home *** CD-ROM | disk | FTP | other *** search
/ Soft 19 / Soft19.iso / win95-rc / win95_04.cab / network.txt < prev    next >
Text File  |  1996-08-01  |  23KB  |  566 lines

  1.        -----------------------------------------------------------
  2.                     Microsoft Windows 95 README for Networks
  3.                                    August 1996
  4.        -----------------------------------------------------------
  5.  
  6.                     (c) Copyright Microsoft Corporation, 1996
  7.  
  8.  
  9. This document provides complementary or late-breaking information 
  10. to supplement the Microsoft Windows 95 documentation.
  11.  
  12.  
  13. HOW TO USE THIS DOCUMENT
  14. ========================
  15.  
  16. To view Networks.txt on screen in Notepad, maximize the Notepad window.
  17.  
  18. To print Networks.txt, open it in Notepad or another word processor,
  19. and then use the Print command on the File menu.
  20.  
  21.  
  22. CONTENTS
  23. ========
  24.  
  25. CLIENT FOR NETWARE
  26.   Windows 95 and NetWare 3.12 and 4.01 Servers
  27.   Opening Files on NetWare 3.11 Servers
  28.   Lowercase Extended-Character Passwords on NetWare 4.1 Servers
  29.   Client for NetWare and Programs That Use External Files
  30.   Novell NetWare Login Scripts
  31.   Installing Novell Client32 Overwrites 
  32.     NetWare Directory Services Files
  33.   Upgrading Over an Earlier Beta Version of Windows
  34.   Printing to NetWare Directory Services Printers
  35. PLUG AND PLAY NETWORK CARDS AND 16-BIT REAL-MODE DRIVERS
  36. INTEL ETHEREXPRESS 16 NICs AND PCI COMPUTERS
  37. WINDOWS FOR WORKGROUP SHARES
  38. RUNNING WINDOWS 95 FROM A SERVER
  39.   To Install Windows 95 over Previous Builds
  40. SUPPORT FOR THIRD-PARTY NETWORKS
  41.   LANDESK 2.0
  42.   SunSelect PC-NFS
  43.   Banyan VINES
  44.   DEC Pathworks
  45.   Artisoft LANtastic
  46. PRINTING TO A NETWORK PRINTER
  47. PROBLEMS PRINTING TO POSTSCRIPT PRINTERS OVER A NETWARE NETWORK
  48. ISSUES AND INSTALLATION OF MS-DLC WITH WINDOWS 95
  49. MICROSOFT TCP/IP PROTOCOL
  50. USER PROFILES OVER THE NETWORK
  51. NETWORK BACKUP AGENTS
  52.   Arcada Backup Exec Network Backup Agent
  53.   Cheyenne ARCserve Network Backup Agent
  54. REAL-MODE PROTOCOLS: WARNING ICONS ON YOUR NETWORK ADAPTER
  55. USING AN IBM THINKPAD WITH A DOCK II
  56. INTEL ETHEREXPRESS PRO /100B CARD NOT CORRECTLY DETECTED
  57. SETTING UP A WINS SERVER
  58.  
  59.  
  60. CLIENT FOR NETWARE
  61. ==================
  62.  
  63. Windows 95 and NetWare 3.12 and 4.01 Servers
  64. --------------------------------------------
  65. Windows 95 with Microsoft Client for NetWare can experience 
  66. problems with NetWare 3.12 and 4.01 servers if packet burst is 
  67. turned on. This is a known problem with these servers that Novell 
  68. has fixed and posted on their forums. Download the file Pburst.exe 
  69. from the Novell NetWare Forum on Compuserve or the Novell Web site 
  70. (Ftp.Novell.com). 
  71.  
  72. Pburst.exe contains the patch for the affected servers.
  73.  
  74. Opening Files on NetWare 3.11 Servers
  75. -------------------------------------
  76. Programs that open a large number of files consecutively in rapid
  77. succession might have occasional problems opening files on NetWare 3.11 
  78. servers. This can also happen when opening a file in a folder for which
  79. you do not have file scan rights, such as an MS Mail shared post office.
  80.  
  81. Possible error messages:
  82.  
  83. - "File not found" error on a file you know exists
  84. - "Sharing violation" or "Lock violation" error
  85. - "Unable to open file" error
  86. - "File in use" error
  87.  
  88. There are two solutions to these problems:
  89.  
