home *** CD-ROM | disk | FTP | other *** search
/ Handbook of Infosec Terms 2.0 / Handbook_of_Infosec_Terms_Version_2.0_ISSO.iso / text / rfcs / rfc1604.txt < prev    next >
Text File  |  1996-05-07  |  90KB  |  912 lines

  1.  
  2.  
  3.  
  4.  
  5.  
  6.  
  7. Network Working Group                                   T. Brown, Editor Request for Comments: 1604                  Bell Communications Research Obsoletes: 1596                                               March 1994 Category: Standards Track 
  8.  
  9.                       Definitions of Managed Objects                         for Frame Relay Service 
  10.  
  11. Status of this Memo 
  12.  
  13.    This document specifies an Internet standards track protocol for the    Internet community, and requests discussion and suggestions for    improvements.  Please refer to the current edition of the "Internet    Official Protocol Standards" (STD 1) for the standardization state    and status of this protocol.  Distribution of this memo is unlimited. 
  14.  
  15. Abstract 
  16.  
  17.    This memo defines an extension to the Management Information Base    (MIB) for use with network management protocols in TCP/IP-based    internets.  In particular, it defines objects for managing the Frame    Relay Service. 
  18.  
  19. Table of Contents 
  20.  
  21.    1. The SNMPv2 Network Management Framework ...............    2    2. Object Definitions ....................................    2    3. Overview ..............................................    2    3.1 Scope of MIB .........................................    3    3.2 Frame Relay Service MIB Terminology ..................    5    3.3 Apply MIB II to a Frame Relay Service ................    7    4. Object Definitions ....................................   12    4.1 The Frame Relay Service Logical Port Group ...........   12    4.2 The Frame Relay Management VC Signaling Group ........   15    4.3 The PVC End-Point Group ..............................   22    4.4 Frame Relay PVC Connection Group .....................   30    4.5 Frame Relay Accounting Groups ........................   37    5. Frame Relay Network Service TRAPS .....................   40    6. Conformance Information ...............................   43    7. Acknowledgments .......................................   45    8. References ............................................   45    9. Security Considerations ...............................   46    10. Author's Address .....................................   46 
  22.  
  23.  
  24.  
  25.  
  26.  
  27.  
  28.  
  29. Frame Relay Service MIB Working Group                           [Page 1] 
  30.  RFC 1604                Frame Relay Service MIB               March 1994 
  31.  
  32.  1.  The SNMPv2 Network Management Framework 
  33.  
  34.    The SNMPv2 Network Management Framework consists of four major    components.  They are: 
  35.  
  36.       o    RFC 1442 which defines the SMI, the mechanisms used for            describing and naming objects for the purpose of            management. 
  37.  
  38.       o    STD 17, RFC 1213 defines MIB-II, the core set of managed            objects for the Internet suite of protocols. 
  39.  
  40.       o    RFC 1445 which defines the administrative and other            architectural aspects of the framework. 
  41.  
  42.       o    RFC 1448 which defines the protocol used for network            access to managed objects. 
  43.  
  44.    The Framework permits new objects to be defined for the purpose of    experimentation and evaluation. 
  45.  
  46. 2.  Object Definitions 
  47.  
  48.    Managed objects are accessed via a virtual information store, termed    the Management Information Base or MIB.  Objects in the MIB are    defined using the subset of Abstract Syntax Notation One (ASN.1)    defined in the SMI.  In particular, each object object type is named    by an OBJECT IDENTIFIER, an administratively assigned name.  The    object type together with an object instance serves to uniquely    identify a specific instantiation of the object.  For human    convenience, we often use a textual string, termed the descriptor, to    refer to the object type. 
  49.  
  50. 3.  Overview 
  51.  
  52.    These objects are used when the particular media being used to manage    is Frame Relay Service.  At present, this applies to these values of    the ifType variable in the Internet-standard MIB: 
  53.  
  54.           frameRelayService (44) 
  55.  
  56.    This section provides an overview and background of how to use this    MIB and other potential MIBs when managing a Frame Relay Service. 
  57.  
  58.    Figure 1 shows the MIB stack that could be followed for managing a    Frame Relay Service.  This is only an example and not meant to be    inclusive. 
  59.  
  60.  
  61.  
  62.  Frame Relay Service MIB Working Group                           [Page 2] 
  63.  RFC 1604                Frame Relay Service MIB               March 1994 
  64.  
  65.                  ____________________________________________________                 |              |              |       |            |                 |              |              | SIP   |  RFC1490   |                 |              | X.25 MIB     | Relay | (no applic.|                 |              | for IW/Encap.| MIB   |  MIB)      |                 |              |              |       |            |                 |    MIB II    |-----------------------------------|                 |              |                                   |                 |   ifTable    |      Frame Relay Service MIB      |                 |  ifXTable    |                                   |                 | ifStackTable |___________________________________|                 |              |                         |         |                 |              | Physical Layer MIBs     | ATM MIB |                 |              |  e.g., DS1/E1 MIB,      |---------|                 |              |  RS232-like MIB         | Phy.    |                 |              |                         | Layer   |                 |              |                         |  MIB    |                 |--------------|-------------------------|---------| 
  66.  
  67.                       Figure 1. Frame Relay MIB Architecture 
  68.  
  69. 3.1.  Scope of MIB 
  70.  
  71.    The Frame Relay Service MIB will only manage the Frame Relay portion    of the network.  This MIB is based upon the Customer Network    Management concepts presented in the document "Service Management    Architecture for Virtual Connection Services" [6]. 
  72.  
  73.    This MIB will NOT be implemented on User Equipment (e.g., DTE), and    the Frame Relay DTE MIB (RFC 1315) should be used to manage those    devices [8]. 
  74.  
  75.    Frame Relay Service MIB is intended to be used for Customer Network    Management (CNM) of a Frame Relay Network Service.  It provides    information that allows end-customers to obtain performance    monitoring, fault detection, and configuration information about    their Frame Relay Service.  It is an implementation decision as to    whether this MIB is used to create/delete/modify PVCs and to turn    PVCs on or off. 
  76.  
  77.    By using this and other related MIBs, a customer's NMS can monitor    their PVCs and UNI/NNI logical ports.  Internal aspects of the    network (e.g., switching elements, line cards, and network routing    tables) are outside the scope of this MIB.  The Customer's NMS will    typically access the SNMP proxy-agent within the Frame Relay network    using SNMP over UDP over IP with IP encapsulated in Frame Relay    according to RFC1490/ANSI T1.617 Annex F [7,9].  The customer, thus, 
  78.  
  79.  
  80.  
  81. Frame Relay Service MIB Working Group                           [Page 3] 
  82.  RFC 1604                Frame Relay Service MIB               March 1994 
  83.  
  84.     has a PVC to the SNMP proxy-agent.  Alternate access mechanisms and    SNMP agent implementations are possible.  The service capabilities    include retrieving information and receiving TRAPs.  It is beyond the    scope of this MIB to define managed objects to monitor the physical    layer.  Existing physical layer MIBs (e.g., DS1 MIB) and MIB II will    be used as possible.  The Frame Relay Service SNMP MIB for CNM will    not contain any managed objects to monitor the physical layer.  This    MIB primarily addresses Frame Relay PVCs.  This MIB may be extended    at a later time to handle Frame Relay SVCs. 
  85.  
  86.    This MIB is only used to manage a single Frame Relay Service offering    from one network.  This MIB will typically be implemented on a    service provider's SNMP proxy-agent. The SNMP proxy-agent proxies for    all Frame Relay equipment within one service provider's Frame Relay    network.  (Other SNMP agent implementations are not precluded.)    Therefore, this MIB models a PVC segment through one Frame Relay    Network.  See Figure 2.  If the customer's PVCs traverse multiple    networks, then the customer needs to poll multiple network proxy-    agents within each Frame Relay Network to retrieve their end-to-end    view of their service.  See Figure 2 and the Service Management    Architecture [6]. 
  87.  
  88.  
  89.  
  90.  
  91.  
  92.  
  93.  
  94.  
  95.  
  96.  
  97.  
  98.  
  99.  
  100.  
  101.  
  102.  
  103.  
  104.  
  105.  
  106.  
  107.  
  108.  
  109.  
  110.  
  111.  
  112.  
  113.  
  114.  
  115.  
  116.  Frame Relay Service MIB Working Group                           [Page 4] 
  117.  RFC 1604                Frame Relay Service MIB               March 1994 
  118.  
  119.                  +-------------------------------------+                 | Customer Network Management Station |                 |            (SNMP based)             |                 +-------------------------------------+                     ^              ^               ^                     |              |               |                     |              |               |            UNI      |      NNI     |       NNI     |       UNI             |       ^       |      ^        |      ^             | +-----------+ | +-----------+ | +-----------+ |             | |           | | |           | | |           | | Originating | |   FR      | | |   FR      | | |   FR      | |Terminating  +--------+ | | Network I | | | Network J | | | Network K | | +--------+  |        | | |           | | |           | | |           | | |        |  |        |---|           |---|           |---|           |---| User B |  |        | | |           | | |           | | |           | | |        |  |     ////////////////////////////////////////////////////////////    |  |        | | |           | | |           | | |           | | |        |  +--------+ | +-----------+ | +-----------+ | +-----------+ | +--------+             |               |               |               |             |               |               |               |             | PVC Segment 1 | PVC Segment 2 | PVC Segment 3 |             |<------------->|<------------->|<------------->|             |                                               |             |              Multi-network PVC                |             |<--------------------------------------------->|             |  NNI = Network-to Network Interface           |                UNI = User-to-Network Interface 
  120.  
  121.                        Figure 2. Multi-network PVC 
  122.  
  123.    Also, since the Frame Relay network is a shared network amongst many    Frame Relay subscribers, each subscriber will only have access to    their information (e.g., information with respect to their interfaces    and PVCs).  Therefore, in order to provide this capability, the Frame    Relay PVC CNM proxy agent should be able to support instance level    granularity for MIB views.  See the Service Management Architecture. 
  124.  
  125. 3.2.  Frame Relay Service MIB Terminology 
  126.  
  127.    Access Channel - An access channel generically refers to the DS1/E1    or DS3/E3-based UNI access channel or NNI access channel across which    frame relay data transits. An access channel is the access pathway    for a single stream of user data. 
  128.  
  129.    Within a given T1 line, an access channel can denote any one of the    following: 
  130.  
  131.  
  132.  
