- ; I2TS-2.ASM - IMP overlay for AERCO RP/M with Clifford & Assc. Z-SI/O
- ; 06/01/87
- ; USES 8251A I/O (no baudrate generator)
- ;
- ;
- ; Taken from I2NH-1.ASM for N* Horizon and adapted for the Timex Sin-
- ; clair 2068 - AERCO Disk I/F with RP/M - Z-SI/O AERCO version of the
- ; the Z-SI/O RS-232C card.
- ;
- ; Can also be used with the 2050 modem card converted for RS-232C ser-
- ; vice. This overlay will not work with the stock WC-2050 modem.
- ;
- ; NOTE: You CAN use the 'stock' WC-2050 modem for communications
- ; at 300 baud onlt. You must dial the phone manually, then
- ; connect the 2050 to the phone circuit. Or you can place
- ; a switch in the 2050's 9v. line to turn the modem on and
- ; off between calls. (A sloppy way of doing it but every-
- ; body has a 2050 in the closet.)
- ;
- ; To gain the full potential that IMP can offer, build or buy a RS-232C
- ; interface and get a Hayes, Avatek or other modem that is supported by
- ; this overlay and get connected.
- ; - Notes by Dave Clifford Sysop
- ; The TIME<X>CHANGE MBBS-RCP/M
- ; (213) 329-3922
- ;
- ; You will want to look this file over carefully. There are a number of
- ; options that you can use to configure the program to suit your taste.
- ; This file adapts Timex Sinclair 2068 w/AERCO RP/M system and Clifford
- ; & Associates Z-SI/O card to IMP.
- ;
- ; Edit this file for your preferences then follow the "TO USE:" example
- ; shown below.
- ;
- ; Many terminals will clear the screen with a CTL-Z. If yours does, put
- ; a 1AH at CLEAR: (010AH). Many terminals use two characters, the first
- ; normally an ESC. For example, ESC *. In this case put '*' at CLEAR:
- ; (The ESC will automatically be typed with no CTL-character present.)
- ; If you don't know what your terminal uses, put a 0 at CLEAR: and IMP
- ; will scroll up 24 blank lines to clear the CRT for things like MENU,
- ; looking at the function key table, typing CTL-Z in command mode, etc.
- ;
- ; Use the "SET" command to change the baudrate when desired. The value
- ; at MSPEED controls the baudrate when the program is first called up.
- ;
- ; TO USE: First edit this file filling in answers for your own
- ; equipment. Then assemble with ASM.COM or equivalent
- ; assembler. Then use MLOAD to merge into the main file:
- ;
- ; MLOAD IMP.COM=IMP.COM,I2TS-1.HEX
- ;
- ; - Notes by Irv Hoff W6FFC
- ;
- ; = = = = = = = = = = = = = = = = = =
- ;
- ; 06/01/87 Improved the GOODBYE routine, added BREAK routine, needs
- ; IMP245 to use it. - Irv Hoff
- ;
- ; 12/11/86 Adapted for the Timex Sinclair computer.
- ; - Dave Clifford
- ; 09/03/85 Written to work with IMP - Irv Hoff
- ;
- ; = = = = = = = = = = = = = = = = =
- ;
- YES EQU 0FFH
- NO EQU 0
- ;
- ;
- ; Values shown are for the AERCO version Z-SI/O Card
- ; For JLO-DISK version change PORT to 0D7H and MDCTL1 to 0DFH
- ; For 2050 change PORT to 73H and MDCTL1 to 77H
- ;
- PORT EQU 73H ; Your base port (data or status)
- MDCTL1 EQU 77H ; Modem control port
- MDDATP EQU PORT ; Modem data port
- MDRCV EQU 02H ; Modem receive ready
- MDSND EQU 01H ; Modem send ready bit
- MDTXE EQU 05H ; Modem send buffer empty, holding buffer empty
- ;
- ;
- MDMODE EQU 82H ; Insures 8251 is out of mode with DTR high
- MDRSET EQU 42H ; Resets USART for additional commands
- MDSET1 EQU 4EH ; 1 stop bit, no parity, 8 bits, x16
- MDSET2 EQU 0CEH ; 2 stop bits, no parity, 8 bits, x16
- MDCOM EQU 17H ; Reset error flags, RCV, DTR, TX ready
- ;
- ;
- ;-----------------------------------------------------------------------
- ;
- ESC EQU '['-40H ; ^[ = Escape
- BELL EQU 'G'-40H ; ^G = Bell character
- LF EQU 'J'-40H ; ^J = Linefeed
- NEXTRY EQU 'K'-40H ; ^K = Try next phone number, abort this try
- CR EQU 'M'-40H ; ^M = Carriage return
- CLEARSC EQU 'Z'-40H ; ^Z = Clears screen, command mode only
- EOFCHAR EQU 'Z'-40H ; ^Z = End of file
- ;
- ;
- ;-----------------------------------------------------------------------
- ;
- ;
- ORG 0100H
- ;
- ;
- DS 3 ; Skip the data area below
- ;
- ;
- ; These routines and equates are at the beginning of the program so
- ; they can be patched by a monitor or overlay file without re-assembling
- ; the program.