  90. - Obtain a patch file from Novell for the NetWare 3.11 server. Using 
  91.   FTP, connect to ftp.novell.com. Go to /pub/netware/nwos/nw311/osnlm 
  92.   and run 311ptd.exe. This program will extract the file os2opnfx.nlm. 
  93.   Then, load the .nlm file onto the NetWare 3.11 server. 
  94.   ("load os2opnfx.nlm")
  95.  
  96. - Disable long filename support in Client for NetWare. This means that 
  97.   you will not be able to use long filenames on any NetWare servers 
  98.   from Windows 95. To disable long-filename support, carry out the 
  99.   following steps:
  100.  
  101.   1. Click the Start menu, click Run, and then type Regedit.
  102.   2. Go to 
  103.      HKEY_Local_Machine\System\CurrentControlSet\Services\VxD\NWRedir
  104.   3. Create a new binary value named supportLFN with a value of 0.
  105.  
  106. Lowercase Extended-Character Passwords on NetWare 4.1 Servers
  107. -------------------------------------------------------------
  108. In a NetWare 4.1 environment, Client for NetWare does not support 
  109. passwords that use certain lowercase extended characters. Users 
  110. need to change their password to all uppercase characters.
  111.  
  112. Client for NetWare and Programs That Use External Files
  113. -------------------------------------------------------
  114. If you are using Microsoft Client for NetWare, and you run a program 
  115. that needs to access an auxiliary file, your program will have problems 
  116. if the auxiliary file is on a drive other than the one the program is 
  117. on. This is because only the current drive is searched for auxiliary 
  118. files; the search path is not searched. If you experience this problem, 
  119. make sure the program and any auxiliary files are on the same drive.
  120.  
  121. Novell NetWare Login Scripts
  122. ----------------------------
  123. The Login Script Processor for the Microsoft Client for NetWare should
  124. correctly process all commands in your login scripts. However, you 
  125. cannot load memory-resident programs (TSRs) from these scripts. 
  126.  
  127. Installing Novell Client32 Overwrites 
  128. NetWare Directory Services Files
  129. -------------------------------------
  130. When you install Novell Client32, the Novell setup program replaces 
  131. the Microsoft file Netdef.inf and renames it Netdef.bnw, and deletes 
  132. the NDS setup file Nwnds.dll. The result is that after uninstalling 
  133. Novell Client32, Service for NetWare Directory Services will not 
  134. install.
  135.  
  136. To work around this problem, carry out the following steps:
  137.  
  138. 1. Find the file Netdef.bnw and rename it Netdef.inf.
  139.  
  140. 2. Copy the Nwnds.dll file to the Windows\System directory on your 
  141.    your hard disk by carrying out the following procedure:
  142.  
  143.    1. Insert your Windows 95 installation CD into the CD-ROM drive.
  144.    2. Open an MS-DOS window.
  145.    3. Change to the Win95 directory on your CD-ROM, and then type the 
  146.       following at the command prompt:
  147.  
  148.       extract /l c:\windows\system precopy2.cab nwnds.dll
  149.  
  150. Upgrading Over an Earlier Beta Version of Windows
  151. -------------------------------------------------
  152. If you upgrade this release of Windows over an earlier beta release, 
  153. and you have Service for NetWare Directory Services installed, you 
  154. will be prompted about version conflicts for the following files:
  155.  
  156. - Nwnp32.dll (v. 4.0.969)
  157. - Nwlsproc.exe (v. 4.0.968)
  158. - Netware.tmp (v. 4.0.968)
  159.  
  160. When you see the version conflict prompt, click No. After Windows is 
  161. installed, you need to reinstall Service for NetWare Directory Services. 
  162. To do this, carry out the following steps:
  163.  
  164. 1. In Control Panel, double-click the Network icon.
  165. 2. Click Add, click Service, and then click Add.
  166. 3. Follow the instructions on your screen.
  167.  
  168. Printing to NetWare Directory Services Printers
  169. -----------------------------------------------
  170. You cannot install Client for NetWare Networks and Service for NetWare 
  171. Directory Services (NDS) during the same installation session. If you 
  172. do, your NDS printers will appear to be offline.
  173.  
  174. If your printers appear to be offline, try carrying out the following 
  175. steps:
  176.  
  177. 1. In Control Panel, double-click the Network icon.
  178. 2. Remove both Client for NetWare Networks and Service for NDS.
  179. 3. Restart your computer.
  180. 4. In Control Panel, double-click the Network icon.
  181. 5. Add Service for NDS.
  182. 6. Restart your computer.
  183.  