  133.  Frame Relay Service MIB Working Group                           [Page 5] 
  134.  RFC 1604                Frame Relay Service MIB               March 1994 
  135.  
  136.        o    Unchannelized T1 - the entire T1 line is considered an access            channel. Each access channel is comprised of 24 T1 time            slots. 
  137.  
  138.       o    Channelized T1 - an access channel is any one of 24 channels.            Each access channel is comprised of a single T1 time slot. 
  139.  
  140.       o    Fractional T1 - an access channel is a grouping of N T1 time            slots (NX56/64 Kbps, where N = 1-23 T1 Time slots per FT1            Access Channel) that may be assigned in consecutive or            non-consecutive order. 
  141.  
  142.    Within a given E1 line, a channel can denote any one of the    following: 
  143.  
  144.       o    Unchannelized E1 - the entire E1 line is considered a single            access channel.  Each access channel is comprised of 31 E1            time slots. 
  145.  
  146.       o    Channelized E1 - an access channel is any one of 31 channels.            Each access channel is comprised of a single E1 time slot. 
  147.  
  148.       o    Fractional E1 - an access channel is a grouping of N E1 time            slots (NX64 Kbps, where N = 1-30 E1 time slots per FE1 access            channel) that may be assigned in consecutive or            non-consecutive order. 
  149.  
  150.       in 3 Within a given unformatted line, the entire unformatted line       is considered an access channel. Examples include RS-232, V.35,       V.36 and X.21 (non- switched). 
  151.  
  152.       Access Rate - The data rate of the access channel, expressed in       bits/second.  The speed of the user access channel determines how       rapidly the end user can inject data into the network. 
  153.  
  154.       Bc - The Committed Burst Size (Bc) is the maximum amount of       subscriber data (expressed in bits) that the network agrees to       transfer, under normal conditions, during a time interval Tc. 
  155.  
  156.       Be - The Excess Burst Size (Be) is the maximum amount of       subscriber data (expressed in bits) in excess of Bc that the       network will attempt to deliver during the time interval Tc.  This       data (Be) is delivered in general with a lower probability than       Bc. 
  157.  
  158.       CIR - The Committed Information Rate (CIR) is the subscriber data       rate (expressed in bits/second) that the network commits to       deliver under normal network conditions.  CIR is averaged over the 
  159.  
  160.  
  161.  
  162. Frame Relay Service MIB Working Group                           [Page 6] 
  163.  RFC 1604                Frame Relay Service MIB               March 1994 
  164.  
  165.        time interval Tc (CIR = Bc/Tc). 
  166.  
  167.       DLCI - Data Link Connection Identifier 
  168.  
  169.       Logical Port - This term is used to model the Frame Relay       "interface" on a device. 
  170.  
  171.       NNI - Network to Network Interface 
  172.  
  173.       Permanent Virtual Connection (PVC) - A virtual connection that has       its end-points and bearer capabilities defined at subscription       time. 
  174.  
  175.       Time slot (E1) - An octet within the 256-bit information field in       each E1 frame is defined as a time slot. Time slots are position       sensitive within the 256-bit information field.  Fractional E1       service is provided in contiguous or non- contiguous time slot       increments. 
  176.  
  177.       Time slot (T1) - An octet within the 192-bit information field in       each T1 frame is defined as a time slot. Time slots are position       sensitive within the 192-bit information field.  Fractional T1       service is provided in contiguous or non- contiguous time slot       increments. 
  178.  
  179.       UNI - User to Network Interface 
  180.  
  181.       N391 - Full status (status of all PVCs) polling counter 
  182.  
  183.       N392 - Error threshold 
  184.  
  185.       N393 - Monitored events count 
  186.  
  187.       T391 - Link integrity verification polling timer 
  188.  
  189.       T392 - Polling verification timer 
  190.  
  191.       nT3 - Status enquiry timer 
  192.  
  193.       nN3 - Maximum status enquiry counter 
  194.  
  195. 3.3.  Apply MIB II to a Frame Relay Service 
  196.  
  197.       Use the System Group to apply to the SNMP proxy-agent, since the       proxy-agent may be monitoring many Frame Relay devices in one       network.  System Group applies to only one system.  This group is       not instantiated. 
  198.  
  199.  
  200.  
  201.  Frame Relay Service MIB Working Group                           [Page 7] 
  202.  RFC 1604                Frame Relay Service MIB               March 1994 
  203.  
  204.            sysDescr:  ASCII string describing the SNMP proxy-agent.                      Can be up to 255 characters long. This field is                      generally used to indicate the network providers                      identification and type of service offered. 
  205.  
  206.           sysObjectID:  Unique OBJECT IDENTIFIER (OID) for the SNMP                         proxy-agent. 
  207.  
  208.           sysUpTime:  Clock in the SNMP proxy-agent; TimeTicks                       in 1/100s of a second.  Elapsed type since                       the proxy-agent came on line. 
  209.  
  210.           sysContact:  Contact for the SNMP proxy-agent.                        ASCII string of up to 255 characters. 
  211.  
  212.           sysName:  Domain name of the SNMP proxy-agent, for example,                     acme.com 
  213.  
  214.           sysLocation:  Location of the SNMP proxy-agent.                         ASCII string of up to 255 characters. 
  215.  
  216.           sysServices:  Services of the managed device.  The value "2",                         which implies that                         the Frame Relay network is providing                         a subnetwork level service, is recommended. 
  217.  
  218.    This specifies how the Interfaces Group defined in MIB II shall be    used for the management of Frame Relay based interfaces, and in    conjunction with the Frame Relay Service MIB module. This memo    assumes the interpretation of the evolution of the Interfaces group    to be in accordance with: "The interfaces table (ifTable) contains    information on the managed resource's interfaces.  Each sub-layer    below the internetwork layer of a network interface is considered an    interface." Thus, the ifTable allows the following Frame Relay-based    interfaces to be represented as table entries: 
  219.  
  220.           - Frame Relay interfaces in the Frame Relay equipment (e.g.,             switches, routers or networks) with Frame Relay interfaces.             This level is concerned with generic frame counts and             not with individual virtual connections. 
  221.  
  222.    In accordance with the guidelines of ifTable, frame counts per    virtual connection are not covered by ifTable, and are considered    interface specific and covered in the Frame Relay Service MIB module.    In order to interrelate the ifEntries properly, the Interfaces Stack    Group shall be supported. 
  223.  
  224.    Some specific interpretations of ifTable for Frame Relay follow. 
  225.  
  226.  
  227.  
  228. Frame Relay Service MIB Working Group                           [Page 8] 
  229.  RFC 1604                Frame Relay Service MIB               March 1994 
  230.  
  231.             Object   Use for the generic Frame Relay layer            ======   =========================================            ifIndex          Each Frame Relay port is represented                             by an ifEntry. 
  232.  
  233.            ifDescr          Description of the Frame Relay interface.                             ASCII string describing the UNI/NNI                             logical port.  Can be up to                             255 characters long. 
  234.  
  235.            ifType           The value allocated for Frame Relay                             Service is equal to 44. 
  236.  
  237.            ifMtu            Set to maximum frame size in octets for                             this frame relay logical port. 
  238.  
  239.            ifSpeed          Peak bandwidth in bits per second                             available for use.  This could be the                             speed of the logical port and not                             the access rate. Actual user information                             transfer rate (i.e., access rate) of the                             UNI or NNI logical port in bits per second                             (this is not the clocking speed).  For                             example, it is 1,536,000 bits per                             second for a DS1-based UNI/NNI logical                             port and 1,984,000 bits per second for an                             E1-based UNI/NNI logical port. 
  240.  
  241.            ifPhysAddress    The primary address for this logical port                             assigned by the Frame Relay interface                             provider.  An octet string of zero length                             if no address is used for this logical                             port. 
  242.  
  243.            ifAdminStatus     The desired administrative status of the                              frame relay logical port. 
  244.  
  245.            ifOperStatus      The current operational status of the                              Frame Relay UNI or NNI logical port. 
  246.  
  247.            ifLastChange      The elapsed time since the last                              re-initialization of the logical port.                              The value of sysUpTime at the time the                              logical port entered its current                              operational state.  If the current                              state was entered prior to the last                              re-initialization of the local                              network management subsystem, then 
  248.  
  249.  
  250.  
  251. Frame Relay Service MIB Working Group                           [Page 9] 
  252.  RFC 1604                Frame Relay Service MIB               March 1994 
  253.  
  254.                               this object contains a zero value. 
  255.  
  256.            ifInOctets        The number of received octets.                              This counter only counts octets from the                              beginning of the frame relay header field                              to the end of user data. 
  257.  
  258.            ifInUcastPkts     The number of received unerrored,                              unicast frames. 
  259.  
  260.            ifInDiscards      The number of received frames discarded.                              Possible reasons are as follows:                              policing, congestion. 
  261.  
  262.            ifInErrors        The number of received frames that are                              discarded, because of an error.                              Possible errors can be the following: the                              frame relay frames were too long or were                              too short, the frames had an invalid or                              unrecognized DLCI values, or incorrect                              header values. 
  263.  
  264.            ifInUnknownProtos  The number of packets discarded because                               of an unknown or unsupported protocol.                               For Frame Relay Service interfaces, this                               counter will always be zero. 
  265.  
  266.            ifOutOctets       The number of transmitted octets.                              This counter only counts octets from the                              beginning of the frame relay header field                              to the end of user data. 
  267.  
  268.            ifOutUcastpkts    The number of frames sent. 
  269.  
  270.            ifOutDiscards     The number of frames discarded in the                              egress direction. Possible                              reasons are as follows:  policing,                              congestion. 
  271.  
  272.            ifOutErrors       The number of frames discarded in the                              egress direction, because of errors.                              Possible reason is transmit underruns. 
  273.  
  274.            ifName            This variable is not applicable for                              Frame Relay Service interfaces,                              therefore, this variable contains a                              zero-length string. 
  275.  
  276.  
  277.  
  278.  Frame Relay Service MIB Working Group                          [Page 10] 
  279.  RFC 1604                Frame Relay Service MIB               March 1994 
  280.  
  281.             ifInMulticastPkts  The number of received unerrored,                               multicast frames. 
  282.  
  283.            ifInBroadcastPkts  This variable is not applicable for                               Frame Relay Service interfaces,                               therefore, this counter is always zero. 
  284.  
  285.            ifOutMulticastPkts  The number of sent unerrored,                                multicast frames. 
