home *** CD-ROM | disk | FTP | other *** search
/ Media Share 9 / MEDIASHARE_09.ISO / dbase / rsa2000.zip / RSA2000.EXE / lha / RSAHELP.MSG < prev    next >
Text File  |  1993-03-14  |  14KB  |  429 lines

  1. @@H00
  2.  Use this listbox to select the technical
  3.  analysis function to be charted.  When
  4.  the chart is displayed, the following
  5.  keyboard options are available:
  6.  
  7.  F1 or Mouse Button 1 - Next Chart
  8.  F2 - Display Table Function Values
  9.  F4 - Enable/Disable Pause Option
  10.  F5 - Modify Graph Colors
  11.  F6 or TAB - Next Table Function
  12.  F7 or SHIFT-TAB - Previous Table Function
  13.  F8 - Display NOTE File
  14.  F9 - Display Earnings Chart
  15.  F10- Print Graph
  16.  Alt F3 & Alt F4 - Change Graph Range
  17.  0 thru 9 - Graph Zoom
  18.  ESC or Mouse Button 2 - Exit
  19. @@H01
  20.  Use this pushbutton to select the window
  21.  for modification of RSA technical analysis
  22.  functions.  Nearly all parameters can be
  23.  modified as you choose.  You may even
  24.  define your own analysis functions.
  25. @@H02
  26.  Use this pushbutton to select the window
  27.  for display and update of historical stock
  28.  data.  The update option is available only
  29.  with RSA data files.
  30. @@H03
  31.  Use this pushbutton to select the window
  32.  for display and update of daily stock
  33.  data.  The update option is available
  34.  only with RSA data files.
  35. @@H04
  36.  Use this pushbutton to terminate the RSA
  37.  program.  Any modifications to parameters,
  38.  colors, or data values will be saved in
  39.  the RSA data files before terminating.
  40. @@H05
  41.  Use this pushbutton to select the next
  42.  stock symbol in your stock database.
  43. @@H06
  44.  Use this pushbutton to select the previous
  45.  stock symbol in your stock database.
  46. @@H07
  47.  Use this pushbutton to select the window
  48.  for display of table column values for the
  49.  RSA technical analysis functions.  This
  50.  window will display 10 columns of data
  51.  values.
  52. @@H08
  53.  Use this pushbutton to display a listbox
  54.  for selection of other processing options.
  55. @@H09
  56.  Use this listbox for selection of other
  57.  processing options.
  58. @@H10
  59.  Use this entry field to modify the
  60.  company name for the current stock
  61.  symbol.  Modification of stock data
  62.  is available only for RSA data files.
  63. @@H11
  64.  Use this entry field to modify the
  65.  first target price for the current
  66.  stock symbol.  The "TARGET PRICE"
  67.  can be charted by defining a table
  68.  function with a table column function
  69.  type of "TARGET PRICE".
  70. @@H12
  71.  Use this entry field to modify the
  72.  second target price for the current
  73.  stock symbol.  The "TARGET PRICE"
  74.  can be charted by defining a table
  75.  function with a table column function
  76.  type of "TARGET PRICE".
  77. @@H13
  78.  Use this entry field to activate the
  79.  time interval between successive
  80.  displays of stock charts.  Successive
  81.  charts will be displayed with a time
  82.  delay from the PAUSE TIME parameter.
  83. @@H14
  84.  Use this entry field to modify the
  85.  time interval between successive
  86.  displays of stock charts.  This time
  87.  interval will only be used when the
  88.  PAUSE/REPEAT option is set to YES.
  89. @@H15
  90.  Use this listbox to select the technical
  91.  analysis function table column to be
  92.  modified.  A start list parameter defines
  93.  the maximum number of table columns in
  94.  each technical analysis table function.
  95. @@H16
  96.  Use this pushbutton to select the graph
  97.  type for this technical analysis function
  98.  table column.  Each chart can be positioned
  99.  in one of the selected screen positions or
  100.  select NONE to prevent charting of this
  101.  table column.