  184. NOTE:
  185. If your local area network is using NetWare 4.1 or later, there is no 
  186. need to install Client for NetWare Networks separately. When you install 
  187. Service for NDS, it also installs the Client for NetWare Networks.
  188.  
  189.  
  190. PLUG AND PLAY NETWORK CARDS AND 16-BIT REAL-MODE DRIVERS
  191. ========================================================
  192.  
  193. When you run the 16-bit real-mode driver for your Plug and Play 
  194. network interface card (NIC), your Plug and Play card might appear 
  195. not to function.
  196.  
  197. The reason the card appears to malfunction is that on most computers, 
  198. the Plug and Play card is inactive until Windows 95 enables it. 16-bit 
  199. NIC drivers load before Windows 95 can turn on Plug and Play cards. 
  200. Some 16-bit NIC drivers do not recognize Plug and Play cards (most 
  201. NE2000 Plug and Play clones fall into this category). In this case, 
  202. follow these steps to use your Plug and Play card with a 16-bit NIC 
  203. driver:
  204.  
  205. 1. Run the Softset utility that comes with your Plug and Play card, 
  206.    and then set the card to non-Plug and Play mode.
  207. 2. Remove the network card from the list of devices in the Device 
  208.    Manager listing: In Control Panel, double-click the System icon, 
  209.    click the Device Manager tab, select the network card, and then 
  210.    click Remove.
  211. 3. Reinstall the network card using the Add New Hardware icon in 
  212.    Control Panel.
  213.  
  214. When you install a 32-bit protect mode NIC driver in the future, you 
  215. can rerun Softset to turn on Plug and Play mode for your card. This 
  216. problem does not happen if you are using a 32-bit protect-mode NIC 
  217. driver.
  218.  
  219.  
  220. INTEL ETHEREXPRESS 16 NICs AND PCI COMPUTERS
  221. ============================================
  222.  
  223. If you are using an Intel EtherExpress 16-network interface card (NIC) 
  224. in a PCI computer that has a Diamond Speed Star PCI video card, your 
  225. system might hang or not initialize properly. These problems, according 
  226. to Intel customer support, are not related to Windows 95 and happen
  227. on a variety of operating systems. 
  228.  
  229. If you have one of the following video cards, contact your vendor to 
  230. obtain a new video BIOS update:
  231.  
  232.    * Diamond Speed Star PCI video card with BIOS version 1.01
  233.    * Diamond Viper PCI VGA Video Adapter
  234.    * Diamond Stealth video card, BIOS v1.03
  235.  
  236. Other PCI video cards might also cause problems with this Intel NIC.
  237. In general, if you experience problems with your EtherExpress 16 in 
  238. a PCI computer other than those described above, please replace the 
  239. card before reporting the problem to Microsoft.
  240.  
  241.  
  242. WINDOWS FOR WORKGROUP SHARES
  243. ============================
  244.  
  245. When you upgrade to Windows 95 from Windows for Workgroups, your 
  246. shares are not maintained. The folders/directories you shared in 
  247. Windows for Workgroups need to be reshared. 
  248.  
  249.  
  250. RUNNING WINDOWS 95 FROM A SERVER
  251. ================================
  252.  
  253. Windows 95 can be set up to run from a network server. The Windows 95 
  254. Resource Kit contains complete instructions for installing Windows 
  255. in this environment (see Chapter 4, "Server Based Setup for Windows 95").
  256.  
  257. The following configurations are supported:
  258.  
  259. - Booting from hard disk using:
  260.   - Client for Microsoft Networks
  261.   - Client for NetWare Networks
  262.   - Novell Workstation Shell 3.x (NETX)
  263.   - Novell Workstation Shell 4.x (VLM)
  264.   - Banyan VINES DOS/Windows client
  265.  
  266. - Booting from a floppy disk using:
  267.   - Client for Microsoft Networks
  268.   - Client for NetWare Networks
  269.   - Novell Workstation Shell 3.x (NETX)
  270.   - Novell Workstation Shell 4.x (VLM)
  271.   - Banyan VINES DOS/Windows client
  272.  
  273. - Booting from a remote boot server using:
  274.   - Client for NetWare Networks
  275.   - Novell Workstation Shell 3.x (NETX)
  276.   - Novell Workstation Shell 4.x (VLM)
  277.  
  278. To use one of the Microsoft clients, your network card must have 
  279. both an NDIS2 (16-bit real mode) *AND* an NDIS3 (32-bit protect 
  280. mode) driver. If your network card is a PCI, EISA, or ISAPNP card, 
  281. you must run Windows over a real-mode client.
