  4.  
  5.                            NOVELL INSTALLATION PROCEDURE
  6.  
  7.         Drive : Fujitsu M2613SA Winchester Disk Drive
  8.         Controller : Western Digital 7000 Fasst SCSI Host Adapter
  9.         -------------------------------------------------------------------
  10.                                        PART I
  11.         Drive and Controller Preparation :
  12.  
  13.         1.0.0  - Move the jumpers according to your  specific  configuration         
  14.                  (please refer to figure 2 ).  Install and attach all cables
  15.                  (i.e. 50 pin and power cable).
  16.         Note :  Jumper settings on the host adapter will vary from different
  17.         systems  and controllers installed.   Therefore,  careful  selection
  18.         must  be  taken to avoid incompatibility with other  controllers  or
  19.         option cards installed in the same system.
  20.  
  21.         1.0.1  -  Change  the  equipment configuration  in  cmos  ram  which
  22.                   reflects all equipments installed in the system and change
  23.                   the  hard  drive  configuration  for  "   no  hard   drive
  24.                   installed ".
  25.         Hint:
  26.           Here are a few examples on how to access the cmos ram setup:
  27.           AMI bios = " Press Del Key to enter set-up"
  28.           Phoenix  = " Ctrl + Alt + Enter or ESC "
  29.           Award    = " Ctrl + Alt + ESC "
  30.           Compaq   = Run setup from a Diagnostic Diskette included w/system
  31.           Others   = " Ctrl S, Alt S "
  32.         Note  :  System  should be rebooted  upon  completion  of  equipment
  33.         changes.
  34.  
  35.                                           
  36.                                       PART II
  37.  
  38.  
  39.         Create DOS Partition :
  40.  
  41.         Note: The following steps can also be done by using the SST software
  42.         that came with your hardware and following the reference manuals.
  43.  
  44.         2.0.0  - Create a small DOS partition.   Using either MS or PC  DOS,
  45.                  run   fdisk   to  create  a  partition  large   enough   to
  46.                  install  all netware work files temporarily  (approximately
  47.                  10-15  MB).   Perform  a dos format to  the  newly  created
  48.                  partition and reboot the system.
  49.                  
  50.         NOTE :
  51.           Make  sure that you have made a copy of the original  distribution
  52.         disks to be used as a set of working disks to do the installation.  
  53.  
  54.         2.0.1   -  Boot  from  the  hard  disk  and  create  the   following           
  55.                    sub-directories from the root directory.
  56.  
  57.         At the prompt, type :
  58.                        C:\> md generate [cr]
  59.                        C:\> cd generate [cr]
  60.                        C:\GENERATE> md netware [cr]
  61.         ╔
  62.         2.0.2    -  Install the device driver in their  proper  distribution  
  63.         disks.  For example :
  64.           Insert the SST DOS disk into drive A and 
  65.           a) COPY A:*.DSK TO THE NOVELL DISKETTE LABELED "AUXGEN"
  66.           b) COPY A:*.OBJ TO THE NOVELL DISKETTE LABELED "DSK_DRV_.001"
  67.  
  68.         2.0.3  -  Run Novell's netgen utility by typing the  following  line
  69.                   from  the  current  directory.   Insert  diskette  labeled
  70.                   NETGEN in diskette drive A: 
  71.         At the prompt, type :
  72.                        C:\GENERATE> a:netgen -n [cr]
  73.           At  this point NETGEN will be creating sub-directories within  the
  74.         NETWARE directory and copying all necessary files to select and link
  75.         all  required  resources (e.g.  device drivers)  according  to  file
  76.         server  configuration.   You will be prompted to insert the  correct
  77.         diskettes during this process.
  78.  
  79.         NOTE:
  80.           Due   to   specific  fileserver  configurations,   the   remaining
  81.         procedures should be referenced with the Novell Installation  Manual
  82.         for  more  greater detail in selecting proper  resources  (e.g.  Lan
  83.         cards, Printer definition and Operating System mode).
  84.  
  85.                                           
  86.                                       PART III
  87.  
  88.         Comprehensive Surface Analysis (Compsurf)
  89.  
  90.         3.0.0 - Run the compsurf utility which is in the UTILEXE-1
  91.                 (working) distribution disk after you have completed the
  92.                 initial setup, selection and linking of chosen resource
  93.                 sets.
  94.  
  95.         3.0.1 - The recommended responses to compsurf utility are as 
  96.                 follows :
  97.                     
  98.                 Format the disk ?                           No
  99.                 Maintain the current media defect list?     No
  100.                 Enter media defects?                        No
  101.                 Number of Sequential Passes                 0 
  102.                 ( this will depend on your confidence level)
  103.                 number of I/O's Random Test                 0
  104.                 Are these parameters correct?               Yes
  105.  
  106.         This  concludes  the hardware preparations.   Please  refer  to  the
  107.         Novell installation guide in completing the drive partitioning and 