# These are the initialization values for the SI3050 that are used
# for USA per SiLabs defaults for ring validation
# We support ring type B; which says we should recognize between 15.3 and
# 68 Hz
# 4/26/05 RSS Enable 200Hz Highpass filter
TX_GAIN_CTRL2 = 0 # .5 db gain
TX_GAIN_CTRL3 = 5
RX_GAIN_CTRL2 = 1 # 1.5 db gain
RX_GAIN_CTRL3 = 5
INT_CTRL1 = 0
INT_CTRL2 = 0
DAA_CTRL5 = a2 # FULL, FOH = 128 ms, enable 200Hz Highpass filter
RING_VAL_CTRL1 = 16
RING_VAL_CTRL2 = 2d # RDY = 0, RTO = 640 ms , RCC = 512 ms
RING_VAL_CTRL3 = 99
DC_TERM = c0 # DVC = 3.5V
ACTERM = 0 # 600 Ohm termination
END