home *** CD-ROM | disk | FTP | other *** search
/ Soft 19 / Soft19.iso / win95-rc / win95_04.cab / hardware.txt < prev    next >
Text File  |  1996-08-06  |  22KB  |  521 lines

  1.        -----------------------------------------------------------
  2.                    Microsoft Windows 95 README for Hardware
  3.                                    August 1996            
  4.        -----------------------------------------------------------
  5.  
  6.                    (c) Copyright Microsoft Corporation, 1996
  7.  
  8.  
  9. This document provides complementary or late-breaking information to
  10. supplement the Microsoft Windows 95 documentation.
  11.  
  12. ------------------------
  13. How to Use This Document
  14. ------------------------
  15.  
  16. To view Hardware.txt on screen in Notepad, maximize the Notepad window.
  17.  
  18. To print Hardware.txt, open it in Notepad or another word processor, 
  19. then use the Print command on the File menu.
  20.  
  21.  
  22. -------- 
  23. CONTENTS
  24.  
  25. PLUG AND PLAY
  26. SCANNERS
  27. MODEMS
  28. TAPE DRIVES
  29. RUNNING ZIP TOOLS ON AN IOMEGA PARALLEL ZIP DISK
  30. --------
  31.  
  32.  
  33. PLUG AND PLAY
  34. =============
  35.  
  36. PCI Systems
  37. -----------
  38. If the video is configured by the BIOS to consume an IRQ and you need 
  39. to use the secondary PCI IDE controller in your PC, your video will work 
  40. only in VGA mode. To load the accelerated Windows 95 driver for your video, 
  41. disable the secondary PCI IDE controller in the BIOS and the Device Manager 
  42. (located in the System control panel). Another alternative (if supported 
  43. by the BIOS) is to disable the IRQ of the video device. 
  44.  
  45. IBM Thinkpad Models 750 (all 750 series except 750ce)
  46. -----------------------------------------------------
  47. A new BIOS that solves several problems with power management is
  48. available from IBM's bulletin board. Download the latest System Program 
  49. Service Diskette for the Thinkpad 750 from the BBS. See your hardware
  50. documentation for information on how to access the IBM bulletin board.
  51.  
  52. IBM Thinkpad Models 755cd, cx, ce, cse, cdv (but not 755c)
  53. ----------------------------------------------------------
  54. We are in the process of resolving with IBM several known problems:
  55. 1. Mwave is lost if you have more than 8 MB of memory.
  56.    - IBM is working on updated drivers. The 1.1 revision does not
  57.      solve this problem.
  58. 2. If you install Windows 95 into the same directory that contains 
  59.    your current version of Windows, Mwave will continue to function. 
  60.    - If you install Windows 95 to a different directory, Mwave will 
  61.      not work unless you reinstall the Mwave drivers by using IBM's 
  62.      Mwave setup program disks. This is by design. The Windows 3.1 
  63.      drivers are required to run the Mwave chip.
  64. 3. The infrared port shows up with problems in Device Manager.
  65.    - IBM is working on an updated Infrared VxD that resolves this
  66.      problem.
  67. 4. Docking is not supported.
  68.    - IBM is expected to release fixes to their Plug and Play BIOS 
  69.      shortly, which will enable full Windows 95 Plug and Play and 
  70.      docking support. For updates to the System Program Service 
  71.      Diskette for your model of Thinkpad, check IBM's bulletin 
  72.      board. See your hardware documentation for information about
  73.      accessing the bulletin board.
  74. 5. There are power management problems with the suspend and resume
  75.    commands.
  76.    - If you have a 1994 BIOS, you can usually resolve these problems
  77.      by upgrading to the latest Flash BIOS revision from 1995. You can
  78.      find it on CompuServe, THINKPAD forum, or on IBM's bulletin board.
  79.      See your IBM hardware documentation for information about accessing
  80.      the bulletin board.
  81. 6. Mwave versions earlier than 1.2 contain numerous bugs.
  82.    - These bugs in earlier versions of Mwave cause serious problems when 
  83.      Mwave is run on Windows 95. For more information, call the IBM PC 
  84.      HelpCenter.  
  85.  
