home *** CD-ROM | disk | FTP | other *** search
/ Share Gallery 1 / share_gal_1.zip / share_gal_1 / GR / GR015A.ZIP / KINSTALL.DOC < prev    next >
Text File  |  1991-11-15  |  11KB  |  237 lines

  1.  
  2.  
  3.  
  4.  
  5.  
  6.  
  7.  
  8.  
  9.  
  10.                    KWIKSTAT VERSION 3 INSTALLATION PROCEDURES
  11.                    ==========================================
  12.  
  13.  
  14.      INSTALLING KWIKSTAT ON A HARD DISK
  15.  
  16.      If you already have a previous version of KWIKSTAT on your hard disk,
  17.      you should copy all .DBF files, and .IMG files and any other data
  18.      files you have created to a backup disk or directory. If you want to
  19.      preserve the complete old version of KWIKSTAT, make a new directory
  20.      called \KSOLD, copy all files from \KWIKSTAT to \KSOLD, then delete
  21.      all files in the original \KWIKSTAT directory. Once you have installed
  22.      KWIKSTAT, copy all of your .DBF, .IMG and other data files back onto
  23.      the \KWIKSTAT directory. All .DBF and .IMG files created under old
  24.      versions of KWIKSTAT are compatible with the current version.
  25.  
  26.      TO INSTALL KWIKSTAT ON YOUR HARD DISK, FOLLOW THESE STEPS:
  27.  
  28.      1.Turn on your computer and boot it in the usual way. End any programs
  29.      that are started automatically (such as a menu), so that you are at
  30.      the DOS prompt (usually a C> or C:\> prompt on a hard disk).
  31.  
  32.      The KWIKSTAT Basic system takes about 500K of disk space. To find out
  33.      if you have enough space on your hard disk, enter the command DIR at
  34.      the DOS prompt. You will see a message at the end of the directory
  35.      telling you how many bytes of free space are on your hard disk. You
  36.      should have 500,000 or more byes free before installing KWIKSTAT.
  37.  
  38.      2.Change the DOS prompt to drive A: by entering the command
  39.  
  40.       A:
  41.  
  42.      Your prompt should be A> or A:\>, or an equivalent prompt. (You may
  43.      also install from the B: drive if necessary, simply use B: instead of
  44.      A: in these instructions.)
  45.  
  46.      3. Insert KWIKSTAT disk (or disk 1 for 5.25 version) into drive A:.
  47.  
  48.      4. To begin the installation procedure for KWIKSTAT, enter the command
  49.  
  50.      INSTALL
  51.  
  52.      and press the Enter key. The first screen prompts you to verify that
  53.      you want to begin the installation procedure. If you do, type a Y and
  54.      press Enter. Entering N (No) will cancel the installation procedure.
  55.      --------------------------------------------------------------------
  56.                    Please Register by Printing the Order Form
  57.  
  58.  
  59.                                         1
  60.  
  61.  
  62.      KWIKSTAT 3 Installation Instructions
  63.      --------------------------------------------------------------------
  64.  
  65.  
  66.      5. The next screen asks you to verify what disk you will be installing
  67.      the program FROM. (That is, what disk drive contains the KWIKSTAT
  68.      installation diskette.) Usually it is A:. If you are installing from
  69.      another disk drive, use the backspace to erase the A: in the entry
  70.      area, and enter another drive name, such as B:.
  71.  
  72.      6. The next screen asks you to verify what disk you will be installing
  73.      the program TO. Usually it is C:. If you are installing to another
  74.      disk drive, use the backspace to erase the C: in the entry area, and
  75.      enter another drive name, such as D:.
  76.  
  77.      7. You will now be asked to verify the name of the directory where the
  78.      program will be installed. The default is \KWIKSTAT. If this is okay,
  79.      simply press Enter. If you want to store the program in another
  80.      directory, use the backspace to erase \KWIKSTAT and enter a new
  81.      directory name, such as \KS3.
  82.  
  83.      8. Before the actual installation takes place, a summary of your
  84.      choices is displayed on the screen, and you are prompted to verify
  85.      that they are correct. If they are correct, enter a Y and press Enter.
  86.      Choosing N (No) will cancel the installation procedure.
  87.  
  88.      9. The installation will begin copying files to the destination disk.
  89.      If you are using 5 1/4 inch disks, you will be prompted to change
  90.      disks mid-way through the installation process. Once the files are
  91.      copied to your hard disk, a setup procedure will begin. Go to the
  92.      section titled "Setup Procedures for KWIKSTAT".
  93.  
  94.      INSTALLING KWIKSTAT ON A 720K, 1.44M OR 1.2M INCH DISK
  95.  
  96.      KWIKSTAT may be run from a single floppy disk with at least 500K of
  97.      free space on disk. Copy the KWIKSTAT files from the original
  98.      distribution disk(s) onto a single disk. You may delete the *.DOC
  99.      files on your working disk to provide more space. Go forward in this
  100.      documentation to the section titled "Setup Procedures for KWIKSTAT."
  101.  
  102.      INSTALLING KWIKSTAT ON A TWO-FLOPPY 5.25 INCH 360K SYSTEM
  103.  
  104.      To install KWIKSTAT on a two-floppy 5.25 inch disk system you must
  105.  
  106.      first format 3 blank diskettes. (Refer to your DOS manual or
  107.      Appendix C if you do not know how to format a diskette.) Label your
  108.      disks Working disk 1, Working disk 2 and KWIKSTAT data disk.
  109.      Place the original KWIKSTAT disk 1 in the A: drive and your blank
  110.      formatted Working Disk 1 into drive B: and enter the following
  111.      command at the DOS prompt:
  112.  