- ;
- MSPEED: DB 1 ; 0=110 1=300 2=450 3=600 4=710 5=1200 103H
- ; 6=2400 7=4800 8=9600 9=19200 default
- HS2400: DB NO ; Yes=2400 bps highest speed 104H
- HS1200: DB YES ; Yes=1200 bps highest speed 105H
- RACAL: DB NO ; Yes=Racal-Vadic 1200V or 2400V or 2400PA 106H
- PROMODM: DB NO ; Yes=Prometheus ProModem 1200 bps 107H
- RESVD1: DB NO ; Reserved for special modems 108H
- RESVD2: DB NO ; Reserved for special modems 109H
- ;
- ;
- CLEAR: DB 0 ; Clear screen character (ESC not needed) 10AH
- CLOCK: DB 37 ; Clock speed in MHz x10, 25.5 MHz max. 10BH
- ; 20=2 MHh, 37=3.68 MHz, 40=4 MHz, etc.
- BYTDLY: DB 2 ; 0=0 delay 1=10ms 5=50 ms - 9=90 ms 10CH
- ; default time to send character in ter-
- ; minal mode file transfer for slow BBS
- CRDLY: DB 2 ; 0=0 delay 1=100 ms 5=500 ms - 9=900 ms 10DH
- ; default time for extra wait after CRLF
- ; in terminal mode file transfer
- NOFCOL: DB 5 ; Number of directory columns shown 10EH
- TCHPUL: DB 'T' ; T=tone, P=Pulse (Hayes 2400 modems) 10FH
- ;.....
- ;
- ;
- ADDLFD: DB NO ; Yes=add LF after CR to send file in terminal 110H
- ; mode (normally added by remote echo)
- CONVRUB: DB YES ; Yes=convert rub to backspace 111H
- CRCDFLT: DB YES ; Yes=default to CRC checking 112H
- IGNRCTL: DB YES ; Yes=CTL-chars above ^M not displayed 113H
- ;.....
- ;
- ;
- EXTCHR: DB '['-40H ; ESC = preceeds local control character 114H
- EXITCHR: DB 'E' ; Exit character 115H
- FILESND: DB 'F' ; Send file when in terminal mode 116H
- NOCONCT: DB 'N' ; Disconnect from phone line 117H
- LOGCHR: DB 'L' ; Send logon 118H
- LSTCHR: DB 'P' ; Toggle printer 119H
- UNSAVCH: DB 'R' ; Close input text buffer 11AH
- SAVECHR: DB 'Y' ; Open input text buffer 11BH
- CLEARS: DB 'Z' ; Clears screen, terminal mode 11CH
- BRKCHR: DB 'Q' ; Send a break tone 11DH
- NODTR: DB NO ; YES if no DTR and need ATH0 to disconnect 11EH
- ;.....
- ;
- ;
- ; Handles in/out ports for data and status
- ;
- I$MDCTL1: IN MDCTL1 ; 11FH
- RET ; IN modem control port 121H
- DB 0,0,0,0,0,0,0 ; Spares if needed 122H
- ;
- I$MDTXE: IN MDCTL1 ; (Needed for SIO or DART register 1 129H
- RET ; 12BH
- DB 0,0,0,0,0,0,0 ; 12CH
- ;
- I$MDDATP: MVI A,37H ; 133H
- OUT MDCTL1 ; 135H
- IN MDDATP ; 137H
- RET ; 139H
- DB 0,0,0 ; Spares if needed 13AH
- ;
- O$MDDATP: OUT MDDATP ; 13DH
- RET ; OUT modem data port 13FH
- DB 0,0,0,0,0,0,0 ; Spares if needed 140H
- ;.....
