  4.  
  5.  
  6.  
  7. Network Working Group                                         B. Stewart Request for Comments: 1659                                  Xyplex, Inc. Obsoletes: 1317                                                July 1994 Category: Standards Track 
  8.  
  9.      Definitions of Managed Objects for RS-232-like Hardware Devices                               using SMIv2 
  10.  
  11. Status of this Memo 
  12.  
  13.    This document specifies an Internet standards track protocol for the    Internet community, and requests discussion and suggestions for    improvements.  Please refer to the current edition of the "Internet    Official Protocol Standards" (STD 1) for the standardization state    and status of this protocol.  Distribution of this memo is unlimited. 
  14.  
  15. Table of Contents 
  16.  
  17.    1. Introduction ................................................    1    2. The SNMPv2 Network Management Framework .....................    1    2.1 Object Definitions .........................................    2    3. Overview ....................................................    2    3.1 Relationship to Interface MIB ..............................    3    4. Definitions .................................................    3    5. Acknowledgements ............................................   20    6. References ..................................................   20    7. Security Considerations .....................................   21    8. Author's Address ............................................   21 
  18.  
  19. 1.  Introduction 
  20.  
  21.    This memo defines an extension to the Management Information Base    (MIB) for use with network management protocols in the Internet    community.  In particular, it defines objects for the management of    RS-232-like devices. 
  22.  
  23. 2.  The SNMPv2 Network Management Framework 
  24.  
  25.    The SNMPv2 Network Management Framework consists of four major    components.  They are: 
  26.  
  27.       o    RFC 1442 [1] which defines the SMI, the mechanisms used for            describing and naming objects for the purpose of management. 
  28.  
  29.       o    STD 17, RFC 1213 [2] defines MIB-II, the core set of managed            objects for the Internet suite of protocols. 
  30.  
  31.  
  32.  
  33.  Stewart                                                         [Page 1] 
  34.  RFC 1659                    RS-232-like MIB                    July 1994 
  35.  
  36.        o    RFC 1445 [3] which defines the administrative and other            architectural aspects of the framework. 
  37.  
  38.       o    RFC 1448 [4] which defines the protocol used for network            access to managed objects. 
  39.  
  40.    The Framework permits new objects to be defined for the purpose of    experimentation and evaluation. 
  41.  
  42. 2.1.  Object Definitions 
  43.  
  44.    Managed objects are accessed via a virtual information store, termed    the Management Information Base or MIB.  Objects in the MIB are    defined using the subset of Abstract Syntax Notation One (ASN.1)    defined in the SMI.  In particular, each object object type is named    by an OBJECT IDENTIFIER, an administratively assigned name.  The    object type together with an object instance serves to uniquely    identify a specific instantiation of the object.  For human    convenience, we often use a textual string, termed the descriptor, to    refer to the object type. 
  45.  
  46. 3.  Overview 
  47.  
  48.    The RS-232-like Hardware Device MIB applies to interface ports that    might logically support the Interface MIB, a Transmission MIB, or the    Character MIB.  The most common example is an RS-232 port with modem    signals. 
  49.  
  50.    The RS-232-like Hardware Device MIB is mandatory for all systems that    have such a hardware port supporting services managed through some    other MIB. 
  51.  
  52.    The MIB includes multiple similar types of hardware, and as a result    contains objects not applicable to all of those types.  The    compliance definitions herein thus have a general group for all    implementations, and separate groups for the different types of    ports, such as asynchronous and synchronous. 
  53.  
  54.    The RS-232-like Hardware Port MIB includes RS-232, RS-422, RS-423,    V.35, and other asynchronous or synchronous, serial physical links    with a similar set of control signals. 
  55.  
  56.    The MIB contains objects that relate to physical layer connections.    Such connections may provide interesting hardware signals (other than    for basic data transfer), such as RNG and DCD.  Hardware ports also    have such attributes as speed and bits per character. 
  57.  
  58.  
  59.  
  60.  
  61.  
  62. Stewart                                                         [Page 2] 
  63.  RFC 1659                    RS-232-like MIB                    July 1994 
  64.  
  65.     The MIB comprises one base object and four tables, detailed in the    following sections.  The tables contain objects for all ports,    asynchronous ports, and input and output control signals. 
  66.  
  67. 3.1.  Relationship to Interface MIB 
  68.  
  69.    The RS-232-like MIB is one of many MIBs designed for layered use as    described in the Interface MIB [5].  In most implementations where it    is present, it will be in the lowest interface sublayer, that is, the    RS-232-like MIB represents the physical layer, providing service to    higher layers such as the Character MIB [6] or PPP MIB [7]. 
  70.  
  71.    The Interface MIB's ifTestTable and ifRcvAddressTable are not    relevant to the RS-232-like MIB. 
  72.  
