home *** CD-ROM | disk | FTP | other *** search
/ Frostbyte's 1980s DOS Shareware Collection / floppyshareware.zip / floppyshareware / GLEN / ELCODE1.ZIP / MANUAL.DOC < prev    next >
Text File  |  1988-09-29  |  6KB  |  319 lines

  1.  
  2.  
  3.  
  4.  
  5.  
  6.  
  7.  
  8.  
  9.  
  10.  
  11.  
  12.  
  13.                THE ELECTRICAL REFERENCE DATA BASE
  14.  
  15.  
  16.                                by
  17.  
  18.  
  19.                          FUTURE SYSTEMS
  20.                       2306 STONEMILL CT. 
  21.                        RICHMOND,VA.,23233
  22.  
  23.  
  24.  
  25.  
  26.  
  27.                             (C) 1988
  28.  
  29.  
  30.  
  31.  
  32.  
  33.  
  34.  
  35.  
  36.  
  37.  
  38.  
  39.  
  40.  
  41.  
  42.  
  43.  
  44.  
  45.                 AUTHOR: David L. Lemaster, P.E.
  46.  
  47.  
  48.  
  49.  
  50.  
  51.  
  52.  
  53.  
  54.  
  55.  
  56.  
  57.  
  58.  
  59.  
  60.  
  61.  
  62.  
  63.  
  64.  
  65.  
  66.  
  67.  
  68.  
  69.  
  70.  
  71.  
  72.  
  73.                                                     4/1/88
  74.  
  75.   The ELECTRICAL REFERENCE DATA BASE is copyrighted. The program
  76. is shareware, and can be freely copied for trial use by others
  77. on a PRIVATE NON-COMERCIAL BASIS.
  78.  
  79.   Acceptance and use of this software is your acknowledgement
  80. that you realize that this software may not suit your
  81. requirements and may not be completely trouble-free.
  82.  
  83.   The information referenced in this software was derived from
  84. The National Electrical Code ( (c) 1984 , National Fire
  85. Protection Association, Quincy,Massachusetts 02269 ).The
  86. information is not the complete and official position of the
  87. NFPA on any subject covered in this program.
  88.  
  89.   If the following startup instructions are followed, this
  90. software will perform as described.
  91.  
  92.   Future Systems assumes no liability for the use of this
  93. software, the interpetation of the enclosed data, the
  94. applications of the data contained, or the accuracy of the data
  95. herein.
  96.  
  97.   As a user you are forbidden to distribute this software or any
  98. future updates in connection with any other product or service,
  99. or as part of a corporate or institutionally sponsored
  100. distribution.
  101.  
  102.   Future updates and registration of this software are available
  103. from Future Systems for a fee of $45.00 per update.Send check or
  104. money order to:
  105.                
  106.  
  107.                          Future Systems
  108.                        2306 Stonemill Ct.
  109.                       Richmond, Va.,23233
  110.  
  111.  
  112.  
  113.  
  114.  
  115.  
  116.  
  117.  
  118.  
  119.  
  120.  
  121.  
  122.  
  123.  
  124.  
  125.  
  126.  
  127.                         PAGE 1
  128.  
  129.  
  130.  
  131.  
  132.  
  133.  
  134.  
  135.  
  136.  
  137.  
  138.  
  139.  
  140.  
  141. PURPOSE:
  142.  
  143.   This data base was designed out of necessity.The information
  144. contained is used by design electrical engineers and technicians
  145. almost daily.Use this data base as a tool - not as a replacement
  146. for the NEC manual!!
  147.  
  148.  
  149.  
  150.  
  151.  
  152.  
  153.  
  154. THE INFORMATION CONTAINED:
  155.  
  156.   1. D.C. MOTORS 
  157.   2. SINGLE PHASE MOTORS
  158.   3. THREE PHASE INDUCTION MOTORS
  159.   4. THREE PHASE WOUND ROTOR MOTORS
  160.   5. THREE PHASE SYNCHRONOUS MOTORS
  161.  
  162.   The above data bases provide information as to full load
  163. currents, motor over current protection rating, the size or
  164. guage of the wire required to connect one motor of that
  165. particular horsepower in a general purpose application, the
  166. conduit trade size required to house the wire, the NEMA size
  167. starter recommended,the amperage and the recommended fusing.
