- ; M7VG-2.ASM -- V.G. Bitstreamer II & U.S. Robotics S-100 overlay for MDM7xx. 07/17/84
- ;
- ; This overlay adapts the MDM7xx program to the U.S. Robotics S-100
- ; autodial modem. It works equally as well with MEX..
- ;
- ; You will want to look this file over carefully. There are a number of
- ; options that you can use to configure the program to suit your taste.
- ;
- ; This overlay is capable of setting the baud rate and sending breaks.
- ; Although disconnecting the modem is not supported (by use of a function
- ; to lower DTR), the control-N command still works, as it uses "+++"
- ; which causes the U.S.R. S-100 modem to hang up. If you are running a
- ; system which has a clock speed of more than 4 MHz, be sure to see
- ; the routine INITMOD, as you will have to "uncomment" some do-nothing
- ; time wasting statements to slow your computer down for the modem.
- ;
- ;
- ; TO USE: First edit this file filling in answers for your own
- ; equipment. Then assemble with ASM.COM or equivalent
- ; assembler. Then use DDT to overlay the the results
- ; of this program to the original .COM file:
- ;
- ; A>DDT MDM7xx.COM
- ; DDT VERS 2.2
- ; NEXT PC
- ; 4A00 0100
- ; -IM7US-1.HEX (note the "I" command)
- ; -R ("R" loads in the .HEX file)
- ; NEXT PC
- ; 4A00 0000
- ; -G0 (return to CP/M)
- ; A>SAVE 73 MDM7xx.COM (now have a modified .COM file)
- ;
- ; = = = = = = = = = = = = = = = = = =
- ;
- ; 07/17/84 - Added Vector Graphics Bitstreamer
- ; 'STUFF'. NOTE: I use this overlay
- ; with MEX. - Rod Hart WA3MEZ
- ; 03/17/84 - Updated to match MDM728 - Bob plouffe
- ; 12/21/83 - Added "commented" delays in init-
- ; ialization for fast systems. - Phil Lapsley
- ; 12/19/83 - Now sends AT command in the
- ; initialization routine to get
- ; the attention of the USR S-100 - Phil Lapsley
- ; 12/17/83 - Created from M7GP-1.ASM - Phil Lapsley
- ; 11/11/83 - Renamed to M7GP-1.ASM, no changes - Irv Hoff
- ; 07/27/83 - Renamed to work with MDM712 - Irv Hoff
- ; 07/01/83 - Revised to work with MDM711 - Irv Hoff
- ; 07/01/83 - Revised to work with MDM710 - Irv Hoff
- ; 05/27/83 - Updated to work with MDM709 - Irv Hoff
- ; 05/15/83 - Revised to work with MDM708 - Irv Hoff
- ; 04/11/83 - Updated to work with MDM707 - Irv Hoff
- ; 04/04/83 - First version of this file - Irv Hoff
- ;
- ; = = = = = = = = = = = = = = = = =
- ;
- TRUE: EQU 01H
- FALSE: EQU 00H
- ;
- BELL: EQU 07H ;bell
- CR: EQU 0DH ;carriage return
- ESC: EQU 1BH ;escape
- LF: EQU 0AH ;linefeed
- ;
- YES: EQU 0FFH
- NO: EQU 0
- ;
- ;
- ; Change the following information to match your equipment
- ;
- PSEL1: EQU FALSE ;TRUE FOR PORT 1.
- PSEL2: EQU FALSE ;TRUE FOR PORT 2.
- PSEL3: EQU TRUE ;TRUE FOR PORT 3.
- ;
- BASE: EQU 042H ;BITSTREAMER BASE ADDR.
- ;
- IF PSEL1
- PORT: EQU BASE ;1ST PORT SELECTED.
- ENDIF
- ;
- IF PSEL2
- PORT: EQU BASE+2 ;2ND PORT SELECTED.
- ENDIF
- ;
- IF PSEL3
- PORT: EQU BASE+4 ;3RD PORT SELECTED.
- ENDIF
- ;
- MODCTL1: EQU PORT+1 ;MODEM CONTROL PORT
- MODDATP: EQU PORT ;MODEM DATA IN PORT
- MODDATO: EQU PORT ;MODEM DATA OUT PORT
- MODDCDB: EQU 080H ;CARRIER DETECT BIT
- MODDCDA: EQU 080H ;VALUE WHEN ACTIVE
- MODRCVB: EQU 2 ;BIT TO TEST FOR RECEIVE
- MODRCVR: EQU 2 ;VALUE WHEN READY
- MODSNDB: EQU 1 ;BIT TO TEST FOR SEND
- MODSNDR: EQU 1 ;VALUE WHEN READY
- ;
- ORG 100H
- ;
- ;
- ; Change the clock speed to suit your system
- ;
- DS 3 ;(for "JMP START" instruction)
- ;
- PMMIMODEM: DB NO ;yes=PMMI S-100 Modem 103H
- SMARTMODEM: DB YES ;yes=HAYES Smartmodem, no=non-PMMI 104H
- TOUCHPULSE: DB 'T' ;T=touch, P=pulse (Smartmodem-only) 105H
- CLOCK: DB 55 ;clock speed in MHz x10, 25.5 MHz max. 106H
- ;20=2 MHh, 37=3.68 MHz, 40=4 MHz, etc.