  73.    The RS-232-like MIB is relevant for ifType values rs232(33), v35(45),    and perhaps others. 
  74.  
  75.    The RS-232-like MIB requires the conformance groups ifGeneralGroup,    and ifFixedLengthGroup. 
  76.  
  77.    The value of ifSpeed is the same as rs232PortOutSpeed. 
  78.  
  79.    Usefulness of error counters in this MIB depends on the octet    counters in ifFixedLengthGroup. 
  80.  
  81. 4.  Definitions 
  82.  
  83.    RS-232-MIB DEFINITIONS ::= BEGIN 
  84.  
  85.    IMPORTS        MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,        Counter32, Integer32            FROM SNMPv2-SMI        InterfaceIndex            FROM IF-MIB        transmission            FROM RFC1213-MIB        MODULE-COMPLIANCE, OBJECT-GROUP            FROM SNMPv2-CONF; 
  86.  
  87.     rs232 MODULE-IDENTITY        LAST-UPDATED "9405261700Z"        ORGANIZATION "IETF Character MIB Working Group"        CONTACT-INFO                "        Bob Stewart                 Postal: Xyplex, Inc. 
  88.  
  89.  
  90.  
  91. Stewart                                                         [Page 3] 
  92.  RFC 1659                    RS-232-like MIB                    July 1994 
  93.  
  94.                          295 Foster Street                         Littleton, MA 01460 
  95.  
  96.                    Tel: 508-952-4816                    Fax: 508-952-4887                 E-mail: rlstewart@eng.xyplex.com"        DESCRIPTION                "The MIB module for RS-232-like hardware devices."        ::= { transmission 33 } 
  97.  
  98.     -- Generic RS-232-like information 
  99.  
  100.    rs232Number OBJECT-TYPE        SYNTAX Integer32        MAX-ACCESS read-only        STATUS current        DESCRIPTION            "The number of ports (regardless of their current            state) in the RS-232-like general port table."        ::= { rs232 1 } 
  101.  
  102.     -- RS-232-like General Port Table 
  103.  
  104.    rs232PortTable OBJECT-TYPE        SYNTAX SEQUENCE OF Rs232PortEntry        MAX-ACCESS not-accessible        STATUS current        DESCRIPTION            "A list of port entries.  The number of entries is            given by the value of rs232Number."        ::= { rs232 2 } 
  105.  
  106.    rs232PortEntry OBJECT-TYPE        SYNTAX Rs232PortEntry        MAX-ACCESS not-accessible        STATUS current        DESCRIPTION            "Status and parameter values for a port."        INDEX { rs232PortIndex }        ::= { rs232PortTable 1 } 
  107.  
  108.    Rs232PortEntry ::=        SEQUENCE {            rs232PortIndex                InterfaceIndex,            rs232PortType 
  109.  
  110.  
  111.  
  112. Stewart                                                         [Page 4] 
  113.  RFC 1659                    RS-232-like MIB                    July 1994 
  114.  
  115.                 INTEGER,            rs232PortInSigNumber                Integer32,            rs232PortOutSigNumber                Integer32,            rs232PortInSpeed                Integer32,            rs232PortOutSpeed                Integer32,            rs232PortInFlowType                INTEGER,            rs232PortOutFlowType                INTEGER        } 
  116.  
  117.    rs232PortIndex OBJECT-TYPE        SYNTAX InterfaceIndex        MAX-ACCESS read-only        STATUS current        DESCRIPTION            "The value of ifIndex for the port.  By convention            and if possible, hardware port numbers map directly            to external connectors.  The value for each port must            remain constant at least from one re-initialization            of the network management agent to the next."        ::= { rs232PortEntry 1 } 
  118.  
  119.    rs232PortType OBJECT-TYPE        SYNTAX INTEGER { other(1), rs232(2), rs422(3),                         rs423(4), v35(5), x21(6) }        MAX-ACCESS read-only        STATUS current        DESCRIPTION            "The port's hardware type."        ::= { rs232PortEntry 2 } 
  120.  
  121.    rs232PortInSigNumber OBJECT-TYPE        SYNTAX Integer32        MAX-ACCESS read-only        STATUS current        DESCRIPTION            "The number of input signals for the port in the            input signal table (rs232PortInSigTable).  The table            contains entries only for those signals the software            can detect and that are useful to observe."        ::= { rs232PortEntry 3 } 
  122.  
  123.  
  124.  
  125.  
  126.  
  127. Stewart                                                         [Page 5] 
  128.  RFC 1659                    RS-232-like MIB                    July 1994 
  129.  
  130.     rs232PortOutSigNumber OBJECT-TYPE        SYNTAX Integer32        MAX-ACCESS read-only        STATUS current        DESCRIPTION            "The number of output signals for the port in the            output signal table (rs232PortOutSigTable).  The            table contains entries only for those signals the            software can assert and that are useful to observe."        ::= { rs232PortEntry 4 } 
  131.  
