  1. Rockwell V.32/V.32bis AT Command Set Reference
  2. Revision Date :  27 Dec 95
  3.  
  4.  
  5. Basic AT Commands
  6.  
  7. A/  Repeat Last Command
  8.  
  9. A   Answer
  10.  
  11. Bn  CCITT or Bell Modulation
  12.   B0  Selects CCITT operation at 300 or 1200 bps
  13.   B1  Selects BELL operation at 300 or 1200 bps (Default)
  14.  
  15. Dn      Dial
  16. Punctuation characters may be used for clarity, with parentheses, hyphen, and spaces being ignored
  17.   0-9   DTMF digits 0 to 9
  18.   *   The "star" digit (tone only)
  19.   #   The "gate" digit (tone only)
  20.   A-D   DTMF digits A, B, C, & D
  21.   L   Re-dial last number
  22.   P   Select pulse dialing
  23.   T   Select tone dialing
  24.   R   Wait 10 seconds after dialing then go into answer mode; must be at end
  25.   S=n   Dial number stored in directory (n = 0 to 19). (See &Z)
  26.   !   Flash
  27.   W   Wait for dial tone
  28.   @   Wait for 5 sec silence
  29.   ,    Dial pause (see S8)
  30.   ;    Return to command state; must be at end
  31.   ^   Enable calling tone
  32.   >   Grounding pulse
  33.  
  34. En      Command Echo
  35.   E0  Disables command echo.
  36.   E1  Enables command echo.  (Default)
  37.  
  38. Fn      Select Line Modulation
  39.   F0   Selects auto-detect mode (Default)
  40.   F1   Selects V.21 or Bell 103 according to the "B" setting
  41.   F3   Selects V.23 as the only acceptable line modulation for a subsequent connection.  Originator is at 75 bps and answerer is at 1200 bps
  42.   F4   Selects V.22 1200 bps or Bell 212A according to "B"
  43.   F5   Selects V.22bis as the only acceptable line modulation
  44.   F6   Select V.32bis 4800 bps or V.32 4800 bps as the only acceptable line modulation
  45.   F7   Selects V.32bis 7200 bps as only acceptable modulation
  46.   F8   Selects V.32bis 9600 bps or V.32 9600 bps as the only acceptable line modulation
  47.   F9  Selects V.32bis 12000 bps as only acceptable modulation
  48.   F10   Selects V.32bis 14400 bps as only acceptable
  49.  
  50. Hn      Disconnect (Hangup)
  51.   H0   Release line if on-line
  52.   H1  If on-hook, go off-hook and enter command mode for period of time determined by S7
  53.  
  54. In      Identification
  55.   I0  Reports product code.
  56.   I1  Reports ROM checksum
  57.   I2  Responds OK
  58.   I3  Reports firmware revision
  59.   I4  Reports modem identifier
  60.     Mfr=U. S. Robotics
  61.     CmdSet=Pilot1
  62.     Mod=V.32bis
  63.     Fax=1, 2
  64.     EC/DC=V.42bis, MNP5
  65.   I5  Reports Country Code
  66.   I6  Reports modem data pump model and internal code revision
  67.  
  68. Ln      Speaker Volume
  69.   L0  No real control
  70.   L1  (the actual default)
  71.   L2  no matter which of
  72.   L3  these is selected
  73.  
  74. Mn      Speaker Control
  75.   M0  Speaker is always off.
  76.   M1  On during call establishment, but off when receiving carrier. (Default)
  77.   M2  Speaker always on.
  78.   M3  Speaker off when receiving carrier and during dialing, but on during answering
  79.  
  80. Nn      Automode Enable
  81.   N0  Detection disabled
  82.   N1  Detection enabled (same as F0)  (Default)
  83.  
  84. On Return to OnLine Data Mode
  85.   O0  Enters without a retrain
  86.   O1  Enters with a retrain
  87.  
  88. P       Set Pulse Dial Default
  89.  
  90. Qn  Quiet Results Codes Control
  91.   Q0  Enables result codes to the DTE.  (Default)
  92.   Q1  Disables result codes
  93.  
  94. Sn   Read/Write S Registers:
  95.   n=v     Sets S Register "n" to the value "v"
  96.   n?   Reports the value of S Register "n"
  97.  
