  1.          M2511A 3.5 inch rewritable optical disk drive
  2.  
  3. Drive specifications
  4.     Item                                     Specification
  5. Optical disk cartridge                  90 mm optical disk cartridge 
  6.                     lSO standard format type A
  7. Total capacity  Unformatted             181 MB
  8.         Formatted               128 MB
  9. Capacity/track  Unformatted             18,100 bytes
  10.         Formatted               12,800 bytes
  11. Capacity/sector Unformatted             724 bytes
  12.         Formatted               512 bytes
  13. Number of user tracks/side              10,000 (*1)
  14. Number of alternate sectors/side        < or = 1,024
  15. Number of sectors/track                 25
  16. Data transfer rate                      1.1 MB/s (max.)
  17.                     0.256 MB/s continuous writing 
  18.                     (execution)
  19.                     0.768 MB/s continuous reading 
  20.                     (execution)
  21. Average seek time                       30 ms typ (*2)
  22. Average latency                         8.3 ms
  23. Rotational speed (Typical)              3,600 rpm +- 0.1%
  24. Heads                                   One-head on the positioner
  25. Positioner type                         Linear voice coil motor
  26. Servo tracking method                   ISO continuous composite method
  27. Density                                 24,400 BPI
  28.                     15,875 TPI
  29. Loading time (*3)                       5 sec.
  30. Unloading time (*4)                     3 sec.
  31. Load/unload life                        50,000 operations
  32. Interface                               SCSI-2
  33. Dimensions(WxDxH)                       101.6 x l46.0 x 25.4 mm
  34. Weight                                  550 g
  35. Power consumption                       10 W (reading or writing)
  36.  
  37. Controller Specifications
  38. Host interface                          SCSI-2 (Single-ended)
  39.                     Unshielded 50-contact connector
  40.                     Terminating resistor provided
  41.                     (Switch selectable On/OFF)
  42. Data transfer rate (*5)                 Synchronous mode: 4.0 MB/s (max.)
  43.                     Asynchronous mode:2.7 MB/s (max.)
  44.  
  45. Data buffer                     256 KB (read-ahead cache memory provided)
  46. Error correction                No latency time up to 4-byte/interleave
  47.                 Correctable up to 8-byte/interleave
  48.                 Bit error rate: 10-12 less (*6)
  49.  
  50.  
  51. Environmental and power requirements
  52.  
  53. Item                             Specification
  54. Power requirements:              + 5VDC +5% 2.0A (2.4AMax.)
  55.  
  56.  
  57. Power consumption:           
  58. During erasure                   10 W
  59. writing, or reading
  60.            
  61. During seek                      12 W Max.
  62.  
  63. Environmental Requirements  
  64.  
  65. Operating           Temperature: 5 to 45 C
  66.             (gradient 15 C an hour or less)
  67.             Relative humidity: 10 to 85% (Noncondensing)
  68.             Max. wet bulb temperature: 29 C or lower
  69.  
  70. Idle                Temperature:     0 to 50 C
  71.             Relative humidity: 10 to 85% (Noncondensing)
  72.             Max. wet bulb temperature: 36 C or lower
  73.  
  74. Transport           Temperature:     - 40 to 60 C (24 hours or less)
  75.             Temperature:     - 20 to 60 C (24 hours or more)
  76.             Relative humidity: 5 to 90% (Noncondensing)
  77.             Max. wet bulb temperature: 41 C or lower
  78.             Requirement: Packing conditions specified by Fujitsu
  79.  
  80. Vibration               
  81. Operating           0.3  G (5 to 500 Hz, sine sweep)
  82.             Shock 2   G (10 ms, half-sine pulse)
  83.  
  84. Idle                1.0  G (15 to 500 Hz, sine sweep)
  85.             Shock 5   G (1O ms, half-sine pulse)
  86.         
  87. Transport           Shock 50  G (10 ms, half-sine pulse)
  88.             Requirement: Packing conditions specified by Fujitsu
  89.  
  90. Altitude                
  91. Operating           3,000 m (10,000 ft) or less
  92.                 
  93. Idle                12,000 m (40,000 ft) or less
  94.  