- ;
- ;
- A$MDRCV: ANI MDRCV ; 147H
- RET ; 149H
- ;
- C$MDRCV: CPI MDRCV ; 14AH
- RET ; 14CH
- ;
- A$MDSND: ANI MDSND ; 14DH
- RET ; 14FH
- ;
- C$MDSND: CPI MDSND ; 150H
- RET ; 152H
- ;
- A$MDTXE: ANI MDTXE ; 153H
- RET ; 155H
- ;
- C$MDTXE: CPI MDTXE ; 156H
- RET ; 158H
- ;.....
- ;
- ;
- ; Special exit vector, used by some computers to reset interrupt vectors
- ;
- J$EXITVEC:RET ; 159H
- DB 0,0 ; 15AH
- ;.....
- ;
- ;
- ; Jump vectors needed by each overlay
- ;
- J$GOODBYE:JMP GOODBYE ; Disconnects modem by dropping DTR 15CH
- J$INITMOD:JMP INITMOD ; Initializes modem, autosets baudrate 15FH
- J$STUPR: JMP STUPR ; SET routine to change baudrate 162H
- J$SYSVR: JMP SYSVR ; Signon message 165H
- ;.....
- ;
- ;
- ; "AT" command strings, can be replaced in individual overlay if needed
- ;
- J$STRNGA: DS 3 ; 1200 bps "AT" string 168H
- J$STRNG1: DS 3 ; 2400 bps "AT" string 16B:IMP
- ;
- ;
- ; Next fourteen lines should not be changed by user overlay as these go
- ; to specific locations in the main program, not in the overlay.
- ;
- ;
- J$CMDSPL: DS 3 ; Allows entry of baudrate on CMD line 16EH
- J$CRLF: DS 3 ; Turns up one new line on display 171H
- J$DIAL: DS 3 ; Start of dialing routine 174H
- J$DSCONT: DS 3 ; Terminates modem use 177H
- J$GOLST: DS 3 ; Printer routine, needed by Apple //e 17AH
- J$ILPRT: DS 3 ; Prints an inline string, 0 to end 17DH
- J$INBUF: DS 3 ; Stores a keybd string for comparison 180H
- J$INLNCP: DS 3 ; Inline "compare strings" routine 183H
- J$INMDM: DS 3 ; Max .1 sec wait for modem character 186H
- J$RCVRSP: DS 3 ; For 3801 I/O use (TV-803) 189H
- J$SNDCHR: DS 3 ; Sends a character to the modem 18CH
- J$SNDSTR: DS 3 ; Sends a string to the modem, $ to end 18FH
- J$TIMER: DS 3 ; .1 second timer (amount in 'B' reg.) 192H
- J$BREAK: JMP SENDBRK ; Break routine 195H
- J$NEW2: DB 0,0,0 ; For future needs 198H
- ;.....
- ;
- ;
- ; For 2400 bps auto-stepdown units
- ;
- MANUAL: DB 0 ; For manual selection flag 19BH
- J$300: JMP OK300 ; Sets baudrate to 300 baud 19CH
- J$1200: JMP OK1200 ; Sets baudrate to 1200 bps 19FH
- J$2400: JMP OK2400 ; Sets baudrate to 2400 bps 1A2H
- ;.....
- ;
- ;
- LOGPTR: DW LOGON ; Pointer to display LOGON message 1A5H
- ;
- SYSVR: CALL J$ILPRT ; Display the following line 1A7H
- DB 'Version for AERCO & Z-SI/O Card at port 73H/77H' ; 1AAH
- DB CR,LF,0
- RET
- ;.....
- ;
- ;
- ;-----------------------------------------------------------------------
- ;
- ; NOTE: You can change the SYSVER message to be longer or shorter. The
- ; end of your last routine should terminate by 0400H (601 bytes
- ; available after start of SYSVER).
- ;
- ;-----------------------------------------------------------------------
- ;
- ; You can put in a message at this location which can be called up with
- ; (special character-L). You can put in several lines. End with a 0.