  132.    rs232PortInSpeed OBJECT-TYPE        SYNTAX Integer32        MAX-ACCESS read-write        STATUS current        DESCRIPTION            "The port's input speed in bits per second.  Note that            non-standard values, such as 9612, are probably not allowed            on most implementations."        ::= { rs232PortEntry 5 } 
  133.  
  134.    rs232PortOutSpeed OBJECT-TYPE        SYNTAX Integer32        MAX-ACCESS read-write        STATUS current        DESCRIPTION            "The port's output speed in bits per second.  Note that            non-standard values, such as 9612, are probably not allowed            on most implementations."        ::= { rs232PortEntry 6 } 
  135.  
  136.    rs232PortInFlowType OBJECT-TYPE        SYNTAX INTEGER { none(1), ctsRts(2), dsrDtr(3) }        MAX-ACCESS read-write        STATUS current        DESCRIPTION            "The port's type of input flow control.  'none'            indicates no flow control at this level.            'ctsRts' and 'dsrDtr' indicate use of the indicated            hardware signals."        ::= { rs232PortEntry 7 } 
  137.  
  138.    rs232PortOutFlowType OBJECT-TYPE        SYNTAX INTEGER { none(1), ctsRts(2), dsrDtr(3) }        MAX-ACCESS read-write        STATUS current        DESCRIPTION            "The port's type of output flow control.  'none' 
  139.  
  140.  
  141.  
  142. Stewart                                                         [Page 6] 
  143.  RFC 1659                    RS-232-like MIB                    July 1994 
  144.  
  145.             indicates no flow control at this level.            'ctsRts' and 'dsrDtr' indicate use of the indicated            hardware signals."        ::= { rs232PortEntry 8 } 
  146.  
  147.     -- RS-232-like Asynchronous Port Table 
  148.  
  149.    rs232AsyncPortTable OBJECT-TYPE        SYNTAX SEQUENCE OF Rs232AsyncPortEntry        MAX-ACCESS not-accessible        STATUS current        DESCRIPTION            "A list of asynchronous port entries.  Entries need            not exist for synchronous ports."        ::= { rs232 3 } 
  150.  
  151.    rs232AsyncPortEntry OBJECT-TYPE        SYNTAX Rs232AsyncPortEntry        MAX-ACCESS not-accessible        STATUS current        DESCRIPTION            "Status and parameter values for an asynchronous            port."        INDEX { rs232AsyncPortIndex }        ::= { rs232AsyncPortTable 1 } 
  152.  
  153.    Rs232AsyncPortEntry ::=        SEQUENCE {            rs232AsyncPortIndex                InterfaceIndex,            rs232AsyncPortBits                INTEGER,            rs232AsyncPortStopBits                INTEGER,            rs232AsyncPortParity                INTEGER,            rs232AsyncPortAutobaud                INTEGER,            rs232AsyncPortParityErrs                Counter32,            rs232AsyncPortFramingErrs                Counter32,            rs232AsyncPortOverrunErrs                Counter32 
  154.  
  155.        } 
  156.  
  157.  
  158.  
  159.  Stewart                                                         [Page 7] 
  160.  RFC 1659                    RS-232-like MIB                    July 1994 
  161.  
  162.     rs232AsyncPortIndex OBJECT-TYPE        SYNTAX InterfaceIndex        MAX-ACCESS read-only        STATUS current        DESCRIPTION            "A unique value for each port.  Its value is the            same as rs232PortIndex for the port."        ::= { rs232AsyncPortEntry 1 } 
  163.  
  164.    rs232AsyncPortBits OBJECT-TYPE        SYNTAX INTEGER (5..8)        MAX-ACCESS read-write        STATUS current        DESCRIPTION            "The port's number of bits in a character."        ::= { rs232AsyncPortEntry 2 } 
  165.  
  166.    rs232AsyncPortStopBits OBJECT-TYPE        SYNTAX INTEGER { one(1), two(2),                         oneAndHalf(3), dynamic(4) }        MAX-ACCESS read-write        STATUS current        DESCRIPTION            "The port's number of stop bits."        ::= { rs232AsyncPortEntry 3 } 
  167.  
  168.    rs232AsyncPortParity OBJECT-TYPE        SYNTAX INTEGER { none(1), odd(2), even(3),                         mark(4), space(5) }        MAX-ACCESS read-write        STATUS current        DESCRIPTION            "The port's sense of a character parity bit."        ::= { rs232AsyncPortEntry 4 } 
  169.  
  170.    rs232AsyncPortAutobaud OBJECT-TYPE        SYNTAX INTEGER { enabled(1), disabled(2) }        MAX-ACCESS read-write        STATUS current        DESCRIPTION            "A control for the port's ability to automatically            sense input speed. 