  282.  
  283. To Install Windows 95 over Previous Builds
  284. ------------------------------------------
  285. To install this final version of Windows 95 on network computers that 
  286. are already running Windows 95, you have two choices:
  287.  
  288. - Do a clean install on each  computer;
  289.   -or-
  290. - Upgrade each computer using the following procedure:
  291.  
  292.   1. Shut down any clients running from the server.
  293.   2. Windows 95 must be installed on the server into the same folder 
  294.      that you were using for previous builds. Delete everything in the 
  295.      shared Windows 95 folder, and then run Netsetup.exe to install this 
  296.      build into that folder.
  297.   3. Restart the client to a command prompt.
  298.   4. If you are using the Microsoft Client for NetWare Networks and use 
  299.      map rooted  drives, you must start either NETX or VLM to run Setup.
  300.   5. Map drives to the machine folder and shared Windows 95 folder 
  301.      as before. These must use the same drive letters as used in the 
  302.      previous build, and map roots should be to the same folder level.
  303.   6. Run Setup for the new build.
  304.  
  305.  
  306. SUPPORT FOR THIRD-PARTY NETWORKS
  307. ================================
  308.  
  309. To install support for a third-party, real-mode network, you must be 
  310. running the network when you run Windows 95 Setup. Windows 95 does not 
  311. support installation of a real-mode network after Setup, unless you have 
  312. a Windows 95-specific .inf file from your network vendor. For example, 
  313. FTP includes a Windows 95 .inf in their 32-bit NFS client. Although 
  314. Windows 95 supports other networks, network component files for networks 
  315. other than Microsoft networks are not included with Windows 95. You must 
  316. already have the files for the network you want to install. 
  317.  
  318. LANDESK 2.0
  319. -----------
  320. LANDESK version 2.0 uses a TSR named Usertsr.exe that might cause 
  321. Windows 95 to stop responding when you use the Microsoft IPX/SPX-
  322. compatible protocol (Nwlink.vxd) or file and printer sharing for 
  323. Microsoft Networks (Vserver.vxd).
  324.  
  325. LANDESK version 2.01 fixes this problem, and the patch is available 
  326. on Intel's BBS or from Intel product support. For the BBS and product 
  327. support telephone numbers, consult the documentation that came with your 
  328. copy of LANDESK.
  329.  
  330. SunSelect PC-NFS
  331. ----------------
  332. Windows 95 supports versions 5.0 or greater of SunSelect PC-NFS. 
  333. If SunSelect PC-NFS is installed using an NDIS 2 LAN driver or an 
  334. ODI LAN driver, then SunSelect PC-NFS can be installed as an additional 
  335. 16-bit network client along with 32-bit protected-mode clients. If you 
  336. are using a SunSelect PC-NFS LAN Driver, Windows 95 can support PC-NFS 
  337. only as the primary network. Additional 32-bit network providers are not 
  338. possible in this case.
  339.  
  340. Banyan VINES 
  341. ------------
  342. If you see a message during startup that the VINES version is not the 
  343. latest, edit the Vines.ini file in the Windows folder so it contains 
  344. the following lines:
  345.  
  346.    [NEWREV]
  347.    dontcopy=1
  348.    vines.version=5.5x (x) USA      ; where x=your version
  349.    windows.version=3.95
  350.  
  351. If you receive the message, "Vines NDIS Interface error: 1021. See 
  352. NDISBAN.DOC for an error description," during startup, run the VINES 
  353. utility PCCONFIG to change Banyan drivers to NDIS drivers. Also, make 
  354. sure the section name matches the driver name in the Protocol.ini file.
  355.  
  356. DEC Pathworks
  357. -------------
  358. Windows 95 provides support for upgrading over existing DEC 
  359. PATHWORKS V5.0, V5.0A and V5.1 configurations. This makes it possible 
  360. to run your existing real-mode PATHWORKS components while migrating 
  361. to Windows 95. However, it is strongly recommended that you upgrade 
  362. to DEC's PATHWORKS for Windows 95, which contains protected-mode 
  363. components.
  364.  
  365. Restrictions:
  366. PATHWORKS must be started before running Windows 95 Setup to 
  367. automatically detect and upgrade PATHWORKS components. If PATHWORKS 
  368. is not started or is not automatically detected, you will see startup 
  369. errors when you run STARTNET. To correct this, add the appropriate 
  370. "PATHWORKS V5.0 and above" protocol, using the Network icon in Control 
  371. Panel.
  372.  