  286.  
  287.            ifOutBroadcastPkts  This variable is not applicable for                                Frame Relay Service interfaces,                                therefore, this counter is always zero. 
  288.  
  289.            ifHCInOctets      Only used for DS3-based (and greater)                              Frame Relay logical ports.                              The number of received octets.                              This counter only counts octets from the                              beginning of the frame relay header field                              to the end of user data. 
  290.  
  291.            ifHCOutOctets     Only used for DS3-based (and greater)                              Frame Relay logical ports.                              The number of transmitted octets.                              This counter only counts octets from the                              beginning of the frame relay header field                              to the end of user data. 
  292.  
  293.            ifLinkUpDownTrapEnble  The value of this object is                                   implementation specific for Frame                                   Relay logical ports. 
  294.  
  295.            ifHighSpeed         Set to the user data rate of the frame                                relay logical port in millions of                                bits per second.  If the user data rate                                is less than 1 Mbps, then this value is                                zero. 
  296.  
  297.            ifPromiscuousMode   Set to false(2). 
  298.  
  299.            ifConnectorPresent  Set to false(2). 
  300.  
  301.    Frame Relay Network Service interfaces support the Interface Stack    Group.  Frame Relay Network Service interfaces do not support any    other groups or objects in the Interfaces group of MIB II.  Also,    supporting the SNMP Group of MIB II is an implementation choice. 
  302.  
  303.  
  304.  
  305.  
  306.  
  307. Frame Relay Service MIB Working Group                          [Page 11] 
  308.  RFC 1604                Frame Relay Service MIB               March 1994 
  309.  
  310.  4.  Object Definitions 
  311.  
  312.  FRNETSERV-MIB DEFINITIONS ::= BEGIN 
  313.  
  314.  IMPORTS     MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,     Counter32, Integer32,     TimeTicks                                FROM SNMPv2-SMI     DisplayString, PhysAddress,     TimeStamp, RowStatus                     FROM SNMPv2-TC     MODULE-COMPLIANCE, OBJECT-GROUP          FROM SNMPv2-CONF     ifIndex, transmission                    FROM RFC-1213; 
  315.  
  316.  frnetservMIB MODULE-IDENTITY       LAST-UPDATED "9311161200Z"       ORGANIZATION "IETF Frame Relay Network MIB Working Group"       CONTACT-INFO             "   Tracy A. Brown                 Bellcore                 331 Newman Springs Rd.                 Red Bank, NJ 07701 USA 
  317.  
  318.                 Tel: 1-908-758-2107                 Fax: 1-908-758-4177                 E-mail: tacox@mail.bellcore.com."       DESCRIPTION                "The MIB module to describe generic objects for                Frame Relay Network Service."       ::= { transmission 44 } 
  319.  
  320.       IfIndex ::= TEXTUAL-CONVENTION             STATUS  current             DESCRIPTION                "The value of this object identifies the                interface for which this entry contains                management information.  The value of this                object for a particular interface has the same                value as the ifIndex object, defined in RFC                1213, for the same interface."             SYNTAX Integer32 
  321.  
  322.       frnetservObjects  OBJECT IDENTIFIER ::= { frnetservMIB 1 }       frnetservTraps    OBJECT IDENTIFIER ::= { frnetservMIB 2 } 
  323.  
  324.   -- The Frame Relay Service Logical Port Group 
  325.  
  326.  --  the Frame Relay Logical Port Group 
  327.  
  328.  
  329.  
  330. Frame Relay Service MIB Working Group                          [Page 12] 
  331.  RFC 1604                Frame Relay Service MIB               March 1994 
  332.  
  333.   --  This table is an interface specific addendum  --  to the generic ifTable from MIB-II. 
  334.  
  335. frLportTable OBJECT-TYPE  SYNTAX  SEQUENCE OF FrLportEntry  MAX-ACCESS  not-accessible  STATUS  current  DESCRIPTION          "The Frame Relay Logical Port Information table."  ::= { frnetservObjects 1 } 
  336.  
  337. frLportEntry OBJECT-TYPE  SYNTAX  FrLportEntry  MAX-ACCESS  not-accessible  STATUS  current  DESCRIPTION           "An entry in the Frame Relay Logical Port           Information table."  INDEX   { ifIndex }  ::= { frLportTable 1 } 
  338.  
  339. FrLportEntry ::=   SEQUENCE {       frLportNumPlan           INTEGER,       frLportContact           DisplayString,       frLportLocation           DisplayString,       frLportType           INTEGER,       frLportAddrDLCILen           INTEGER,       frLportVCSigProtocol           INTEGER,       frLportVCSigPointer           OBJECT IDENTIFIER  } 
  340.  
  341.   frLportNumPlan OBJECT-TYPE      SYNTAX  INTEGER {                other(1),                e164(2),                x121(3),                none(4)              }      MAX-ACCESS  read-only 
  342.  
  343.  
  344.  
  345. Frame Relay Service MIB Working Group                          [Page 13] 
  346.  RFC 1604                Frame Relay Service MIB               March 1994 
  347.  
  348.       STATUS  current      DESCRIPTION              "The value of this object identifies the network              address numbering plan for this UNI/NNI logical              port. The network address is the object              ifPhysAddress. The value none implies that there              is no ifPhysAddress.  The SNMP proxy-agent will              return an octet string of zero length for              ifPhysAddress. The value other means that an              address has been assigned to this interface, but              the numbering plan is not enumerated here."      ::= { frLportEntry 1 } 
  349.  
  350.  frLportContact OBJECT-TYPE      SYNTAX  DisplayString (SIZE(0..255))      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The value of this object identifies the network              contact for this UNI/NNI logical port."      ::= { frLportEntry 2 } 
  351.  
  352.  frLportLocation OBJECT-TYPE      SYNTAX  DisplayString (SIZE(0..255))      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The value of this object identifies the Frame              Relay network location for this UNI/NNI logical              port."      ::= { frLportEntry 3 } 
  353.  
  354.  frLportType OBJECT-TYPE      SYNTAX  INTEGER {                uni(1),                nni(2)              }      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The value of this object identifies the type of              network interface for this logical port."      ::= { frLportEntry 4 } 
  355.  
  356.  frLportAddrDLCILen OBJECT-TYPE      SYNTAX  INTEGER {       twoOctets10Bits(1),       threeOctets10Bits(2), 
  357.  
  358.  
  359.  
  360. Frame Relay Service MIB Working Group                          [Page 14] 
  361.  RFC 1604                Frame Relay Service MIB               March 1994 
  362.  
  363.        threeOctets16Bits(3),       fourOctets17Bits(4),       fourOctets23Bits(5)     }      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The value of this object identifies the Q.922              Address field length and DLCI length for this              UNI/NNI logical port."      ::= { frLportEntry 5 } 
  364.  
  365.  frLportVCSigProtocol OBJECT-TYPE      SYNTAX  INTEGER {                none(1),                lmi(2),                ansiT1617D(3),                ansiT1617B(4),                ccittQ933A(5)              }      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The value of this object identifies the Local              In-Channel Signaling Protocol that is used for              this frame relay UNI/NNI logical port."      ::= { frLportEntry 6 } 
  366.  
  367.  frLportVCSigPointer OBJECT-TYPE      SYNTAX  OBJECT IDENTIFIER      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The value of this object is used as a pointer to              the table that contains the Local In-Channel              Signaling Protocol parameters and errors for this              UNI/NNI logical port.  See the Frame Relay              Management VC Signaling Parameters and Errors              Group."      ::= { frLportEntry 7 } 
  368.  
  369.   -- the Frame Relay Management VC Signaling Group 
  370.  
  371.  -- This Group contains managed objects for the  -- Local In-Channel Signaling Parameters and  -- for signaling errors. 
  372.  
  373.  
  374.  
  375.  Frame Relay Service MIB Working Group                          [Page 15] 
  376.  RFC 1604                Frame Relay Service MIB               March 1994 
  377.  
  378.   frMgtVCSigTable OBJECT-TYPE      SYNTAX  SEQUENCE OF FrMgtVCSigEntry      MAX-ACCESS  not-accessible      STATUS  current      DESCRIPTION              "The Frame Relay Management VC Signaling              Parameters and Errors table."      ::= { frnetservObjects 2 } 
  379.  
  380.  frMgtVCSigEntry OBJECT-TYPE      SYNTAX  FrMgtVCSigEntry      MAX-ACCESS  not-accessible      STATUS  current      DESCRIPTION              "An entry in the Frame Relay Management VC              Signaling Parameters Errors table."      INDEX   { ifIndex }      ::= { frMgtVCSigTable 1 } 
  381.  
  382.  FrMgtVCSigEntry ::=      SEQUENCE {          frMgtVCSigProced              INTEGER,          frMgtVCSigUserN391              INTEGER,          frMgtVCSigUserN392              INTEGER,          frMgtVCSigUserN393              INTEGER,          frMgtVCSigUserT391              INTEGER,          frMgtVCSigNetN392              INTEGER,          frMgtVCSigNetN393              INTEGER,          frMgtVCSigNetT392              INTEGER,          frMgtVCSigNetnN4              INTEGER,          frMgtVCSigNetnT3              INTEGER,          frMgtVCSigUserLinkRelErrors              Counter32,          frMgtVCSigUserProtErrors              Counter32,          frMgtVCSigUserChanInactive              Counter32,          frMgtVCSigNetLinkRelErrors 
  383.  
  384.  
  385.  
  386. Frame Relay Service MIB Working Group                          [Page 16] 
  387.  RFC 1604                Frame Relay Service MIB               March 1994 
  388.  
  389.               Counter32,          frMgtVCSigNetProtErrors              Counter32,          frMgtVCSigNetChanInactive              Counter32  } 
  390.  
  391.   frMgtVCSigProced OBJECT-TYPE      SYNTAX  INTEGER {                u2nnet(1),                bidirect(2)              }      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The value of this object identifies the Local              In-Channel Signaling Procedure that is used for              this UNI/NNI logical port.  The UNI/NNI logical              port can be performing only user-to-network              network-side procedures or bidirectional              procedures."      ::= { frMgtVCSigEntry 1 } 
  392.  
  393.  frMgtVCSigUserN391 OBJECT-TYPE      SYNTAX  INTEGER (1..255)      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The value of this object identifies the User-side              N391 full status polling cycle value for this              UNI/NNI logical port.  If the logical port is not              performing user-side procedures, then this value              is equal to noSuchName. This object applies to              Q.933 Annex A and T1.617 Annex D."      DEFVAL { 6 }      ::= { frMgtVCSigEntry 2 } 
  394.  