  171.  
  172.            When rs232PortAutoBaud is 'enabled', a port may            autobaud to values different from the set values for            speed, parity, and character size.  As a result a            network management system may temporarily observe            values different from what was previously set." 
  173.  
  174.  
  175.  
  176. Stewart                                                         [Page 8] 
  177.  RFC 1659                    RS-232-like MIB                    July 1994 
  178.  
  179.         ::= { rs232AsyncPortEntry 5 } 
  180.  
  181.    rs232AsyncPortParityErrs OBJECT-TYPE        SYNTAX Counter32        MAX-ACCESS read-only        STATUS current        DESCRIPTION            "Total number of characters with a parity error,            input from the port since system re-initialization            and while the port state was 'up' or 'test'."        ::= { rs232AsyncPortEntry 6 } 
  182.  
  183.    rs232AsyncPortFramingErrs OBJECT-TYPE        SYNTAX Counter32        MAX-ACCESS read-only        STATUS current        DESCRIPTION            "Total number of characters with a framing error,            input from the port since system re-initialization            and while the port state was 'up' or 'test'."        ::= { rs232AsyncPortEntry 7 } 
  184.  
  185.    rs232AsyncPortOverrunErrs OBJECT-TYPE        SYNTAX Counter32        MAX-ACCESS read-only        STATUS current        DESCRIPTION            "Total number of characters with an overrun error,            input from the port since system re-initialization            and while the port state was 'up' or 'test'."        ::= { rs232AsyncPortEntry 8 } 
  186.  
  187.     -- RS-232-like Synchronous Port Table 
  188.  
  189.    rs232SyncPortTable OBJECT-TYPE        SYNTAX SEQUENCE OF Rs232SyncPortEntry        MAX-ACCESS not-accessible        STATUS current        DESCRIPTION            "A list of asynchronous port entries.  Entries need            not exist for synchronous ports."        ::= { rs232 4 } 
  190.  
  191.    rs232SyncPortEntry OBJECT-TYPE        SYNTAX Rs232SyncPortEntry        MAX-ACCESS not-accessible        STATUS current 
  192.  
  193.  
  194.  
  195. Stewart                                                         [Page 9] 
  196.  RFC 1659                    RS-232-like MIB                    July 1994 
  197.  
  198.         DESCRIPTION            "Status and parameter values for a synchronous            port."        INDEX { rs232SyncPortIndex }        ::= { rs232SyncPortTable 1 } 
  199.  
  200.    Rs232SyncPortEntry ::=        SEQUENCE {            rs232SyncPortIndex                InterfaceIndex,            rs232SyncPortClockSource                INTEGER,            rs232SyncPortFrameCheckErrs                Counter32,            rs232SyncPortTransmitUnderrunErrs                Counter32,            rs232SyncPortReceiveOverrunErrs                Counter32,            rs232SyncPortInterruptedFrames                Counter32,            rs232SyncPortAbortedFrames                Counter32,            rs232SyncPortRole                INTEGER,            rs232SyncPortEncoding                INTEGER,            rs232SyncPortRTSControl                INTEGER,            rs232SyncPortRTSCTSDelay                Integer32,            rs232SyncPortMode                INTEGER,            rs232SyncPortIdlePattern                INTEGER,            rs232SyncPortMinFlags                Integer32        } 
  201.  
  202.    rs232SyncPortIndex OBJECT-TYPE        SYNTAX InterfaceIndex        MAX-ACCESS read-only        STATUS current        DESCRIPTION            "A unique value for each port.  Its value is the            same as rs232PortIndex for the port."        ::= { rs232SyncPortEntry 1 } 
  203.  
  204.  
  205.  
  206.  
  207.  
  208. Stewart                                                        [Page 10] 
  209.  RFC 1659                    RS-232-like MIB                    July 1994 
  210.  
  211.     rs232SyncPortClockSource OBJECT-TYPE        SYNTAX INTEGER { internal(1), external(2), split(3) }        MAX-ACCESS read-write        STATUS current        DESCRIPTION            "Source of the port's bit rate clock. 'split' means            the tranmit clock is internal and the receive clock            is external."        ::= { rs232SyncPortEntry 2 } 
  212.  
  213.    rs232SyncPortFrameCheckErrs OBJECT-TYPE        SYNTAX Counter32        MAX-ACCESS read-only        STATUS current        DESCRIPTION            "Total number of frames with an invalid frame check            sequence, input from the port since system            re-initialization and while the port state was 'up'            or 'test'."        ::= { rs232SyncPortEntry 3 } 
  214.  
