home *** CD-ROM | disk | FTP | other *** search
/ Share Gallery 1 / share_gal_1.zip / share_gal_1 / CO / CO004.ZIP / PC-VT100.ZIP / README.V10 < prev    next >
Text File  |  1990-05-19  |  12KB  |  290 lines

  1.               _______
  2.          ____|__     |               (tm)
  3.       --|       |    |-------------------
  4.         |   ____|__  |  Association of
  5.         |  |       |_|  Shareware
  6.         |__|   o   |    Professionals
  7.       -----|   |   |---------------------
  8.            |___|___|    MEMBER
  9.  
  10.         Mark C. DiVecchio
  11.          Athena Systems Development Group
  12.  
  13. PC-VT Version 10.0                                  January 6, 1990
  14.  
  15. ===========================================================================
  16.  
  17.     Notes on Version 10.00 of PC-VT
  18.  
  19. The underlying functionality of PC-VT has not changed so the manual has
  20. not changed. What has been added are the features most requested by
  21. the users of PC-VT over the past year.
  22.  
  23. We feel that this version of PC-VT is easier to use and more accurately
  24. emulates the VT and 401x series of terminals.
  25.  
  26. ===========================================================================
  27.  
  28. Installation Instructions :
  29.  
  30. If you are a new user of PC-VT, just copy all of the files from the root
  31. directory of the diskette to either a working diskette or to your hard
  32. disk. If you are copying it to your hard disk, make sure that the
  33. directory you install it into is in the 'path=' environment variable.
  34.  
  35. We usually install PC-VT in a subdirectory '/pc-vt' and then add the
  36. following two lines to our autoexec.bat
  37.  
  38. path <original path>;c:\pc-vt
  39. set pc-vt=c:\pc-vt
  40.  
  41. If you have been using PC-VT Professional version 1.00, then copy only
  42. PC-VT.EXE, HELP.DAT, UTIL.EXE, and DSZ.COM to your already existing
  43. PC-VT directory ( remember, you have get the UTIL.EXE program from the
  44. utility subdirectory and unarchive it with ARCE). Then run UTIL to
  45. take your existing 10 entry dialing directory and enlarge it to 100
  46. entries. See the section on enhanced features to learn more about the
  47. 100 entry dialing directory.
  48.  
  49. If you have been using PC-VT User Supported Software version 9.0d, then
  50. copy only PC-VT.EXE, HELP.DAT, PARAMS.DAT, DIALER.DAT, MACRO.DAT,
  51. UTIL.EXE, and DSZ.COM to your already existing PC-VT directory. You will
  52. have to manually reconstruct your Dialer Directory.
  53.  
  54. ===========================================================================
  55.  
  56. Enhanced features of PC-VT version 10.0 :
  57.  
  58. ===========================================================================
  59.  
  60. The dialer has been enlarged to 100 entries. Now in the dialer frame,
  61. the PgUp and PgDn keys will page through the 100 entries, 10 per screen.
  62. If you have version 1.0 of PC-VT, there is a program named UTIL.EXE
  63. which will take your dialer and add 90 more blank entries to it without
  64. changing the first 10. If you use the /dnnn option to dial from the
  65. command line, nnn can be a host number from 1 to 100.
  66.  
  67. Use the <PgUp> and <PgDn> keys to page through the dialer. For automatic
  68. command line dialing, the first entry is host 1 and the last entry is
  69. host 100. Each pages displays the host number of the first host shown on
  70. that page.
  71.  
  72. ===========================================================================
  73.  
  74. ZMODEM and YMODEM are now supported using the external DSZ program from
  75. Omen Technology, Inc. We are including a copy of the DSZ program on the
  76. diskette as a service. We are in no way affiliated with Omen Technology.
  77. DSZ is a User Supported Program. We encourage you read the DSZ
  78. documentation file to find out about the program. PC-VT automatically
  79. calls the DSZ program when you select either ZMODEM or YMODEM protocol.
  80.  
  81. PC-VT does this by forking off the DSZ.COM program which is on the
  82. distribution diskette, in the archive DSZ.ARC in the DSZ subdirectory.