  86. IBM Thinkpad Dock II
  87. --------------------
  88. If you use IBM Thinkpad Dock II, you must disable the BIOS for the
  89. Adaptec 1530P SCSI controller in the docking station before starting
  90. your computer while it is docked. If you do not, your computer will
  91. hang repeatedly. This controller works fine in protected mode even
  92. without the BIOS enabled, so you should not lose access to any SCSI
  93. devices as a result.
  94.  
  95. To disable the BIOS:
  96. 1. Restart your computer while it is docked.
  97. 2. Press CTRL+A to start the Adaptec SCSISelect utility.
  98. 3. Choose Configure/View Host Adapter Settings.
  99. 4. Choose Advanced Configuration Options.
  100. 5. Change the setting for Host Adapter BIOS to Disabled.
  101.  
  102. Press ESC until you are prompted to exit the utility, at which point
  103. the computer will restart.
  104.  
  105. An even better solution is to disable the BIOS completely, which will
  106. enable the adapter to run completely in Plug and Play mode. This will
  107. allow its resources to be allocated dynamically at Windows 95 startup.
  108. However, this requires changing a DIP switch inside the dock unit.
  109. For details about disabling the SCSI adapter BIOS, refer to your Dock II
  110. manual.
  111.  
  112. Micron M5-PI Series
  113. -------------------
  114. Before installing Windows, users of Micron M5-PI series (P-60, P-66) 
  115. need to be sure the BIOS read/write jumper(W22) is set to the read-only 
  116. position. If you try to install Windows 95 with this jumper in the
  117. read\write position, it may cause BIOS corruption. For more information,
  118. contact Micron Technologies.
  119.  
  120. Micron P90/100
  121. ---------------
  122. Before installing Windows, users of Micron P90 and P100 systems must 
  123. make sure their BIOS version is N15 or later. For more information, 
  124. contact Micron Technologies.
  125.  
  126. NEC Versa M and AT&T Globalyst
  127. ------------------------------
  128. If you use AT&T Globalyst and NEC Versa M, you must set the BIOS
  129. setting for PCMCIA Power to Enabled before running the PC Card (PCMCIA)
  130. wizard to enable the Windows 95 PCMCIA support. The default setting is
  131. Disabled. 
  132.  
  133. To change the PCMCIA Power setting to Enabled:
  134. 1. Restart your computer.
  135. 2. When the cursor changes to a rectangle, press F1.
  136. 3. When the BIOS configuration program is ready, select Power, and
  137.    then change the PCMCIA Power setting to Enabled.
  138. 4. Save these settings.
  139.  
  140. Winbook XP
  141. ----------
  142. There is a problem on the Winbook XP which could cause the keyboard
  143. not to function properly. The workaround is to disable Windows 95
  144. power status polling.
  145.  
  146. To disable Windows 95 power status polling:
  147. 1. In Control Panel, double-click the System icon, and then click the
  148.    Device Manager tab.
  149. 2. Click the plus (+) sign next to the system class you want to change.
  150. 3. Double click Advanced Power Management Support, and then click the
  151.    Settings tab.
  152. 4. Make sure that the Disable Power Status Polling box is checked.
  153. 5. Click OK to save your changes and exit Control Panel.
  154.  
  155. HP OmniBook 600C
  156. ----------------
  157. The Omnibook's PCMCIA controller is supported via special drivers 
  158. in the Drivers directory on the CD version of Windows 95, or via the 
  159. Windows Drivers Library (WDL) on various on-line services. 
  160. Refer to the Readme file in the Drivers directory for installation 
  161. instructions. 
  162.  
  163. The OmniBook also requires a special mouse driver for Windows. 
  164. Windows 95 Setup will preserve and use this driver when upgrading over 
  165. Windows 3.1. If you installed Windows 95 into a new directory 
  166. on an OmniBook, then you must copy the HP Obmouse.drv file into the 
  167. Windows\System directory, and then change the following lines in your 
  168. System.ini file:
  169.  
  170.     [boot]
  171.     mouse.drv=obmouse.drv
  172.  
