  1. ********************   T U R B O  D L D(r)   **********************
  2. **********************    VERSION  2.0    *************************
  3.  
  4.      Copyright (c) 1990-94  Panacea Inc. - All Rights Reserved
  5.  
  6.  
  7. This is the READ.ME file for TurboDLD v2.0 It contains
  8. information that has changed or is different from the Installation
  9. Guide, as well as some other useful tips.
  10.  
  11.  
  12. I. TIPS/ERRATA/FEATURES/REVISIONS
  13. ============================================================
  14.  
  15. Support for AutoCAD R12/Windows
  16. -------------------------------
  17.  
  18. This version of TurboDLD is designed to specifically support DOS
  19. versions of AutoCAD 10/386, 11/386 and 12. Panacea is currently
  20. developing a driver which will support AutoCAD for Windows.
  21. Registered users of TurboDLD will be notified when this driver is
  22. available.
  23.  
  24.  
  25.  
  26. AutoCAD Release 10/386 & Release 11 Limitations
  27. -----------------------------------------------
  28. TurboDLD has the following limitations when installed for use with
  29. AutoCAD Release 10/386 & Release 11:
  30.      
  31.       1. Cannot use the "Text Window on Single" Pop-up Text Window.
  32.       
  33.       2. Due to the manner in which AutoCAD Release 10/386 works,
  34.      the TurboDLD function DLDBPMODE, as well as the MACH-12 
  35.      compatible ZI, ZO commands are not currently supported in 
  36.      this TurboDLD release when using AutoCAD Release 10/386.
  37.  
  38.  
  39. Font Selection          
  40. ---------------
  41.    TurboDLD includes an array of fonts for AutoCAD menus and dialogs.
  42.    In addition to the Panacea supplied fonts, TurboDLD also supports 
  43.    .BDF fonts. Primarily for foreign AutoCAD support. .BDF fonts are 
  44.    usually public domain and are easily available through Shareware.
  45.    AutoCAD Release 12 includes various .BDF fonts
  46.  
  47.    Please note that .BDF fonts are not supported for XGA and 8514/A
  48.    graphics boards. Only Panacea supplied fonts are available those 
  49.    boards.
  50.  
  51.  
  52.    Enabling .BDF Fonts
  53.    -------------------
  54.    In order to enable .BDF font support in TurboDLD, you must either
  55.    start AutoCAD from your main AutoCAD sub-directory, or set the DLDFONT 
  56.    environment variable prior to starting AutoCAD. Syntax of DLDFONT is:
  57.  
  58.         SET DLDFONT = {FONTDIR}
  59.  
  60.    where {FONTDIR} is the full path name to the sub-directory which 
  61.    contains the .BDF fonts.
  62.  
  63.    If DLDFONT is not set, TurboDLD will look for a \DRV directory
  64.    off of the default AutoCAD directory. If no .BDF fonts are found
  65.    in the DRV directory, then only Panacea supplied font options 
  66.    will be available.
  67.  
  68.  
  69.    Choosing .BDF Fonts 
  70.    -------------------
  71.    To use a .BDF font in TurboDLD, choose the Basic Configuration menu
  72.    "Select Font From List" option to display a list of available fonts.
  73.    The list will contain available fonts, limited by the settings of the
  74.    DLDFONT environment variable and the font filter chosen in the Basic 
  75.    Configuration menu Select Font Filter option.
  76.    
  77.    
  78.    Limiting Font Selections
  79.    ------------------------
  80.    If you have many .BDF fonts on your system and you wish to select only 
  81.    a certain style of font, TurboDLD offers a filtering mechanism to allow 
  82.    you to select only a certain types of fonts based on their internal
  83.    CHARSET_REGISTRY name or Code Page definition. 
  84.    
  85.    To select a specific .BDF font type, from the Basic Configuration menu, 
  86.    use the Select Font Filer option and then select an available .BDF font 
  87.    type. If you wish to see all installed fonts, choosse All Fonts. Your 
  88.    font filter will be in effect when you select the Select Font Filter 
  89.    menu option.