  83. YMODEM is selected by the '=y' option and ZMODEM is selected by the '=z'
  84. option. The old ASCII CTRL-Z file transfer method is now selected with
  85. '=Z'.
  86.  
  87. You can select a default file transfer protocol on the SETUP B frame.
  88. If ZMODEM is selected, when you do a file receive, <CTRL><F3>, the popup
  89. to ask for the local filename is bypassed since ZMODEM protocol requires
  90. that the sending computer include the name of the file. This means that
  91. the name of the file will not change when receiving a file from a remote
  92. computer.
  93.  
  94. Conversely, when you send a file, the receiving computer on the other
  95. end, will not ask you for a file name. Rather, when you press <CTRL><F4>
  96. on the PC, PC-VT will ask you for the name of file on the PC which you
  97. want to upload and that filename will be passed to ZMODEM.
  98.  
  99. ===========================================================================
  100.  
  101. PC-VT Supports COM3 and COM4 for serial communications
  102.  
  103.     This is selectable via the same feature selection item on the
  104. SETUP B frame as in older versions of the program.
  105.  
  106.     The SETUP frame will show a number 0 through 3 and the COM name
  107. shown just above that will show the actual value of the serial port
  108. which is selected.
  109.  
  110.     To use COM3 or COM4, your version of DOS must support these
  111. devices with these interrupt numbers and port addresses :
  112.  
  113. PORT    IRQ    ADDR    interrupt
  114.             vector
  115. ----------------------------
  116. 1    4    3F8    0C    ; standard COM1
  117. 2    3    2F8    0B    ; standard COM2
  118. 3    4    3E8    0C    ; new COM3
  119. 4    3    2E8    0B    ; new COM4
  120.  
  121. ===========================================================================
  122.  
  123. The printer escape sequences are handled more like a VT terminal.
  124. Sequences received while the local printer is enabled, will be sent to
  125. the printer. This will permit you to include printer control escape
  126. sequences in the information sent from the host computer to your local
  127. printer.
  128.  
  129. ===========================================================================
  130.  
  131. In the SETUP B frame the 's' key now performs the "STORE SETUP DATA to
  132. USER MEMORY" just like the 's' key in the SETUP A frame.
  133.  
  134. ===========================================================================
  135.  
  136. You can move from the Dialing Directory to the SETUP A frame by pressing
  137. <CTRL><F1> in the Dialing Directory. Pressing <Esc> in the SETUP frame
  138. will return you to the Dialing Directory. Pressing <Esc> again will
  139. return you to the communication frame.
  140.  
  141. ===========================================================================
  142.  
  143. A shortcut has been added to the selection of the communications port.
  144. In the SETUP B frame the 'c' key now toggles the COM port selected. This
  145. works just like toggling the feature bit on the bottom of the screen but
  146. is easier to do.
  147.  
  148. ===========================================================================
  149.  
  150. For those with unusual requirements, PC-VT can use a communications port
  151. just as it finds it without changing the baud rate or data bits. Select
  152. this in the SETUP B frame as a baud rate selection of "INIT". This option
  153. replaced the old 110 baud setting which is no longer supported.
  154.  
  155. ===========================================================================
  156.  
  157. PC-VT does a better job of emulating the escape sequences to the local
  158. printer. Previously, escape sequences where filtered out before
  159. characters were sent to the printer. Now they are handled like the VT100
  160. and passed on to the printer.
  161.  
  162. Technically, once print_only is turned on,
  163.  
  164.     1. all escape sequences go to printer and are not acted upon by
  165. the emulator
  166.  
  167.     2. except <ESC>[4i which turns off printer only mode.
  168.  
  169. ===========================================================================
  170.  
  171. PC-VT now handles LPT1 through LPT4 and COM1 through COM4 for the
  172. printer port.
  173.  
  174. This is selectable via the same feature selection item on the SETUP B
  175. frame as in older versions of the program. Be sure that you don't select
  176. the same COM port as PC-VT is using for Host communications.
  177.  
  178. The SETUP frame will show a number 0 through 7 and the printer name
  179. shown just above that will show the actual name of the printer which is
  180. selected for output.
  181.  
