home *** CD-ROM | disk | FTP | other *** search
/ ftp.cvut.cz / DOS_LEGACY_DRIVERS_2008.zip / DOS_LEGACY_DRIVERS / eisa / !icu1000.cfg < prev    next >
Text File  |  2008-01-06  |  5KB  |  201 lines

  1. BOARD
  2.      ID          = "ICU1000"
  3.      NAME        = "NCL538/NCL539"
  4.      MFR         = "National Computer Ltd."
  5.      VERSION     = 1,0
  6.      CATEGORY    = "MSD"
  7.      SLOT        = ISA16
  8.      COMMENTS    = "Floppy Drives Supported: NCL 538: Two 360KB, 720KB, 1.2MB,\n
  9.                     or 1.44MB; NCL 539: None"
  10.  
  11. JUMPER(1) = 1
  12.      NAME = "Floppy Drive port Address"
  13.      JTYPE = TRIPOLE
  14.      VERTICAL = NO
  15.      LABEL = LOC(1) "JP1"
  16.      FACTORY = LOC(1) 0
  17. JUMPER(2) = 1
  18.      NAME = "BIOS Address"
  19.      JTYPE = TRIPOLE
  20.      VERTICAL = NO
  21.      LABEL = LOC(1) "JP2"
  22.      FACTORY = LOC(1) 1
  23. JUMPER(3) = 1
  24.      NAME = "Floppy Drive Interrupt"
  25.      JTYPE = TRIPOLE
  26.      VERTICAL = NO
  27.      LABEL = LOC(1) "JP3"
  28.      FACTORY = LOC(1) 0
  29. JUMPER(4) = 1
  30.      NAME = "Floppy Drive DMA ACK"
  31.      JTYPE = TRIPOLE
  32.      VERTICAL = NO
  33.      LABEL = LOC(1) "JP4"
  34.      FACTORY = LOC(1) 0
  35. JUMPER(5) = 1
  36.      NAME = "IRQ Buffered"
  37.      JTYPE = TRIPOLE
  38.      VERTICAL = NO
  39.      LABEL = LOC(1) "JP5"
  40.      FACTORY = LOC(1) 0
  41. JUMPER(6) = 1
  42.      NAME = "Floppy Drive DMA Request"
  43.      JTYPE = TRIPOLE
  44.      VERTICAL = NO
  45.      LABEL = LOC(1) "JP6"
  46.      FACTORY = LOC(1) 0
  47. JUMPER(7) = 1
  48.      NAME = "Hard Drive Interrupt"
  49.      JTYPE = TRIPOLE
  50.      VERTICAL = NO
  51.      LABEL = LOC(1) "JP7"
  52.      FACTORY = LOC(1) 0
  53. JUMPER(8) = 1
  54.      NAME = "Zero wait state"
  55.      JTYPE = PAIRED
  56.      VERTICAL = NO
  57.      LABEL = LOC(1) "JP8"
  58.      FACTORY = LOC(1) 0
  59. JUMPER(9) = 1
  60.      NAME = "BIOS"
  61.      JTYPE = PAIRED
  62.      VERTICAL = NO
  63.      LABEL = LOC(1) "JP9"
  64.      FACTORY = LOC(1) 0
  65. JUMPER(10) = 1
  66.      NAME = "Hard Drive Port Address"
  67.      JTYPE = PAIRED
  68.      VERTICAL = NO
  69.      LABEL = LOC(1) "JP10"
  70.      FACTORY = LOC(1) 0
  71. JUMPER(11) = 1
  72.      NAME = "Mode"
  73.      JTYPE = PAIRED
  74.      VERTICAL = NO
  75.      LABEL = LOC(1) "JP11"
  76.      FACTORY = LOC(1) 0
  77.  
  78. FUNCTION = "BIOS Address"
  79.      CHOICE = "C8000"
  80.        FREE
  81.        MEMORY = 16K
  82.        ADDRESS = 0C8000H 
  83.        WRITABLE = NO
  84.        MEMTYPE = OTH
  85.        SHARE = NO
  86.        INIT = JUMPER(2) LOC(1) 0
  87.      CHOICE = "CC000"
  88.        FREE
  89.        MEMORY = 16K
  90.        ADDRESS = 0CC000H 
  91.        WRITABLE = NO
  92.        MEMTYPE = OTH
  93.        SHARE = NO
  94.        INIT = JUMPER(2) LOC(1) 1
  95.      CHOICE = "Disabled"
  96.        DISABLE = YES
  97.  