  215.    rs232SyncPortTransmitUnderrunErrs OBJECT-TYPE        SYNTAX Counter32        MAX-ACCESS read-only        STATUS current        DESCRIPTION            "Total number of frames that failed to be            transmitted on the port since system            re-initialization and while the port state was 'up'            or 'test' because data was not available to the            transmitter in time."        ::= { rs232SyncPortEntry 4 } 
  216.  
  217.    rs232SyncPortReceiveOverrunErrs OBJECT-TYPE        SYNTAX Counter32        MAX-ACCESS read-only        STATUS current        DESCRIPTION            "Total number of frames that failed to be received            on the port since system re-initialization and while            the port state was 'up' or 'test' because the            receiver did not accept the data in time."        ::= { rs232SyncPortEntry 5 } 
  218.  
  219.    rs232SyncPortInterruptedFrames OBJECT-TYPE        SYNTAX Counter32        MAX-ACCESS read-only        STATUS current 
  220.  
  221.  
  222.  
  223. Stewart                                                        [Page 11] 
  224.  RFC 1659                    RS-232-like MIB                    July 1994 
  225.  
  226.         DESCRIPTION            "Total number of frames that failed to be received            or transmitted on the port due to loss of modem            signals since system re-initialization and while the            port state was 'up' or 'test'."        ::= { rs232SyncPortEntry 6 } 
  227.  
  228.    rs232SyncPortAbortedFrames OBJECT-TYPE        SYNTAX Counter32        MAX-ACCESS read-only        STATUS current        DESCRIPTION            "Number of frames aborted on the port due to            receiving an abort sequence since system            re-initialization and while the port state was 'up'            or 'test'."        ::= { rs232SyncPortEntry 7 } 
  229.  
  230.    rs232SyncPortRole OBJECT-TYPE        SYNTAX INTEGER  { dte(1), dce(2) }        MAX-ACCESS read-write        STATUS current        DESCRIPTION            "The role the device is playing that is using this port.               dte    means the device is performing the role of                      data terminal equipment               dce    means the device is performing the role of                      data circuit-terminating equipment."        DEFVAL { dce }        ::= { rs232SyncPortEntry 8 } 
  231.  
  232.    rs232SyncPortEncoding OBJECT-TYPE        SYNTAX INTEGER  { nrz(1), nrzi(2) }        MAX-ACCESS read-write        STATUS current        DESCRIPTION            "The bit stream encoding technique that is in effect             for this port.               nrz    for Non-Return to Zero encoding               nrzi   for Non-Return to Zero Inverted encoding."        DEFVAL { nrz }        ::= { rs232SyncPortEntry 9 } 
  233.  
  234.    rs232SyncPortRTSControl OBJECT-TYPE        SYNTAX INTEGER  { controlled(1), constant(2) }        MAX-ACCESS read-write        STATUS current        DESCRIPTION 
  235.  
  236.  
  237.  
  238. Stewart                                                        [Page 12] 
  239.  RFC 1659                    RS-232-like MIB                    July 1994 
  240.  
  241.             "The method used to control the Request To Send (RTS)             signal. 
  242.  
  243.               controlled  when the DTE is asserts RTS each time                           data needs to be transmitted and drops                           RTS at some point after data                           transmission begins. 
  244.  
  245.                           If rs232SyncPortRole is 'dte', the                           RTS is an output signal. The device                           will issue a RTS and wait for a CTS                           from the DCE before starting to                           transmit. 
  246.  
  247.                           If rs232SyncPortRole is 'dce', the                           RTS is an input signal. The device                           will issue a CTS only after having                           received RTS and waiting the                           rs232SyncPortRTSCTSDelay interval. 
  248.  
  249.               constant    when the DTE constantly asserts RTS."        DEFVAL { constant }        ::= { rs232SyncPortEntry 10 } 
  250.  
  251.    rs232SyncPortRTSCTSDelay OBJECT-TYPE        SYNTAX Integer32        MAX-ACCESS read-write        STATUS current        DESCRIPTION            "The interval (in milliseconds) that the DCE must wait             after it sees RTS asserted before asserting CTS.  This             object exists in support of older synchronous devices             that cannot recognize CTS within a certain interval             after it asserts RTS."        DEFVAL { 0 }        ::= { rs232SyncPortEntry 11 } 
  252.  
  253.    rs232SyncPortMode OBJECT-TYPE        SYNTAX INTEGER  { fdx(1), hdx(2), simplex-receive(3),                          simplex-send(4) }        MAX-ACCESS read-write        STATUS current        DESCRIPTION            "The mode of operation of the port with respect to the             direction and simultaneity of data transfer. 
  254.  
  255.  
  256.  
  257.  
  258.  
  259.  Stewart                                                        [Page 13] 
  260.  RFC 1659                    RS-232-like MIB                    July 1994 
  261.  
  262.                fdx              when frames on the data link can be                                transmitted and received at the same                                time 
  263.  
  264.               hdx              when frames can either be received                                from the data link or transmitted                                onto the data link but not at the                                same time. 
