home *** CD-ROM | disk | FTP | other *** search
- ------------------------------------------------------------------
- Microsoft Windows 95 README for Networks
-
- August l995
- ------------------------------------------------------------------
-
- (c) Copyright Microsoft Corporation, 1995
-
-
- This document provides complementary or late-breaking information to
- supplement the Microsoft Windows 95 documentation.
-
-
- ------------------------
- How to Use This Document
- ------------------------
-
- To view Networks.txt on screen in Notepad, maximize the Notepad window.
-
- To print Networks.txt, open it in Notepad or another word processor,
- and then use the Print command on the File menu.
-
-
- ---------
- CONTENTS
- ---------
- Client for NetWare
- Plug and Play Network Cards and 16-Bit Real-Mode Drivers
- Intel EtherExpress 16 NICs and PCI Computers
- Windows for Workgroup Shares
- Running Windows 95 from a Server
- Support for Third-Party Networks
- Printing to a Network Printer
- Problems Printing to PostScript Printers over a NetWare Network
- Issues and Installation of MSDLC with Windows 95
- Microsoft TCP/IP Protocol
- User Profiles over the Network
- Network Backup Agents
- Real-Mode Protocols: Warning Icons on Your Network Adapter
- Using an IBM Thinkpad with a Dock II
-
-
-
- Client for NetWare
- ==================
-
- Windows 95 and NetWare 3.12 and 4.01 Servers
- --------------------------------------------
- Windows 95 with Microsoft Client for NetWare can experience problems
- with NetWare 3.12 and 4.01 servers if packet burst is turned on.
- This is a known problem with these servers that Novell has fixed and
- posted on their forums. Download the file Pburst.exe from the Novell
- Netwire Forum on Compuserve or the Novell Web site (Ftp.Novell.com).
- Pburst.exe contains the patch for the affected servers.
-
-
- Opening Files on NetWare 3.11 Servers
- -------------------------------------
- Programs that open a large number of files consecutively in rapid
- succession may have occasional problems opening files on NetWare 3.11
- servers. This can also happen when opening a file in a folder for which
- you do not have file scan rights, such as an MS Mail shared post office.
-
- Possible error messages:
-
- - "File not found" error on a file you know exists
- - "Sharing violation" or "Lock violation" error
- - "Unable to open file" error
- - "File in use" error
-
- There are two solutions to these problems:
-
- -- Obtain a patch file from Novell for the NetWare 3.11 server.
- Using ftp, connect to ftp.novell.com. Go to
- /pub/netware/nwos/nw311/osnlm and run 311ptd.exe. This program
- will extract the file os2opnfx.nlm. Then, load the .nlm file
- onto the NetWare 3.11 server. ("load os2opnfx.nlm")
-
- -- Disable long filename support in Client for NetWare. This means
- that you will not be able to use long filenames on any NetWare
- servers from Windows 95. To disable long-filename support:
-
- Run REGEDIT, and then go to
- HKEY_Local_Machine\System\CurrentControlSet\Services\VxD\NWRedir
- Create a new binary value whose name is supportLFN and whose
- value is 0.
-
-
-
- Lowercase Extended-Character Passwords on NetWare 4.1 Servers
- -------------------------------------------------------------
- In a NetWare 4.1 environment, Client for NetWare does not support
- passwords that use certain lowercase extended characters. Users need to
- change their password to all uppercase characters.
-
-
- Client for NetWare and Programs That Use External Files
- -------------------------------------------------------
- If you are using Microsoft Client for NetWare, and you run a program that
- needs to access an auxiliary file, your program will have problems if
- the auxiliary file is on a drive other than the one the program is on.
- This is because only the current drive is searched for auxiliary files;
- the search path is not searched. If you experience this problem,
- make sure the program and any auxiliary files are on the same drive.
-
-
- Novell NetWare Login Scripts
- ----------------------------
- The Login Script Processor for the Microsoft Client for NetWare should
- correctly process all commands in your login scripts. However, you
- cannot load memory-resident programs (TSRs) from these scripts.
-
-
-
- Plug and Play Network Cards and 16-Bit Real-Mode Drivers
- ========================================================
-
- When you run the 16-bit real-mode driver for your Plug and Play network
- interface card (NIC), your Plug and Play card may appear not to function.
