home *** CD-ROM | disk | FTP | other *** search
/ Groovy Bytes: Behind the Moon / groovybytes.iso / GROOVY / PPE / AEGIS / AGSLOG23.ZIP / AGSLOG.DOC < prev    next >
Encoding:
Text File  |  1995-02-19  |  5.1 KB  |  117 lines

  1.                                          _    _  _ ___ ___/\
  2.     _________/\  /\_____________/\________________ ___ _  _ \/\______________
  3.    /      _    \/   _________  /    ______________________  /   __________  /
  4.  _/     __/     \    ____)___\/     \         \_/         \/\___________  \/_
  5.  \      \        \_  \        \_     \__       \_            \_        /    /
  6.   \______\        /____________/________________/_____________/____________/kP
  7.   ·-------`------'---------------------------------------------------------·
  8.                
  9.        · ··-──────────────────────────────────────────────────────--·· ·
  10.                +  A E G i S  L o G i N  V e R S i o N  2 . 3  +
  11.        · ··-──────────────────────────────────────────────────────--·· ·
  12.                          MAiN CoDiNG - NuMBeR SiX
  13.                        iEMSi iNTeRFaCE - LoNE RuNNeR
  14.        · ··-──────────────────────────────────────────────────────--·· ·
  15.  
  16.  
  17.  FaST iNSTALL
  18.  ·-───────--·
  19.  
  20.    ■ Run iNSTALL.BAT (Hope you have an ANSI driver loaded!!)
  21.    ■ Edit iEMSi.CFG (Follow instructions!)
  22.  
  23.         
  24.         oPTiONNaL
  25.         
  26.         ■ Edit the display file if you don't like the .PCB I included :)
  27.         ■ Edit AGSLOG.CFG to make your personal config.
  28.  
  29.        
  30.        · ··-──────────────────────────────────────────────────────--·· ·
  31.  
  32.  
  33.  WHaT iS iT ?
  34.  ·-───────--·
  35.  
  36.    Well, this PPE enhance your logon with a full screen interface with iEMSi
  37.    support !
  38.  
  39.    What will happen to non-iEMSi users ? In fact, they will have a full
  40.    screen, lightbar driven login procedure with REALLY kewl ANSi graphics!
  41.    
  42.    What will happen to iEMSi users ? They will just log on your board without
  43.    entering their names or password! You will have all iEMSi informations
  44.    logged on your callers log, so you will be able to see REAL informations 
  45.    about your users !
  46.  
  47.    This feature is really K0ôL when a new user log on your BBS... As a first
  48.    time caller, only his name will be handled in the login, so he will be
  49.    able to choose between reenter his name, log on as new user or disconnect.
  50.    While he is in the logon ppe, a sysop-only window will be opened and will
  51.    show every iEMSi informations found in the iEMSi packet !! In addition, 
  52.    this windows will stay opened after he logs in as new user !
  53.  
  54.    It will be soooo easy for you now to detect people lying ! :)
  55.  
  56.    This sysop-only window offers more advantages... it shows all known
  57.    informations about the current user... When a non-iEMSi user logs in, he
  58.    will enter his name and the sysop-only window will show his location,
  59.    the date and time of his last call, his security level, his password, and,
  60.    best of all, his password input ! while HE sees only dots, YOU will see
  61.    what he is typing !
  62.  
  63.    Well, enough describing, check it out, we bet that you will keep it ! :)
  64.  
  65.    NOTE : This PPE creates a AGSLOG$.nodenumber to temporary store the
  66.    user's password. This is NOT a backdoor in ANY way ! Here is the
  67.    explanation of why this is needed :
  68.    When PCBoard ask the user for his first name, AGSLOG.PPE will run instead. 
  69.    There is no way inside AGSLOG.PPE to tell PCBoard what is the users
  70.    password, so we had to put it in a temporary file. Then AGSLOG.PPE stuff 
  71.    the users first & last names to the real prompt. When PCBoard ask for the 
  72.    last name, AGSLOGL.PPE just stuff the enter key (this is only if the user
  73.    is a one name user, if not, PCBoard doesn't ask for a lastname because 
  74.    AGSLOG.PPE already gave it). When PCBoard ask for the password, AGSLOGP.PPE 
  75.    run instead and just read the temporary file created by AGSLOG.PPE, and 
  76.    stuff the password to the real prompt. You whould say "Why AGSLOG.PPE does 
  77.    not stuuf names and password the real prompts?". It is only because with 
  78.    our method, you don't see dots while the real prompt handle the password !
  79.  
  80.        
  81.        · ··-──────────────────────────────────────────────────────--·· ·
  82.  
  83.   Version 2.3 ??
  84.   ·-─────────--·
  85.  
  86.     Bug fix from v2.2 :
  87.  
  88.    When hanging up during an iemsi session, the user had no more cursor,
  89.    because of the current color that was set to 0 (black on black!)
  90.  
  91.    Now works with Cracked Versions of Terminate that add a "." or other
  92.    stupid chars at the end of the users name.
  93.  
  94.    Iemsi system works better, because of various changes in code...
  95.  
  96.        · ··-──────────────────────────────────────────────────────--·· ·
  97.  
  98.  
  99.  PRoGRaM oVeRViEW
  100.  ·-───────────--·
  101.  
  102.    ■ Total support for IEMSI (Support for Cracked Terminate)
  103.    ■ Sysop window (Watch it, you'l love it!)
  104.    ■ Totally customizable (Did you configured ONE PPE in your life?)
  105.    ■ Kewl look and feel (Lightbar and more)
  106.    ■ TB_Q_PPE support (As usual)
  107.    ■ Login broadcast to other nodes (DesqView rulez!)
  108.    ■ Much much much (more)
  109.  
  110.        · ··-──────────────────────────────────────────────────────--·· ·
  111.  
  112.                                         · ··-─────────────────────────--·· ·
  113.                                               NuMBeR SiX & LoNE RuNNeR
  114.                                                      AEGiS'95
  115.                                         · ··-─────────────────────────--·· ·
  116.  
  117.