  373. Once a system has been upgraded to Windows 95, you cannot change your
  374. PATHWORKS configuration using PWSETUP. However, all existing template
  375. configurations present when you upgrade are converted to work under
  376. Windows 95.
  377.  
  378. PATHWORKS Native, DLC, X.25, and ISDN datalinks are converted to use
  379. an NDIS driver, if available, during the upgrade. If the replacement
  380. NDIS driver is not configured correctly or is not operating, startup
  381. will display an error and prevent loading of other PATHWORKS components.
  382.  
  383. To correct this, double-click the Network icon in Control Panel, and 
  384. verify that the adapter driver is configured correctly. If any changes 
  385. are made to the adapter configuration, you must remove the "PATHWORKS 
  386. V5.0 and above" protocol and add it again.
  387.  
  388. PATHWORKS NetWare client licenses (CCS or FPA) are not currently
  389. supported with Windows 95. If you are using the Microsoft Client for
  390. NetWare Networks to connect to PATHWORKS for OpenVMS (NetWare) or
  391. PATHWORKS for OSF/1 (NetWare) servers, the server must have PATHWORKS 
  392. FPS licenses.
  393.  
  394. Long filenames do not work correctly on PATHWORKS servers up to and
  395. including version 5.0b. You will be able to create and delete LFN 
  396. files and make and remove LFN folders, but the files and folders will 
  397. not appear when you use the DIR command, or when you open an Explorer 
  398. window to the PATHWORKS server. PATHWORKS server version 5.00 EC01 
  399. corrects this problem and is available from DEC.
  400.  
  401. Artisoft LANtastic
  402. ------------------
  403. The LANtastic server cannot be run when Windows 95 is setting up.
  404.  
  405. LANtastic also cannot be run in conjunction with networking support 
  406. for other networks.
  407.  
  408.  
  409. PRINTING TO A NETWORK PRINTER
  410. =============================
  411.  
  412. You might have problems setting up a printer that is shared by a third-
  413. party network server. The solution is to redirect LPT1 through an 
  414. MS-DOS window to the third-party share, and then use the printer setup 
  415. for LPT1.
  416.  
  417. For example, if a network printer is connected to LPT1, follow these 
  418. steps: 
  419.  
  420. 1. At the MS-DOS prompt, type:
  421.  
  422.    net use lpt1: \\servername\sharename
  423.  
  424.    (This command might be different on the network you are using. 
  425.    Check the product documentation to find out how to redirect
  426.    an LPT port.)  
  427.  
  428. 2. Start Control Panel, double-click Printers, and then double-click 
  429.    Add Printer. 
  430.  
  431.  
  432. PROBLEMS PRINTING TO POSTSCRIPT PRINTERS
  433. OVER A NETWARE NETWORK
  434. =========================================
  435.  
  436. If you have problems when printing to a PostScript printer over a 
  437. network, (error messages on the printer; no output is printed), it 
  438. might be due to incorrectly configured Banner Pages. To solve this 
  439. problem, you can do one of the following:
  440.  
  441. - Disable banner pages by removing the check mark from the Banner Pages 
  442.   box on the Capture printer properties (open the Printers folder, click 
  443.   the icon for the printer you are using, and then click Properties on 
  444.   the File menu);
  445.   -or-
  446. - Ask your network administrator to correctly configure banner pages on 
  447.   the Netware server for a PostScript printer.
  448.  
  449.  
  450. ISSUES AND INSTALLATION OF
  451. MS-DLC WITH WINDOWS 95
  452. -=========================
  453.  
  454. Windows 95 contains MS-DLC and support for installing over an existing 
  455. MS-DLC or IBM-DLC installation. Setup will detect DLC and make the 
  456. appropriate changes to your configuration files for these. Refer to 
  457. the Windows 95 Resource Kit, Chapter 10, for a complete description 
  458. of DLC support.
  459.  
  460.  
  461. MICROSOFT TCP/IP PROTOCOL
  462. =========================
  463.  
  464. If Microsoft's TCP/IP is the only protocol you have loaded on your 
  465. system, the IP Address will not be added during Setup. If you have 
  466. a DHCP server, open Control Panel, double-click the Network icon, and 
  467. then close it. This will update the IP Address. (If you don't know if 
  468. you have a DHCP server, check with your network administrator, or check
  469. if your IP address is already entered.)
