  1.  
  2.       ProtoCAD 3D  Ver 2.00    Copyright 1994, TRIUS, Inc.
  3.            P.O. BOX 249,  North Andover,  MA  01845
  4.     ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  5.                       In the UK contact
  6.  
  7.     The Software Source, Atlantic Coast plc, The Shareware Village,
  8.               Station Road, Colyton, Devon EX13 6HA
  9.                     Sales   0297 552 222
  10.                     Support 0297 552 020
  11.                     Fax     0297 553 366
  12.                     BBS     0297 553 800
  13.  
  14.  
  15.  This READ.ME file contains information about  ProtoCAD 3D that did 
  16.  not make it to the printed manual of Ver. 2.00. It also lists the 
  17.  files distributed with Ver 2.00, and explains how to upgrade from 
  18.  previous versions. 
  19.  
  20.  Please READ THIS FILE THOROUGHLY!  It contains very important 
  21.  information, and reading it now will probably save you time and 
  22.  trouble later on! 
  23.  
  24.  You can print this file by COPYing it to your printer with the 
  25.  following command: 
  26.  
  27.        copy READ.ME prn
  28.  
  29.  If you want to look at the other On-Disk ProtoCAD 3D documentation, 
  30.  see the file list below, which lists all of the documentation files, 
  31.  and see the section on the On-Disk User's Manual. 
  32.  
  33.  Shareware and the Association of Shareware Professionals
  34.  ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  35.                 _______
  36.            ____|__     |               (tm)
  37.         --|       |    |-------------------
  38.           |   ____|__  |  Association of
  39.           |  |       |_|  Shareware
  40.           |__|   o   |    Professionals
  41.         -----|   |   |---------------------
  42.              |___|___|    MEMBER
  43.  
  44.  The shareware concept has made it possible for you to obtain extremely 
  45.  powerful software at a price you can afford, and it gives you the 
  46.  opportunity to try the software before you register. 
  47.   
  48.  Shareware is kept alive by YOUR support.
  49.  
  50.  Evaluate the program for 30-days and give copies to your friends for 
  51.  evaluation.  If, after the 30 days, you continue to use the program, 
  52.  then register it by sending us the registration/order form included in 
  53.  this help file or by calling 0297 552222 (Orders Only!). You will
  54.  receive the Latest version, Printed manual, 90-day free Technical 
  55.  Phone Support, BBS Technical Support, Newsletter, and Reduced price 
  56.  Upgrades.  
  57.      
  58.  In addition to that, the 'UNREGISTERED COPY' message will be 
  59.  eliminated from the screen and a tool bar with the most frequently 
  60.  used commands will take its place.  Registering will also get you the 
  61.  capability of using external script files to create series of TGA and 
  62.  PCX files for animation sequences. And, of course, it will get you the 
  63.  legal license to use the software beyond the 30-day evaluation period. 
  64.  
  65.   ╔═════════════════════════════════════════════════════════════╗  
  66.   ║ If you purchased a Disk, without a printed, bound, user's   ║ 
  67.   ║ manual, or you downloaded a copy from a BBS or other        ║ 
  68.   ║ service, or you got a copy of ProtoCAD 3D from a CD-ROM, or ║ 
  69.   ║ the program was pre-loaded on your computer, then you have  ║ 
  70.   ║ a 30-day evaluation shareware copy.  You need to purchase   ║ 
  71.   ║ a registered copy after the 30-day evaluation!              ║ 
  72.   ╚═════════════════════════════════════════════════════════════╝
  73.  
  74.  Support new developments in ProtoCAD 3D, register your copy today! 
  75.  
  76.  Thank you for your support!
  77.    
  78.  ProtoCAD 3D is produced by a member of the Association of Shareware 
  79.  Professionals (ASP).  ASP wants to make sure that the shareware 
  80.  principle works for you.  If you are unable to resolve a shareware-
  81.  related problem with an ASP member by contacting the member directly, 
  82.  ASP may be able to help.  The ASP Ombudsman can help you resolve a 
  83.  dispute or problem with an ASP member, but does not provide technical 
  84.  support for member's products.  Please write to the ASP Ombudsman at: 
  85.  
  86.        ASP Ombudsman
  87.        545 Grover Road 
  88.        Muskegon, MI  49442-9427
  89.  
  90.  or send a Compuserve message via CMail to ASP Ombudsman 70007,3536. 
  91.  
  92.  
