FWDL_RUNNING_MSG="Firmwaredownload or firmwarecommit is already running. Please wait for it to complete first."
FWRESTORE_DISALLOWED_MSG="No need to run firmwarerestore because firmware has already been committed, or there is no firmwaredownload performed."
FWRESTORE_VER_DISALLOWED_MSG="Firmwarerestore from v6.3.x to v6.1.2_cee is not supported. Please run firmwarecommit first and then download the new firmware."
IRONMANMSG="The FC4-16IP (type 31) blade is not supported by the target firmware. Please use slotshow to find out which slot it is in and remove it first."
POSITRONMSG="The FC4-48 (type 36) blade is not supported by the target firmware. Please use slotshow to find out which slot it is in and remove it first."
SCIMITARMSG="The FA4-18 (type 33) blade is not supported by the target firmware. Please use slotshow to find out which slot it is in and remove it first."
SABREMSG="This platform is not supported by the target firmware. Please try to download another firmware."
XENONMSG="The FC10-6 (type 39) blade is not supported by the target firmware. Please use slotshow to find out which slot it is in and remove it first."
TRITONMSG="The FC8-48 (type 51) blade is not supported by the target firmware. Please use slotshow to find out which slot it is in and remove it first."
LARISSAMSG="The FC8-32 (type 55) is not supported by the target firmware. Please use slotshow to find out which slot it is in and remove it first."
DESPINAMSG="The FC8-16 (type 37) is not supported by the target firmware. Please use slotshow to find out which slot it is in and remove it first."
MACEMSG="This platform is not supported by the target firmware. Please try to download another firmware."
LANCEMSG="The FS8-18 (type 43) blade is not supported by the target firmware. Please use slotshow to find out which slot it is in and remove it first."
EUROPAMSG="The FCOE10-24 (type 74) blade is not supported by the target firmware. Please use slotshow to find out which slot it is in and remove it first."
STRIKERMSG="The FX8-24 (type 75) blade is not supported by the target firmware. Please use slotshow to find out which slot it is in and remove it first."
ADSPOLICYMSG="ADS policy of Access Gateway is enabled. Please use \"ag --policydisable ads\" to remedy this."
UNSUPPORTED_DL_VERMSG="Cannot downgrade to 6.1 or lower. Please downgrade to 6.2 first and then download the desired firmware version."
UNSUPPORTED_UP_VERMSG="Cannot upgrade directly to 6.3. Please upgrade to 6.2 first and then upgrade to 6.3."
UNSUPPORTED_VF_DISABLE_MSG="Downgrade is not allowed because VF is enabled. Please run \"lscfg --config\" and \"lscfg --delete\" commands to remove the non-default LS first, then run \"fosconfig --disable vf\" to disable VF before proceeding."
UNSUPPORTED_ETHSW_DISABLE_MSG="Downgrade is not allowed because Ethernet Switch Service is enabled. Please run \"fosconfig --disable ethsw\" command to disable it before proceeding."
UNSUPPORTED_AG_ON_SPIRIT_MSG="Downgrade is not allowed because AG is enabled. Please run \"ag --modedisable\" command to disable AG mode before proceeding."
UNSUPPORTED_AG_ON_MACE_MSG="Downgrade is not allowed because AG is enabled. Please run \"ag --modedisable\" command to disable AG mode before proceeding."
UNSUPPORTED_AG_ON_ELARA_MSG="Downgrade is not allowed because AG is enabled. Please run \"ag --modedisable\" command to disable AG mode before proceeding."
AG_QOS_PORT_ACTIVE_MSG="Downgrade is not allowed because one or more ports are in active QoS(AoQ) mode. Please use \"portdisable [slot/]port\" command to disable the ports in active QoS mode."
QOS_DI_ZONE_EXISTANCE_MSG="Downgrade is not allowed because defined and/or active configurations have QoS DI zones in one or more contexts. Please use \"zonedelete zone_name\" command to delete the QoS DI Zones before proceeding."
AGPGMODESMSG="One or more port groups are operating in a special mode (lb, mfnm, etc). Please use \"ag --pgdelmodes\" to remedy this."
PID_CORE_MSG="PID Format needs to be set to Core. Please use \"switchdisable\" to disable the switch then use \"configure\" to change the Switch PID Format."