  168.  
  169.  
  170.   6.NEMA DATA
  171.   
  172.   This data base is a listing of the NEMA code letters and their
  173. related locked rotor KVA per horsepower,maximum rating or
  174. setting of motor branch circuit protective devices,NEMA size
  175. starters,Hazardous (classified) locations, and NEMA type
  176. enclosures for starters.
  177.  
  178.   7.MOTOR FRAME SIZES
  179.  
  180.   Three phase frame sizes for open and totally enclosed,fan
  181. cooled motors for general purpose are listed in a data base.
  182.  
  183.   8.THREE PHASE CONDUCTORS AMPACITIES
  184.  
  185.   This data base covers the wire guages #18 to 2000 MCM and
  186. commonly used types of not more than three conductors in a
  187. raceway etc.
  188.  
  189.   
  190.  
  191.  
  192.  
  193.  
  194.                         PAGE 2
  195.  
  196.  
  197.  
  198.  
  199.  
  200.  
  201.  
  202.  
  203.  
  204.  
  205.  
  206.  
  207.  
  208.  
  209.  
  210.   9.SINGLE PHASE CONDUCTOR AMPACITIES
  211.  
  212.  
  213.   10.MAXIMUM CONDUCTORS IN CONDUIT
  214.  
  215.  
  216.   11.THREE PHASE TRANSFORMERS
  217.  
  218.    This data base contains the full load currents for three
  219. phase transformers at various line to line voltages.
  220.  
  221.  
  222.   12.RECOMMENDED COPPER WIRE AND TRANSFORMER SIZES
  223.  
  224.    This data base provides the maximum recommened distances
  225. between a motor and transformer .
  226.  
  227.  
  228.   13.FILE RECOVERY MENU
  229.  
  230.      This is a submenu that provides a utility to recover those
  231. lost data files.
  232.  
  233.  
  234.  
  235. ---------------------------------------------------------------
  236.  
  237.  
  238.   All of the above data bases contain a note area for those
  239. reminders that designers like to note.All notes in each data
  240. base are saved in that data base and become a part of it.
  241.  
  242.  
  243.  
  244.  
  245.  
  246.  
  247.  
  248.  
  249.  
  250.                               PAGE 3
  251.  
  252.  
  253.  
  254.  
  255.  
  256.  
  257.  
  258.  
  259.  
  260.  
  261.  
  262.  
  263.  
  264.  
  265.  
  266.  
  267.  
  268.  
  269.  
  270.                     HOW TO RUN THIS SOFTWARE
  271.  
  272.  
  273. PLEASE MAKE A BACKUP COPY OF EACH DISK BEFORE PROCEEDING!!!!!!!
  274.  
  275.  
  276.  
  277.   First you must have a hard disk drive !
  278.   Secondly, you must be using DOS 3.0 or better.
  279.   
  280.   Create a directory called MOTORS or whatever you choose.
  281.   Change to that directory.
  282.   Make the hard drive your default drive.
  283.   Insert each disk into drive A and type "COPY A:*.*".
  284.   After all of the disks have been loaded, type "run".
  285.  
  286.   If this is the first time that you are running this program
  287.   you will have to run the program "yoursys.com" to configure
  288.   the software to your particular computer.After this is done,
  289.   type "run" one more time.
  290.  
  291.  
  292.  
  293.  
  294.  
  295.                   WHAT SHOWS UP ON YOUR SCREEN
  296.  
  297.  
  298.   The first screen is the data base menu. Make a selection and
  299. see what you get! Press the "?" key for help. This will explain
  300. the selection of functions available and what they do.
  301.  
  302.   If an area is displayed that says "NOTES:", this is your area
  303. to make entries. To enter a note press "A" for add. To edit a
  304. note, press "E" for edit--very complicated! It may be necessary
  305. to use the (+) key to select file #2 to make note entries in
  306. some cases.
  307.  
  308.   IF you select "D" and delete your note - TOO BAD - it's gone!!
  309.  
  310.   
  311. ****************************************************************
  312. ****************************************************************
  313.  
  314.                                 PAGE 4
  315.  
  316.  