home
***
CD-ROM
|
disk
|
FTP
|
other
***
search
/
The Fred Fish Collection 1.6
/
ffcollection-1-6-1993-02.iso
/
parnet
/
parnet.doc
< prev
next >
Wrap
Text File
|
1992-02-01
|
6KB
|
154 lines
/* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *\
* |_o_o|\\ Copyright (c) 1988, 1989, 1990 The Software Distillery. *
* |. o.| || All Rights Reserved *
* | . | || Written by Doug Walker and John Toebes *
* | o | || The Software Distillery *
* | . |// 207 Livingston Dr. *
* ====== Cary, NC 27513 *
* PLINK: DWALKER BIX: DJWALKER *
* BBS:(919)-460-7430 Deep Thought *
\* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * */
SEE THE FILE 'README' IN THIS DISTRIBUTION FOR IMPORTANT COPYRIGHT
INFORMATION. CONTACT THE AUTHORS IF YOU DO NOT HAVE THIS FILE.
============================================================================
INSTALLING THE NETWORK FILESYSTEM:
1. Make a cable according to the instructions in the enclosed 'Cable.doc'
file. Connect the two Amigas with the cable.
2. Copy parnet.device to your DEVS: directory on BOTH machines.
3. Put a mountlist entry for the network handler in the DEVS:MOUNTLIST
file on both Amigas. You can do this by appending the enclosed
'mountlist' file to your DEVS:MOUNTLIST file. Simply attach the
enclosed file to the end of DEVS:MOUNTLIST with a text editor. Choose
one of the machines to be UNIT 1 and change the mountlist entry for that
machine to set the UNIT to 1.
4. Copy netpnet-handler to the l: directory on both machines.
5. Copy netpnet-server to the C: directory on the both machines.
============================================================================
RUNNING THE NETWORK FILESYSTEM:
1. Run the NET: servers. On the machine that has UNIT=0 in the mountlist,
you must start the server with the command
NETPNET-SERVER UNIT 1
On the machine that has UNIT=1 in the mountlist, use
NETPNET-SERVER UNIT 0
or, since UNIT 0 is the default, you can simply specify
NETPNET-SERVER
The reason it's backwards from the UNIT= in the mountlist is that you are
starting a server to serve the NET: on the OTHER machine, not the machine
that the server is running on.
2. Issue the MOUNT command on both Amigas:
MOUNT NET:
3. NET: is now ready for access. NET: will at first appear to be empty if
you do a DIR of it from the CLI. You can refer to devices on the remote
side by NET:devicename/path (for example, NET:DH0/C/LIST) This will force
NET: to mount the remote device. The device (DH0 in this case) will
appear in a DIR of NET: after this. No drawer icons will appear in the
workbench window for NET: until you have forced NET: to load them. Simply
issuing the command
CD NET:devicename
will be sufficient to load the device 'devicename'.
The 'devicename' you use can be any mounted device or volume on the
remote machine.
4. If you want to use NET: with the workbench, you must provide an icon file
for each device you mount on the remote machine. You can do this by
copying any drawer-type icon file to NET:devicename.info after the
specified devicename has been mounted.
CD NET:DH0 ; make sure DH0 is mounted
COPY SYS:C.INFO NET:DH0.INFO ; make sure DH0 has an icon file
You only need to do this once for hard disks and other permanent devices,
but RAM: will 'forget' this icon every time you reboot, so you will need
to recopy the icon each time. (NOTE: A file will appear in the root of
the remote device called 'node.rinfo'. This is where NET: stores the
icon file you give it. Deleting the node.rinfo file will remove your
device's icon.)
Note that if you do a DIR of NET:, you will always see the .info files
for your mounted remote devices EVEN IF THEY DO NOT EXIST. NET: assumes
the icon files are there, and doesn't go check unless it needs to. If
your .info files are appearing with the DIR command, but not under
workbench, you need to copy a drawer-type icon into NET: as described
above.
============================================================================
The provided NETSTAT command gives you a visual idea of how much work your
network is doing. Run it with the command
RUN NETSTAT NET:
Click on the close gadget in the upper left corner to exit.
============================================================================
Differences and enhancements:
VERSION 08/90
- Fixes for AmigaDOS 2.0
- Reboot support cleaned up
- Two-way connections supported
- One level of data copying removed to improve performance
VERSION 04/90:
Second parallel port version released
- Various minor bug fixes
- ACTION_SET_DATE packet implemented
- Support added to allow rebooting of one node independant of the other
- Automatic mounting of remote nodes at first reference added
- Using Matt Dillon's new parnet.device
VERSION 08/89:
First Parallel port version released
VERSION 07/18/89:
- Speed improved due to decreasing minimum packet size
Should help when loading executables over the network and when doing
directory operations.
- Debugging code removed
This makes the code smaller and faster
- Bug fixed in the ACTION_CREATE_DIR packet
VERSION 05/09/89:
First version released using DNET
============================================================================