- MSPEED: DB 5 ;0=110 1=300 2=450 3=600 4=710 5=1200 107H
- ;6=2400 7=4800 8=9600 9=19200 default
- BYTDLY: DB 5 ;0=0 delay 1=10ms 5=50 ms - 9=90 ms 108H
- ;default time to send character in ter-
- ;minal mode file transfer for slow BBS.
- CRDLY: DB 5 ;0=0 delay 1=100 ms 5=500 ms - 9=900 ms 109H
- ;default time for extra wait after CRLF
- ;in terminal mode file transfer
- NOOFCOL: DB 5 ;number of DIR columns shown 10AH
- SETUPTST: DB YES ;yes=user-added Setup routine 10BH
- SCRNTEST: DB YES ;Cursor control routine 10CH
- NORETRY DB NO ;yes=DON'T ALLOW RETRY/QUIT OPTION 10DH
- ;no=ALLOW RETRY/QUIT AFTER 10 TIMEOUTS
- BAKUPBYTE: DB NO ;yes=change any file same name to .BAK 10EH
- CRCDFLT: DB YES ;yes=default to CRC checking 10FH
- TOGGLECRC: DB YES ;yes=allow toggling of CRC to Checksum 110H
- CONVBKSP: DB YES ;yes=convert backspace to rub 111H
- TOGGLEBK: DB YES ;yes=allow toggling of bksp to rub 112H
- ADDLF: DB NO ;no=no LF after CR to send file in 113H
- ;terminal mode (added by remote echo)
- TOGGLELF: DB YES ;yes=allow toggling of LF after CR 114H
- TRANLOGON: DB YES ;yes=allow transmission of logon 115H
- ;write logon sequence at location LOGON
- SAVCCP: DB YES ;yes=do not overwrite CCP 116H
- LOCONEXTCHR: DB NO ;yes=local command if EXTCHR precedes 117H
- ;no=external command if EXTCHR precedes
- TOGGLELOC: DB YES ;yes=allow toggling of LOCONEXTCHR 118H
- LSTTST: DB YES ;yes=printer available on printer port 119H
- XOFFTST: DB NO ;yes=checks for XOFF from remote while 11AH
- ;sending a file in terminal mode
- XONWAIT: DB NO ;yes=wait for XON after CR while 11BH
- ;sending a file in terminal mode
- TOGXOFF: DB YES ;yes=allow toggling of XOFF checking 11CH
- IGNORCTL: DB YES ;yes=CTL-chars above ^M not displayed 11DH
- EXTRA1: DB 0 ;for future expansion 11EH
- EXTRA2: DB 0 ;for future expansion 11FH
- BRKCHR: DB '@'-40H ;^@ = Send 300 ms. break tone 120H
- NOCONNCT: DB 'N'-40H ;^N = Disconnect from the phone line 121H
- LOGCHR: DB 'L'-40H ;^L = Send logon 122H
- LSTCHR: DB 'P'-40H ;^P = Toggle printer 123H
- UNSAVE: DB 'R'-40H ;^R = Close input text buffer 124H
- TRANCHR: DB 'T'-40H ;^T = Transmit file to remote 125H
- SAVECHR: DB 'Y'-40H ;^Y = Open input text buffer 126H
- EXTCHR: DB '^'-40H ;^^ = Send next character 127H
- ;
- ;
- DS 2 ; 128H
- ;
- IN$MODCTL1: IN MODCTL1 ! RET ;in modem control port 12AH
- DS 7
- OUT$MODDATP: OUT MODDATP ! RET ;out modem data port 134H
- DS 7
- IN$MODDATP: IN MODDATP ! RET ;in modem data port 13EH
- DS 7
- ANI$MODRCVB: ANI MODRCVB ! RET ;bit to test for receive ready 148H
-
- CPI$MODRCVR: CPI MODRCVR ! RET ;value of rcv. bit when ready 14BH
- ANI$MODSNDB: ANI MODSNDB ! RET ;bit to test for send ready 14EH
- CPI$MODSNDR: CPI MODSNDR ! RET ;value of send bit when ready 151H
- DS 6 ; 156H
- ;
- OUT$MODCTL1: OUT MODCTL1 ! RET ;out modem control port #1 15AH
- OUT$MODCTL2: RET ! NOP ! NOP ;ctl-port #2 is not used 15DH
- ;
- LOGONPTR: DW LOGON ;for user message. 160H
- DS 6 ; 162H
- JMP$GOODBYE: JMP GOODBYE ; 168H
- JMP$INITMOD: JMP INITMOD ;go to user written routine 16BH
- RET ! NOP ! NOP ;(by-passes PMMI routine) 16EH
- RET ! NOP ! NOP ;(by-passes PMMI routine) 171H
- RET ! NOP ! NOP ;(by-passes PMMI routine) 174H
- JMP$SETUPR: JMP SETUPR ; 177H
- JMP$SPCLMENU: JMP SPCLMENU ; 17AH
- JMP$SYSVER: JMP SYSVER ; 17DH
- JMP$BREAK: JMP SENDBRK ; 180H
- ;
- ;
- ; Do not change the following six lines.