  395.  frMgtVCSigUserN392 OBJECT-TYPE      SYNTAX  INTEGER (1..10)      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The value of this object identifies the User-side              N392 error threshold value for this UNI/NNI              logical port.  If the logical port is not              performing user-side procedures, then this value              is equal to noSuchName. This object applies to 
  396.  
  397.  
  398.  
  399. Frame Relay Service MIB Working Group                          [Page 17] 
  400.  RFC 1604                Frame Relay Service MIB               March 1994 
  401.  
  402.               Q.933 Annex A and T1.617 Annex D."      DEFVAL { 3 }      ::= { frMgtVCSigEntry 3 } 
  403.  
  404.  frMgtVCSigUserN393 OBJECT-TYPE      SYNTAX  INTEGER (1..10)      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The value of this object identifies the User-side              N393 monitored events count value for this UNI/NNI              logical port.  If the logical port is not              performing user-side procedures, then this value              is equal to noSuchName. This object applies to              Q.933 Annex A and T1.617 Annex D."      DEFVAL { 4 }      ::= { frMgtVCSigEntry 4 } 
  405.  
  406.  frMgtVCSigUserT391 OBJECT-TYPE      SYNTAX  INTEGER (5..30)      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The value of this object identifies the User-side              T391 link integrity verification polling timer              value for this UNI/NNI logical port.  If the              logical port is not performing user-side              procedures, then this value is equal to              noSuchName. This object applies to Q.933 Annex A              and T1.617 Annex D."      DEFVAL { 10 }      ::= { frMgtVCSigEntry 5 } 
  407.  
  408.  frMgtVCSigNetN392 OBJECT-TYPE      SYNTAX  INTEGER (1..10)      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The value of this object identifies the Network-              side N392 error threshold value (nN2 for LMI) for              this UNI/NNI logical port.  If the logical port is              not performing network-side procedures, then this              value is equal to noSuchName. This object applies              to Q.933 Annex A, T1.617 Annex D and LMI."      DEFVAL { 3 }      ::= { frMgtVCSigEntry 6 } 
  409.  
  410.  frMgtVCSigNetN393 OBJECT-TYPE 
  411.  
  412.  
  413.  
  414. Frame Relay Service MIB Working Group                          [Page 18] 
  415.  RFC 1604                Frame Relay Service MIB               March 1994 
  416.  
  417.       SYNTAX  INTEGER (1..10)      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The value of this object identifies the Network-              side N393 monitored events count value (nN3 for              LMI) for this UNI/NNI logical port.  If the              logical port is not performing network-side              procedures, then this value is equal to              noSuchName. This object applies to Q.933 Annex A,              T1.617 Annex D and LMI."      DEFVAL { 4 }      ::= { frMgtVCSigEntry 7 } 
  418.  
  419.  frMgtVCSigNetT392 OBJECT-TYPE      SYNTAX  INTEGER (5..30)      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The value of this object identifies the Network-              side T392 polling verification timer value (nT2              for LMI)  for this UNI/NNI logical port.  If the              logical port is not performing network-side              procedures, then this value is equal to              noSuchName. This object applies to Q.933 Annex A,              T1.617 Annex D and LMI."      DEFVAL { 15 }      ::= { frMgtVCSigEntry 8 } 
  420.  
  421.  frMgtVCSigNetnN4 OBJECT-TYPE      SYNTAX  INTEGER (5..5)      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The value of this object identifies the Network-              side nN4 maximum status enquires received value              for this UNI/NNI logical port.  If the logical              port is not performing network-side procedures or              is not performing LMI procedures, then this value              is equal to noSuchName. This object applies only              to LMI and always has a value of 5."      ::= { frMgtVCSigEntry 9 } 
  422.  
  423.  frMgtVCSigNetnT3 OBJECT-TYPE      SYNTAX  INTEGER (5 | 10 | 15 | 20 | 25 | 30)      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION 
  424.  
  425.  
  426.  
  427. Frame Relay Service MIB Working Group                          [Page 19] 
  428.  RFC 1604                Frame Relay Service MIB               March 1994 
  429.  
  430.               "The value of this object identifies the Network-              side nT3 timer (for nN4 status enquires received)              value for this UNI/NNI logical port.  If the              logical port is not performing network-side              procedures or is not performing LMI procedures,              then this value is equal to noSuchName. This              object applies only to LMI."      DEFVAL { 20 }      ::= { frMgtVCSigEntry 10 } 
  431.  
  432.  frMgtVCSigUserLinkRelErrors OBJECT-TYPE      SYNTAX  Counter32      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The number of user-side local in-channel              signaling link reliability errors (i.e., non-              receipt of Status/Status Enquiry messages or              invalid sequence numbers in a Link Integrity              Verification Information Element) for this UNI/NNI              logical port.  If the logical port is not              performing user-side procedures, then this value              is equal to noSuchName."      ::= { frMgtVCSigEntry 11 } 
  433.  
  434.  frMgtVCSigUserProtErrors OBJECT-TYPE      SYNTAX  Counter32      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The number of user-side local in-channel              signaling protocol errors (i.e., protocol              discriminator, message type, call reference, and              mandatory information element errors) for this              UNI/NNI logical port.  If the logical port is not              performing user-side procedures, then this value              is equal to noSuchName."      ::= { frMgtVCSigEntry 12 } 
  435.  
  436.  frMgtVCSigUserChanInactive OBJECT-TYPE      SYNTAX  Counter32      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The number of times the user-side channel was              declared inactive (i.e., N392 errors in N393              events) for this UNI/NNI logical port. If the              logical port is not performing user-side 
  437.  
  438.  
  439.  
  440. Frame Relay Service MIB Working Group                          [Page 20] 
  441.  RFC 1604                Frame Relay Service MIB               March 1994 
  442.  
  443.               procedures, then this value is equal to              noSuchName."      ::= { frMgtVCSigEntry 13 } 
  444.  
  445.  frMgtVCSigNetLinkRelErrors OBJECT-TYPE      SYNTAX  Counter32      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The number of network-side local in-channel              signaling link reliability errors (i.e., non-              receipt of Status/Status Enquiry messages or              invalid sequence numbers in a Link Integrity              Verification Information Element) for this UNI/NNI              logical port.  If the logical port is not              performing network-side procedures, then this              value is equal to noSuchName."      ::= { frMgtVCSigEntry 14 } 
  446.  
  447.  frMgtVCSigNetProtErrors OBJECT-TYPE      SYNTAX  Counter32      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The number of network-side local in-channel              signaling protocol errors (i.e., protocol              discriminator, message type, call reference, and              mandatory information element errors) for this              UNI/NNI logical port.  If the logical port is not              performing network-side procedures, then this              value is equal to noSuchName."      ::= { frMgtVCSigEntry 15 } 
  448.  
  449.  frMgtVCSigNetChanInactive OBJECT-TYPE      SYNTAX  Counter32      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The number of times the network-side channel was              declared inactive (i.e., N392 errors in N393              events) for this UNI/NNI logical port.  If the              logical port is not performing network-side              procedures, then this value is equal to              noSuchName."      ::= { frMgtVCSigEntry 16 } 
  450.  
  451.  
  452.  
  453.  
  454.  
  455.  Frame Relay Service MIB Working Group                          [Page 21] 
  456.  RFC 1604                Frame Relay Service MIB               March 1994 
  457.  
  458.   -- The PVC End-Point Group 
  459.  
  460.  -- This table is used to identify the traffic parameters  -- for a bi-directional PVC segment end-point, and it also  -- provides statistics for a PVC segment  -- end-point. 
  461.  
  462.  -- A PVC segment end-point is identified by a UNI/NNI  -- logical port index value and DLCI index value. 
  463.  
  464.  -- If the Frame Relay service provider allows  -- the Frame Relay CNM subscriber to create, modify  -- or delete PVCs using SNMP, then this table is used to identify  -- and reserve  -- the requested traffic parameters of each  -- PVC segment end-point.  The Connection table  -- is used to "connect" the end-points together.  -- Not all implementations will support the  -- capability of creating/modifying/deleting  -- PVCs using SNMP as a feature of Frame Relay  -- CNM service. 
  465.  
  466.  -- Uni-directional PVCs are modeled with zero  -- valued traffic parameters in one of the  -- directions (In or Out direction) in this table. 
  467.  
  468.  -- To create a PVC, the following procedures  -- shall be followed:  -- 1). Create the entries for the PVC segment endpoints in the  --     frPVCEndptTable by specifying the traffic parameters  --     for the bi-directional PVC segment endpoints.  --     As shown in the figure, a point-to-point PVC has  --     two endpoints, thus two entries in this table.  --     Uni-directional PVCs are modeled  --     with zero valued traffic parameters in one  --     direction; all the `In' direction parameters  --     for one Frame Relay PVC End-point or  --     all the `Out' direction  --     parameters for the other Frame Relay PVC  --     End-point. 
  469.  
  470.  
  471.  
  472.  
  473.  
  474.  
  475.  
  476.  
  477.  
  478.  
  479.  
  480. Frame Relay Service MIB Working Group                          [Page 22] 
  481.  RFC 1604                Frame Relay Service MIB               March 1994 
  482.  
  483.   --     In    ____________________________________ Out  --    >>>>>>|                                   |>>>>>>>>  --    ______| Frame Relay Network               |__________  --     Out  |                                   |  In  --    <<<<<<|                                   |<<<<<<<<  --          |___________________________________|  --  Frame Relay PVC                            Frame Relay  --   End-point                                 PVC  End-point 
  484.  
  485.  -- 2). Go to the Frame Relay Connection Group.  -- 
  486.  
  487.  -- The Frame Relay PVC End-point Table 
  488.  
  489.  frPVCEndptTable OBJECT-TYPE      SYNTAX  SEQUENCE OF FrPVCEndptEntry      MAX-ACCESS  not-accessible      STATUS  current      DESCRIPTION              "The Frame Relay PVC End-Point table.  This table              is used to model a PVC end-point.  This table              contains the traffic parameters and statistics for              a PVC end-point."      ::= { frnetservObjects 3 } 
  490.  