  98. T   Set Tone Dial (Default)
  99.  
  100. Vn      Result Code Form
  101.   V0  Enables terse result codes.  Line feed is not issued
  102.   V1  Verbose result codes.  (Default)
  103.  
  104. Wn   Error Correction Message Control
  105.   W0  Upon connection, the modem reports only the DTE speed (e.g, CONNECT 9600)
  106.   W1  Upon connection, the modem reports the line speed, the error correction protocol, and the DTE speed, respectively
  107.   W2  Upon connection, the modem reports the DCE speed (e.g, CONNECT 2400) (Default)
  108.  
  109. Xn      Extended Result Codes
  110.   X0  Disables BUSY, NO DIALTONE, & CONNECT speed
  111.   X1  Disables BUSY & NO DIALTONE
  112.   X2  Disables BUSY
  113.   X3  Disables NO DIALTONE
  114.   X4  Send all messages (Default)
  115.  
  116. Yn   Long Space Disconnect
  117.   Y0  Disabled  (Default)
  118.   Y1  Enabled 
  119.  
  120. Zn  Soft Reset & Restore Profile
  121.   Z0  Soft reset and restore stored profile 0.
  122.   Z1  Soft reset and restore stored profile 1.
  123.  
  124.  
  125. AT& COMMANDS:
  126.  
  127. &Cn     RLSD (DCD) Option
  128.   &C0   RLSD remains ON at all times
  129.   &C1   RLSD follows the state of the carrier (Default)
  130.  
  131. &Dn     DTR Option
  132.   &D0   DTR drop is interpreted according to the current &Q setting as follows
  133.      &Q0,5,6    DTR is ignored (assumed ON).  Allows operation with DTE's which don't provide DTR.
  134.      &Q1,4    DTR drop causes the modem to hang up.  Auto-answer is not affected.
  135.      &Q2,3    DTR drop causes the modem to hang up.  Auto-answer is inhibited.
  136.   &D1   DTR drop is interpreted according to the current &Q setting as follows:
  137.      &Q0,1,4,5,6   DTR drop is interpreted by the modem as if the asynchronous escape sequence had been entered.  The modem returns to asynchronous command state without disconnecting.
  138.      &Q2,3    DTR drop causes the modem to hang up.  Auto-answer is inhibited.
  139.   &D2   DTR drop is interpreted according to the current &Q setting as follows:  (Default)
  140.      &Q0..6     DTR drop causes the modem to hang up.  Auto-answer is inhibited.
  141.   &D3     DTR drop is interpreted according to the current &Q setting as follows:
  142.      &Q0,1,4,5,6     DTR drop causes the modem to perform a soft reset as if the "Z" command were received. The &Y setting determines which profile is loaded.
  143.      &Q2,3     DTR drop causes the modem to hang up.  Auto-answer is inhibited.
  144.  
  145. &Fn     Restore Factory Configuration (Profile)
  146.   &F0     Restore factory configuration 0
  147.   &F1     Restore factory configuration 1
  148.  
  149. &Gn     Select Guard Tone
  150.   &G0   Disables Guard Tone.  Default.
  151.   &G1   Disables Guard Tone.
  152.   &G2   Selects 1800 Hz guard tone.
  153.  
  154. &Kn     Flow Control
  155.   &K0   Disables flow control.
  156.   &K3   Enables RTS/CTS flow control. (default for data modem modes)
  157.   &K4   Enables XON/XOFF flow control.
  158.   &K5   Enables transparent XON/XOFF flow control.
  159.   &K6   Enables both RTS/CTS and XON/XOFF flow control.
  160.  
  161. &Mn   Asynchronous Mode Selection
  162.   &M0   Selects direct asynch operation (See &Q)
  163.  
  164. &Qn     Sync/Async Mode
  165.   &Q0   Selects direct asynchronous operation (See &M0)
  166.   &Q4   Select AutoSync operation.  AutoSync operation, when used in conjunction with the Hayes Synchronous Interface (HSI) capability in the DTE, provides synchronous communication capability from an asynchronous terminal
  167.      Starting AutoSync.  Set registers S19, S20, and S25 to the desired values before selecting AutoSync operation with &Q4.  After the CONNECT message is issued, the modem waits the period of time specified by S25 before examining DTR.  If DTR is on, the modem enters the synchronous operating state;  if DTR is off, the modem terminates the line connection and returns to the asynchronous command state.