  265.  
  266.               simplex-receive  when frames can only be received on                                this data link. 
  267.  
  268.               simplex-send     when frames can only be sent on this                                data link."        DEFVAL { fdx }        ::= { rs232SyncPortEntry 12 } 
  269.  
  270.    rs232SyncPortIdlePattern OBJECT-TYPE        SYNTAX INTEGER  { mark(1), space(2) }        MAX-ACCESS read-write        STATUS current        DESCRIPTION            "The bit pattern used to indicate an idle line."        DEFVAL { space }        ::= { rs232SyncPortEntry 13 } 
  271.  
  272.    rs232SyncPortMinFlags OBJECT-TYPE        SYNTAX Integer32        MAX-ACCESS read-write        STATUS current        DESCRIPTION            "The minimum number of flag patterns this port needs in             order to recognize the end of one frame and the start             of the next.  Plausible values are 1 and 2."        DEFVAL { 2 }        ::= { rs232SyncPortEntry 14 } 
  273.  
  274.     -- Input Signal Table 
  275.  
  276.    rs232InSigTable OBJECT-TYPE        SYNTAX SEQUENCE OF Rs232InSigEntry        MAX-ACCESS not-accessible        STATUS current        DESCRIPTION            "A list of port input control signal entries            implemented and visible to the software on the port,            and useful to monitor." 
  277.  
  278.  
  279.  
  280. Stewart                                                        [Page 14] 
  281.  RFC 1659                    RS-232-like MIB                    July 1994 
  282.  
  283.         ::= { rs232 5 } 
  284.  
  285.    rs232InSigEntry OBJECT-TYPE        SYNTAX Rs232InSigEntry        MAX-ACCESS not-accessible        STATUS current        DESCRIPTION            "Input control signal status for a hardware port."        INDEX { rs232InSigPortIndex, rs232InSigName }        ::= { rs232InSigTable 1 } 
  286.  
  287.    Rs232InSigEntry ::=        SEQUENCE {            rs232InSigPortIndex                InterfaceIndex,            rs232InSigName                INTEGER,            rs232InSigState                INTEGER,            rs232InSigChanges                Counter32        } 
  288.  
  289.    rs232InSigPortIndex OBJECT-TYPE        SYNTAX InterfaceIndex        MAX-ACCESS read-only        STATUS current        DESCRIPTION            "The value of rs232PortIndex for the port to which            this entry belongs."        ::= { rs232InSigEntry 1 } 
  290.  
  291.    rs232InSigName OBJECT-TYPE        SYNTAX INTEGER { rts(1), cts(2), dsr(3), dtr(4), ri(5),                         dcd(6), sq(7), srs(8), srts(9),                         scts(10), sdcd(11) }        MAX-ACCESS read-only        STATUS current        DESCRIPTION            "Identification of a hardware signal, as follows: 
  292.  
  293.                rts    Request to Send                cts    Clear to Send                dsr    Data Set Ready                dtr    Data Terminal Ready                ri     Ring Indicator                dcd    Received Line Signal Detector                sq     Signal Quality Detector 
  294.  
  295.  
  296.  
  297. Stewart                                                        [Page 15] 
  298.  RFC 1659                    RS-232-like MIB                    July 1994 
  299.  
  300.                 srs    Data Signaling Rate Selector                srts   Secondary Request to Send                scts   Secondary Clear to Send                sdcd   Secondary Received Line Signal Detector            "        REFERENCE            "EIA Standard RS-232-C, August 1969."        ::= { rs232InSigEntry 2 } 
  301.  
  302.    rs232InSigState OBJECT-TYPE        SYNTAX INTEGER { none(1), on(2), off(3) }        MAX-ACCESS read-only        STATUS current        DESCRIPTION            "The current signal state."        ::= { rs232InSigEntry 3 } 
  303.  
  304.    rs232InSigChanges OBJECT-TYPE        SYNTAX Counter32        MAX-ACCESS read-only        STATUS current        DESCRIPTION            "The number of times the signal has changed from            'on' to 'off' or from 'off' to 'on'."        ::= { rs232InSigEntry 4 } 
  305.  
  306.     -- Output Signal Table 
  307.  
  308.    rs232OutSigTable OBJECT-TYPE        SYNTAX SEQUENCE OF Rs232OutSigEntry        MAX-ACCESS not-accessible        STATUS current        DESCRIPTION            "A list of port output control signal entries            implemented and visible to the software on the port,            and useful to monitor."        ::= { rs232 6 } 
  309.  
  310.    rs232OutSigEntry OBJECT-TYPE        SYNTAX Rs232OutSigEntry        MAX-ACCESS not-accessible        STATUS current        DESCRIPTION            "Output control signal status for a hardware port."        INDEX { rs232OutSigPortIndex, rs232OutSigName }        ::= { rs232OutSigTable 1 } 
  311.  