-
- The reason the card appears to malfunction is that on most computers,
- the Plug and Play card is inactive until Windows 95 enables it. 16-bit
- NIC drivers load before Windows 95 can turn on Plug and Play cards. Some
- 16-bit NIC drivers do not recognize Plug and Play cards (most NE2000 Plug
- and Play clones fall into this category). In this case, follow these
- steps to use your Plug and Play card with a 16-bit NIC driver:
-
- 1. Run the Softset utility that comes with your Plug and Play card, and
- then set the card to non-Plug and Play mode.
- 2. Remove the network card from the list of devices in the Device Manager
- listing: In Control Panel, double-click the System icon, click the Device
- Manager tab, select the network card, and then click Remove.
- 3. Reinstall the network card using the Add New Hardware icon in Control
- Panel.
-
- When you install a 32-bit protect mode NIC driver in the future, you can
- rerun Softset to turn on Plug and Play mode for your card. This problem does
- not happen if you are using a 32-bit protect-mode NIC driver.
-
-
-
- Intel EtherExpress 16 NICs and PCI Computers
- ============================================
-
- If you are using an Intel EtherExpress 16-network interface card (NIC)
- in a PCI computer that has a Diamond Speed Star PCI video card, your
- system may hang or not initialize properly. These problems, according
- to Intel customer support, are not related to Windows 95 and happen
- on a variety of operating systems.
-
- If you have one of the following video cards, contact your vendor to
- obtain a new video BIOS update:
-
- * Diamond Speed Star PCI video card with BIOS version 1.01
- * Diamond Viper PCI VGA Video Adapter
- * Diamond Stealth video card, BIOS v1.03
-
- Other PCI video cards might also cause problems with this Intel NIC.
- In general, if you experience problems with your EtherExpress 16 in a PCI
- computer other than those described above, please replace the card before
- reporting the problem to Microsoft.
-
-
- Windows for Workgroup Shares
- ============================
-
- When you upgrade to Windows 95 from Windows for Workgroups, your shares
- are not maintained. The folders/directories you shared in Windows for
- Workgroups need to be reshared.
-
-
- Running Windows 95 from a Server
- ================================
-
- Windows 95 can be set up to run from a network server. The Windows 95
- Resource Kit contains complete instructions for installing Windows
- in this environment (see Chapter 4, "Server Based Setup for Windows 95").
-
- The following configurations are supported:
-
- -- Booting from hard disk using:
- Client for Microsoft Networks
- Client for NetWare Networks
- Novell Workstation Shell 3.x (NETX)
- Novell Workstation Shell 4.x (VLM)
- Banyan VINES DOS/Windows client
-
- -- Booting from a floppy disk using:
- Client for Microsoft Networks
- Client for NetWare Networks
- Novell Workstation Shell 3.x (NETX)
- Novell Workstation Shell 4.x (VLM)
- Banyan VINES DOS/Windows client
-
- -- Booting from a remote boot server using:
- Client for NetWare Networks
- Novell Workstation Shell 3.x (NETX)
- Novell Workstation Shell 4.x (VLM)
-
- To use one of the Microsoft clients, your network card must have both an
- NDIS2 (16-bit real mode) *AND* an NDIS3 (32-bit protect mode) driver.
- If your network card is a PCI, EISA, or ISAPNP card, you must run
- Windows over a real-mode client.
-
-
- To Install Windows 95 over Previous Builds
- ------------------------------------------
- To install this final version of Windows 95 on network computers that are
- already running Windows 95, you have two options: 1) Do a clean install
- on each computer; or 2) Upgrade each computer using the following
- procedure:
-
- 1. Shut down any clients running from the server.
- 2. Windows 95 must be installed on the server into the same folder that
- you were using for previous builds. Delete everything in the shared
- Windows 95 folder, and then run Netsetup.exe to install this build
- into that folder.
- 3. Restart the client to a command prompt.
- 4. If you are using the Microsoft Client for NetWare Networks and use map
- rooted drives, you must start either NETX or VLM to run Setup.
- 5. Map drives to the machine folder and shared Windows 95 folder
- as before. These must use the same drive letters as used in the
- previous build, and map roots should be to the same folder level.
- 6. Run Setup for the new build.