  173.     [386Enh]
  174.     mouse=*vmd
  175.  
  176. DEC Hi Note Ultra
  177. ------------------
  178. There are known problems with PCMCIA under older BIOS versions on 
  179. this machine. If you encounter difficulties getting your PCMCIA cards 
  180. recognized correctly, update your BIOS to a version later than 
  181. 3/31/95 (v.1.3).
  182.  
  183. Acer Acernotes
  184. --------------
  185. You may hear a negative (low) tone when you insert the PCMCIA card
  186. after activating the 32-bit PCMCIA drivers. If this happens, remove
  187. the EMMExclude line from the System.ini file and the exclude range
  188. data from the EMM386 line in the Config.sys file. If you still get a
  189. low tone, try carrying out the following procedure:
  190.  
  191. 1. Double-click the PCMCIA icon in Control Panel.
  192. 2. Click Global Settings, and make sure Automatic Selection is not
  193.    checked.
  194. 3. Set the valid range to start at 000D0000 and end at 000DFFFF.  
  195.  
  196. Compaq Aero
  197. ------------
  198. The Compaq Aero floppy disk drive is only partially supported by the 
  199. Windows 95 PCMCIA drivers. To gain access to the floppy drive, 
  200. you need to make sure the card is already inserted when you boot. 
  201. After the card has been configured by Windows 95, you can remove and 
  202. insert the card normally. 
  203.  
  204. If access to the floppy card still fails:
  205. 1. In Control Panel, double-click the System icon, and then click the
  206.    Device Manager tab.
  207. 2. Click the plus (+) sign next to "Floppy disk controllers."
  208. 3. Double-click the floppy disk controller you are having trouble with.
  209. 4. Look at the Device Status area. 
  210. 5. If it reports a resource conflict, click the Resources tab, 
  211.    click the "Set Configuration Manually" button, then click OK.
  212.  
  213. DEC Venturis and Media Vision Audio Cards
  214. -----------------------------------------
  215. There's a known problem with certain combinations of the DEC Venturis 
  216. and Media Vision Audio cards.
  217.  
  218. If you experience problems with this combination:
  219. 1. In Control Panel, double-click the System icon.
  220. 2. Click the Device Manager tab.
  221. 3. Under Sound, Video and Game Controllers, double-click
  222.    Media Vision Pro Audio Spectrum 16/Studio With SCSI.
  223. 4. Click the Settings tab.
  224. 5. Make sure the Enable Warm Boot box is not checked.
  225.  
  226. Zenith NoteFLEX 486DX and PC cards
  227. -----------------------------------
  228. If your PC cards are not being detected or working properly with the 
  229. Windows 95 PCMCIA drivers, follow the below procedure to reserve IRQ 10
  230. and the memory range C000-CBFF.
  231.  
  232. To reserve resources:
  233. 1. In Control Panel, double-click the System icon.
  234. 2. Click the Device Manager tab.
  235. 3. Click Computer, and then click Properties.
  236. 4. Click the Reserve Resources tab.
  237. 5. Click Interrupt Request (IRQ), and then click Add.
  238. 6. Reserve IRQ 10, and then click OK. 
  239. 7. Click Memory, and then click Add.
  240. 8. Reserve the memory range C000-CBFF, and then click OK.
  241. 9. Click OK again, and then restart your computer.
  242.  
  243. Zenith NoteFLEX 486DX and Flexshow docking station
  244. --------------------------------------------------
  245. If you are using the NoteFLEX with the Flexshow docking station, you 
  246. must reserve IRQ 10 so that the built-in CD-ROM drive will work. To 
  247. do this, follow the above procedure and only reserve IRQ 10.
  248.  
  249. In your Config.sys file, make sure the line loading Mztinit.sys 
  250. appears before the line loading PCenable.exe or your computer will 
  251. stop responding during startup.
  252.  
  253. Also, to avoid numerous "Bad Command or File Name" errors during 
  254. startup and to ensure the computer is configured properly, copy 
  255. Rplstr.com from your \Dos directory to your \Windows directory.
  256.  