- ;
- JMP$ILPRT: DS 3 ; 183H
- JMP$INBUF DS 3 ; 186H
- JMP$INLNCOMP: DS 3 ; 189H
- JMP$INMODEM DS 3 ; 18CH
- JMP$NXTSCRN: DS 3 ; 18FH
- JMP$TIMER DS 3 ; 192H
- ;
- ;
- ; Routine to clear to end of screen. If using CLREOS and CLRSCRN, set
- ; SCRNTEST to YES at 010AH (above).
- ;
- CLREOS: CALL JMP$ILPRT ; 195H
- DB 1BH,6BH,0,0,0 ; 198H
- RET ; 19DH
- ;
- CLRSCRN: CALL JMP$ILPRT ; 19EH
- DB 0CH,0,0,0,0 ; 1A1H
- RET ; 1A6H
-
- ;
- SYSVER: CALL JMP$ILPRT ; 1A7H
- DB 'Version for U.S.R. Password modem',CR,LF
- DB ' and',CR,LF
- DB ' Vector Graphics Bitstreamer II',CR,LF
- IF PSEL1
- DB ' (PORT 1)',CR,LF,LF
- ENDIF
- ;
- IF PSEL2
- DB ' (PORT 2)',CR,LF,LF
- ENDIF
- ;
- IF PSEL3
- DB ' (PORT 3)',CR,LF,LF
- ENDIF
- DB 0
- RET
- ;.....
- ;
- ;
- ;-----------------------------------------------------------------------
- ;
- ; NOTE: You can change the SYSVER message to be longer or shorter. The
- ; end of your last routine should terminate by 0400H (601 bytes
- ; available after start of SYSVER) if using the Hayes Smartmodem
- ; or by address 0C00H (2659 bytes) otherwise.
- ;
- ;-----------------------------------------------------------------------
- ;
- ; You can put in a message at this location which can be called up with
- ; CTL-O if TRANLOGON has been set TRUE. You can use several lines if
- ; desired. End with a 0.
- ;
- LOGON: DB 'How are you today?',CR,LF,0
- ;.....
- ;
- ;
- ; The following routine sends a break "character" to the remote
- ; computer for 300 ms. The "MSPEED" value is needed to decide whether
- ; or not the modem is at 300 or 1200 baud. The routine must
- ; know this because U.S.R. set up the RTS bit of the command resgister
- ; as a baud rate selection bit, and this routine must be careful not
- ; to change it, or the user will end up at a different baud rate
- ; after the break "character" is sent. Note that the "MVI A, 01FH" does
- ; not change any flags.
- ;
- SENDBRK: MVI A, 03FH ; Otherwise, set up for 300/1200
- SBRK2: OUT MODCTL1 ; Send break
- PUSH PSW ; Save value
- MVI B, 3 ; 300 ms delay value
- CALL JMP$TIMER ; Wait that long
- POP PSW ; Restore command byte
- ANI 0F7H ; Turn off break bit
- OUT MODCTL1 ; Send command byte to UART
- RET
- ;.....
- ;
- ;
- ; The U.S.R. S-100 does not have a "quick-disconnect" feature like
- ; the Hayes does (by lowering DTR). Therefore, "GOODBYE" is not
- ; implemented. Yet control-N still works to hang up (see note
- ; above in introduction)
- ;
- GOODBYE: RET
- ;.....
- ;
- ;
- ; You can use this area for any special initialization or setup you may
- ; wish to include. Each must stop with a RET. This initialization
- ; sets up 300 baud, 8 data bits, 1 stop bit, no parity. Due to a
- ; quirk in the U.S.R. S-100 (it seems to have plenty of 'em), after
- ; you change baud rates, you should send an "AT" followed by a
- ; carriage return. Therefore, this is done after every initialization
- ; when there is no carrier present.
