home *** CD-ROM | disk | FTP | other *** search
/ Merciful 3 / Merciful_Release_3.bin / software / s / scantekv2.7r.lha / Scantek / ReadMe < prev    next >
Text File  |  1996-12-07  |  6KB  |  187 lines

  1.  
  2.                         ScanTek 2.7
  3.  
  4.                     A scanner driver for
  5.                Microtek, Highscreen and Mustek
  6.                       Flatbed Scanner
  7.  
  8.  
  9.             © Copyright 1995/1996 Waldemar Zöhner
  10.  
  11.                   Get It, Feel It, Love It
  12.  
  13.  
  14.  Overview
  15. ----------
  16.  
  17.  The ScanTek scanner driver has the following features:
  18.  
  19.  1. Support of the following SCSI Microtek scanner models:
  20.         MICROTEK IISP, MICROTEK II, HIGHSCREEN Flatbed Color IIs,
  21.         ScanMaker E3, ScanMaker 35t
  22.  
  23.     Support of the following SCSI Mustek scanner models:
  24.         Three Pass Scanners:
  25.         6000CX, 8000CX (not tested), 12000CX (not tested) all should work
  26.  
  27.         One or Single Pass Scanners:
  28.         6000SP, 8000SP (not tested), 12000SP (not tested) all should work
  29.         6000CZ (not tested), 8000CZ (not tested)
  30.  
  31.         600IISP, 800IISP (not tested) all should work
  32.  
  33.     If your scanner is not mentioned in the list above try it and
  34.     give me a response whether it works or not.
  35.  
  36.     Attention: Mustek scanners have a critical SCSI interface. It
  37.                was reported to me that these scanners may not work
  38.                with the A3000(T) internal SCSI interface. It is
  39.                possible that these scanners do not work with other
  40.                SCSI host adapters, either.
  41.                But the Mustek 6000CX works in combination with an
  42.                Oktagon SCSI host adapter.
  43.                Be sure to disable reselection for Mustek scanners
  44.                on your SCSI host adapter. Otherwise your system may
  45.                not boot.
  46.  
  47.  
  48.  2. Support of black/white, built-in halftone (dither), one-pass-color-scan,
  49.     three pass color scan, grey, red, green and blue scan.
  50.  
  51.  3. Individual setting of resolution, scanning frame, contrast, shadow,
  52.     midtone, highlight, exposure time and scanning speed for download to the
  53.     scanner.
  54.  
  55.  4. Download of a color look up table (gamma correction table ) to the scanner
  56.     supported.
  57.  
  58.  5. Scanning to IFF File of 1, 8 or 24 bit color depth. The maximum size of
  59.     the scanned image is independent from the RAM size. After the scanning
  60.     process it is possible to start an external program.
  61.  
  62.  6. GUI for preview and configuration of the driver. You need Kickstart 2.04
  63.     but Kickstart 3.0 is recommended.
  64.  
  65.  7. Sizeable preview window in black/white or grey scale. Color preview
  66.     on Cybergraphix screens (15, 16 or 24 bit necessary).
  67.     There are much more skilled programs to view and manipulate the scanned
  68.     images in color. (A tool like ADPRO, IMAGE FX or so is needed, if you
  69.     want to do sophisticated postproduction)
  70.  
  71.  8. Screenmode requester to define custom screen for working. The actual public
  72.     screen is supported as well
  73.  
  74.  9. Configurable SCSI device and SCSI ID. The driver supports only SCSI
  75.     connectable scanners.
  76.  
  77.  10. The driver is tested with the following SCSI drivers: oktagon.device and
  78.      gvpscsi.device V4.5.
  79.  
  80.  11. ScanTek is written using SAS C 6.55.
  81.  
  82.  11. ScanTek is SHAREWARE.
  83.  
  84.  12. The non registered version of ScanTek is a full working version, but all
  85.      scanned images have black lines to motivate you to register.
  86.      Additionally the maximum size of the preview is restricted.
  87.  