-
-
- Support for Third-Party Networks
- ================================
-
- To install support for a third-party, real-mode network, you must be running
- the network when you run Windows 95 Setup. Windows 95 does not support
- installation of a real-mode network after Setup, unless you have a
- Windows 95-specific .inf file from your network vendor. For example, FTP
- includes a Windows 95 .inf in their 32-bit NFS client. Although Windows 95
- supports other networks, network component files for networks other than
- Microsoft networks are not included with Windows 95. You must already have
- the files for the network you want to install.
-
- LANDESK 2.0
- -----------
- LANDESK version 2.0 uses a TSR named Usertsr.exe that may cause Windows 95
- to stop responding when you use the Microsoft IPX/SPX-compatible protocol
- (Nwlink.vxd) or file and printer sharing for Microsoft Networks (Vserver.vxd).
-
- LANDESK version 2.01 fixes this problem, and the patch is available on
- Intel's BBS or from Intel product support. For the BBS and product support
- telephone numbers, consult the documentation that came with your copy of
- LANDESK.
-
-
- SunSelect PC-NFS
- ----------------
- Windows 95 supports versions 5.0 or greater of SunSelect PC-NFS.
- If SunSelect PC-NFS is installed using an NDIS 2 LAN driver or an ODI
- LAN driver, then SunSelect PC-NFS can be installed as an additional
- 16-bit network client along with 32-bit protected-mode clients. If you
- are using a SunSelect PC-NFS LAN Driver, Windows 95 can support PC-NFS
- only as the primary network. Additional 32-bit network providers are not
- possible in this case.
-
-
- Banyan VINES
- ------------
- If you see a message during startup that the VINES version is not the
- latest, edit the Vines.ini file in the Windows folder so it contains
- the following lines:
-
- [NEWREV]
- dontcopy=1
- vines.version=5.5x (x) USA ; where x=your version
- windows.version=3.95
-
- If you receive the message, "Vines NDIS Interface error: 1021. See
- NDISBAN.DOC for an error description," during startup, run the VINES
- utility PCCONFIG to change Banyan drivers to NDIS drivers. Also, make
- sure the section name matches the driver name in the Protocol.ini file.
-
-
- DEC Pathworks
- -------------
- Windows 95 provides support for upgrading over existing DEC
- PATHWORKS V5.0, V5.0A and V5.1 configurations. This makes it possible
- to run your existing real-mode PATHWORKS components while migrating
- to Windows 95. However, it is strongly recommended that you upgrade
- to DEC's PATHWORKS for Windows 95, which contains protected-mode
- components.
-
- Restrictions
-
- PATHWORKS must be started before running Windows 95 Setup to automatically
- detect and upgrade PATHWORKS components. If PATHWORKS is not started
- or is not automatically detected, you will see startup errors when you
- run STARTNET. To correct this, add the appropriate "PATHWORKS V5.0 and
- above" protocol, using the Network icon in Control Panel.
-
- Once a system has been upgraded to Windows 95, you cannot change your
- PATHWORKS configuration using PWSETUP. However, all existing template
- configurations present when you upgrade are converted to work under
- Windows 95.
-
- PATHWORKS Native, DLC, X.25, and ISDN datalinks are converted to use
- an NDIS driver, if available, during the upgrade. If the replacement
- NDIS driver is not configured correctly or is not operating, startup
- will display an error and prevent loading of other PATHWORKS components.
-
- To correct this, double-click the Network icon in Control Panel, and
- verify that the adapter driver is configured correctly. If any changes are
- made to the adapter configuration, you must remove the "PATHWORKS V5.0
- and above" protocol and add it again.
-
- PATHWORKS NetWare client licenses (CCS or FPA) are not currently
- supported with Windows 95. If you are using the Microsoft Client for
- NetWare Networks to connect to PATHWORKS for OpenVMS (NetWare) or
- PATHWORKS for OSF/1 (NetWare) servers, the server must have PATHWORKS
- FPS licenses.
-
- Long filenames do not work correctly on PATHWORKS servers up to and
- including version 5.0b. You will be able to create and delete LFN files
- and make and remove LFN folders, but the files and folders will not appear
- when you use the DIR command, or when you open an Explorer window to the
- PATHWORKS server. PATHWORKS server version 5.00 EC01 corrects this
- problem and is available from DEC.
-
-
- Artisoft LANtastic
- ------------------
- The LANtastic server cannot be run when Windows 95 is setting up.