  257. Zenith NoteFLEX 486DX and PCMCIA hard drives
  258. --------------------------------------------
  259. If you are using a PCMCIA hard drive with this computer, you must 
  260. enable 32-bit PCMCIA support in order to access the drive.
  261.  
  262. To enable 32-bit PCMCIA support:
  263. 1. In Control Panel, double-click the PC Card (PCMCIA) icon.
  264. 2. Follow the instructions on your screen.
  265.  
  266. If you see properties for your PCMCIA socket instead of the wizard, 
  267. Windows 32-bit support for PC cards is already turned on. If you do not 
  268. see the PC Card (PCMCIA) icon in Control Panel, double-click the 
  269. Add New Hardware icon in Control Panel to install your PCMCIA socket.
  270.  
  271. Megahertz Em1144T and 16-bit Modem
  272. ----------------------------------
  273. If you experience problems setting up the modem side of this card 
  274. in a real-mode PCMCIA environment, try explicitly setting the COMIRQ 
  275. and COMBASE parameters in the Megahertz section of your Protocol.ini 
  276. file. There is a known problem where this card enabler ignores the 
  277. default values set for these parameters.
  278.  
  279. Digital Venturis (any model)
  280. ----------------------------
  281. If PNPISA and/or PCI cards are not automatically recognized, or if 
  282. Windows generates Blue Screen errors when reconfiguring your COM ports, 
  283. contact Digital for a new BIOS.
  284.  
  285. Printing from Device Manager
  286. ----------------------------
  287. If you choose to print "all devices and system summary" from Device
  288. Manager, the device detection code MAY cause problems for MS-DOS-
  289. based programs. The symptom of this problem is that after you print,
  290. your computer reports that it is out of memory when you try to run 
  291. an MS-DOS-based program. When this problem occurs, you may need to 
  292. restart Windows to correct the problem. 
  293.  
  294. Mozart Sound Card/Canon Innova 550 CD Driver Problem
  295. ----------------------------------------------------
  296. You may experience problems when you start up Windows 95. To receive
  297. a new driver that works with Windows 95, contact the Canon Help Desk.
  298.  
  299. Users of TrueFFS Flash File System for PCMCIA Cards 
  300. ---------------------------------------------------
  301. The MS-DOS or Windows 3.1 versions of the TrueFFS driver will not work 
  302. with the Windows 95 PCMCIA driver. To work with FTL formatted Linear 
  303. Flash PCMCIA cards when the Windows 95 PCMCIA driver is enabled, you 
  304. must install a new Windows 95 device driver provided by M-Systems. To 
  305. do this, carry out the following procedure:
  306.  
  307. 1. In Control Panel, double-click the Add New Hardware icon. 
  308. 2. Click Next, and then click the option not to have Windows search 
  309.    for your new hardware.
  310. 3. Click Hard Disk Controllers, and then click Next.  
  311. 4. From the list, click M-Systems. 
  312. 5. Click the specific Flash Card, and then click Next. Then follow 
  313.    the instructions on your screen.
  314.  
  315. NOTE: If M-Systems is not shown in the list, click Have Disk, and then
  316. insert the M-Systems Windows 95 installation disk and follow the 
  317. instructions on your screen.
  318.  
  319. Micronics Motherboards with a Flash BIOS
  320. -----------------------------------------
  321. Before installing Windows, users of Micronics motherboards with a Flash 
  322. BIOS need to be sure the BIOS read/write jumper is set to the read-only
  323. position. If you try to install Windows 95 with this jumper in the 
  324. read\write position, it may cause BIOS corruption. For more information,
  325. contact your computer manufacturer.
  326.  
  327. Toshiba Computers: T610 T400 series, T2100 series, T2400 series, 
  328. T4700 series, T4800 series, and the T4900CT and T3600
  329. ----------------------------------------------------------------
  330. If you use any of these Toshiba computers, Toshiba strongly recommends 
  331. upgrading your computer's BIOS to version 5.0. The upgraded BIOS 
  332. provides additional functionality for the Windows 95 operating system. 
  333. For more information, in the United States contact Toshiba at 
  334. (800) 999-4273. Outside the U.S., contact your local Toshiba dealer.
  335.  