  491.  frPVCEndptEntry OBJECT-TYPE      SYNTAX  FrPVCEndptEntry      MAX-ACCESS  not-accessible      STATUS  current      DESCRIPTION              "An entry in the Frame Relay PVC Endpoint table."      INDEX   { ifIndex, frPVCEndptDLCIIndex }      ::= { frPVCEndptTable 1 } 
  492.  
  493.  FrPVCEndptEntry ::=      SEQUENCE {          frPVCEndptDLCIIndex              Integer32,          frPVCEndptInMaxFrameSize              Integer32,          frPVCEndptInBc              Integer32,          frPVCEndptInBe              Integer32,          frPVCEndptInCIR             Integer32,          frPVCEndptOutMaxFrameSize              Integer32, 
  494.  
  495.  
  496.  
  497. Frame Relay Service MIB Working Group                          [Page 23] 
  498.  RFC 1604                Frame Relay Service MIB               March 1994 
  499.  
  500.           frPVCEndptOutBc              Integer32,          frPVCEndptOutBe              Integer32,          frPVCEndptOutCIR              Integer32,          frPVCEndptConnectIdentifier              Integer32,          frPVCEndptRowStatus              RowStatus,          frPVCEndptRcvdSigStatus              INTEGER,          frPVCEndptInFrames              Counter32,          frPVCEndptOutFrames              Counter32,          frPVCEndptInDEFrames              Counter32,          frPVCEndptInExcessFrames              Counter32,          frPVCEndptOutExcessFrames              Counter32,          frPVCEndptInDiscards              Counter32,          frPVCEndptInOctets              Counter32,          frPVCEndptOutOctets              Counter32      } 
  501.  
  502.   frPVCEndptDLCIIndex OBJECT-TYPE      SYNTAX  Integer32      MAX-ACCESS  not-accessible      STATUS  current      DESCRIPTION              "The value of this object is equal to the DLCI              value for this PVC end-point."      ::= { frPVCEndptEntry 1 } 
  503.  
  504.  frPVCEndptInMaxFrameSize OBJECT-TYPE      SYNTAX  Integer32      MAX-ACCESS  read-create      STATUS  current      DESCRIPTION              "The value of this object is the size in octets of              the largest frame relay information field for this              PVC end-point in the ingress direction (into the 
  505.  
  506.  
  507.  
  508. Frame Relay Service MIB Working Group                          [Page 24] 
  509.  RFC 1604                Frame Relay Service MIB               March 1994 
  510.  
  511.               frame relay network).  The value of              frPVCEndptInMaxFrameSize must be less than or              equal to the corresponding ifMtu for this Frame              Relay UNI/NNI logical port."      ::= { frPVCEndptEntry 2 } 
  512.  
  513.  frPVCEndptInBc OBJECT-TYPE      SYNTAX  Integer32      MAX-ACCESS  read-create      STATUS  current      DESCRIPTION              "The value of this object is equal to the              committed burst size (Bc) parameter (measured in              bits) for this PVC end-point in the ingress              direction (into the frame relay network)."      ::= { frPVCEndptEntry 3 } 
  514.  
  515.  frPVCEndptInBe OBJECT-TYPE      SYNTAX  Integer32      MAX-ACCESS  read-create      STATUS  current      DESCRIPTION              "The value of this object is equal to the excess              burst size (Be) parameter (measured in bits) for              this PVC end-point in the ingress direction (into              the frame relay network)."      ::= { frPVCEndptEntry 4 } 
  516.  
  517.  frPVCEndptInCIR OBJECT-TYPE      SYNTAX  Integer32      MAX-ACCESS  read-create      STATUS  current      DESCRIPTION              "The value of this object is equal to the              committed information rate (CIR) parameter              (measured in bits per second) for this PVC end-              point in the ingress direction (into the frame              relay network)."      ::= { frPVCEndptEntry 5 } 
  518.  
  519.  frPVCEndptOutMaxFrameSize OBJECT-TYPE      SYNTAX  Integer32      MAX-ACCESS  read-create      STATUS  current      DESCRIPTION              "The value of this object is the size in octets of              the largest frame relay information field for this              PVC end-point in the egress direction (out of the 
  520.  
  521.  
  522.  
  523. Frame Relay Service MIB Working Group                          [Page 25] 
  524.  RFC 1604                Frame Relay Service MIB               March 1994 
  525.  
  526.               frame relay network).  The value of              frPVCEndptOutMaxFrameSize must be less than or              equal to the corresponding ifMtu for this Frame              Relay UNI/NNI logical port."      ::= { frPVCEndptEntry 6 } 
  527.  
  528.  frPVCEndptOutBc OBJECT-TYPE      SYNTAX  Integer32      MAX-ACCESS  read-create      STATUS  current      DESCRIPTION              "The value of this object is equal to the              committed burst size (Bc) parameter (measured in              bits) for this PVC end-point in the egress              direction (out of the frame relay network)."      ::= { frPVCEndptEntry 7 } 
  529.  
  530.  frPVCEndptOutBe OBJECT-TYPE      SYNTAX  Integer32      MAX-ACCESS  read-create      STATUS  current      DESCRIPTION              "The value of this object is equal to the excess              burst size (Be) parameter (measured in bits) for              this PVC end-point in the egress direction (out of              the frame relay network)."      ::= { frPVCEndptEntry 8 } 
  531.  
  532.  frPVCEndptOutCIR OBJECT-TYPE      SYNTAX  Integer32      MAX-ACCESS  read-create      STATUS  current      DESCRIPTION              "The value of this object is equal to the              committed information rate (CIR) parameter              (measured in bits per second) for this PVC end-              point in the egress direction (out of the frame              relay network)."      ::= { frPVCEndptEntry 9 } 
  533.  
  534.  frPVCEndptConnectIdentifier OBJECT-TYPE      SYNTAX  Integer32      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "This object is used to associate PVC end-points              as being part of one PVC segment connection.  This              value of this object is equal to the value of 
  535.  
  536.  
  537.  
  538. Frame Relay Service MIB Working Group                          [Page 26] 
  539.  RFC 1604                Frame Relay Service MIB               March 1994 
  540.  
  541.               frPVCConnectIndex, which is used as one of the              indices into the frPVCConnectTable.  The value of              this object is provided by the agent, after the              associated entries in the frPVCConnectTable have              been created."      ::= { frPVCEndptEntry 10 } 
  542.  
  543.  frPVCEndptRowStatus OBJECT-TYPE      SYNTAX  RowStatus      MAX-ACCESS  read-create      STATUS  current      DESCRIPTION              "This object is used to create new rows in this              table, modify existing rows, and to delete              existing rows.  To create a new PVC, the entries              for the PVC segment end-points in the              frPVCEndptTable must first be created.  Next, the              frPVCConnectTable is used to associate the Frame              Relay PVC segment end-points.  In order for the              manager to have the necessary error diagnostics,              the frPVCEndptRowStatus object must initially be              set to `createAndWait'.  While the              frPVCEndptRowStatus object is in the              `createAndWait' state, the manager can set each              columnar object and get the necessary error              diagnostics.  The frPVCEndptRowStatus object may              not be set to `active' unless the following              columnar objects exist in this row:              frPVCEndptInMaxFrameSize, frPVCEndptInBc,              frPVCEndptInBe, frPVCEndptInCIR,              frPVCEndptOutMaxFrameSize, frPVCEndptOutBc,              frPVCEndptOutBe, and frPVCEndptOutCIR."      ::= { frPVCEndptEntry 11 } 
  544.  
  545.  frPVCEndptRcvdSigStatus OBJECT-TYPE      SYNTAX  INTEGER {                deleted(1),                active(2),                inactive(3),                none(4)              }      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The value of this object identifies the PVC              status received via the local in-channel signaling              procedures for this PVC end-point.  This object is              only pertinent for interfaces that perform the 
  546.  
  547.  
  548.  
  549. Frame Relay Service MIB Working Group                          [Page 27] 
  550.  RFC 1604                Frame Relay Service MIB               March 1994 
  551.  
  552.               bidirectional procedures.  For user-to-network              network side procedures, the value of this object              should be none."      ::= { frPVCEndptEntry 12 } 
  553.  
  554.  frPVCEndptInFrames OBJECT-TYPE      SYNTAX  Counter32      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The number of frames received by the network              (ingress) for this PVC end-point. This includes              any frames discarded by the network due to              submitting more than Bc + Be data or due to any              network congestion recovery procedures."      ::= { frPVCEndptEntry 13 } 
  555.  
  556.  frPVCEndptOutFrames OBJECT-TYPE      SYNTAX  Counter32      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The number of frames sent by the network (egress)              regardless of whether they are Bc or Be frames for              this PVC end-point."      ::= { frPVCEndptEntry 14 } 
  557.  
  558.  frPVCEndptInDEFrames OBJECT-TYPE      SYNTAX  Counter32      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The number of frames received by the network              (ingress) with the DE bit set to (1) for this PVC              end-point."      ::= { frPVCEndptEntry 15 } 
  559.  
  560.  frPVCEndptInExcessFrames OBJECT-TYPE      SYNTAX  Counter32      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The number of frames received by the network              (ingress) for this PVC end-point which were              treated as excess traffic.  Frames which are sent              to the network with DE set to zero are treated as              excess when more than Bc bits are submitted to the              network during the Committed Information Rate 
  561.  
  562.  
  563.  
  564. Frame Relay Service MIB Working Group                          [Page 28] 
  565.  RFC 1604                Frame Relay Service MIB               March 1994 
  566.  
  567.               Measurement Interval (Tc).  Excess traffic may or              may not be discarded at the ingress if more than              Bc + Be bits are submitted to the network during              Tc.  Traffic discarded at the ingress is not              recorded in frPVCEndptInExcessFrames.  Frames              which are sent to the network with DE set to one              are also treated as excess traffic."      ::= { frPVCEndptEntry 16 } 
  568.  
  569.  frPVCEndptOutExcessFrames OBJECT-TYPE      SYNTAX  Counter32      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The number of frames sent by the network (egress)              for this PVC end-point which were treated as              excess traffic.  (The DE bit may be set to one.)"      ::= { frPVCEndptEntry 17 } 
  570.  
  571.  frPVCEndptInDiscards OBJECT-TYPE      SYNTAX  Counter32      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The number of frames received by the the network              (ingress) that were discarded due to traffic              enforcement for this PVC end-point."      ::= { frPVCEndptEntry 18 } 
  572.  