  93.  Minimum Hardware Requirements
  94.  ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  95.   -  386SX CPU (see note below)
  96.   -  EGA or better video capabilities (VGA, SVGA, VESA)
  97.   -  480k minimum free memory (RAM)
  98.   -  2 Mb EMS (see note below)
  99.   -  DOS 3.2 or later
  100.   -  3.5" Drive(s), or 5.25" HD Drive(s), or Diskette/Hard Disk combination
  101.     
  102. Note:  Though the program will run on an XT or a 286 based CPU, with 
  103.        only 640k RAM, a 386SX CPU or better and 2Mb EMS is strongly 
  104.        recommended for any serious work.
  105.  
  106.  
  107.  GETTING STARTED
  108.  ~~~~~~~~~~~~~~~
  109.  The information provided below is to help you start the program for 
  110.  your hardware configuration.  For more details about the operation of 
  111.  the program press the F1 (function) key once you have started the 
  112.  program. 
  113.  
  114.  Once installed (see below for installation procedure) ProtoCAD 3D is 
  115.  started from DOS using the command: 
  116.  
  117.   C:> PC3D /Option1/Option2/Option3/.....     [ENTER]
  118.  
  119.  where Option1, Option2, etc.  are options specifying the type of 
  120.  memory to use, the type of graphics video adaptor, etc.  For a 
  121.  complete description of these options, please print and consult the 
  122.  on-disk user's manual.
  123.  
  124.  
  125.  Ordering Information
  126.  ~~~~~~~~~~~~~~~~~~~~
  127.  Remember that a shareware copy is an EVALUATION copy that you can use 
  128.  for up to 30 days.  If you continue to use the program, Registration 
  129.  and payment are Required!  You may register using the order form in the 
  130.  ORDER.ME file, or by calling The Software Source and charging your
  131.  purchase on your credit card. We suggest that you call, since prices
  132.  are subject to change without notice.
  133.  
  134.  You may also order your copy on-line by calling our TRIUS Support BBS 
  135.  at (508) 794-0762 [12/24/9600,N,8,1  - 24 hrs]. 
  136.  
  137.  If you live outside the US and Canada you may want to contact TRIUS, 
  138.  Inc. for a dealer in your country.  Purchasing through these dealers 
  139.  can save you the delay and inconvenience which may be involved in 
  140.  dealing with currency conversions and international shipping and in 
  141.  many cases will provide you with faster technical support. 
  142.  
  143.  
  144.  Files on the ProtoCAD 3D Distribution Disk(s)
  145.  ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  146.   PC3D20.FLS   -  Compressed Archive
  147.   READ.ME      -  Start-Up instructions (This file)     
  148.   ORDER.ME     -  Ready-to-print order form  
  149.   LICENSE.DOC  -  Please Read This!!         
  150.   VENDOR.DOC   -  Info on Distributing Shareware Copies
  151.   INSTALL.EXE  -  Automated SetUp File       
  152.  
  153.  
  154.  Installation on Floppy or Hard Disk:  
  155.  ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  156.  The program will work if installed on 3.5" (720K or 1.44Mb) diskettes, 
  157.  or 5.25" HD (1.2 Mb) diskettes.  We recommend that the program is 
  158.  installed either on a hard disk, or a high density floppy diskette, 
  159.  since this will permit the help file, and other auxiliary files, to be 
  160.  available to the user.  
  161.  
  162.      If you Install and run ProtoCAD 3D from a floppy disk, without      
  163.      Expanded memory (EMS), or if the /NE command line switch is        
  164.      used, and you remove the ProtoCAD 3D program disk from  
  165.      the drive while the program is running, you will get an 
  166.      error message and will be instructed to re-insert the disk.
  167.    
  168.  * Place the ProtoCAD 3D original diskette in drive A: (or B:)
  169.  
  170.  * Make sure the current logged drive is A: (Type A:, or B:, and 
  171.    press ENTER, if it is not).
  172.   
  173.  * Type INSTALL and press [ENTER].  Then, follow the simple on-screen 
  174.    instructions to install your copy of the program on the desired disk(s) 
  175.    and/or subdirectory.
  176.  
  177.  
  178. Upgrading from Ver 1.1 or earlier
  179. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  180. If you are upgrading from an earlier version of the program, we 
  181. recommend that you install the program in the directory where the old 
  182. version resides, answering Yes when the installation program asks if 
  183. you want to overwrite the files.  Furthermore, it is recomended that 
  184. you delete the old configuration file (PC3D.CFG), in that directory 
  185. prior to running ProtoCAD 3D v2.00. 