  336. Toshiba T2150 models
  337. ---------------------
  338. If your system stops responding during suspend or resume operations, 
  339. comment out the line that loads the Toscdrom.sys driver from your 
  340. Config.sys file. For example:
  341.  
  342.     rem device=c:\cddrv\toscdrom.sys
  343.  
  344. Sanyo 3-D ATAPI (IDE) CD-ROM drive
  345. ----------------------------------
  346. The Sanyo 3-D ATAPI (IDE) CD-ROM drive uses a proprietary scheme to 
  347. support the three-disk changer. Although all three drives will appear 
  348. when you are running in protected mode, only one of them will be 
  349. accessible.
  350.  
  351. To regain access to all three drives, remove the REM command from the 
  352. beginning of the MSCDEX line in your Autoexec.bat file. You also need 
  353. to disable the Windows 95 protected-mode disk driver. To do this, carry 
  354. out the following procedure:
  355.  
  356. 1. Click the Start button, and then point to Settings.
  357. 2. Click Control Panel, and then double-click the System icon.
  358. 3. Click the Device Manager tab.
  359. 4. Click View Devices By Connection.
  360. 5. Click plus signs next to devices until you find the Sanyo drive.
  361. 6. After you find the Sanyo drive, look at the levels above it
  362.    until you find the parent controller.
  363. 7. Click the controller, and then click Properties.
  364. 8. In the Device Usage area, clear the check box next to the current 
  365.    configuration.
  366.  
  367. This will enable access to all three drives from Windows 95 protected-
  368. mode; however, your disk, CD, and any other devices under the controller
  369. will be accessed only through real-mode drivers.
  370.  
  371. For information about updating your driver to a Windows 95 driver, 
  372. contact your hardware vendor.
  373.  
  374. Micron PowerServer M5-PE (66 MHz Pentium PCI/EISA bus)
  375. -------------------------------------------------------
  376. The BusLogic BT-946C PCI SCSI adapter may not be compatible with 
  377. Windows 95. If you encounter difficulties with your SCSI peripherals, 
  378. contact Micron to determine whether you need an updated adapter.
  379.  
  380.  
  381. SCANNERS
  382. ========
  383.  
  384. Windows 95 will detect most scanner hardware, but does not supply
  385. protected-mode drivers for any scanner model.
  386.  
  387. All SCSI scanners use a feature called ASPI to talk to the controller
  388. in question. Windows 95 supports ASPI in protected mode. Hence, a
  389. scanner, although listed as an "unknown device" in Device Manager, is
  390. supported through protected-mode drivers in Windows 95, if there is a
  391. protected-mode driver for the SCSI controller in question.
  392.  
  393. Note that theoretically you would not need the ASPI manager real-mode
  394. driver (such as Aspi2dos.sys) in your Config.sys file. However, some
  395. programs, such as HP ScanJet II and its associated real-mode drivers,
  396. Sj!!.sys and Sjiix.sys, require the real-mode ASPI manager to be in the
  397. Config.sys file or they will fail to load. In these cases, you would
  398. need to keep the real-mode drivers in the Config.sys file, but
  399. Windows 95 will still support the scanner through the protected-mode
  400. SCSI miniport driver (if one exists for the SCSI controller in question).
  401.  
  402. Logitech Scanman
  403. ----------------
  404. If you use a handheld Logitech Scanman on a computer that has more than 
  405. 16 MB of memory, you may see the following message: "Insufficient
  406. system resources." To resolve this problem, you can obtain an updated 
  407. driver, Scanupt.exe, from the Logitech bulletin board or from CompuServe.
  408.  
  409.  
  410. MODEMS
  411. ======
  412.  
  413. Modems Control Panel
  414. --------------------
  415. In order to use your modem with the built-in communications features
  416. of Windows 95, including HyperTerminal, and Dial-Up Networking, your 
  417. modem must be configured in Modems properties in Control Panel.
  418.  
  419. Settings made in Modems properties do not affect modem operation in
  420. programs designed for MS-DOS or Windows 3.1.
  421.  