  573.  frPVCEndptInOctets OBJECT-TYPE      SYNTAX  Counter32      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The number of octets received by the network              (ingress) for this PVC end-point.  This counter              should only count octets from the beginning of the              frame relay header field to the end of user data.              If the network supporting Frame Relay can not              count octets, then this count should be an              approximation."      ::= { frPVCEndptEntry 19 } 
  574.  
  575.  frPVCEndptOutOctets OBJECT-TYPE      SYNTAX  Counter32      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION 
  576.  
  577.  
  578.  
  579. Frame Relay Service MIB Working Group                          [Page 29] 
  580.  RFC 1604                Frame Relay Service MIB               March 1994 
  581.  
  582.               "The number of octets sent by the network (egress)              for this PVC end-point.  This counter should only              count octets from the beginning of the frame relay              header field to the end of user data.  If the              network supporting Frame Relay can not count              octets, then this count should be an              approximation."      ::= { frPVCEndptEntry 20 } 
  583.  
  584.   -- The Frame Relay PVC Connection Group 
  585.  
  586.  -- The Frame Relay PVC Connection Group  -- is used to model the bi-directional  -- PVC segment flows;  -- point-to-point PVCs, point-to-multipoint  -- PVCs, and multipoint-to-multipoint  -- PVCs. 
  587.  
  588.  -- This table has read-create access and  -- is used to associate PVC end-points  -- together as belonging to one connection.  -- The frPVCConnectIndex is used to associate  -- all the bi-directional flows.  -- Not all implementations will support the  -- capability of creating/modifying/deleting  -- PVCs using SNMP as a feature of Frame Relay  -- CNM service. 
  589.  
  590.  -- Once the entries in the frPVCEndptTable  -- are created, the following step are used  -- to associate the PVC end-points as belonging  -- to one PVC connection:  -- 1). Obtain a unique frPVCConnectIndex  --     using the frPVCConnectIndexValue object.  -- 2). Connect the PVC segment endpoints together  --     with the applicable frPVCConnectIndex value  --     obtained via  --     frPVCConnectIndexValue.  --     The entries in this table are created by using  --     the frPVCConnectRowStatus object.  -- 3). The agent will provide the value of the  --     corresponding instances of  --     frPVCEndptConnectIdentifier with the  --     the frPVCConnectIndex value.  -- 4). Set frPVCConnectAdminStatus to `active' in all  --     rows for this PVC segment to  --     turn the PVC on. 
  591.  
  592.  
  593.  
  594. Frame Relay Service MIB Working Group                          [Page 30] 
  595.  RFC 1604                Frame Relay Service MIB               March 1994 
  596.  
  597.   -- For example, the Frame Relay PVC Connection Group  -- models a bi-directional, point-to-point PVC segment  -- as one entry in this table. 
  598.  
  599.  -- Frame Relay Network                  Frame Relay Network  --  Low Port ____________________________________ High Port  --          |                                   |  --    ______| >> from low to high PVC flow   >> |____________  --          | << from high to low PVC flow   << |  --          |___________________________________|  -- 
  600.  
  601.  -- The terms low and high are chosen to represent numerical  -- ordering of a PVC segment's endpoints for representation  -- in this table.  That is, the endpoint with the lower value  -- of ifIndex is termed 'low', while the opposite endpoint  -- of the segment is termed 'high'.  -- This terminology is to provide directional information;  -- for example the frPVCConnectL2hOperStatus and  -- frPVCConnectH2lOperStatus as illustrated above. 
  602.  
  603.  -- If the Frame Relay Connection table is used to model  -- a unidirectional PVC, then one direction (either from low to high  -- or from high to low) has its Operational Status equal to down. 
  604.  
  605.  -- A PVC segment is a portion of a PVC  -- that traverses one Frame Relay Network, and  -- a PVC segment is identified  -- by its two end-points (UNI/NNI logical port index  -- value and DLCI index value)  -- through one Frame Relay Network. 
  606.  
  607.   frPVCConnectIndexValue OBJECT-TYPE      SYNTAX  INTEGER (0..2147483647)      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "This object contains an appropriate value to be              used for frPVCConnectIndex when creating entries              in the frPVCConnectTable.  The value 0 indicates              that no unassigned entries are available.  To              obtain the frPVCConnectIndex value for a new              entry, the manager issues a management protocol              retrieval operation to obtain the current value of              this object.  After each retrieval, the agent              should modify the value to the next unassigned              index." 
  608.  
  609.  
  610.  
  611. Frame Relay Service MIB Working Group                          [Page 31] 
  612.  RFC 1604                Frame Relay Service MIB               March 1994 
  613.  
  614.       ::= { frnetservObjects 4 } 
  615.  
  616.  --  The Frame Relay PVC Connection Table 
  617.  
  618.  frPVCConnectTable OBJECT-TYPE      SYNTAX  SEQUENCE OF FrPVCConnectEntry      MAX-ACCESS  not-accessible      STATUS  current      DESCRIPTION              "The Frame Relay PVC Connect table.  A bi-              directional PVC segment is modeled as one entry in              this table."      ::= { frnetservObjects 5 } 
  619.  
  620.  frPVCConnectEntry OBJECT-TYPE      SYNTAX  FrPVCConnectEntry      MAX-ACCESS  not-accessible      STATUS  current      DESCRIPTION              "An entry in the Frame Relay PVC Connect table.              This entry is used to model a PVC segment in two              directions."      INDEX { frPVCConnectIndex,              frPVCConnectLowIfIndex, frPVCConnectLowDLCIIndex,              frPVCConnectHighIfIndex, frPVCConnectHighDLCIIndex }      ::= { frPVCConnectTable 1 } 
  621.  
  622.  FrPVCConnectEntry ::=      SEQUENCE {          frPVCConnectIndex              Integer32,          frPVCConnectLowIfIndex              IfIndex,          frPVCConnectLowDLCIIndex              Integer32,          frPVCConnectHighIfIndex              IfIndex,          frPVCConnectHighDLCIIndex              Integer32,          frPVCConnectAdminStatus              INTEGER,          frPVCConnectL2hOperStatus              INTEGER,          frPVCConnectH2lOperStatus              INTEGER,          frPVCConnectL2hLastChange              TimeStamp,          frPVCConnectH2lLastChange 
  623.  
  624.  
  625.  
  626. Frame Relay Service MIB Working Group                          [Page 32] 
  627.  RFC 1604                Frame Relay Service MIB               March 1994 
  628.  
  629.               TimeStamp,          frPVCConnectRowStatus              RowStatus  } 
  630.  
  631.  frPVCConnectIndex OBJECT-TYPE      SYNTAX  Integer32      MAX-ACCESS  not-accessible      STATUS  current      DESCRIPTION              "The value of this object is equal to the              frPVCConnectIndexValue obtained to uniquely              identify this PVC segment connection."      ::= { frPVCConnectEntry 1 } 
  632.  
  633.  frPVCConnectLowIfIndex OBJECT-TYPE      SYNTAX  IfIndex      MAX-ACCESS  not-accessible      STATUS  current      DESCRIPTION              "The value of this object is equal to MIB II's              ifIndex value of the UNI/NNI logical port for this              PVC segment.  The term low implies that this PVC              segment end-point has the numerically lower              ifIndex value than the connected/associated PVC              segment end-point.  If the value is equal to zero,              then this logical port is not a Frame Relay              UNI/NNI logical port."      ::= { frPVCConnectEntry 2 } 
  634.  
  635.  frPVCConnectLowDLCIIndex OBJECT-TYPE      SYNTAX  Integer32      MAX-ACCESS  not-accessible      STATUS  current      DESCRIPTION              "The value of this object is equal to the DLCI              value for this end-point of the PVC segment.  If              the value is equal to zero, then this endpoint of              the PVC segment is not a Frame Relay connection."      ::= { frPVCConnectEntry 3 } 
  636.  
  637.  frPVCConnectHighIfIndex OBJECT-TYPE      SYNTAX  IfIndex      MAX-ACCESS  not-accessible      STATUS  current      DESCRIPTION              "The value of this object is equal to MIB II's              ifIndex value for the UNI/NNI logical port for 
  638.  
  639.  
  640.  
  641. Frame Relay Service MIB Working Group                          [Page 33] 
  642.  RFC 1604                Frame Relay Service MIB               March 1994 
  643.  
  644.               this PVC segment.  The term high implies that this              PVC segment end-point has the numerically higher              ifIndex value than the connected/associated PVC              segment end-point."      ::= { frPVCConnectEntry 4 } 
  645.  
  646.  frPVCConnectHighDLCIIndex OBJECT-TYPE      SYNTAX  Integer32      MAX-ACCESS  not-accessible      STATUS  current      DESCRIPTION              "The value of this object is equal to the egress              DLCI value for this end-point of the PVC segment."      ::= { frPVCConnectEntry 5 } 
  647.  
  648.  frPVCConnectAdminStatus OBJECT-TYPE      SYNTAX  INTEGER {                active(1),                inactive(2),                testing(3)              }      MAX-ACCESS  read-create      STATUS  current      DESCRIPTION              "The value of this object identifies the desired              administrative status of this bi-directional PVC              segment.  The active state means the PVC segment              is currently operational; the inactive state means              the PVC segment is currently not operational; the              testing state means the PVC segment is currently              undergoing a test.  This state is set by an              administrative entity.  This value affects the PVC              status indicated across the ingress NNI/UNI of              both end-points of the bi-directional PVC segment.              When a PVC segment connection is created using              this table, this object is initially set to              `inactive'.  After the frPVCConnectRowStatus              object is set to `active' (and the              corresponding/associated entries in the              frPVCEndptTable have their frPVCEndptRowStatus              object set to `active'), the              frPVCConnectAdminStatus object may be set to              `active' to turn on the PVC segment connection."      ::= { frPVCConnectEntry 6 } 
  649.  
  650.  frPVCConnectL2hOperStatus OBJECT-TYPE      SYNTAX  INTEGER {                active(1), 
  651.  
  652.  
  653.  
  654. Frame Relay Service MIB Working Group                          [Page 34] 
  655.  RFC 1604                Frame Relay Service MIB               March 1994 
  656.  
  657.                 inactive(2),                testing(3),                unknown(4)              }      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The value of this object identifies the current              operational status of the PVC segment connection              in one direction; (i.e., in the low to high              direction).  The active state means it is              currently operational; the inactive state means it              is currently not operational; the testing state              means it is currently undergoing a test; the              unknown state means the status of it currently can              not be determined.  This value affects the PVC              status indicated across the ingress NNI/UNI (low              side) of the PVC segment."      ::= { frPVCConnectEntry 7 } 
  658.  