  90.  
  91.  
  92. Graphics Mode Text Window          
  93. --------------------------
  94.  
  95. Please note that the Text window on graphics screen works with AutoCAD 
  96. Release 12 only.
  97.  
  98.  
  99.    Text Window Caveats
  100.    -------------------
  101.     
  102.     RCONFIG
  103.     -------
  104.     If TurboDLD is configured for "Text Window on Single" and
  105.     RCONFIG is used to configure AVE Render, you may have problems
  106.     selecting menu items. If this happens, type CTRL-C to exit
  107.     RCONFIG and return to the AutoCAD drawing editor. Then 
  108.     reconfigure TurboDLD for "Single" screen operation and 
  109.     then run RCONFIG again.
  110.  
  111.     Random Characters in Menu Areas
  112.     --------------------------------
  113.     On some graphics boards, when TurboDLD is configured for "Text 
  114.     Window on Single" random characters characters may appear in the 
  115.     AutoCAD menu areas. If this occurs, configure TurboDLD for "Single"
  116.     screen mode. Do not continue to use the text window, unpredictable 
  117.     results may occur.
  118.  
  119.     Networked AutoCAD Installations
  120.     -------------------------------
  121.     On a networked AutoCAD Release 12 system, if the maximum number
  122.     of users is reached, an alert dialog box is displayed. When
  123.     using TurboDLD in the "Single" screen mode an abnormal AutoCAD
  124.     termination may occur instead of the alert dialog box. If you 
  125.     think this may be a problem, configure TurboDLD for the "Text 
  126.     Window on Single" option.
  127.  
  128.  
  129.     WCEdit
  130.     ------
  131.     Elsa's WCEdit utility may appear to hang when TurboDLD is 
  132.     configured for the "Text Window on Single" mode. In fact, WCEdit
  133.     has not hung - instead it is waiting for user input. When the
  134.     TurboDLD text window is enabled, WCEdit still thinks TurboDLD
  135.     is in a text-mode screen and tries to write directly to it. This
  136.     will not work. Press Ctrl-X to return to AutoCAD from WCEdit.
  137.     If you wish to use WCEdit with TurboDLD, configure for "Single"
  138.     screen mode.
  139.  
  140.  
  141. AutoCAD Command Line Cursor          
  142. ---------------------------
  143.       
  144. A "-" cursor has been added to the AutoCAD Command line to identify the
  145. current AutoCAD cursor location.
  146.  
  147.  
  148.  
  149. Graphics Platform Specific Problems
  150. -----------------------------------
  151.  
  152.     XGA
  153.     ---
  154.     If you are using an original XGA, it is perfectly normal to see the
  155.     following message come up under AutoCAD and 3D Studio:
  156.  
  157.             DMQS Not Found!
  158.  
  159.     If you have an XGA-2 and this message comes up, it means that you
  160.     have either not properly installed the board, or not properly installed
  161.     the DMQS software that should have come with your board.
  162.  
  163.     
  164.     XGA & IIT AGX
  165.     -------------
  166.     This version of TurboDLD does not support boards using either IBM XGA
  167.     chips or IIT's AGX chips in 16 color modes. Use the 256 color modes
  168.     instead.
  169.     
  170.  
  171.     S3-based Graphics Boards
  172.     ------------------------
  173.     The 24-bit modes (16 million colors) for some S3 boards are not
  174.     supported in this TurboDLD release.
  175.  
  176.     
  177.     TIGA-based Graphics Boards
  178.     --------------------------
  179.     If you are using AutoCAD 10/386, it will be necessary to run the 
  180.     AutoCAD 11 NEWDX.EXE utility to update the Phar Lap DOS extender to 
  181.     run properly with TurboDLD.
  182.  
  183.      