  95. Ambient air         Air flow T.B.D.
  96.  
  97. purity              Air purity Office environment or better
  98.  
  99. *1 The number of user tracks indicates the maximum user zone which includes  
  100.    the spare area and slipping area.
  101.  
  102. *2 Figure 2.1 of Document 56FH5006E-AR outlines seek time (typical). Seek 
  103.    time does not include the address confirmation time. The average seek time 
  104.    may vary due to disk eccentricity in  the range from 25 to 35 ms.
  105.  
  106. *3 Loading time is the time from when the optical disk cartridge is inserted 
  107.    to when the optical disk drive is ready.
  108.  
  109. *4 Unloading time is the time from when the eject button is pressed or the 
  110.    eject command is issued to when the optical disk cartridge is ejected.
  111.  
  112. *5 The maximum SCSI data transfer rate may be limited by the initiator 
  113.    response  time, SCSI bus transfer characteristics, or transfer distance.
  114.  
  115. *6 The bit error rate must be 10-12 or less when a disk whose raw error rate 
  116.    is 10-4  or less is used.
  117.  
  118. Note: The current limiter of the 5 VDC power supply must activate before 
  119.       5 A are drawn.
  120.  
  121.     Settings
  122.          Before installing the drive in the system, set the following 
  123.          setting terminals and SCSI terminating resistors:
  124.  
  125.          . Setting terminal:  CNH 1
  126.          . Setting switch:    SW1, SW2
  127.  
  128.                       NOTICE
  129.  
  130.          1) The user must not change the settings of terminals not
  131.             described in this section. The terminals must remain as
  132.             set when shipped.
  133.  
  134.          2) Do not change terminal settings when the power is on.
  135.  
  136.          3) To strap setting terminals, use the jumper shipped with
  137.             the drive.
  138.  
  139.               Setting items are as follows:
  140.      (1)    SW1
  141.          .  SCSI ID
  142.  
  143.      (2)    SW2
  144.          .  SCSI data bus parity check
  145.          .  Synchronous transfer mode
  146.          .  Device mode
  147.          .  Spindle autostop mode
  148.          .  Power save mode
  149.          .  Factory examination mode (Not to be set by the user)
  150.          .  Reserved 1
  151.          .  Reserved 2
  152.  
  153.  
  154.  
  155. SCSI terminating resistor
  156.  
  157.     Enabling or disabling the SCSI terminating resistor function of the drive 
  158.     can be set by installing or removing the terminating resistor. The switch 
  159.     setting depends on the mounting location of the optical disk drive as 
  160.     follows:
  161.  
  162.     a)  When the drive is connected to either end of the SCSI cable:  
  163.     The SCSI terminating resistor must be installed.
  164.     
  165.     b)  When the drive is not connected to an end of the SCSI cable:  
  166.     The SCSI terminating resistor must be removed.
  167.  
  168.     Terminating Resistor Power Supply
  169.     
  170. CNH1    1 - 2  Power is supplied to the terminating resistor from the drive 
  171.            only.
  172.         
  173. CNH1    2 - 3  Power is supplied to the terminating resistor from the TERMPWR 
  174.            pin only. 
  175.                         
  176. To disable the Termination on the drive remove the terminating resistor 
  177. circuit from socket.
  178.  
  179. SW2 Option Settings
  180.  
  181. POS  DESCRIPTION                        OPTION
  182.  
  183. 1    SCSI Parity Checking             * ON = Parity Checking Enabled   
  184.                     OFF = Parity  Checking Disabled
  185.  
  186. 2    Synchronous Data Transfer          ON = Drive begins transfer of  SDTR      
  187.      Request                          * OFF = SDTR transfer disabled  
  188.  
  189. 3    Device Type Selection setting      ON = Removable MO - Disk Drive
  190.                       * OFF = Fixed Disk Non-Removable  
  191.  
  192. 4    Spindle Auto Stop Mode           * ON = Spindle will stop when idle      
  193.      "Power Save when idle"             OFF = Spindle always stays ON
  194.  
