/?" for more information on the "/TCF:" switch\n\n
94 An error occurred writing to the registry, make sure your temporary capture path is correct\n\n
95 An error occurred while trying to create the temporary capture folder\n Try changing the temporary capture folder with the "/TCF:" switch see help "/?" for more information\n\n
96 No default temporary capture folder was set, you must specify a new one\n Use the "/TCF:" switch to set a new folder see help for more information\n\n
97 /TCF:<Folder Name>- Permanently changes the temporary capture folder\n Warning the path must be on a fixed local hard drive\n Once set you only need to use the switch again\n to change the directory\n\n
98 An error connecting to the remote computer, make sure the share exists and check your permissions\n\n
99 Could not create: %s\n
100 Could not convert the capture file name to local language code page\n Try using a new temporary capture path ("/TFC:")\n\n
101 Failed to Set Special blob tag\n
102 This computer does not support remote operations you must have the\n Remote NPP installed (RMTNPP.DLL) that ships with NetMon Full\n
103 Failed to set Remote blob tag\n
104 /A - Capture all traffic (P-Mode), default is local only\n\n
105 /R:<Remote Name> - Name of remote computer you would like to capture from\n This option requires Network Monitor Full (SMS)\n to be installed on the system\n\n
106 Could not convert the remote computer name into a non Unicode name\n that the Network Monitor driver can understand
107 The computer name you specified is to long, maximum is: %d\n\n
108 "%c" is not a valid character in a computer name\n\n
109 Error: %s\n
110 The Buffer Size is invalid, Buffer Size must be between %dMB and %dMB\n\n
111 You did not specify a capture time with the "/L:" switch\n\n
112 Microsoft
113 Windows NT
114 Windows 2000
115 Windows Whistler
116 Network Monitor Capture Utility (NetCap)
117 Installing the Network Monitor dirver
118 Could not install the Network Monitor driver.\n Close any open instances of "Network and Dial-up Connections"\n and run NetCap.exe again. If you continue to get this error message\n try restarting your computer or install the driver manually.\n\n
119 Removing the Network Monitor driver
120 Could not remove the Network Monitor driver\n Close any open instances of "Network and Dial-up Connections"\n and run NetCap.exe /Remove again. If you continue to get this error message\n try restarting your computer or remove the driver manually.\n\n
121 /Remove - Removes the NetCap instance of the Network Monitor driver\n\n
122 The NetCap.exe instance of the Network Monitor driver successfully removed.\n\n
123 No instances of the Network Monitor driver installed by Netcap.exe were found.\n\n
124 You specified an invalid network Index number.\n Make sure you selected the correct Index number\n and the Network Monitor Driver is enabled on it.\n