home *** CD-ROM | disk | FTP | other *** search
/ ftp.cvut.cz / DOS_LEGACY_DRIVERS_2008.zip / DOS_LEGACY_DRIVERS / eisa / !icu0820.cfg < prev    next >
Text File  |  2008-01-06  |  2KB  |  91 lines

  1. BOARD
  2.      ID = "ICU0820"
  3.      NAME = "Metheus Premier 928"
  4.      MFR = "Metheus Corporation"
  5.      VERSION = 1,0
  6.      CATEGORY = "VID"
  7.      SLOT = ISA16
  8.      COMMENTS = "Metheus Premier 928"
  9.  
  10.  
  11. SOFTWARE(1) = "Use INSTALL.EXE to configure the Stealth Pro or 24. \n"
  12.  
  13. SWITCH(1) = 10
  14.      NAME = "SW1"
  15.      STYPE = DIP
  16.      VERTICAL = NO
  17.      REVERSE = YES
  18.      LABEL = LOC(1-10) "1" "2" "3" "4" "5" "6" "7" "8" "9" "10"
  19.      FACTORY = LOC(1-10) 0100111110
  20.  
  21. SWITCH(2) = 4
  22.      NAME = "SW2"
  23.      STYPE = DIP
  24.      VERTICAL = NO
  25.      REVERSE = YES
  26.      LABEL = LOC(1 2 3 4) "1" "2" "3" "4"
  27.      FACTORY = LOC(1 2 3 4) 0011
  28.  
  29. JUMPER(2) = 1
  30.      NAME = "J2"
  31.      JTYPE = PAIRED
  32.      VERTICAL = YES
  33.      LABEL = LOC(1) "J2"
  34.      FACTORY = LOC(1) 0
  35.  
  36. JUMPER(3) = 1
  37.      NAME = "J3"
  38.      JTYPE = TRIPOLE
  39.      VERTICAL = YES
  40.      LABEL =  LOC(1) "J3"
  41.      FACTORY = LOC(1) 0
  42.  
  43. FUNCTION = "IRQ"
  44.      CHOICE = "Disabled"
  45.        DISABLE = YES
  46.        FREE
  47.        INIT = JUMPER(2) LOC(1) 0
  48.      CHOICE = "Enabled"
  49.        FREE
  50.        IRQ = 9
  51.        INIT = JUMPER(2) LOC(1) 1
  52.  
  53. FUNCTION = "I/O Address"
  54.      CHOICE = "220H"
  55.        FREE
  56.        PORT = 0220H
  57.        INIT = JUMPER(3) LOC(1) 0
  58.      CHOICE = "300H"
  59.        FREE
  60.        PORT = 0300H
  61.        INIT = JUMPER(3) LOC(1) 1
  62.  
  63. FUNCTION = "Video Mode"
  64.      CHOICE = "60@640x480/800x600,43(I)@1024x768/1280x1024"
  65.        FREE
  66.        INIT = SWITCH(2) LOC(1 2 3 4) 0011
  67.      CHOICE = "60@640X480/800X600/1024X768/1280X1024"
  68.        FREE
  69.        INIT = SWITCH(2) LOC(1 2 3 4) 0001
  70.      CHOICE = "72@640X480/800X600/1024X768"
  71.        FREE
  72.        INIT = SWITCH(2) LOC(1 2 3 4) 0000
  73.  
  74. FUNCTION = "Board Memory"
  75.      CHOICE = "2MEG"
  76.        FREE
  77.        INIT = SWITCH(1) LOC(1 2 3 4) 0100
  78.      CHOICE = "4MEG"
  79.        FREE
  80.        INIT = SWITCH(1) LOC(1 2 3 4) 0000
  81.  
  82. FUNCTION = "ZERO WAIT STATE"
  83.      CHOICE = "Disabled"
  84.        DISABLE = YES
  85.        FREE
  86.        INIT = SWITCH(1) LOC(5) 1
  87.      CHOICE = "Enable"
  88.        FREE