- ;
- ; NOTE: The U.S.R. S-100 does not operate too well at clock speeds of
- ; over 4 MHz. If you are running at that speed or higher, you
- ; should uncomment (by removing the preceding semicolon) the
- ; lines with XCHG. These serve as time wasting routines to
- ; let the U.S.R. S-100 catch up. This is not a problem when
- ; doing character I/O, as the program checks to see if the
- ; modem is ready to accept a character.
- ;
- INITMOD: XRA A ; Zero accumulator
- OUT MODCTL1 ; Clear 8251A
- XCHG ; For fast systems
- XCHG ; For fast systems
- OUT MODCTL1 ; Twice
- XCHG ; For fast systems
- XCHG ; For fast systems
- OUT MODCTL1 ; Three times, even
- XCHG ; For fast systems
- XCHG ; For fast systems
- MVI A, 040H ; Reset UART command
- OUT MODCTL1
- XCHG ; For fast systems
- XCHG ; For fast systems
- MODEBT: MVI A, 04EH ; 8 bits, 1 stop, no parity
- OUT MODCTL1
- XCHG ; For fast systems
- XCHG ; For fast systems
- CMDBT: MVI A, 037H ; On hook, Tx/Rx enable, reset errs
- OUT MODCTL1
- XCHG ; For fast systems
- XCHG ; For fast systems
- BDCODE: MVI A, 5 ; 1200 baud code
- STA MSPEED
- IN MODCTL1 ; Get the current status
- ANI MODDCDB ; See if there is a carrier
- RNZ ; If so, don't do AT stuff
- MVI B, 1 ; 100 ms
- CALL JMP$TIMER ; Wait that long for things to settle
- MVI B, 'A' ; "A" of AT command
- CALL OUTMOD ; Output to the modem
- MVI B, 'T' ; "T" of AT command
- CALL OUTMOD ; Output
- MVI B, CR ; Followed by a carriage return
- CALL OUTMOD ; Output that too
- RET
- ;
- ; Output a character to the U.S.R. S-100
- ; (NOTE: This routine is not normally present in most overlays,
- ; and is used by the INITMOD routine above.)
- ;
- OUTMOD IN MODCTL1 ; Get status
- ANI MODSNDB ; Mask for ready status
- JZ OUTMOD ; Loop if not ready
- MOV A, B ; Otherwise get the character
- OUT MODDATP ; Output to the data port
- RET ; And return
-
- ;
- ; This routine prompts the user for a new baud rate
- ; (on the U.S.R. this can be 300 or 1200, as mdm7xx
- ; has no provision for 150 baud) and sets the modem to that
- ; baud rate.
- ;
- SETUPR: LXI D, BAUDBUF ; Point to new input buffer
- CALL JMP$ILPRT ; Print following line:
- DB 'Input baud rate (300, 1200): ', 0
- CALL JMP$INBUF ; Get a line into the buffer
- LXI D, BAUDBUF + 2 ; compare BAUDBUF+2 with characters
- CALL JMP$INLNCOMP
- DB '300', 0
- JNC OK300
- CALL JMP$INLNCOMP
- DB '1200', 0
- JNC OK1200
- CALL JMP$ILPRT
- DB '++ Incorrect entry ++', CR, LF, BELL, 0
- JMP SETUPR ; Try again
- ;
- OK300: LXI B, BD300 ; Point to intializers for 300 baud
- MVI A, 1 ; 300 baud value
- JMP LOADBD ; Go load it
- ;
- ;
- OK1200: LXI B, BD1200
- MVI A, 5
- ;
- LOADBD: STA BDCODE + 1 ; Change baud rate code value
- LDAX B ; Get mode byte value
- STA MODEBT + 1 ; Change mode byte
- INX B ; Point to cmd byte
- LDAX B ; Get cmd byte
- STA CMDBT + 1 ; Change cmd byte
- JMP INITMOD ; (Re)initialize modem
- ;
- ; Baudrate parameters (mode byte, command byte)
- ; All values give 8 data bits, 1 stop bit, no parity.
- ;
- BD300: DB 04FH, 037H ; 300 baud
- BD1200: DB 04EH, 037H ; 1200 baud
- ;
- BAUDBUF: DB 10, 0
- DS 10
- ;
- ; If using the Hayes Smartmodem this is unavailable without a special
- ; change.
- ;
- SPCLMENU: RET
- ;
- ;
- ; NOTE: MUST TERMINATE PRIOR TO 0400H (with Smartmodem)
- ; 0C00H (without Smartmodem)
- ;.....
- ;
- END
- ;