  184.        NEC Multisync Graphics Engine
  185.        -----------------------------
  186.        NEC Multisync Graphics Engine based TIGA boards may leave errant 
  187.        crosshairs on the screen under dialog boxes, menus and with the 
  188.        spy glass. Also, selecting fonts other than the default for the MGE 
  189.        may cause unpredictable results.
  190.  
  191.        When configuring for an NEC Multi Graphics Engine, add the following
  192.        line to the DLDSETUP.DAT file created by the TurboDLD setup program.
  193.  
  194.           TIGA REINIT
  195.  
  196.        The above line may be placed anywhere in the file provided it is not 
  197.        preceded by a ;. This will reinitialize the graphics screen when 
  198.        returning from a flip screen.
  199.  
  200.  
  201.     Weitek P9000
  202.     ------------
  203.     With P9000-based graphics boards, erasing small objects or moving many
  204.     objects may result in stray pixels being left on the screen. Issue a 
  205.     REDRAW to remove them from the screen.
  206.  
  207.  
  208.     ATI VGA Wonder
  209.     --------------
  210.     When using some ATI VGA Wonder boards in a dual screen system 
  211.     configured for single screen use, make sure that you start
  212.     AutoCAD from the VGA screen. Otherwise, flip screens will result
  213.     in a weird combination of monochrome and VGA screens. 
  214.  
  215.     
  216.     Monochrome Dual Screen Configurations
  217.     -------------------------------------
  218.     When using a monochrome display in a dual screen configuration it may
  219.     be necessary to start AutoCAD from the monochrome screen instead of
  220.     the graphics screen. This is especially true in cases where the 
  221.     graphics display board also has a VGA chip on-board. To switch to
  222.     the monochrome screen type: 
  223.     
  224.         MODE MONO 
  225.     
  226.     at the DOS prompt. To switch back to the graphics screen, type: 
  227.     
  228.         MODE CO80
  229.     
  230.     You may also add these commands to your AutoCAD start-up file for 
  231.     automatic execution.
  232.  
  233.  
  234.  
  235. 3D Studio
  236. ---------
  237.  
  238. In 3D Studio v3, selection of a display font larger than 8x14 at 
  239. 640x480 resolution will cause 3D Studio to display a blank screen
  240. which you cannot recover from. This is a limitation of 3D Studio.
  241. If a blank screen occurs, delete 3DADI.CFG and then reconfigure
  242. TurboDLD for an 8x14 or smaller font.
  243.  
  244.  
  245. If using a TIGA graphics board with 3D Studio, we highly recommend
  246. that you configure your display and rendering resolutions to be the
  247. same. Some TIGA boards don't cope well with mode switches in the 
  248. 3DS environment.
  249.  
  250.  
  251. When configuring 3D Studio for use with TurboDLD and XGA or P9000
  252. based graphics boards, answer "N" to the "Are you using a VGA
  253. graphics board?" configuration question or unpredictable results
  254. will occur. 
  255.  
  256.  
  257. The PANA3DS.BAT file copied to your TurboDLD sub-directory during 
  258. installation is used for 3D Studio configuration. This file should 
  259. be run prior to starting 3D Studio.
  260.  
  261.  
  262.  
  263. DLDCFG and AutoCAD Release 12
  264. -----------------------------
  265.  
  266. The DLDCFG environment variable is used by TurboDLD to locate its
  267. configuration files. DLDCFG must be set for AutoCAD Release 10/386,
  268. Release 11, AutoShade, and 3D Studio.
  269.  
  270. When using Release 12, however, DLDCFG is not required. TurboDLD
  271. will look for its configuration files in the same directory as the
  272. RCTURBOD.EXP file. However, if DLDCFG is set, TurboDLD will use
  273. DLDCFG to locate its configuration files. This could be useful in
  274. a networked environment to allow individual users of a network-based
  275. version of TurboDLD to maintain their own local TurboDLD configuration.
  276.  
  277.  
  278.  