  113.       FLOPPY
  114.      --------------------------------------------------------------------
  115.                    Please Register by Printing the Order Form
  116.  
  117.  
  118.                                         2
  119.  
  120.  
  121.      KWIKSTAT 3 Installation Instructions
  122.      --------------------------------------------------------------------
  123.  
  124.  
  125.      Follow the prompts on the screen. These prompts will lead you through
  126.      copying the appropriate files to the two working disks and the data
  127.      disk. Once all three disks are created, place the Working disk 1 in
  128.      the A: drive and the data disk in the B: drive. Begin the setup
  129.      procedure by entering the following command at the DOS prompt:
  130.  
  131.       KSETUP
  132.  
  133.      To set up KWIKSTAT, follow the instructions in the section titled
  134.      "Setup Procedures for KWIKSTAT". Note: In the setup procedure, when
  135.      you are prompted to enter the default path where DBF files will be
  136.      stored, enter B:\ as your choice. This tells KWIKSTAT to use the B:
  137.      disk as the storage disk for data files. You must have the data disk
  138.      in the B: drive whenever you are running KWIKSTAT. Note: When running
  139.      KWIKSTAT on a two-floppy system and choose an option from the Analyze
  140.      pull-down menu that is not on disk 1, a message will appear on the
  141.      screen telling you to switch disks. Take disk 1 out of the A: drive
  142.      and place disk 2 in the A: drive, then press Enter. Once you finish
  143.      with the module on disk 2, you will be prompted to switch the disk in
  144.      A: back to disk 1.
  145.  
  146.      SETUP PROCEDURES FOR KWIKSTAT
  147.  
  148.      The setup procedure tells KWIKSTAT information it needs to know to run
  149.      on your computer. (If you are not already in the setup procedure,
  150.      begin setup by typing KSETUP at the DOS prompt.) The following
  151.      information is requested. Usually, you will be able to simply press
  152.      Enter to choose the default value.
  153.  
  154.      A. Enter the default path where DBF files will be stored. Usually, you
  155.      will simply press Enter to tell KWIKSTAT that you will be storing DBF
  156.      files in the same directory as the program. However, if you want to
  157.      store your database files in another directory such as \DB3, enter
  158.      \DB3 as the path to use. Make sure that the directory you enter
  159.      exists. If you specify a non-existent directory, it will cause an
  160.      error when the program tries to read or write to that directory. (See
  161.      the DOS tutorial on how to make a directory.) On a two 360K floppy
  162.      based system, enter B:\ as your default directory to store database
  163.      files.
  164.  
  165.      B. Indicate the kind of monitor you are using. The choices are
  166.  
  167.        No graphics monitor
  168.        CGA, EGA, VGA, PGA, Composite or CGA compatible
  169.        Hercules (monochrome graphics)
  170.  
  171.      Use the up and down arrow keys to highlight your monitor type, and
  172.      press Enter. If your monitor will display color, you will usually
  173.      --------------------------------------------------------------------
  174.                    Please Register by Printing the Order Form
  175.  
  176.  
  177.                                         3
  178.  
  179.  
  180.      KWIKSTAT 3 Installation Instructions
  181.      --------------------------------------------------------------------
  182.  
  183.      choose the "CGA..." option.
  184.  
  185.      C. Indicate your printer type. A list of supported printers will be
  186.      displayed. Use the up and down arrow keys to select the printer most
  187.      like what you use, and press Enter. Many printers emulate the EPSON
  188.      (if they are dot matrix) or the HP Laserjet (if they are laser
  189.      printers). If your printer does not appear on the list, check your
  190.      printer manual to see if it emulates one of the printers listed.
  191.  
  192.      D. Indicate your printer port. The printer port tells the PC what port
  193.      to use when sending information to the printer. The most common port
  194.      used is LPT1: (Line printer 1). If you only have one line printer
  195.      (parallel) port, this is probably what you will choose. Some printers
  196.      use COM ports (serial ports). Use the up and down arrow keys to choose
  197.      the port your PC uses, and press Enter.
  198.  
  199.      E. Choose menu colors. The color selection menu contains nine color
  200.      selections. (Options 1,2, and 3 are for single color monitors.) Choose
  201.      the one you like best by entering a number 1 through 9 at the prompt,
  202.      and press Enter. You can change this selection (and all other
  203.      selections in the setup) later from the main menu of the program.
  204.  
  205.      F. Write setup info to disk? Once you have chosen your options, you
  206.      are asked if you want to save these options to disk. Usually, you
  207.      should enter a Y and press Enter. This saves the information to disk
  208.      so the program will remember your selections next time you begin the
  209.      program. If you answer No, this information is not saved. You may
  210.      enter new selections or change any current selections from the Helps
  211.      pull-down menu. Once you have made your setup selections, you are
  212.      returned to the DOS prompt. You should store the original diskettes in
  213.      a safe place. To begin KWIKSTAT, enter the command KS at the DOS
  214.      prompt.
  215.  
  216.  
  217.      PRINTING THE DOCUMENTATION ON DISK
  218.  
  219.      To print the disk version of the manual, place the distribution disk
  220.      in the A: drive with A as the DOS prompt, and enter the command
  221.  
  222.      PRINTDOC KS.DOC
  223.  
  224.      To print the LATENEWS.DOC file, use the command
  225.  
  226.      PRINTDOC LATENEWS.DOC
  227.  
  228.  
  229.  
  230.  
  231.  
  232.      --------------------------------------------------------------------
  233.                    Please Register by Printing the Order Form
  234.  
  235.  
  236.                                         4
  237.