AST RESEARCH, INC. TECHNICAL BULLETIN #0769A 11-10-92
=============================================================================
AST SVGA 14" LOW RADIATION MONITOR
PROBLEM: When using the 1024x768 mode on the SVGA 14" low radiation
monitor, the picture will shift to the left.
CAUSE: This is due to a timing issue within the monitor itself.
AFFECTED
SYSTEMS: SVGA 14" low radiation monitor part number 500902-XXX
revision A.
SOLUTION: Replace revision A monitor with a revision B monitor part
number 500902-001, 002, or 003.
NOTE: The part number 500902-XXX on the packing box will remain revision A.
However, the part number on the monitor itself will change to 230253-
XXX revision B.