  195. 5    Page code 1 byte parameter page    ON = 10 byte parameter page length      
  196.      length Descriptor 6 or 10 byte   * OFF = 6 byte parameter page length  
  197.  
  198. 6    Factory TEST Execution with        ON = Factory Test with special disk     
  199.      Special Cartridge disk           * OFF = Normal Operating Mode     
  200.  
  201. 7    Report Unit Attention,  ANSI       ON = DO NOT report unit attn.   
  202.      SCSI Specification               * OFF = Report U.A. per ANSI Spec.
  203.  
  204. 8    Factory setting for Diagnostic     ON = Enable Sending Diagnostic 
  205.                       * OFF = Disable Run / Recieve diagnostic
  206.  
  207.  
  208.  
  209.  
  210. (1)    SCSI ID SW1                                                                        
  211.      SCSI ID settings of the drive.
  212.         
  213.     SCSI ID     Switch 2          Switch 3        Switch 4
  214.        0          OFF               OFF             OFF *   
  215.        1          OFF               OFF             ON
  216.        2          OFF               ON              OFF
  217.        3          OFF               ON              ON
  218.        4          ON                OFF             OFF
  219.        5          ON                OFF             ON
  220.        6          ON                ON              OFF
  221.        7          ON                ON              ON
  222.  
  223.     Note: SW1 position 1 is not used.
  224.           * = Factory default settings
  225.  
  226.  
  227. Air flow
  228.  
  229. An air flow is recommended in one of the three type shown on the depending on 
  230. the drive bezel. Two single bezel panel types and one double bezel panel are 
  231. available.
  232.  
  233. Note: Air flow temperature is 40_C and below. Dust condition is 0.15 mg/m3 
  234.       and below.
  235.  
  236.     
  237.     Type (1)
  238.  
  239.     Fan                     109P0412H302(SANYO), 12V,[]40mm
  240.     Filter                  G-0008W(SUMITOMO 3 M), dust collection rate 30%
  241.     Cleaning Cycle          6 months 
  242.     Air flow                0.05 m3/min
  243.  
  244.  
  245.     Type (2)
  246.  
  247.     Fan                     109P0412H302(SANYO), 12V,[]40mm
  248.     Filter                  G-0008W(SUMITOMO 3 M), dust collection rate 30%
  249.     Cleaning Cycle          6 months
  250.     Air flow                0.09 m3/min
  251.  
  252.     
  253.     Type (3)
  254.  
  255.     Fan                     MF40B(NIPPON-KEIKI), 5V,[]40mm
  256.     Cleaning Cycle          3 months
  257.     Air flow                0.07 m3/min
  258.  
  259.  
  260. Air purity
  261.  
  262. Air purity in the device environment is expressed by the number of dust 
  263. particles per unit area and must be class one million or less. 
  264. (Class one million: 1 million dust particles of 0.5 um dia. or larger 
  265. per cubic foot)
  266.  
  267. use the above fans and dust filter for the general office environment.
  268.  
  269. The head and disk should be cleaned every three months if the air purity 
  270. is about class one million.
  271.  
  272.  
  273. Installation Application Notes:
  274. All changes to switch settings are referenced to the factory default
  275. settings.
  276.  
  277. Macintosh: Switch 2 - Keys 3 & 7 =on
  278.            CNH1 - Pins 2 & 3 = short
  279.    ** PowerBook --> CNH1 - All 3 pins = short
  280.  
  281.  
  282. DOS:    
  283.     Adaptec AHA-154x and Data Technology DTC-3280AS respective host 
  284.     adaptor drivers need to be installed.
  285.     
  286.     Switch 2 - Keys 1, 3, 4, 5 = on
  287.     CNH1 - Pins 2 & 3 = short
  288.  
  289. SUN SPARCSTATION:
  290.  
  291.     Switch 2 - Keys 1 & 4 = on
  292.     CNH1 - Pins 2 & 3 = short
  293.  
  294.     Sun Format Parameters -> Data Cylinders = 9950
  295.                  Alternate Cylinders = 2
  296.                  Physical Cylinders = 9952
  297.                  Number of Heads = 1
  298.                  Sectors per Track = 25
  299.                  RPM = 3600
  300.