  659.  frPVCConnectH2lOperStatus OBJECT-TYPE      SYNTAX  INTEGER {                active(1),                inactive(2),                testing(3),                unknown(4)              }      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The value of this object identifies the current              operational status of the PVC segment connection              in one direction; (i.e., in the high to low              direction).  The active state means it is              currently operational; the inactive state means it              is currently not operational; the testing state              means it is currently undergoing a test; the              unknown state means the status of it currently can              not be determined.  This value affects the PVC              status indicated across the ingress NNI/UNI (high              side) of the PVC segment."      ::= { frPVCConnectEntry 8 } 
  660.  
  661.  frPVCConnectL2hLastChange OBJECT-TYPE      SYNTAX  TimeStamp      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION 
  662.  
  663.  
  664.  
  665. Frame Relay Service MIB Working Group                          [Page 35] 
  666.  RFC 1604                Frame Relay Service MIB               March 1994 
  667.  
  668.               "The value of MIB II's sysUpTime object at the              time this PVC segment entered its current              operational state in the low to high direction.              If the current state was entered prior to the last              re-initialization of the proxy-agent, then this              object contains a zero value."      ::= { frPVCConnectEntry 9 } 
  669.  
  670.  frPVCConnectH2lLastChange OBJECT-TYPE      SYNTAX  TimeStamp      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The value of MIB II's sysUpTime object at the              time this PVC segment entered its current              operational state in the high to low direction.              If the current state was entered prior to the last              re-initialization of the proxy-agent, then this              object contains a zero value."      ::= { frPVCConnectEntry 10 } 
  671.  
  672.  frPVCConnectRowStatus OBJECT-TYPE      SYNTAX  RowStatus      MAX-ACCESS  read-create      STATUS  current      DESCRIPTION              "The status of this entry in the              frPVCConnectTable.  This variable is used to              create new connections for the PVC end-points and              to change existing connections of the PVC end-              points.  This object must be initially set to              `createAndWait'.  In this state, the agent checks              the parameters in the associated entries in the              frPVCEndptTable to verify that the PVC end-points              can be connected (i.e., the In parameters for one              PVC end-point are equal to the Out parameters for              the other PVC end-point).  This object can not be              set to `active' unless the following columnar              object exist in this row: frPVCConnectAdminStatus.              The agent also supplies the associated value of              frPVCConnectIndex for the frPVCEndptConnectIdentifier              instances.  To turn on a PVC segment connection, the              frPVCConnectAdminStatus is set to `active'."      ::= { frPVCConnectEntry 11 } 
  673.  
  674.  
  675.  
  676.  
  677.  
  678.  
  679.  
  680. Frame Relay Service MIB Working Group                          [Page 36] 
  681.  RFC 1604                Frame Relay Service MIB               March 1994 
  682.  
  683.   -- The Frame Relay Accounting Groups 
  684.  
  685.  -- The groups are the following:  --  Accounting on a PVC basis  --  Accounting on an Interface/Logical Port basis 
  686.  
  687.  -- The Accounting on a Frame Relay PVC basis Group 
  688.  
  689.  -- The accounting information is collected for a PVC  -- segment end-point. 
  690.  
  691.  frAccountPVCTable OBJECT-TYPE      SYNTAX  SEQUENCE OF FrAccountPVCEntry      MAX-ACCESS  not-accessible      STATUS  current      DESCRIPTION              "The Frame Relay Accounting PVC table.  This table              is used to perform accounting on a PVC segment              end-point basis."      ::= { frnetservObjects 6 } 
  692.  
  693.  frAccountPVCEntry OBJECT-TYPE      SYNTAX  FrAccountPVCEntry      MAX-ACCESS  not-accessible      STATUS  current      DESCRIPTION              "An entry in the Frame Relay Accounting PVC              table."      INDEX   { ifIndex, frAccountPVCDLCIIndex }      ::= { frAccountPVCTable 1 } 
  694.  
  695.  FrAccountPVCEntry ::=      SEQUENCE {          frAccountPVCDLCIIndex              Integer32,          frAccountPVCSegmentSize              Integer32,          frAccountPVCInSegments              Counter32,          frAccountPVCOutSegments              Counter32      } 
  696.  
  697.   frAccountPVCDLCIIndex OBJECT-TYPE      SYNTAX  Integer32      MAX-ACCESS  not-accessible      STATUS  current 
  698.  
  699.  
  700.  
  701. Frame Relay Service MIB Working Group                          [Page 37] 
  702.  RFC 1604                Frame Relay Service MIB               March 1994 
  703.  
  704.       DESCRIPTION              "The value of this object is equal to the DLCI              value for this PVC segment end-point."      ::= { frAccountPVCEntry 1 } 
  705.  
  706.  frAccountPVCSegmentSize OBJECT-TYPE      SYNTAX  Integer32      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The value of this object is equal to the Segment              Size for this PVC segment end-point."      ::= { frAccountPVCEntry 2 } 
  707.  
  708.  frAccountPVCInSegments OBJECT-TYPE      SYNTAX  Counter32      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The value of this object is equal to the number              of segments received by this PVC segment end-              point."      ::= { frAccountPVCEntry 3 } 
  709.  
  710.   frAccountPVCOutSegments OBJECT-TYPE      SYNTAX  Counter32      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The value of this object is equal to the number              of segments sent by this PVC segment end-point."      ::= { frAccountPVCEntry 4 } 
  711.  
  712.   -- The Accounting on a Frame Relay Logical Port basis Group 
  713.  
  714.   frAccountLportTable OBJECT-TYPE      SYNTAX  SEQUENCE OF FrAccountLportEntry      MAX-ACCESS  not-accessible      STATUS  current      DESCRIPTION              "The Frame Relay Accounting Logical Port table.              This table is used to perform accounting on a              UNI/NNI Logical Port basis."      ::= { frnetservObjects 7 } 
  715.  
  716.  frAccountLportEntry OBJECT-TYPE 
  717.  
  718.  
  719.  
  720. Frame Relay Service MIB Working Group                          [Page 38] 
  721.  RFC 1604                Frame Relay Service MIB               March 1994 
  722.  
  723.       SYNTAX  FrAccountLportEntry      MAX-ACCESS  not-accessible      STATUS  current      DESCRIPTION              "An entry in the Frame Relay Accounting Logical              Port table."      INDEX   { ifIndex }      ::= { frAccountLportTable 1 } 
  724.  
  725.  FrAccountLportEntry ::=      SEQUENCE {          frAccountLportSegmentSize              Integer32,          frAccountLportInSegments              Counter32,          frAccountLportOutSegments              Counter32      } 
  726.  
  727.   frAccountLportSegmentSize OBJECT-TYPE      SYNTAX  Integer32      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The value of this object is equal to the Segment              Size for this UNI/NNI logical port."      ::= { frAccountLportEntry 1 } 
  728.  
  729.  frAccountLportInSegments OBJECT-TYPE      SYNTAX  Counter32      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The value of this object is equal to the number              of segments received by this UNI/NNI logical              port."      ::= { frAccountLportEntry 2 } 
  730.  
  731.  frAccountLportOutSegments OBJECT-TYPE      SYNTAX  Counter32      MAX-ACCESS  read-only      STATUS  current      DESCRIPTION              "The value of this object is equal to the number              of segments sent by this UNI/NNI logical port."      ::= { frAccountLportEntry 3 } 
  732.  
  733.  
  734.  
  735.  Frame Relay Service MIB Working Group                          [Page 39] 
  736.  RFC 1604                Frame Relay Service MIB               March 1994 
  737.  
  738.   -- Frame Relay Network Service TRAPS 
  739.  
  740.  frPVCConnectStatusChange  NOTIFICATION-TYPE      OBJECTS { frPVCConnectIndex,                frPVCConnectLowIfIndex, frPVCConnectLowDLCIIndex,                frPVCConnectHighIfIndex, frPVCConnectHighDLCIIndex,                frPVCConnectL2hOperStatus, frPVCConnectH2lOperStatus,                frPVCEndptRcvdSigStatus }      STATUS  current      DESCRIPTION              "This trap indicates that the indicated PVC has              changed state.  This trap is not sent if an FR-UNI              changes state; a linkDown or linkUp trap should be              sent instead."      ::= { frnetservTraps 1 } 
  741.  
  742.   -- Conformance Information 
  743.  
  744.  frnetservConformance  OBJECT IDENTIFIER ::= { frnetservMIB 3 } 
  745.  
  746.  frnetservGroups       OBJECT IDENTIFIER ::= { frnetservConformance 1 }  frnetservCompliances  OBJECT IDENTIFIER ::= { frnetservConformance 2 } 
  747.  
  748.  -- Compliance Statements 
  749.  
  750.  frnetservCompliance MODULE-COMPLIANCE        STATUS  current        DESCRIPTION          "The compliance statement for SNMPv2 entities          which have Frame Relay Network Service Interfaces." 
  751.  
  752.        MODULE -- this module            MANDATORY-GROUPS { frnetservLportGroup,                               frnetservMgtVCSigGroup,                               frnetservPVCEndptGroup,                               frnetservPVCConnectGroup } 
  753.  
  754.            GROUP       frnetservAccountPVCGroup            DESCRIPTION                  "This group is optional for Frame Relay interfaces.                  It is                  mandatory if and only if accounting is performed                  on a PVC                  basis this                  Frame Relay interface." 
  755.  
  756.            GROUP       frnetservAccountLportGroup 
  757.  
  758.  
  759.  
  760. Frame Relay Service MIB Working Group                          [Page 40] 
  761.  RFC 1604                Frame Relay Service MIB               March 1994 
  762.  
  763.             DESCRIPTION                  "This group is optional for Frame Relay interfaces.                  It is                  mandatory if and only if accounting is                  performed on a                  logical port basis this                  Frame Relay interface." 
  764.  
  765.            OBJECT      frPVCEndptInMaxFrameSize            SYNTAX      Integer32            MIN-ACCESS  read-only            DESCRIPTION                  "Write access is not required." 
  766.  
  767.            OBJECT      frPVCEndptInBc            SYNTAX      Integer32            MIN-ACCESS  read-only            DESCRIPTION                  "Write access is not required." 
  768.  
  769.            OBJECT      frPVCEndptInBe            SYNTAX      Integer32            MIN-ACCESS  read-only            DESCRIPTION                  "Write access is not required." 
