  1.                  MICROPOLIS 1578 DISK DRIVE
  2.                        SPECIFICATIONS
  3.  
  4.                                     Model Number
  5. Unformatted Capacity:                 1578-15
  6.  
  7.   Total Mbytes        ---------------- 382.3 ---------------------
  8.   Disk Platters       -------------------- 8 ---------------------
  9.   Read/Write Heads    ------------------- 15 ---------------------
  10.   Cylinders           ----------------- 1224 ---------------------
  11.   Bytes per track     --------------- 20,832 ---------------------
  12.  
  13. Formatted Capacity (typical)
  14.  
  15.   Total Mbytes        ---------------- 331.7 ---------------------
  16.   Bytes per Sector    ------------------ 512 ---------------------
  17.   Sectors per Track   ------------------- 36 ---------------------
  18.  
  19. PC Setup
  20.  
  21.   When using SCSI in a PC, the most common method is to run your
  22.   setup program and define No Drives Present. The SCSI Host Adapter
  23.   will automatically self-configure on power-up. To install the
  24.   drive, follow the manufacturer's instructions to use the on-board
  25.   BIOS routine or software that was supplied with the Host Adapter.
  26.  
  27. Performance Specifications
  28.  
  29.   Seek Time (including settling time)     Track-to-Track   4 msec
  30.                                           Average         18 msec
  31.                                           Maximum         35 msec
  32.   Average Rotational Latency                            8.33 msec
  33.   Rotational Speed                              3600 rpm +/- 0.5%
  34.   Data Transfer Rate at Interface
  35.     Synchronous                                    4.0 Mbytes/sec
  36.     Asynchronous                                   1.6 Mbytes/sec
  37.   Internal Data Rate                                 10 Mbits/sec
  38.   MTBF                                              150,000 hours
  39.   Positioner                     Fully balanced rotary voice coil
  40.   Parking                                 Automatic park and lock
  41.  
  42. General Functional Specifications
  43.  
  44.   Interface                                                  SCSI
  45.   Supports Full Common Command Set
  46.   Write Precompensation Start Cylinder                      1224*
  47.   Reduced Write Current Start Cylinder                      1224*
  48.   Landing Zone                                               1224
  49.   Mounting Plane                                  Any orientation
  50.  
  51. Power Requirements
  52.  
  53.   +12V +/-5%                                           2.25A avg.
  54.                                       (4.25A max during start-up)
  55.   +5V +/-5%                                             2.0A avg.
  56.   Power dissipation, typical                             32 Watts
  57.  
  58. Drive Addressing and Interface Termination
  59.  
  60.                                               PIN 1
  61.            J2                     J1              |
  62.      ____________   _______________________________        J3
  63.   __|            |_|                               |___________ 
  64.  |  |____________| |_______________________________| |  POWER  |
  65.  |                     RN202     RN203     RN204     |_________|
  66.  |                        INTERFACE TERMINATORS                |
  67.  |                                                             |
  68.  |                             ... W201 Terminator Option      |
  69.  |                             123                             |
  70.  |                                                             |
  71.  |    Component Side          Spindle control option    W5     |
  72.  |                           Bus Parity Check Option    W4     |
  73.  |                                          Reserved   W20     |
  74.  |                                                   --ID0     |
  75.  |                                           SCSI ID --ID1     |
  76.  |                                                   --ID2     |
  77.  |                                                             |
  78.  
  79.  
  80.                ____ ID2\
  81.               | ___ ID1 \__SCSI ID
  82.               || __ ID0 /                     PIN 1
  83.          J2   |||                 J1              |
  84.      ____________   _______________________________      J3
  85.   __|            |_|                               |___________
  86.  |  |____________| |_______________________________| |  POWER  |
  87.  |                     RN201     RN203     RN204     |_________|
  88.  |  W4 W5               Interface Terminators                  |
  89.  |  |  |__Spindle                             Frame Ground W21 |
  90.  |  |     Control              W1 W2                           |
  91.  |  |     Option         Terminator Options                    |
  92.  |  |__Bus                     W11                             |
  93.  |     Parity Option        +5v To Bus                         |
  94.  |                                           Reserved   W20    |
  95.  |                                                             |
  96.  |                                                             |
  97.  |                                                             |
  98.  |                                                             |
  99.  |                                                             |
  100.  |                      Component Side                         |
  101.  |                                                             |
  102.  |                                                             |
  103.  
  104. ID0, ID1, ID2 SCSI Address Jumpers
  105.   The SCSI ID (drive address) jumpers are identified as ID0, ID1,
  106.   and ID2. ID selection is binary, as shown in the table below.
  107.  
  108.       SCSI                 Jumpers
  109.     Address             ID2   ID1  ID0
  110.     -------             ---   ---  --- 
  111.        0                out   out   out
  112.        1                out   out    in
  113.        2                out    in   out
  114.        3                out    in    in
  115.        4                 in   out   out
  116.        5                 in   out    in
  117.        6                 in    in   out
  118.        7                 in    in    in
  119.  
  120.   For  multiple drive installations, on one Host Adapter,each drive
  121.   must unique address. Drives are configured as SCSI ID 0 at the
  122.   factory.
  123.  
  124. RN202, RN203, RN204 Interface Terminator
  125.   The Interface Terminators factory installed at RN202, RN203, and
  126.   RN204 provide proper termination for the interface lines. When
  127.   daisy-chaining multiple drives, leave the terminators installed
  128.   only in the last physical drive on the daisy chain cable; remove
  129.   all three terminators from each of the other drives. In most 
  130.   PC/AT installations, the C: drive is actually at the end of the
  131.   cable and should retain the terminators.
  132.  
  133. W201 or W1, W2 Terminator Options
  134.   W201 positions 1-2 and 2-3 (or W1 and W2, respectively, on second
  135.   board shown) select the source of terminator power (+5V) for the
  136.   interface terminators. If a jumper is installed at positions 1-2
  137.   (W1) and no jumper is installed at position 2-3(W2)(the factory
  138.   default configuration), the drive provides terminator power. This
  139.   configuration is used for PC/AT applications. If no jumper is
  140.   installed at W201 position 1-2(W1) but a jumper is installed at
  141.   position 2-3(W2), terminator power must be provided by the host
  142.   computer system via interface connector J1,pin 26.
  143.  
  144. W11 Bus Option
  145.   W11 (only present on Rev C and higher boards of the second type
  146.   shown) allows the drive to supply interface terminator power to
  147.   the SCSI Bus. If W11 is not installed (the factory default
  148.   configuration), the drive does not supply SCSI bus interface
  149.   terminator power. W11 should not be installed for PC/AT
  150.   applications.
  151.  
  152. W5 Spindle Option
  153.   W5 selects the spindle control option. If W5 is installed, the
  154.   drive waits for a Start Spindle command (after power is applied)
  155.   to start the spindle motor. If W5 is not installed (the factory
  156.   default configuration), the drive automatically starts the  
  157. spindle motor at power-on. W5 is not installed for PC/AT  
  158. installations.
  159.  
  160. W4 Bus Parity Check Option
  161.   W4 selects the parity check option. If W4 is installed, the drive
  162.   neither generates nor detects parity. If W4 is not installed (the
  163.   factory default configuration), the drive generates parity and
  164.   enables parity detection. W4 is not installed most PC/AT
  165.   applications. Verify the correct configuration required by your
  166.   Host Adapter.
  167.  
  168. W21 Ground Options
  169.   W21(only implemented on Rev C and higher boards of the second
  170.   type shown) is used to connect the drive's logic ground to frame
  171.   ground. The factory default configuration, which should be used