  186.  
  187.  
  188. Windows Users
  189. ~~~~~~~~~~~~~
  190. ProtoCAD will work fine under Windows 3.1.  If you are going to run the 
  191. program in a windows environment, you may use the files PC3D.PIF and 
  192. PC3D.ICO which are extracted as part of the installation process.  It 
  193. should be noted that the PC3D.PIF file is setup to run the program in a 
  194. windowed mode.  For better program response, however, we recommend that 
  195. the PIF file is modified (using the Windows PIF Editor), to run in full 
  196. screen mode. 
  197.  
  198.  
  199.  On-Disk Documentation
  200.  ~~~~~~~~~~~~~~~~~~~~~
  201.  The installation process extracts a file called PC3D.MAN.  This is a 
  202.  ready-to-print formatted, User's manual for the program.  
  203.  
  204.  Following the installation, make sure that the PC3D.MAN file is 
  205.  indeed on your default directory.  Then, to print this manual: 
  206.  
  207.  (1)  Make sure that the your printer is ON  and there is enough 
  208.       paper in it (the manual is about 100 pages).
  209.  
  210.  (2)  From the DOS prompt, type
  211.  
  212.       COPY PC3D.MAN PRN and press [ENTER]
  213.  
  214.       Note that if your printer is connected to a SERIAL port,
  215.       then you need to use the command  COPY PC3D.MAN COM1, or
  216.       COPY PC3D.MAN COM2 (depending on which serial port your 
  217.       printer is connected to).
  218.   
  219.  
  220.  
  221. NOTES/ADDITIONS TO THE USER'S MANUAL
  222. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  223.  1. When a new view is selected, an image extents scan is made and the 
  224.     image is placed in the center of the screen (similar to performing 
  225.     an Image, All command), if the Auto Ctr toggle is ON.
  226.     
  227.  2. Identifying reference marks are placed in the center of facets.  This 
  228.     is particularly useful when trying to change the surface normal, since 
  229.     it permits you to select uniquely identified facets. 
  230.  
  231.  3. The limit on the number of points that can be accommodated when 
  232.     importing a WAV file, was increased to 8000.
  233.  
  234.  4. VGA 256-color and VESA color mapping is done using a 3,3,2 model, 
  235.     i.e., 3 bits are used for Green, 3 for Red and 2 for Blue.  Since 
  236.     there is not enough resolution (2 bits) for Blue, you might 
  237.     experience blue patches when rendering an 'almost' gray scale image.  
  238.     If that happens, select the Gray option in the Render sub-menu. 
  239.  
  240.  5. When rendering in 256 colors, the edges are NOT visible regardless of 
  241.     the setting selected in the Render, Edges sub-menu.
  242.  
  243.  6. The trackball employs an effective 'gimbal lock' mechanism.  If the 
  244.     image is rotated/rolled beyond a 90 degree angle, the  Yaw  angle 
  245.     automatically switches by 180 degrees. 
  246.  
  247.  7. As the observer distance (D) is reduced, and you move closer to the 
  248.     center of the image, you will observe some clipping of polygons that 
  249.     are effectively behind the focal length plane.  This normally occurs at 
  250.     about D=0.5.  You might need to render the image to re-orient 
  251.     yourself. 
  252.  
  253.  8. When attempting to print without EMS, the 32k-48k shadow buffer is 
  254.     used by the Z-buffer model to internally render the image in 
  255.     horizontal strips.  Since the buffer size is limited, the longer the 
  256.     strip (specified print width) the narrower the vertical strip size 
  257.     that can be accommodated.  When the calculated vertical size falls 
  258.     below 16 scan lines, the program will not render and will abort the 
  259.     printing process.  This limit will accommodate a 7.5 inch width at 
  260.     120 dots per inch resolution.  Under these conditions, if you want to 
  261.     increase the resolution, you'd have to reduce the specified print 
  262.     width.  For above example, if you wanted to use 240 dpi resolution, 
  263.     the specified width should be approximately 3.75 inches. 
  264.  
  265.  9. When creating TGA output files, the program requires approximately 
  266.     300k of EMS to render the image.  If it's not available, the TGA 
  267.     output menu is disabled and an appropriate error message will be 
  268.     issued. 
  269.          
  270. - End -