  1. 04 April, 2000
  2. Cris Lungu
  3.  
  4. Ambient conditions: temperature 21 C, atmospheric pressure 30 in Hg.
  5. Velocity sensor type: hotwire.
  6. Nominal centerline velocity: 200 FPM
  7.  
  8.                                 Velocity [FPM]
  9. Position [mm]                noinlet                    inlet
  10. 20                        151                        179
  11. 25                        157                        180
  12. 30                        173                        184
  13. 35                        178                        189
  14. 40                        180                        190
  15. 45                        183                        192
  16. 50                        188                        193
  17. 55                        189                        194
  18. 60                        190                        194
  19. 65                        191                        195
  20. 70                        194                        196
  21. 75                        197                        198
  22. 80                        199                        202
  23. 85                        202                        205
  24. 90                        205                        207
  25. 95 *                         206                        210
  26. 100                        204                        208
  27.  
  28. Note: Due to the fluctuations of velocity at any given point the data 
  29. presented above is the average of maximum and minimum readings.
  30. * This point represents approximately half of the distance between the 
  31. walls.