PERF_MSG="Upgrade is not allowed because both Top talker monitors and FC Router are configured and the new firmware doesn't support co-existence of both the features. Pleae use \"perfttmon --del\" or \"fosconfig --disable fcr\" commands to delete top talkers or disable FC Router feature before upgrading."
METEORPLATFORMMSG="Cannot upgrade to firmware v6.1. This firmware does not support Silkworm 24000 platform."
NON_ENC_PLATFORMMSG="This platform is not supported by the target firmware. Please try to download another firmware."
UNSUPPORTEDPLATFORMMSG="Cannot download the requested firmware because the firmware doesn't support this platform. Please enter another firmware path."
TACONFIGUREDMSG="Downgrade is not allowed because one or more trunk areas have been configured. Please use \"porttrunkarea --disable\" to disable trunk areas before downgrading."
CRRECOVCONFIGUREDMSG="Downgrade is not allowed because one or more ports have credit recovery enabled. Please use \"islshow\" to show ports with credit recovery. Use the command \"portdisable\" to disable credit recovery ports."
LSANMATRIXMSG="Firmware to downgrade does not support the FCR matrix. Please use the fcrlsanmatrix CLI command to put the FCR matrix configuration back to default since this feature will not be supported in the older firmware."
TEMPLICENSEPRESENT="Temporary license is present on the switch. Please remove that before performing firmware downgrade."
AGTRUNKCONFIGUREDMSG="One or more N_Port trunks are enabled. Downgrade is not allowed because one or more trunk areas have been configured on the switch attached to this AG. Please execute \"porttrunkarea --disable\" CLI on the attached switch to remedy this."
DOWNGRADEWITHC2EX="One or more Integrated Routing EX_Ports are enabled. Please use \"portcfgexport\" CLI to disable these ports before continuing."
DOWNGRADEWITH7500EMSG="7500E platform is not supported by the target firmware. Please try to download another firmware version. 7500E requires FOS V6.1.1 or higher."
MAXFCPORTSEXCEEDED_7500EMSG="Exceeded maximum number of FC ports for 7500E configuration. Only FC ports 0 and 1 are allowed to be used for 7500E. Please use \"portcfgpersistentdisable\" to persistently disable all remaining FC ports and try again, or install the 7500E Upgrade License."
MAXTUNNELEXCEEDED_7500EMSG="Exceeded maximum number of tunnels for 7500E configuration. Only 1 FCIP tunnel configuration allowed per GE port. Please use \"portcfg fciptunnel\" or \"portcfgdefault\" to remove any extra tunnel configurations and try again, or install the 7500E Upgrade License."
MAXBANDWIDTHEXCEEDED_7500EMSG="Exceeded maximum bandwidth allocation for 7500E configuration. Minimum bandwidth is 1400 and maximum bandwidth is 50000 (50Mbps). Please use \"portcfg fciptunnel\" or \"portcfgdefault\" to set a commited rate in range for all FCIP tunnels and try again, or install the 7500E Upgrade License."
FCIPTAPEACC_7500EMSG="The 7500E does not support the tape pipelining feature. This is only available via upgrade license. Please use \"portcfg fciptunnel\" or \"portcfgdefault\" to remove the tape pipelining funcionality for all FCIP tunnels and try again, or install the 7500E Upgrade License."
FCIPIPSEC_7500EMSG="The 7500E does not support the IPSec feature. This is only available via upgrade license. Please use \"portcfg fciptunnel\" or \"portcfgdefault\" to remove all IPSec policies from the FCIP tunnels and try again, or install the 7500E Upgrade License."
FCIPFICON_7500EMSG="The 7500E does not support FICON emulation. This is only available via upgrade license. Please use \"portcfg ficon\" or \"portcfgdefault\" to remove any FICON tunnels and try again, or install the 7500E Upgrade License."
DOWNGRADE_WITH_C2_PORT_MIRROR="Downgrade is not allowed because port mirroring is enabled for one or more ports. Please use \"portcfg mirrorport\" and \"portmirror --show in Default and in all Logical switches (if any)\" to disable them before downgrading"
TIFCRCONFIGUREDMSG="Downgrade is not allowed because one or more TI over FCR zones have been configured. Please use \"zone --remove\" or \"zone --delete\" to remove/delete them before downgrading."
IOD_DELAY_CONFIGURED="Downgrade is not allowed because IOD Delay value is configured for one or more domains. Please use \"ioddelayshow and ioddelayreset\" to disable them before downgrading."
