home *** CD-ROM | disk | FTP | other *** search
/ ftp.ee.pdx.edu / 2014.02.ftp.ee.pdx.edu.tar / ftp.ee.pdx.edu / pub / users / gerry / ME449 / velocityProfiles / 2000 / p9_noinlet_pitot.dat < prev    next >
Text File  |  2000-04-07  |  1KB  |  31 lines

  1. Group John Weijland, Jim Brossard, Dave Tow
  2. we did 700 fpm flow because we could not accurately damp down the system. We
  3. started with the pitot tube at the far wall where it was .2" away from the wall.
  4. Our pascal measuring meter was at 6.9 pa with no pressure so 6.9 will have to be
  5. subtracted from all values for delta P (could this instrument be sensitive to
  6. barometric changes after calibration?)
  7.  
  8. Distance from far wall        Pressure reading
  9. .2                9.1
  10. .6                9.4
  11. 1.0                9.2
  12. 1.4                9.2
  13. 1.8                9.2
  14. 2.2                9.2
  15. 2.6                9.1
  16. 3.0                8.9
  17. 3.4                8.9
  18. 3.8                8.6
  19. 4.2                8.3
  20. 4.6                7.9
  21. 5.0                7.7
  22. 5.4                7.8
  23.  
  24. After traversing the tunnel we took three readings: far side, middle and near
  25. side which were respectively 8.5,8.4,9.1 which don't correspond with our
  26. readings for smaller steps. I calculated the pressure we were looking for was
  27. 2.19 Pa so after subtracting 6.9 from all of them the values seem reasonable is
  28. the meter was reading in Pa. I calculated the Reynolds number at 49539 and
  29. entrance effect length at 17.7 ft.