  422. Modem Detection
  423. ---------------
  424. If Windows 95 detects your modem as a "Standard Modem," or incorrectly
  425. detects its make and model, you can use the Change button in the
  426. Install New Modem wizard to make a different selection. However, if
  427. you manually select an incorrect type, your modem may not to work with
  428. Windows 95 communications features. If this happens, double-click the
  429. Modems icon in Control Panel, remove the modem, and then add it back
  430. as one of the Standard modem types.
  431.  
  432. When configured for "Standard Modem," Windows 95 will use your modem
  433. with its factory default settings. The modem will make optimal high-
  434. speed connections with Windows 95 communications features. However,
  435. you will not be able to adjust some of the modem's settings, such as
  436. speaker volume and cellular protocols.
  437.  
  438. Racal Modems
  439. ------------
  440. If you have a Racal modem, do not use detection in the Install New Modem
  441. wizard. Instead, click Don't Detect My Modem, and then pick one of the
  442. standard modem types. If you have already run detection and your modem
  443. is not responding, turn the modem off and then back on again.
  444.  
  445. Minitel (France)
  446. ----------------
  447. Some modems may not be able to connect to French Minitel in
  448. HyperTerminal by using the Windows 95 default settings. To correct this,
  449. carry out the following procedure:
  450.  
  451. 1. Check your modem manual for a command that will enable your modem to
  452.    connect in V.23 modulation to Minitel.
  453. 2. In Control Panel, double-click the Modems icon, click the name of
  454.    your modem, and then click Properties.
  455. 3. Click the Connection tab, and then click Advanced.
  456. 4. In the Extra Settings box, type the command.
  457.  
  458.  
  459. TAPE DRIVES
  460. ===========
  461.  
  462. Tape Drive Detection
  463. --------------------
  464. Plug and Play software does not detect tape drives. As a result, the
  465. only tape drives that appear in Device Manager are SCSI tape drives,
  466. which appear as either an unknown device or a tape drive. 
  467.  
  468. However, most backup programs do detect tape drives, so don't be
  469. concerned if your tape drive does not appear in Device Manager. If
  470. your backup software does not detect your tape drive, contact the
  471. company that wrote the software.
  472.  
  473. Tape Drive Compatibility
  474. ------------------------
  475. Microsoft Backup works only with the 1992 or later versions of the
  476. tape drives listed below. If your tape drive does not appear in the
  477. list below, contact your tape drive manufacturer for information about
  478. backup software that you can use with Windows 95.
  479.  
  480. The following tape drives are compatible with Backup:
  481. - QIC 40, 80, and 3010 tape drives made by the following companies,
  482.   and connected to the primary floppy disk controller:
  483.     Colorado Memory Systems
  484.     Conner
  485.     IOmega
  486.     Wangtek (only in hardware phantom mode)
  487. - Colorado Memory Systems QIC 40, 80, and 3010 tape drives connected
  488.   through a parallel port.
  489.  
  490. The following are not compatible with Backup:
  491. - Drives connected to a secondary floppy disk controller or to an
  492.   accelerator card
  493. - Archive drives
  494. - Irwin AccuTrak tapes
  495. - Irwin drives
  496. - Mountain drives
  497. - QIC Wide tapes
  498. - QIC 3020 drives 
  499. - SCSI tape drives
  500. - Travan drives
  501. - Summit drives
  502.  
  503.  
  504. RUNNING ZIP TOOLS ON AN IOMEGA PARALLEL ZIP DISK
  505. ================================================
  506.  
  507. From within My Computer or Windows Explorer, if you right-click the 
  508. ZIP drive and then click Format, the IOMEGA Format windows display 
  509. an option for you to do a Full format of the drive. If you select 
  510. this option, the following blue-screen fatal-exception error might 
  511. occur:
  512.     
  513.      A fatal exception 0E has occurred at 0028:C3C64C51 in 
  514.      VXD IOMEGA (01) + 00000CB5. The current application will 
  515.      be terminated. Pressing any key closes the Explorer window.
  516.  
  517. To correct this problem, contact IOMEGA and obtain a new Iomega.vxd 
  518. file. Using the Find command on the Start menu, find the old Iomega.vxd 