  168.      Stopping AutoSync.  AutoSync operation is stopped upon loss of carrier or the ON-to-OFF transition of DTR.
  169.   &Q5   The modem will try to negotiate an error-corrected link.  Default
  170.   &Q6   Selects asynchronous operation in normal mode (speed buffering).
  171.  
  172. &Rn     RTS/CTS Option
  173.   &R0     In sync mode, CTS tracks the state of RTS; the RTS-to-CTS delay is defined by S26.  In Async mode, CTS acts according to V.25bis handshake.
  174.   &R1   In sync mode, CTS is always ON (RTS transitions are ignored).  In Async, CTS will drop only if required by flow control.  Default.
  175.  
  176. &Sn     DSR Override
  177.   &S0   DSR will remain ON at all times.  Default
  178.   &S1   DSR will become active after answer tone has been detected and inactive after the carrier has been lost.
  179.  
  180. &Tn     Test and Diagnostics
  181.  
  182. &V      Display Current Configuration and Stored Profiles
  183.  
  184. &Wn     Store Current Configuration
  185.   &W0   Store the current configuration as profile 0.
  186.   &W1   Store the current configuration as profile 1.
  187.  
  188. &Yn     Designate a Default Reset Profile
  189.   &Y0   The modem will use profile 0.
  190.   &Y1   The modem will use profile 1.
  191.  
  192. &Zn=x   Store Telephone Number
  193.   &Zn=x   (n = 0 to 3, and x = dial string) (requires 256-byte NVRAM)
  194.  
  195.  
  196. AT% COMMANDS:
  197.  
  198. %C - Enable/Disable Data Compression:
  199.   %C0   Disables compression.
  200.   %C1   Enables MNP 5 data compression negotiation.
  201.   %C2   Enables V.42bis data compression
  202.   %C3   Enables both V.42bis and MNP 5 data compression. Default
  203.  
  204. %En     Enable/Disable Line Quality Monitor & Auto-Retrain Fallback/Fall Forward:
  205.   %E0   Disable line quality monitor and auto-retrain.  Default.
  206.   %E1   Enable line quality monitor and auto-retrain.
  207.   %E2   Enable line quality monitor and fallback/fall forward.
  208.   %E3   Enable line quality monitor and auto-retrain, but hang-up immediately when EQM reaches hang-up threshold.  AKA Fast Hangup.
  209.  
  210. %L-Line Signal Level:
  211.  
  212. %Q - Line Signal Quality:
  213.  
  214. %TTn - PTT Testing Utilities:
  215.  
  216.  
  217. AT\ COMMANDS:
  218.  
  219. \An - Select Maximum MNP Block Size:
  220.   \A0  64 characters
  221.   \A1  128 characters  Default
  222.   \A2  192 characters
  223.   \A3  256 characters
  224.  
  225. \Bn - Transmit Break to Remote:
  226.   \B1-\B9   Break length in 100 mS units. (default = 3) (Non-error corrected mode only) 
  227.  
  228. \Ln - MNP Block/Stream Mode Select:
  229.   \L0   Use stream mode for MNP connection.  Default
  230.   \L1   Use interactive block mode for MNP connection.  This command will accept block mode but implement stream mode.
  231.  
  232. \Gn - Modem-to-Modem Flow Control (XON/XOFF):
  233.   \G0   Disables modem-to-modem XON/XOFF flow control.  Default
  234.   \G1   Enables modem-to-modem XON/XOFF flow control.
  235.  
  236. \Kn - Break Control:
  237.  
  238. \Nn - Operating Mode:
  239.   \N0   Selects normal speed buffered mode (disables error-correction mode) (Forces &Q6)
  240.   \N1   Serial interface selected - selects direct mode and is equivalent to &M0, &Q0 mode of operation. (forces &Q0)  Parallel interface selected - Same as \N0.
  241.   \N2   Selects reliable (error-correction) mode.  The modem will first attempt an LAPM connection and then an MNP connection.  Failure to make a reliable connection results in the modem hanging up.