  279. Upgrading from DLD386 or MACH-12
  280. --------------------------------
  281.  
  282. If you are using Release 12, you do not need to run DLD386's
  283. FASTACAD.BAT first. FASTACAD.BAT sets four environment variables
  284. including DLDCFG, DSPADI, RDPADI, and RCPADI. None of these
  285. environment variables are needed with Release 12 and TurboDLD. If
  286. you set these variables in your AUTOEXEC.BAT or a batch file used
  287. to start Release 12, we strongly recommend that you remove them.
  288.  
  289.  
  290. General Information 
  291. -------------------
  292. If you have low amounts of CPU RAM and less than 20mb of available
  293. hard disk space you should use the -SWAPCHK ON switch to configure
  294. AutoCAD. This switch will give you the option of saving your
  295. drawing when AutoCAD runs out of swap space.   The way you
  296. configure this is to change into your AutoCAD program sub-directory
  297. and at the prompt type:
  298.  
  299.         CFIG386 ACAD -SWAPCHK ON
  300.  
  301.  
  302.  
  303.     AutoCAD Revisions
  304.     -----------------
  305.     Please be aware that there is a C2 revision to AutoCAD Release 12.
  306.     This revision corrects various digitizer and plotter problems.
  307.  
  308.  
  309.     Rendering Resolution Options 
  310.     ----------------------------
  311.     The Rendering screen configuration menu will be available only when
  312.     configuring the Rendering screens of AVE Render, AutoShade 2 with 
  313.     RenderMan or 3D Studio.
  314.     
  315.     Also note that TurboDLD is a combined Display/Rendering driver
  316.     therefore, you should select that option from AVE Render's
  317.     configuration menu.
  318.  
  319.  
  320.     Graphics Board Selection
  321.     ------------------------
  322.     If your graphics board is not listed in the Graphics Board Selection
  323.     menu and you know which chip or platform your board is based on, you
  324.     may choose the Generic selection for that chip type. If you are not
  325.     sure which platform your graphics board is based on, please refer to
  326.     your user's manual or contact the board manufacturer for more
  327.     information.
  328.  
  329.  
  330.     Dialog Commands
  331.     ---------------
  332.     If the AutoCAD Release 12 file and command dialog box usage is 
  333.     disabled (i.e. setting CMDIA = 0 and FILEDIA = 0 ) and a drawing
  334.     with an unresolved XREF is opened from the text screen, an error
  335.     or system hang will occur. This is a bug with AutoCAD and ADI 
  336.     drivers. To avoid this, use the Text Window on Single configuration
  337.     option.
  338.  
  339.  
  340.     Color Considerations
  341.     --------------------
  342.     In DLDCOLOR Object mode, when changing the background color, the 
  343.     new background color is swapped with the old in order to eliminate
  344.     the possibility of having a Drawing color the same as the background
  345.     color, causing a blank screen.
  346.  
  347.  
  348. Documentation Changes
  349. ---------------------
  350.  
  351. In "Chapter 4 - Changing Colors", p.4-2, the second paragraph should read: 
  352.  
  353.     "...change by moving the highlight box around with the arrow cursor 
  354.     control keys and pressing ENTER..." You may use the up and down arrows
  355.     as well as the left and right.
  356.  
  357.  
  358.  
  359. II. What if I Have Problems?
  360. ============================
  361.  
  362. The answers to the most often asked technical support questions can be
  363. found in the Tips, Tricks & Troubleshooting chapter of your "TurboDLD
  364. Installation Guide". Please check there first.
  365.  
  366. If you are having a problem which you cannot resolve, and you need to
  367. contact Technical Support, please try to duplicate, and document the
  368. steps required to reproduce the problem.  As you document the problem,
  369. list your current system configuration, including video board, resolution,
  370. number of colors configured, etc. Also, if possible, try to duplicate the
  371. problem with an AutoCAD sample file so that it can be easily re-created
  372. by a technician, if necessary. To contact Technical Support, refer to
  373. Appendix A in your "TurboDLD Installation Guide".
  374.  