  102. @@H17
  103.  Use this pushbutton to select the graph
  104.  color for this technical analysis function
  105.  table column.  VGA and EGA color monitors
  106.  have a choice of either 16 or 64 color
  107.  values depending on the start list option.
  108. @@H18
  109.  Use this pushbutton to select the graph
  110.  scale for this technical analysis function.
  111.  Graph scale is necessary so that a chart
  112.  and its moving average will be plotted on
  113.  the same axis values.
  114. @@H19
  115.  Use this pushbutton to modify other
  116.  parameter values associated with this
  117.  technical analysis table column.
  118. @@H20
  119.  Terminate the modification of this
  120.  technical analsyis function and return
  121.  to the technical analysis table function
  122.  selection window.
  123. @@H21
  124.  Use this pushbutton to modify the name of
  125.  this technical analysis table function.
  126.  The analysis function names are listed in
  127.  the technical analysis function selection
  128.  window.
  129. @@H22
  130.  Use this pushbutton to modify the column
  131.  type of this technical analysis function
  132.  table column.  You may define and create
  133.  your own technical analysis functions.
  134. @@H23
  135.  Use this pushbutton to modify the column
  136.  name of this technical analysis function
  137.  table column.  This column name will be
  138.  displayed on the analysis function chart.
  139. @@H24
  140.  Use this listbox to select the technical
  141.  analysis function moving average type.
  142.  After the values for this analysis function
  143.  table column are calculated, the moving
  144.  average will then be calculated.
  145. @@H25
  146.  Use this listbox to select the technical
  147.  analysis function moving average time.
  148.  After the values for this analysis function
  149.  table column are calculated, the moving
  150.  average will then be calculated.
  151. @@H26
  152.  Use this listbox to select colors for each
  153.  RSA text window.  The color selection
  154.  option is only available when the 64 color
  155.  start list option is specified.
  156. @@H27
  157.  Use this listbox to select the graph color
  158.  matrix for the technical analysis table
  159.  functions.  VGA and EGA color monitors
  160.  have a choice of either 16 or 64 color
  161.  values depending on the start list option.
  162.  
  163.  Color 00 - Graph Background
  164.  Color 01-07 - Chart Colors
  165.  Color 08 - Stock Symbol Labels
  166.  Color 09 - Stock Symbol Names
  167.  Color 10 - X-Axis Days
  168.  Color 11 - X-Axis Dates
  169.  Color 12 - Horizontal Hash Lines
  170.  Color 13 - Vertical Hash Lines
  171.  Color 14 - Graph Inner Borders
  172.  Color 15 - Graph Outer Borders
  173. @@D00
  174.  Use this listbox to select the daily
  175.  stock data values to be displayed or
  176.  modified.  Modification of data files is
  177.  available only with RSA data files.  Use
  178.  the cursor arrow keys and Page Up/Down to
  179.  scroll in the window.
  180. @@D01
  181.  Use this pushbutton to select the next
  182.  group of 260 stocks.  Daily stock data
  183.  will be displayed in the listbox for 260
  184.  stocks or less each time.
  185. @@D02
  186.  Use this pushbutton to select the previous
  187.  group of 260 stocks.  Daily stock data
  188.  will be displayed in the listbox for 260
  189.  stocks or less each time.
  190. @@D03
  191.  Use this pushbutton to modify the daily
  192.  stock data for the day selected in the
  193.  listbox window.  Modification of data is
  194.  available only for RSA data files.
  195. @@D04
  196.  Use this pushbutton to display a selection
  197.  list of other available processing options.
  198. @@D05
  199.  Use this entry field to modify the daily
  200.  stock price value.
  201. @@D06
  202.  Use this entry field to modify the daily
  203.  stock volume value.
  204. @@D07
  205.  Use this listbox to display a selection
  206.  list of other available processing options.