  470.  
  471. If you don't have a DHCP server, start Control Panel, double-click 
  472. the Network icon, double-click TCP/IP, click the IP Address tab, and 
  473. then enter your IP Address.
  474.  
  475. If you are not updating from a previous Windows 95 installation (you 
  476. are doing a "clean install"), to use DNS or LMHOSTS name resolution, 
  477. make sure you have DNS enabled in the Network properties. To enable
  478. DNS, double-click the Network icon in Control Panel, double-click 
  479. TCP/IP, click the DNS configuration tab, and then click Enable DNS.
  480.  
  481.  
  482. USER PROFILES OVER THE NETWORK
  483. ==============================
  484.  
  485. If you are using user profiles over a Windows NT or Novell NetWare 
  486. network, and you include Start Menu/Programs, Network Neighborhood,
  487. and/or desktop icons in your profile, the server must have long 
  488. filename support to ensure that these parts of the user profile work 
  489. over the network. 
  490.  
  491.  
  492. NETWORK BACKUP AGENTS
  493. =====================
  494.  
  495. Arcada Backup Exec Network Backup Agent
  496. ---------------------------------------
  497. To use the Arcada Backup Exec network backup agent included in 
  498. Windows 95, you must have Arcada Backup Exec version 5.x.
  499.  
  500.  
  501. Cheyenne ARCserve Network Backup Agent
  502. --------------------------------------
  503. To use the Cheyenne ARCserve network backup agent included in 
  504. Windows 95, you must have Cheyenne ARCserve version 5.01F. You might 
  505. also use earlier versions if you obtain updated NLMs from Cheyenne 
  506. Software.
  507.  
  508.  
  509. REAL-MODE PROTOCOLS: WARNING ICONS ON YOUR NETWORK ADAPTER
  510. ==========================================================
  511.  
  512. If you install a network that does not use protected-mode protocols, 
  513. such as Novell Netware 3.x, you might see a yellow warning icon next 
  514. to your network adapter in Device Manager. You can ignore this warning; 
  515. your network is fully functional. To remove the warning icon, use the 
  516. program, Extract.exe on Setup disk 1 to extract the file Ndis.vxd from 
  517. your Windows 95 disks. Then, copy Ndis.vxd into your Windows\System 
  518. folder. When you reboot your system, the yellow warning icon will no 
  519. longer appear.
  520.  
  521.  
  522. USING AN IBM THINKPAD WITH A DOCK II
  523. ====================================
  524. If you enable 32-bit PCMCIA support, and your network cards do not 
  525. appear to work properly when inserted into the Dock II's PCMCIA slots; 
  526. or, if you have an ISA network card in the Dock II that has a "Code 10" 
  527. error in its properties in Device Manager, call the IBM Help Center. 
  528. They will provide you with a file to correct this problem.
  529.  
  530.  
  531. INTEL ETHEREXPRESS PRO /100B CARD NOT CORRECTLY DETECTED
  532. ========================================================
  533.  
  534. Windows 95 does not correctly detect an Intel EtherExpress Pro /100B 
  535. card during Setup or hardware detection. After Setup, an entry for 
  536. "PCI Ethernet controller" appears under Other Devices in Device Manager, 
  537. which shows that the device is functioning properly; however, the card 
  538. doesn't work.
  539.  
  540. To properly install the card, remove the PCI Ethernet controller from 
  541. Device Manager, and then restart your computer. The card will then be 
  542. detected; the Update Device Driver wizard will appear.  Insert the 
  543. driver disk that came with the card, and then click Next. The wizard 
  544. will search the disk and find drivers for the Intel 82557-based PCI 
  545. Ethernet. This is correct. Click Finish and the card should work.
  546.  
  547.  
  548. SETTING UP A WINS SERVER
  549. ========================
  550.  
  551. To set up a WINS server, carry out the following steps:
  552.  
  553. 1. In Control Panel, double-click the Network icon.
  554. 2. Click TCP/IP, and then click Properties.
  555. 3. Click the WINS Configuration tab.
  556. 4. Make sure that both the Primary WINS Server and Secondary WINS 
  557.    Server boxes are filled in.
  558.  
  559.    If you have only one WINS Server, you must enter the identical 
  560.    information in both the Primary WINS Server and Secondary WINS 
  561.    Server boxes.
  562.  
  563.    If you do not fill in both boxes, your WINS setting will be 
  564.    changed to Disable WINS Resolution when you restart your computer. 
  565.  
  566.