  88.  
  89.  
  90.  History
  91. ---------
  92.  
  93.  V1.0  30 Nov. 1995
  94.  
  95.    - first public release
  96.  
  97.  
  98.  V1.1  17 Dec. 1995
  99.  
  100.    - detection of Microtek scanner via SCSI inquiry enhanced
  101.    - stepping of resolution slider adapted to expanded base resolution
  102.    - calculation of scanning frame size data modified
  103.  
  104.  
  105.  V1.2   3 Jan. 1996
  106.  
  107.    - Debug output data revised and enhanced
  108.    - Max Frame Setting setting introduced
  109.    - Start of external program possible
  110.    - Window positions are remembered and saved
  111.    - Configuration file enhanced
  112.  
  113.  
  114.  V1.3  25 Feb. 1996
  115.  
  116.    - Detection of new ScanMaker E3 Flatbed scanner implemented
  117.    - Special adaption for E3 to use 8.5 * 13.5 inch scanning frame
  118.      (due to E3 inquiry data the max frame size is 8.5 * 11.69 inch)
  119.    - No start of the external program, if the scanning process is aborted
  120.    - Higher dpi rates for ScanMaker 35t (slide scanner) possible
  121.      Preview image schould look better now.
  122.    - "Main Control" window and gadgets modified
  123.    - Debug filename "ScanTek.log" can be overriden through CLI or Tooltype
  124.  
  125.  
  126.  V2.0  30 Apr. 1996
  127.  
  128.    - Preview in color mode with proper options values
  129.    - Use of expanded Contrast and Exposure Time selections on certain scanners
  130.    - X and Y Aspect Ratio in scanned color images is now correct
  131.    - ScanMaker E3 does not support undocumentated red, gree and blue scanning
  132.    - Lookup Table command supported (Gamma Correction on certain scanner
  133.      possible)
  134.    - Scanning Frame Setting is now more intuitive
  135.    - Reverse image scanning supported (only on certain scanners possible)
  136.    - Accurate scanning frame definition. Scanning frame is now more precise.
  137.  
  138.  
  139.  V2.1  5 July 1996
  140.  
  141.    - Preview now fully supported for Mustek 6000CX
  142.    - Special adaption for Mustek 6000CX to use 8.5 * 14 inch scanning frame
  143.  
  144.  
  145.  V2.2 26 July 1996
  146.  
  147.    - Enhanced support for Mustek scanners
  148.      "Exposure Time" and "Contrast" parameters are now correct
  149.    - Gamma value "All" now works on threepass scanner
  150.    - Alternative Black/White scanning mode
  151.  
  152.  
  153.  V2.3  6 Sept. 1996
  154.  
  155.    - Color Preview on Cybergraphix screens in true color mode (15, 16 or 24 bit)
  156.      for onepass flatbed scanners
  157.    - Grey/Red/Green/Blue Preview on Cybergraphix screens in true color mode
  158.      (15, 16 or 24 bit) for threepass and onepass flatbed scanners
  159.    - Change and recall of predefined resolution values
  160.  
  161.  
  162.  V2.4 10 Sept. 1996
  163.  
  164.    - Support of Mustek SCSI one pass color scanners in color mode and
  165.      parameter ranges.
  166.    - ScanTek can now open its GUI windows on the actual public screen.
  167.  
  168.  
  169.  V2.5  5 Oct. 1996
  170.  
  171.    - Workaround to handle strange color mode behaviour of Mustek
  172.      one pass scanners
  173.    - Reverse scanning in black and white mode introduced
  174.  
  175.  
  176.  V2.6  30 Oct. 1996
  177.  
  178.    - Full support of Mustek one pass scanners
  179.    - Recognition of Mustek scanners enhanced
  180.  
  181.  
  182.  V2.7  6 Dec. 1996
  183.  
  184.    - Recognition and handling of new Mustek scanners enhanced
  185.  
  186.    - Recognition of Microtek ScanMaker E6 adapted
  187.