-
- LANtastic also cannot be run in conjunction with networking support
- for other networks.
-
-
- Printing to a Network Printer
- ==============================
- You may have problems setting up a printer that is shared by a third-party
- network server. The solution is to redirect LPT1 through an MS-DOS
- window to the third-party share, and then use the printer setup for LPT1.
-
- For example, if a network printer is connected to LPT1, follow these steps:
-
- 1. At the MS-DOS prompt, type:
-
- net use lpt1: \\servername\sharename
-
- (This command may be different on the network you are using.
- Check the product documentation to find out how to redirect
- an LPT port.)
-
- 2. Start Control Panel, double-click Printers, and then double-click Add
- Printer.
-
-
- Problems Printing to PostScript Printers over a Netware Network
- ===============================================================
- If you have problems when printing to a PostScript printer over a network,
- (error messages on the printer; no output is printed), it may be due to
- incorrectly configured Banner Pages. To solve this problem, you can either
- 1) Disable banner pages by removing the check mark from the Banner Pages box
- on the Capture printer properties (open the Printers folder, click the
- icon for the printer you are using, and then click Properties on the File
- menu); or 2) Ask your network administrator to correctly configure
- banner pages on the Netware server for a PostScript printer.
-
-
-
- Issues and Installation of MS-DLC with Windows 95
- -================================================
-
- Windows 95 contains MS-DLC and support for installing over an existing
- MS-DLC or IBM-DLC installation. Setup will detect DLC and make the
- appropriate changes to your configuration files for these. Refer to
- the Windows 95 Resource Kit, Chapter 10, for a complete description
- of DLC support.
-
-
- Microsoft TCP/IP Protocol
- =========================
-
- If Microsoft's TCP/IP is the only protocol you have loaded on your
- system, the IP Address will not be added during Setup. If you have
- a DHCP server, open Control Panel, double-click the Network icon, and
- then close it. This will update the IP Address. (If you don't know if you
- have a DHCP server, check with your network administrator, or check
- if your IP address is already entered.)
-
- If you don't have a DHCP server, start Control Panel, double-click
- the Network icon, double-click TCP/IP, click the IP Address tab, and
- then enter your IP Address.
-
- If you are not updating from a previous Windows 95 installation (you
- are doing a "clean install"), to use DNS or LMHOSTS name resolution,
- make sure you have DNS enabled in the Network properties. To enable
- DNS, double-click the Network icon in Control Panel, double-click TCP/IP,
- click the DNS configuration tab, and then click Enable DNS.
-
-
- User Profiles over the Network
- ==============================
-
- If you are using user profiles over a Windows NT or Novell NetWare
- network, and you include Start Menu/Programs, Network Neighborhood,
- and/or desktop icons in your profile, the server must have long
- filename support to ensure that these parts of the user profile work
- over the network.
-
-
- Network Backup Agents
- =====================
-
- Arcada Backup Exec Network Backup Agent
- ---------------------------------------
- To use the Arcada Backup Exec network backup agent included in
- Windows 95, you must have Arcada Backup Exec version 5.x.
-
-
- Cheyenne ARCserve Network Backup Agent
- --------------------------------------
- To use the Cheyenne ARCserve network backup agent included in Windows 95,
- you must have Cheyenne ARCserve version 5.01F. You may also use earlier
- versions if you obtain updated NLMs from Cheyenne Software.
-
-
-
- Real-Mode Protocols: Warning Icons on Your Network Adapter
- ==========================================================
- If you install a network that does not use protected-mode protocols,
- such as Novell Netware 3.x, you may see a yellow warning icon next to
- your network adapter in Device Manager. You can ignore this warning;
- your network is fully functional. To remove the warning icon, use the
- program, Extract.exe on Setup disk 1 to extract the file Ndis.vxd from
- your Windows 95 disks. Then, copy Ndis.vxd into your Windows\System folder.
- When you reboot your system, the yellow warning icon will no longer
- appear.
-
-
- Using an IBM Thinkpad with a Dock II
- ====================================
- If you enable 32-bit PCMCIA support, and your network cards do not appear
- to work properly when inserted into the Dock II's PCMCIA slots; or, if you
- have an ISA network card in the Dock II that has a "Code 10" error in its
- properties in Device Manager, call the IBM Help Center. They will provide
- you with a file to correct this problem.
-
-
-
-