  375. Please note that Technical Support for Panacea's OEM software products
  376. (defined as: Software bundled as a component part of a hardware product)
  377. is the responsibility of the hardware manufacturer, not Panacea. If you
  378. encounter a problem with TurboDLD, and cannot find a satisfactory answer
  379. from the reference manual or from the hardware manufacturer, Panacea
  380. will offer free technical support ONLY via one of the following (voice
  381. phone support is specifically excluded):
  382.  
  383.     FAX:          603-434-2461  Attn: Technical Support
  384.     E-mail:       tech_support@panacea.com
  385.     CompuServe:   ACAD Forum
  386.  
  387. Panacea reserves the right to change its OEM software product support
  388. policies at any time, including charging for support and/or limiting
  389. support.
  390.  
  391.  
  392. III. Other Panacea Products
  393. ===========================
  394.  
  395. Panacea Inc., the world's leading developer of Autodesk display 
  396. drivers offers drivers for virtually all Autodesk products.
  397.  
  398.  
  399. DLD Classic & Deluxe
  400. ====================
  401. Our DLD Classic line of AutoCAD display list drivers were the
  402. industry standard for AutoCAD Release 10 (real mode).
  403.  
  404. DLD real mode ADI 4.0 drivers are available for EGA, VGA, 8514/A, S3,
  405. TIGA, and XGA graphics platforms, and support AutoCAD Release 10,
  406. Release 11/286, AutoShade 1.x, and AutoSketch for DOS.
  407.  
  408.  
  409. PanaIcon
  410. ========
  411. Pop-Up icon generator for any AutoCAD 12 version. Allows you to create
  412. your own pop-up graphical icon menus from any AutoCAD .DWG file and
  413. share them with other PanaIcon users. Ideal for sites with both DOS
  414. and Windows versions of Release 12.
  415.  
  416.  
  417. panaStation
  418. ===========
  419. Protected-mode display driver for MicroStation v4.x and 5.x. Offers
  420. increased performance and support for virtually all graphics platforms.
  421.  
  422.  
  423. PanaMate
  424. ========
  425. Don't settle for 320x200 resolution in Animator Pro. PanaMate is your 
  426. resolution solution. It supports the highest resolution available on your
  427. graphics board to let you get the most out of Animator Pro.
  428.  
  429.  
  430. Panacea products can be ordered through your local dealer. For
  431. more information on these products and the name of a dealer near
  432. you, call Panacea's Sales department at (603) 437-5022 x725, or send
  433. internet e-mail to "sales@panacea.com".
  434.  
  435.  
  436.           Comments, etc., can be addressed to:
  437.  
  438.              Panacea Inc.
  439.               Post Office Square
  440.              24 Orchard View Drive
  441.           Londonderry, NH  03053-3351
  442.                                                                                  U.S.A.
  443.             
  444.       Voice: (603) 437-5022   FAX: (603) 434-2461
  445.  
  446.  
  447. IV. Install License Information
  448. ===============================
  449.  
  450. The installation program used to install TurboDLD, "INSTALL", is 
  451. based on licensed software provided by Knowledge Dynamics Corp, PO Box 1558, 
  452. Canyon Lake, Texas 78130-1558 (USA). "INSTALL" is Copyright (c) 1987-1992 
  453. by Knowledge Dynamics Corp which reserves all copyright protection 
  454. worldwide. "INSTALL" is provided to you for the exclusive purpose of 
  455. installing TurboDLD. Panacea Inc. has modified the software as 
  456. provided by Knowledge Dynamics Corp, and thus the performance and behavior 
  457. of the "INSTALL" program shipped with TurboDLD may not represent the 
  458. performance and behavior of install as shipped by Knowledge Dynamics Corp.  
  459. Panacea is exclusively responsible for the support of TurboDLD, 
  460. including support during the installation phase. In no event will Knowledge 