- ;
- ; You can put an auto-log on for an MBBS type board like this...
- ; 'Firstname;Lastname;PASSWORD'
- ;
- LOGON: DB 'Hello from a Timex/SINCLAIR 2068 computer...'
- DB CR,LF,0
- ;
- ;-----------------------------------------------------------------------
- ;
- ; This routine sets a 300 ms break tone
- ;
- SENDBRK:
- MVI A,3FH ; DTR normal, send break tone
- JMP GOODBYE+2
- ;.....
- ;
- ;
- ; This routine sets DTR low for 300 ms to disonnect the phone
- ;
- GOODBYE:
- MVI A,3DH ; Send break, turn off DTR
- OUT MDCTL1 ; Send to status port
- MVI B,3 ; Delay 300 ms to hang up phone
- CALL J$TIMER
- MVI A,37H ; Normal send/receive with DTR
- OUT MDCTL1 ; Send to status port
- RET
- ;.....
- ;
- ;
- ; Sets 8251 to 8 bits, DTR, RCV and TX ready
- ;
- INITMOD:
- MVI A,MDMODE ; Insure 8251 is out of mode
- OUT MDCTL1
- XTHL ; Small delay to complete command
- XTHL
- MVI A,MDRSET ; Reset the 8251A for new command
- OUT MDCTL1
- XTHL ; Small delay to complete command
- XTHL
- MVI A,MDSET1 ; Set stop pulse, no parity 8 bits, x16
- OUT MDCTL1
- XTHL ; Small delay to complete command
- XTHL
- MVI A,MDCOM ; Error reset, RCV, DTR, TX ready
- OUT MDCTL1
- XTHL ; Small delay to complete command
- XTHL
- ;
- LDA MSPEED ; Get the selected value
- CPI 1 ; 300 bps
- JZ OK300
- CPI 5 ; 1200 bps
- JZ OK1200
- JMP STUPR1 ; Else ask what is wanted
- ;.....
- ;
- ;
- STUPR: CALL J$CMDSPL ; Gives us CMDBUF+6
- JNC STUPR2
- ;
- STUPR1: CALL J$ILPRT
- DB 'Input Baud Rate (300, 1200): ',0
- LXI D,BAUDBUF ; Point to new input buffer
- CALL J$INBUF
- CALL J$CRLF
- LXI D,BAUDBUF+2
- ;
- STUPR2: CALL J$INLNCP ; Compare BAUDBUF+2 with chars. below
- DB '300',0
- JNC OK300 ; Go if got match
- CALL J$INLNCP
- DB '1200',0
- JNC OK1200
- CALL J$ILPRT ; All matches failed, tell operator
- DB '++ Incorrect entry ++',CR,LF,BELL,CR,LF,0
- JMP STUPR1 ; Try again
- ;
- OK300: MVI A,1 ; MSPEED 300 baud value
- MVI B,BD300 ; Get 300 baud parameters in 'HL'
- JMP LOADBD ; Go load them
- ;
- OK1200: MVI A,5
- MVI B,BD1200
- JMP LOADBD
- ;
- OK2400: JMP OK1200 ; Stock Z-SI/O does not support 2400 bps
- ;
- LOADBD: STA MSPEED ; Change time-to-send to match baudrate
- MVI A,87H ; Insure out of mode
- OUT MDCTL1 ; Modem status port
- XCHG ; Slight extra delay
- MVI A,40H ; Initialize 8251
- OUT MDCTL1 ; Modem status port
- MOV A,B ; Get the speed currently wanted
- OUT MDCTL1 ; Modem status port
- XCHG ; Slight pause
- MVI A,17H ; DTR, RCV, XMT, error reset
- OUT MDCTL1 ; Modem status port
- IN PORT ; Clear data port
- XRA A ; Clear the input
- RET
- ;.....
- ;
- ;
- ; Table of baudrate parameters
- ;
- BD300 EQU 4FH ; 300 baud, x64
- BD1200 EQU 4EH ; 1200 bps, x16
- ;
- BAUDBUF:DB 10,0,0,0,0,0
- DB 0,0,0,0,0,0
- ;
- ; end
- ;-----------------------------------------------------------------------
- ;
- ; NOTE: Must terminate by 0400H
- ;
- END