  312.  
  313.  
  314.  Stewart                                                        [Page 16] 
  315.  RFC 1659                    RS-232-like MIB                    July 1994 
  316.  
  317.     Rs232OutSigEntry ::=        SEQUENCE {            rs232OutSigPortIndex                InterfaceIndex,            rs232OutSigName                INTEGER,            rs232OutSigState                INTEGER,            rs232OutSigChanges                Counter32        } 
  318.  
  319.    rs232OutSigPortIndex OBJECT-TYPE        SYNTAX InterfaceIndex        MAX-ACCESS read-only        STATUS current        DESCRIPTION            "The value of rs232PortIndex for the port to which            this entry belongs."        ::= { rs232OutSigEntry 1 } 
  320.  
  321.    rs232OutSigName OBJECT-TYPE        SYNTAX INTEGER { rts(1), cts(2), dsr(3), dtr(4), ri(5),                         dcd(6), sq(7), srs(8), srts(9),                         scts(10), sdcd(11) }        MAX-ACCESS read-only        STATUS current        DESCRIPTION            "Identification of a hardware signal, as follows: 
  322.  
  323.                rts    Request to Send                cts    Clear to Send                dsr    Data Set Ready                dtr    Data Terminal Ready                ri     Ring Indicator                dcd    Received Line Signal Detector                sq     Signal Quality Detector                srs    Data Signaling Rate Selector                srts   Secondary Request to Send                scts   Secondary Clear to Send                sdcd   Secondary Received Line Signal Detector            "        REFERENCE            "EIA Standard RS-232-C, August 1969."        ::= { rs232OutSigEntry 2 } 
  324.  
  325.    rs232OutSigState OBJECT-TYPE        SYNTAX INTEGER { none(1), on(2), off(3) } 
  326.  
  327.  
  328.  
  329. Stewart                                                        [Page 17] 
  330.  RFC 1659                    RS-232-like MIB                    July 1994 
  331.  
  332.         MAX-ACCESS read-only        STATUS current        DESCRIPTION            "The current signal state."        ::= { rs232OutSigEntry 3 } 
  333.  
  334.    rs232OutSigChanges OBJECT-TYPE        SYNTAX Counter32        MAX-ACCESS read-only        STATUS current        DESCRIPTION            "The number of times the signal has changed from            'on' to 'off' or from 'off' to 'on'."        ::= { rs232OutSigEntry 4 } 
  335.  
  336.     -- conformance information 
  337.  
  338.    rs232Conformance OBJECT IDENTIFIER ::= { rs232 7 } 
  339.  
  340.    rs232Groups      OBJECT IDENTIFIER ::= { rs232Conformance 1 }    rs232Compliances OBJECT IDENTIFIER ::= { rs232Conformance 2 } 
  341.  
  342.     -- compliance statements 
  343.  
  344.    rs232Compliance MODULE-COMPLIANCE        STATUS  current        DESCRIPTION                "The compliance statement for SNMPv2 entities                which have RS-232-like hardware interfaces." 
  345.  
  346.        MODULE  -- this module            MANDATORY-GROUPS { rs232Group } 
  347.  
  348.            GROUP   rs232AsyncGroup            DESCRIPTION                "The Asynch group is mandatory only for those                 SNMPv2 entities which have asynchronous                 interfaces Rs-232-like." 
  349.  
  350.            GROUP   rs232SyncGroup            DESCRIPTION                "The Synch group is mandatory only for those                 SNMPv2 entities which have synchronous                 interfaces Rs-232-like."        ::= { rs232Compliances 1 } 
  351.  
  352.  
  353.  
  354.  Stewart                                                        [Page 18] 
  355.  RFC 1659                    RS-232-like MIB                    July 1994 
  356.  
  357.     -- units of conformance 
  358.  
  359.    rs232Group    OBJECT-GROUP        OBJECTS { rs232Number, rs232PortIndex, rs232PortType,                  rs232PortInSigNumber, rs232PortOutSigNumber,                  rs232PortInSpeed, rs232PortOutSpeed,                  rs232PortInFlowType, rs232PortOutFlowType,                  rs232InSigPortIndex, rs232InSigName,                  rs232InSigState, rs232InSigChanges,                  rs232OutSigPortIndex, rs232OutSigName,                  rs232OutSigState, rs232OutSigChanges }        STATUS  current        DESCRIPTION                "A collection of objects providing information                 applicable to all RS-232-like interfaces."        ::= { rs232Groups 1 } 
  360.  