  242.   \N3   Selects auto reliable mode.  This operates the same as \N2 except failure results in the modem falling back to the speed buffered normal mode. Default
  243.   \N4   Selects LAPM error-correction mode.  Failure to make a LAPM error-correction connection results in hanging up.
  244.   \N5   Selects MNP error-correction mode.  Failure to make an MNP error-correction connection results in hanging up.
  245.  
  246. \S - Report Active Configuration (Not supported on all modems)
  247.  
  248.  
  249. S REGISTER SUMMARY:
  250.  
  251.  
  252. Register           Function                   Range        Units      Default
  253. -------- -----------------------------------  ------   ------------   -------
  254. S0       Rings to Auto-Answer                 0-255        Rings      0
  255. S1       Ring Counter                         0-255        Rings      0
  256. S2       Escape Character                     0-255        ASCII      43
  257. S3       Carriage Return Character            0-127        ASCII      13
  258. S4       Line Feed Character                  0-127        ASCII      10
  259. S5       Backspace Character                  0-255        ASCII      8
  260. S6       Wait Time for Dial Tone              2-255        seconds    2
  261. S7       Wait for Carrier                     1-255        seconds    50
  262. S8       Pause Time for (,) Comma             0-255        seconds    2
  263. S9       Carrier Detect Response Time         1-255        1/10 sec   6
  264. S10      Carrier Loss Disconnect Time         1-255        1/10 sec   14
  265. S11      Touch Tone (DTMF) Duration           50-255       1/1000 sec 95
  266. S12      Escape Code Guard Time               0-255        2/100sec   50
  267. S14      General Bit Mapped Options                                   138 (8ah)
  268. S16      Test Mode Bit Mapped Options (&T)                            0
  269. S18      Test Timer                           0-255        seconds    0
  270. S21      V.24/General Bit Mapped Options--                            52
  271. S22      Speaker/Results Bit Mapped Options--                         117 (75h)
  272. S23      General Bit Mapped Options--                                 54
  273. S24      Sleep Inactivity Timer               0-255        seconds    0
  274. S25      Delay to DTR off                     0-255        1/100 sec  5
  275. S26      RTS-to-CTS Delay                     0-255        1/100 sec  1
  276. S27      General Bit Mapped Options--                                 73 (49h)
  277. S28      General Bit Mapped Options--                                 0
  278. S29      Flash Dial Modifier Time             0-255        10 ms      70
  279. S30      Disconnect Activity Timer            0-255        10 sec     0
  280. S31      General Bit Mapped Options--                                 202
  281. S32      XON Character                        0-255        ASCII      17 (11h)
  282. S33      XOFF Character                       0-255        ASCII      19 (13h)
  283. S36      LAPM Failure Control--                                       7
  284. S37      Line Connection Speed--                                      0
  285. S38      Delay Before Forced Hangup           0-255        seconds    20
  286. S39      Flow Control--                                               3
  287. S40      General Bit Mapped Options--                                 104
  288. S41      General Bit Mapped Options--                                 195
  289. S46      Data Compression Control--                                   138
  290. S48      V.42 Negotiation Control--                                   7
  291. S82      LAPM Break Control--                                         128 (40h)
  292. S86      Call Failure Reason Code            0-255
  293.   S86=0   Normal disconnect, no error occurred.
  294.   S86=4   Loss of carrier.
  295.   S86=5   V.42 negotiation failed to detect an error-correction modem at the other end.
  296.   S86=6   No response to feature negotiation.
  297.   S86=7   This modem is asynchronous only; the other modem is synchronous only.
  298.   S86=8   No framing technique in common.
  299.   S86=9   The modems could not find a common protocol.
  300.   S86=10  Bad response to feature negotiation.
  301.   S86=11  No sync information from remote modem.
  302.   S86=12  Normal disconnect initiated by the remote modem.
  303.   S86=13  Remote modem does not respond after 10 re-transmissions of the same message.
  304.   S86=14  Protocol violation.
  305. S91      PSTN Transmit Attenuation Level     l0-15         dBm        9
  306. S92      Fax Transmit Attenuation Level      l0-15         dBm        10
  307. S95      Result Code Messages Control--                               0
  308. S201     Cellular Transmit Level             l0-63                    50
  309. S202     Remote Access Escape Character      0-255         ASCII      0
  310.  
  311.  