  98. FUNCTION = "Floppy Drive Port Address"
  99.      CHOICE = "3F2-3F7"
  100.        FREE
  101.        PORT = 03F2H-03F7H
  102.        INIT = JUMPER(1) LOC(1) 0
  103.      CHOICE = "372-377"
  104.        FREE
  105.        PORT = 0372H-0377H
  106.        INIT = JUMPER(1) LOC(1) 1
  107.      CHOICE = "Disabled"
  108.        DISABLE = YES
  109. FUNCTION = "Floppy Drive Interrupt"
  110.      CHOICE = "IRQ6"
  111.        FREE
  112.        IRQ = 6
  113.        INIT = JUMPER(3) LOC(1) 0
  114.      CHOICE = "IRQ10"
  115.        FREE
  116.        IRQ = 10
  117.        INIT = JUMPER(3) LOC(1) 1
  118.      CHOICE = "Disabled"
  119.        DISABLE = YES
  120.  
  121. FUNCTION = "Floppy Drive DMA ACK"
  122.      CHOICE = "DACK2"
  123.        FREE
  124.        DMA = 2
  125.        SHARE = "DMA2"
  126.        INIT = JUMPER(4) LOC(1) 0
  127.      CHOICE = "DACK3"
  128.        FREE
  129.        DMA = 3
  130.        SHARE = "DMA3"
  131.        INIT = JUMPER(4) LOC(1) 1
  132.  
  133. FUNCTION = "IRQ Buffered"
  134.      CHOICE = "Non Buffered"
  135.        FREE
  136.        INIT = JUMPER(5) LOC(1) 0
  137.      CHOICE = "Buffered"
  138.        FREE
  139.        INIT = JUMPER(5) LOC(1) 1
  140.      CHOICE = "Disabled"
  141.        DISABLE = YES
  142.  
  143. FUNCTION = "Floppy Drive DMA Request"
  144.      CHOICE = "DRQ2"
  145.        FREE
  146.        DMA = 2
  147.        SHARE = "DMA2"
  148.        INIT = JUMPER(1) LOC(1) 0
  149.      CHOICE = "DRQ3"
  150.        FREE
  151.        DMA = 3
  152.        SHARE = "DMA3"
  153.        INIT = JUMPER(1) LOC(1) 1
  154.  
  155. FUNCTION = "Hard Drive Interrupt"
  156.      CHOICE = "IRQ14"
  157.        FREE
  158.        IRQ = 14
  159.        INIT = JUMPER(7) LOC(1) 0
  160.      CHOICE = "IRQ15"
  161.        FREE
  162.        IRQ = 15
  163.        INIT = JUMPER(7) LOC(1) 1
  164.  
  165. FUNCTION = "Zero wait state"
  166.     CHOICE = "Diabled"
  167.        DISABLE = YES
  168.        FREE
  169.        INIT = JUMPER(8) LOC(1) 1
  170.      CHOICE = "Enable"
  171.        FREE
  172.        INIT = JUMPER(8) LOC(1) 0
  173.  
  174. FUNCTION = "BIOS"
  175.      CHOICE = "Enable"
  176.        FREE
  177.        INIT = JUMPER(9) LOC(1) 1
  178.      CHOICE = "Diabled"
  179.        DISABLE = YES
  180.        FREE
  181.        INIT = JUMPER(9) LOC(1) 0
  182.  
  183. FUNCTION = "Hard Drive Port Addres"
  184.      CHOICE = "1F0-1F7"
  185.        FREE
  186.        PORT = 01F0H-01F7H
  187.        INIT = JUMPER(10) LOC(1) 0
  188.      CHOICE = "170-177"
  189.        FREE
  190.        PORT = 0170H-0177H
  191.        INIT = JUMPER(10) LOC(1) 1
  192.  
  193. FUNCTION = "Mode"
  194.      CHOICE = "Normal Operation"
  195.        FREE
  196.        INIT = JUMPER(11) LOC(1) 0
  197.      CHOICE = "Self-diagnostic"
  198.        FREE
  199.        INIT = JUMPER(11) LOC(1) 1
  200.  
  201.