  207.  The LOG TO DISK option will write the
  208.  window data to the RSA disk log file.
  209. @@Y00
  210.  Use this listbox to select the historical
  211.  stock data values to be displayed or
  212.  modified.  Modification of data files is
  213.  available only with RSA data files.  Use
  214.  the cursor arrow keys and Page Up/Down to
  215.  scroll in the window.
  216. @@Y01
  217.  Use this pushbutton to select the next
  218.  stock symbol in your stock database.
  219. @@Y02
  220.  Use this pushbutton to select the previous
  221.  stock symbol in your stock database.
  222. @@Y03
  223.  Use this pushbutton to modify the historical
  224.  stock data for the day selected in the
  225.  listbox window.  Modification of data is
  226.  available only for RSA data files.
  227. @@Y04
  228.  Use this pushbutton to display a selection
  229.  list of other available processing options.
  230. @@Y05
  231.  Use this entry field to modify the
  232.  historical stock price value.
  233. @@Y06
  234.  Use this entry field to modify the
  235.  historical stock volume value.
  236. @@Y07
  237.  Use this entry field to modify the
  238.  historical stock price split values.
  239. @@Y08
  240.  Use this entry field to modify the
  241.  historical mutual fund distribution
  242.  value.
  243. @@Y09
  244.  Use this listbox to display a selection
  245.  list of other available processing options.
  246.  The LOG TO DISK option will write the
  247.  window data to the RSA disk log file.
  248. @@P00
  249.  This listbox displays system parameters.
  250.  The LAST DAY UPDATED is the latest date
  251.  of data in the stock database.
  252.  The DAY 1 parameters are used to determine
  253.  which date the current year of stock data
  254.  begins with.  Avoid changing these values.
  255.  The correct values should be automatically
  256.  calculated as:
  257.       1992 - 01/06/92    1995 - 01/09/95
  258.       1993 - 01/04/93    1996 - 01/08/96
  259.       1994 - 01/03/94    1997 - 01/06/97
  260.  
  261.  The FIRST DAY ADJUST will need to be set
  262.  about once each six years to make the
  263.  DAY 1 value equal to the first Monday of
  264.  the year with data.
  265. @@P01
  266.  Use this pushbutton to exit from the
  267.  parameter update window.  Parameter changes
  268.  will be saved in disk file when program
  269.  is terminated.
  270. @@P02
  271.  Use this pushbutton to increase the value
  272.  of the selected parameter.
  273. @@P03
  274.  Use this pushbutton to decrease the value
  275.  of the selected parameter.
  276. @@I00
  277.  This listbox is used for selection of a
  278.  technical analysis function column type.
  279.  After the column type is modified, the
  280.  parameters associated the the column
  281.  type must be selected also.
  282. @@I01
  283.  This listbox is used for selection of a
  284.  graph window size and location for the
  285.  technical analysis function table column
  286.  graph. Select NONE if no graph is desired
  287.  for this table column.
  288. @@I02
  289.  This listbox is used for selection of a
  290.  moving average type for this technical
  291.  analysis function table column.  The
  292.  moving average calculation is performed
  293.  after the table column function values
  294.  are calculated.
  295. @@I03
  296.  This listbox is used for graph scale
  297.  selection.  Graph scale is necessary
  298.  so that a chart and its moving average
  299.  will be displayed on the same scale.
  300. @@I04
  301.  This listbox is used for selection of a
  302.  column math table column function type.
  303.  Column math provides math functions on
  304.  table columns and constants.
  305. @@I05
  306.  This listbox is used for selection of a
  307.  time offset and time interval.  The
  308.  analysis function value will then be
  309.  modified to be the minimum, maximum, or
  310.  average value in the selected time period.
  311. @@I06
  312.  This listbox is used for selection of a
  313.  time offset and time interval.  The
  314.  analysis function value will then be
  315.  modified to be the minimum, maximum, or
  316.  average value in the selected time period.