  361.    rs232AsyncGroup OBJECT-GROUP        OBJECTS { rs232AsyncPortIndex, rs232AsyncPortBits,                  rs232AsyncPortStopBits, rs232AsyncPortParity,                  rs232AsyncPortAutobaud, rs232AsyncPortParityErrs,                  rs232AsyncPortFramingErrs, rs232AsyncPortOverrunErrs }        STATUS  current        DESCRIPTION                "A collection of objects providing information                 applicable to asynchronous RS-232-like interfaces."        ::= { rs232Groups 2 } 
  362.  
  363.    rs232SyncGroup OBJECT-GROUP        OBJECTS { rs232SyncPortIndex, rs232SyncPortClockSource,                  rs232SyncPortFrameCheckErrs,                  rs232SyncPortTransmitUnderrunErrs,                  rs232SyncPortReceiveOverrunErrs,                  rs232SyncPortInterruptedFrames,                  rs232SyncPortAbortedFrames }        STATUS  current        DESCRIPTION                "A collection of objects providing information                 applicable to synchronous RS-232-like interfaces."        ::= { rs232Groups 3 } 
  364.  
  365.    rs232SyncSDLCGroup OBJECT-GROUP        OBJECTS { rs232SyncPortRole,                  rs232SyncPortEncoding,                  rs232SyncPortRTSControl,                  rs232SyncPortRTSCTSDelay,                  rs232SyncPortMode,                  rs232SyncPortIdlePattern, 
  366.  
  367.  
  368.  
  369. Stewart                                                        [Page 19] 
  370.  RFC 1659                    RS-232-like MIB                    July 1994 
  371.  
  372.                   rs232SyncPortMinFlags }        STATUS  current        DESCRIPTION                "A collection of objects providing information                 applicable to synchronous RS-232-like interfaces                 running SDLC."        ::= { rs232Groups 4 } 
  373.  
  374.    END 
  375.  
  376. 5.  Acknowledgements 
  377.  
  378.    This memo was produced by the IETF Character MIB Working Group. 
  379.  
  380. 6.  References 
  381.  
  382.    [1] Case, J., McCloghrie, K., Rose, M., and S. Waldbusser, "Structure        of Management Information for version 2 of the Simple Network        Management Protocol (SNMPv2)", RFC 1442, SNMP Research,Inc.,        Hughes LAN Systems, Dover Beach Consulting, Inc., Carnegie Mellon        University, April 1993. 
  383.  
  384.    [2] McCloghrie, K., and M. Rose, Editors, "Management Information        Base for Network Management of TCP/IP-based internets: MIB-II",        STD 17, RFC 1213, Hughes LAN Systems, Performance Systems        International, March 1991. 
  385.  
  386.    [3] Galvin, J., and K. McCloghrie, "Administrative Model for version        2 of the Simple Network Management Protocol (SNMPv2)", RFC 1445,        Trusted Information Systems, Hughes LAN Systems, April 1993. 
  387.  
  388.    [4] Case, J., McCloghrie, K., Rose, M., and S. Waldbusser, "Protocol        Operations for version 2 of the Simple Network Management        Protocol (SNMPv2)", RFC 1448, SNMP Research,Inc., Hughes LAN        Systems, Dover Beach Consulting, Inc., Carnegie Mellon        University, April 1993. 
  389.  
  390.    [5] McCloghrie, K., and F. Kastenholz, "Evolution of the Interfaces        Group of MIB-II", RFC 1573, Hughes LAN Systems, FTP Software,        January 1994. 
  391.  
  392.    [6] Stewart, B., "Definitions of Managed Objects for Character Stream        Devices using SMIv2", RFC 1658, Xyplex, Inc., July 1994. 
  393.  
  394.    [7] Kastenholz, F., "The Definitions of Managed Objects for the Link        Control Protocol of the Point-to-Point Protocol", RFC 1471, FTP        Software, Inc., June 1993. 
  395.  
  396.  
  397.  
  398.  Stewart                                                        [Page 20] 
  399.  RFC 1659                    RS-232-like MIB                    July 1994 
  400.  
  401.  7.  Security Considerations 
  402.  
  403.    Security issues are not discussed in this memo. 
  404.  
  405. 8.  Author's Address 
  406.  
  407.    Bob Stewart    Xyplex, Inc.    295 Foster Street    Littleton, MA 01460 
  408.  
  409.    Phone: 508-952-4816    Fax: 508-952-4887    EMail: rlstewart@eng.xyplex.com 
  410.  
  411.  
  412.  
  413.  
  414.  
  415.  
  416.  
  417.  
  418.  
  419.  
  420.  
  421.  
  422.  
  423.  
  424.  
  425.  
  426.  
  427.  
  428.  
  429.  
  430.  
  431.  
  432.  
  433.  
  434.  
  435.  
  436.  
  437.  
  438.  
  439.  
  440.  
  441.  
  442.  
  443.  
  444.  
  445.  
  446.  
  447. Stewart                                                        [Page 21] 
  448.  
  449.