  770.  
  771.            OBJECT      frPVCEndptInCIR            SYNTAX      Integer32            MIN-ACCESS  read-only            DESCRIPTION                  "Write access is not required." 
  772.  
  773.            OBJECT      frPVCEndptOutMaxFrameSize            SYNTAX      Integer32            MIN-ACCESS  read-only            DESCRIPTION                  "Write access is not required." 
  774.  
  775.            OBJECT      frPVCEndptOutBc            SYNTAX      Integer32            MIN-ACCESS  read-only            DESCRIPTION                  "Write access is not required." 
  776.  
  777.            OBJECT      frPVCEndptOutBe            SYNTAX      Integer32            MIN-ACCESS  read-only            DESCRIPTION 
  778.  
  779.  
  780.  
  781. Frame Relay Service MIB Working Group                          [Page 41] 
  782.  RFC 1604                Frame Relay Service MIB               March 1994 
  783.  
  784.                   "Write access is not required." 
  785.  
  786.            OBJECT      frPVCEndptOutCIR            SYNTAX      Integer32            MIN-ACCESS  read-only            DESCRIPTION                  "Write access is not required." 
  787.  
  788.            OBJECT      frPVCEndptConnectIdentifier            SYNTAX      Integer32            MIN-ACCESS  read-only            DESCRIPTION                  "Write access is not required." 
  789.  
  790.            OBJECT      frPVCEndptRowStatus            SYNTAX      INTEGER { active(1) }  -- subset of RowStatus            MIN-ACCESS  read-only            DESCRIPTION                  "Write access is not required, and only one of the                  six enumerated values for the RowStatus textual                  convention need be supported, specifically:                  active(1)." 
  791.  
  792.            OBJECT      frPVCConnectAdminStatus            SYNTAX      INTEGER {                          active(1),                          inactive(2),                          testing(3)                         }            MIN-ACCESS  read-only            DESCRIPTION                  "Write access is not required." 
  793.  
  794.            OBJECT      frPVCConnectRowStatus            SYNTAX      INTEGER { active(1) }  -- subset of RowStatus            MIN-ACCESS  read-only            DESCRIPTION                  "Write access is not required." 
  795.  
  796.            OBJECT      frPVCConnectRowStatus            SYNTAX      INTEGER { active(1) }  -- subset of RowStatus            MIN-ACCESS  read-only            DESCRIPTION                  "Write access is not required, and only one of the                  six enumerated values for the RowStatus textual                  convention need be supported, specifically:                  active(1)."        ::= { frnetservCompliances 1 } 
  797.  
  798.  
  799.  
  800. Frame Relay Service MIB Working Group                          [Page 42] 
  801.  RFC 1604                Frame Relay Service MIB               March 1994 
  802.  
  803.   -- Units of Conformance 
  804.  
  805.  frnetservLportGroup  OBJECT-GROUP        OBJECTS { frLportNumPlan, frLportContact, frLportLocation,                  frLportType,                  frLportAddrDLCILen, frLportVCSigProtocol,                  frLportVCSigPointer }        STATUS  current        DESCRIPTION              "A collection of objects providing information applicable              to a Frame Relay Logical Port."        ::= { frnetservGroups 1 } 
  806.  
  807.  frnetservMgtVCSigGroup  OBJECT-GROUP        OBJECTS { frMgtVCSigProced,                  frMgtVCSigUserN391,                  frMgtVCSigUserN392,                  frMgtVCSigUserN393,                  frMgtVCSigUserT391,                  frMgtVCSigNetN392,                  frMgtVCSigNetN393,                  frMgtVCSigNetT392,                  frMgtVCSigNetnN4,                  frMgtVCSigNetnT3,                  frMgtVCSigUserLinkRelErrors,                  frMgtVCSigUserProtErrors,                  frMgtVCSigUserChanInactive,                  frMgtVCSigNetLinkRelErrors,                  frMgtVCSigNetProtErrors,                  frMgtVCSigNetChanInactive }        STATUS  current        DESCRIPTION              "A collection of objects providing information              applicable to the              Local In-Channel Signaling Procedures used for a              UNI/NNI logical port."        ::= { frnetservGroups 2 } 
  808.  
  809.  frnetservPVCEndptGroup  OBJECT-GROUP        OBJECTS { frPVCConnectIndexValue,                  frPVCEndptInMaxFrameSize, frPVCEndptInBc,                  frPVCEndptInBe, frPVCEndptInCIR,                  frPVCEndptOutMaxFrameSize, frPVCEndptOutBc,                  frPVCEndptOutBe, frPVCEndptOutCIR,                  frPVCEndptConnectIdentifier, frPVCEndptRowStatus,                  frPVCEndptRcvdSigStatus, frPVCEndptInFrames,                  frPVCEndptOutFrames, frPVCEndptInDEFrames,                  frPVCEndptInExcessFrames, frPVCEndptOutExcessFrames, 
  810.  
  811.  
  812.  
  813. Frame Relay Service MIB Working Group                          [Page 43] 
  814.  RFC 1604                Frame Relay Service MIB               March 1994 
  815.  
  816.                   frPVCEndptInDiscards,                  frPVCEndptInOctets, frPVCEndptOutOctets }        STATUS  current        DESCRIPTION              "A collection of objects providing information application              to a Frame Relay PVC end-point."        ::= { frnetservGroups 3 } 
  817.  
  818.  frnetservPVCConnectGroup  OBJECT-GROUP        OBJECTS { frPVCConnectAdminStatus, frPVCConnectL2hOperStatus,                  frPVCConnectH2lOperStatus, frPVCConnectL2hLastChange,                  frPVCConnectH2lLastChange,                  frPVCConnectRowStatus }        STATUS  current        DESCRIPTION              "A collection of objects providing information applicable              to a Frame Relay PVC connection."        ::= { frnetservGroups 4 } 
  819.  
  820.  frnetservAccountPVCGroup  OBJECT-GROUP        OBJECTS { frAccountPVCSegmentSize, frAccountPVCInSegments,                  frAccountPVCOutSegments }        STATUS  current        DESCRIPTION              "A collection of objects providing accounting              information application              to a Frame Relay PVC end-point."        ::= { frnetservGroups 5 } 
  821.  
  822.  frnetservAccountLportGroup  OBJECT-GROUP        OBJECTS { frAccountLportSegmentSize, frAccountLportInSegments,                  frAccountLportOutSegments }        STATUS  current        DESCRIPTION              "A collection of objects providing accounting              information application              to a Frame Relay logical port."        ::= { frnetservGroups 6 } 
  823.  
  824.   END 
  825.  
  826.  
  827.  
  828.  
  829.  
  830.  
  831.  
  832.  
  833.  
  834.  Frame Relay Service MIB Working Group                          [Page 44] 
  835.  RFC 1604                Frame Relay Service MIB               March 1994 
  836.  
  837.  7.  Acknowledgments 
  838.  
  839.    This document was produced jointly by the Frame Relay Forum Technical    Committee MIB Working Group and the Frame Relay Service MIB Working    Group. 
  840.  
  841. 8.  References 
  842.  
  843.    [1] Case, J., McCloghrie, K., Rose, M., and S. Waldbusser, "Structure        of Management Information for version 2 of the Simple Network        Management Protocol (SNMPv2)", RFC 1442, SNMP Research, Inc.,        Hughes LAN Systems, Dover Beach Consulting, Inc., Carnegie Mellon        University, April 1993. 
  844.  
  845.    [2] Galvin, J., and K. McCloghrie, "Administrative Model for version        2 of the Simple Network Management Protocol (SNMPv2)", RFC 1445,        Trusted Information Systems, Hughes LAN Systems, April 1993. 
  846.  
  847.    [3] Case, J., McCloghrie, K., Rose, M., and S. Waldbusser, "Protocol        Operations for version 2 of the Simple Network Management        Protocol (SNMPv2)", RFC 1448, SNMP Research, Inc., Hughes LAN        Systems, Dover Beach Consulting, Inc., Carnegie Mellon        University, April 1993. 
  848.  
  849.    [4] McCloghrie, K., and M. Rose, "Management Information Base for        Network Management of TCP/IP-based internets - MIB-II", STD 17,        RFC 1213, Hughes LAN Systems, Performance Systems International,        March 1991. 
  850.  
  851.    [5] McCloghrie, K.,  and F. Kastenholz, "Evolution of Interfaces        Group of MIB-II", RFC 1573, Hughes LAN Systems, FTP Software,        January 1994. 
  852.  
  853.    [6] Rodemann, K., "Service Management Architecture for Virtual        Connection Services", Work in Progress, July 1993. 
  854.  
  855.    [7] ANSI T1.617-1991, American National Standard for        Telecommunications - Integrated Services Digital Network (ISDN) -        Digital Subscriber Signaling System No. 1 (DSS1) - Signaling        Specification for Frame Relay Bearer Service. 
  856.  
  857.    [8] Brown, C., Baker, F., and C. Carvalho, "Management Information        Base for Frame Relay DTEs", RFC 1315, Wellfleet Communications,        Inc., Advanced Computer Communications, April 1992. 
  858.  
  859.    [9] Bradley, T., Brown, C., and A. Malis, "Multi-Protocol        Interconnect over Frame Relay", RFC 1490, Wellfleet        Communications, Inc., Ascom Timeplex, Inc., July 1993. 
  860.  
  861.  
  862.  
  863. Frame Relay Service MIB Working Group                          [Page 45] 
  864.  RFC 1604                Frame Relay Service MIB               March 1994 
  865.  
  866.  9.  Security Considerations 
  867.  
  868.    Security issues are not discussed in this memo. 
  869.  
  870. 10.  Author's Address 
  871.  
  872.    Tracy A. Brown    Bell Communications Research    331 Newman Springs Road    P.O. Box 7020    Red Bank, NJ  07701-7020     Phone: (908) 758-2107    EMail: tacox@mail.bellcore.com 
  873.  
  874.  
  875.  
  876.  
  877.  
  878.  
  879.  
  880.  
  881.  
  882.  
  883.  
  884.  
  885.  
  886.  
  887.  
  888.  
  889.  
  890.  
  891.  
  892.  
  893.  
  894.  
  895.  
  896.  
  897.  
  898.  
  899.  
  900.  
  901.  
  902.  
  903.  
  904.  
  905.  
  906.  
  907.  
  908.  
  909.  
  910. Frame Relay Service MIB Working Group                          [Page 46] 
  911.  
  912.