  317.  The usual setting for these parameters is:
  318.     VALUE SELECT = AVERAGE VALUE
  319.     TIME PERIOD  = 1 DAY
  320.     TIME OFFSET  = 0
  321.  A time offset of zero and time period of
  322.  one day will result in no modification of
  323.  the analysis function column values.
  324. @@I07
  325.  This listbox is used for selection of a
  326.  time offset and time interval.  The
  327.  analysis function value will then be
  328.  modified to be the minimum, maximum, or
  329.  average value in the selected time period.
  330. @@I08
  331.  This listbox is used for selection of a
  332.  time offset and time interval.  The
  333.  analysis function value will then be
  334.  modified to be the minimum, maximum, or
  335.  average value in the selected time period.
  336. @@J00
  337.  This entry field is used for changing the
  338.  technical analysis function table name.
  339.  The table names are listed in the table
  340.  function selection window.
  341. @@J01
  342.  This entry field is used for changing the
  343.  technical analysis table column name.
  344.  The table column names will be displayed
  345.  on the analysis graphs.
  346. @@K00
  347.  Use this scrollbar to select the graph
  348.  color for this technical analysis function
  349.  table column.  VGA and EGA color monitors
  350.  have a choice of either 16 or 64 color
  351.  values depending on the start list option.
  352. @@K01
  353.  Use this scrollbar to select the technical
  354.  analysis function moving average time.
  355.  After the values for this analysis function
  356.  table column are calculated,  the moving
  357.  average will then be calculated.
  358. @@K02
  359.  Use this scrollbar to select the symbol
  360.  number to be used in this table column
  361.  calculation.  The value usually selected
  362.  will be CURRENT which will use the current
  363.  stock symbol.
  364. @@K03
  365.  Use this scrollbar to select the column
  366.  number used as an operand in a column math
  367.  function type.
  368. @@K04
  369.  Use this scrollbar to select the column
  370.  number or constant used as an operand in
  371.  a column math function type.
  372. @@K05
  373.  This scrollbar is used for selection of a
  374.  time offset and time interval.  The
  375.  analysis function value will then be
  376.  modified to be the minimum, maximum, or
  377.  average value in the selected time period.
  378. @@K06
  379.  This scrollbar is used for selection of a
  380.  time offset and time interval.  The
  381.  analysis function value will then be
  382.  modified to be the minimum, maximum, or
  383.  average value in the selected time period.
  384. @@K07
  385.  Use this scrollbar to select the time
  386.  period used as an parameter in a this
  387.  table column function.
  388. @@K08
  389.  Use this scrollbar to select the time
  390.  period used as an parameter in a this
  391.  table column function.
  392. @@K09
  393.  Use this scrollbar to select the column
  394.  number used as an operand in a column
  395.  change function type.
  396. @@K10
  397.  Use this scrollbar to select the column
  398.  number used as an operand in a this
  399.  table column function.
  400. @@K11
  401.  Use this scrollbar to select use of the
  402.  absolute value operation to change
  403.  all negative values to positive values.
  404. @@K12
  405.  This scrollbar is used for selection of a
  406.  time offset and time interval.  The
  407.  analysis function value will then be
  408.  modified to be the minimum, maximum, or
  409.  average value in the selected time period.
  410. @@K13
  411.  This scrollbar is used for selection of a
  412.  time offset and time interval.  The
  413.  analysis function value will then be
  414.  modified to be the minimum, maximum, or
  415.  average value in the selected time period.
  416. @@O01
  417.  Use this pushbutton to save changes which
  418.  have been made to values in the specified
  419.  file.  If values are saved in the disk
  420.  file,  then the new values will also be
  421.  used when program is executed again.
  422. @@O02
  423.  Use this pushbutton to cancel changes which
  424.  have been made to values in the specified
  425.  file.  If values are not saved in the disk
  426.  file,  then the new values will not be
  427.  used when program is executed again.
  428. @
  429.