RDINTEROP2CONFIGUREDMSG="Downgrade is not allowed because Frame Redirect zones are configured with McDATA Interop Mode enabled. Use \"interopmode\" and/or \"zone --rddelete\" commands."
RDINTEROP3CONFIGUREDMSG="Downgrade is not allowed because Frame Redirect zones are configured with McDATA Open Mode enabled. Use \"interopmode\" and/or use \"zone --rddelete\" commands to remove/delete them before downgrading."
DOMOFFSETINTEROPCONFIGMSG="Downgrade is not allowed because McDATA/OpenMcData Mode is enabled and domain offset is not configured to default McDATA/OpenMcData offset. Use \"interopmode\" command to remove/delete/reconfigure/modify them before downgrading."
MSFRZONEORCFGNAMEFOUNDMSG="Upgrade is not allowed because one of the Zones or configs defined on this switch is using a reserved naming prefix \"msfr_zn\" or \"msfr_cfg\" please rename them before upgrading."
SWITCH_FAULTY_MSG="Firmwaredownload is not allowed since the switchState is Faulty. Use \"switchShow\" to see the switch state. Please recover the switch before proceeding."
AG_QOS_PORT_ACTIVE_FABRIC_SIDE_MSG="Downgrade is not allowed because one or more F-ports on the switch are connected to AG (with active QoS). Please use \"portdisable [slot/]port\" command to disable those F-ports."
UNSUPPORTED_PERSISTENT_ALPA_ON_DOWNGRADE="Downgrade is not allowed because persistent alpa in enabled. Please use \"ag --persistentalpaenable 0\" to disable the feature before downgrading."
UNSUPPORTED_SFLOW_ON_DOWNGRADE="Downgrade is not allowed because sflow is enabled in startup/running config. Please use \"show running-config/show-startup-config\" to check sflow config and remove them before downgrading."
UNSUPPORTED_DOT1X_ON_DOWNGRADE="Downgrade is not allowed because dot1x is enabled in startup/running config. Please use \"show running-config/show-startup-config\" to check dot1x config and remove them before downgrading."
UNSUPPORTED_SYSTEMCARD_FEATURE_ON_DOWNGRADE="Downgrade is not allowed because System Card is enabled. Please use \"cryptocfg --set -systemcard disable\" to disable System Card feature before downgrading."
UNSUPPORTED_QOURUMCARD_SIZE_NON_ZERO="Downgrade is not allowed because Qourum size is greater than zero. Please change the qourum size to zero before downgrading."
UNSUPPORTED_TWO_RKM_KVS_UPGRADE="Upgrade is not allowed because Secondary RKM KV is registered. Please use \"cryptocfg --dereg -keyvault <label> \" to deregister the secondary KV and then try again."
UNSUPPORTED_TWO_SKM_KVS_DOWNGRADE="Downgrade is not allowed because Secondary SKM KV is registered. Please use \"cryptocfg --dereg -keyvault <label> \" to deregister the secondary KV and then try again."
AREA_ASSIGNED_BEYND_MAXPHPORTS="Downgrade is not allowed because one or more of the areas assigned is greater than the maximum number of physical ports on the platform. Please user \"portaddress --show\" to display the areas currently assigned and \"--unbind and --bind\" to bind an area below max_phy_ports".
UNSUPPORTED_PASSWDCFG_HISTORY_VALUE="Downgrade is not allowed because passwdcfg.history value of 0 is not supported. Please set the history value in a range of 1 - 24 before downgrading."
UNSUPPORTED_PORTFENCING_STATECHANGEMSG="Portfencing is enabled for State Change events. Kindly disable before downgrade"
XFCIP_IPSEC_MSG="IPSec on FCIP tunnels for 7800 require version v6.3.1 or higher. Please use \"portcfg fciptunnel\" to disable IPSec for all FCIP tunnels and try again."
XFCIP_VLAN_TAGGING_MSG="VLAN Tagging on FCIP tunnels for 7800/FX8-24 requires version v6.3.1 or higher. Please use \"portcfg fcipcircuit <VE-Port> modify\" to disable VLAN Tagging on all FCIP Circuits."
WEBLINKER_MSG="Both http and Secure http are disabled. Please use \"webdconfigure\" command to enable http."