  182. To use LPT3, LPT4, COM3 or COM4, your version of DOS must support these
  183. devices.
  184.  
  185. If you want to use one of the COM ports for a printer, the DOS MODE
  186. command must be executed before running PC-VT to initialize the port
  187. parameters. This is normal operations for systems using a serial
  188. printer.
  189.  
  190. For example :
  191.  
  192.     mode com2:96,n,8,1,p
  193.  
  194. Most users of serial printer already have this command in their
  195. autoexec.bat file. Check your DOS manual for instructions on how to use
  196. this command.
  197.  
  198. The printer port is saved with each phone number so that if you add
  199. another host, be sure to change the printer port to the one you want.
  200.  
  201. PC-VT polls the serial printer continuously just like the 'p' option on
  202. the DOS MODE command.
  203.  
  204. ===========================================================================
  205.  
  206. RTS/CTS flow control has been added. It is selectable from the flow
  207. control feature selection on the SETUP B frame. You can select NONE,
  208. XON/XOFF (the most useful), and RTS/CTS.
  209.  
  210. ===========================================================================
  211.  
  212. In some cases, the  <Esc> interpret/display switch did not work
  213. correctly. That is now fixed.
  214.  
  215. ===========================================================================
  216.  
  217. The <Esc> key now cancels filename and directory entries.
  218.  
  219. ===========================================================================
  220.  
  221. In the Dialer, no carriage return is sent to the modem if the dialer
  222. command line is completely blank or if the CTRL-X character is in the
  223. first position of the line.
  224.  
  225. ===========================================================================
  226.  
  227. In the Dialer and in the Macro key processor, a new, command, CTRL-6,
  228. drops DTR for 1 second. Displays as a solid triangle.
  229.  
  230. In the Dialer, if first character in number is CTRL-X or blank, don't
  231. send any dial characters.
  232.  
  233. ===========================================================================
  234.  
  235. The ALT-L key was changed to toggle application keypad mode on and off.
  236. Only needed if you have special requirements.
  237.  
  238. ===========================================================================
  239.  
  240. Added a SETUP feature to disable PC-VT Private Sequences. Some users
  241. with some VAX software had trouble with these. If you use this with an
  242. old copy of DIALER.DAT, it will default to enabled unless you change it.
  243. The sequences disabled include COLOR support, "<ESC> [ ? x h" and "<ESC>
  244. [ ? x l" with x greater than or equal to 21 and the "<ESC> [ ? x n" with
  245. x equal to 10 or 11. 
  246.  
  247. ===========================================================================
  248.  
  249. PC-VT had a problem running KERMIT out of COM2. This is now corrected.
  250.  
  251. ===========================================================================
  252.  
  253. PC-VT will now accept both '/' and '-' as command line flags. For
  254. example :
  255.     pc-vt/d1
  256.  
  257.     and
  258.  
  259.     pc-vt -d1
  260.  
  261. are identical. Notice that if you use the dash, you must put a space
  262. between the program name the command line option.
  263.  
  264. ===========================================================================
  265.  
  266. PC-VT had to work around a bug in the VMS version of WordPerfect. If you
  267. have that program running under VMS, select option 2 of the 'PC-VT
  268. Private Escapes' feature (which is the first feature in the first group)
  269. on the SETUP B screen. This disables the '<ESC>[?25l' and '<ESC>[?25h'
  270. PC-VT Private Escape Sequences. I don't understand why WordPerfect
  271. decided to use these sequences. A real VT-100 would ignore them so
  272. nothing is gained.
  273.  
  274. ===========================================================================
  275.  
  276. Special editor support has been added for Emacs running under SCO Xenix.
  277. If you have need for that editor and the patches to it necessary to use
  278. the entire keyboard while running PC-VT contact us.
  279.  
  280. ===========================================================================
  281.  
  282. Thanks for your support of PC-VT. If you have any questions, you can
  283. call me direct at (619) 549-4056 or call the Athena Systems Computer
  284. Bulletin Board at (619) 549-3927.
  285.  
  286. Mark C. DiVecchio
  287. President
  288. Athena Systems Development Group
  289. ===========================================================================
  290.