  1. @
  2. opening message
  3. SPC EXpert - Statistical Process Control Software
  4.  
  5. Developed by:     Quality Software Designs, Inc.
  6.                   933 East Stroop Road
  7.                   Kettering, Ohio 45429
  8.                   messages: (513) 299-3023
  9.                   email:    marks@meaddata.com
  10.                          or ...!uunet!meaddata!marks
  11.  
  12. Quality Software Designs, Inc. can provide customized
  13. versions of SPC EXpert.  Call or write for more information.
  14. @
  15. Next Version
  16.               TELL ME WHAT YOU THINK!!!
  17.  
  18. It's been a while since SPC EXpert was released.
  19. I would like to see any comments or ideas you may have.
  20.  
  21. To remove this message or learn more about the next
  22. version of SPC EXpert, write to:
  23.  
  24.           Quality Software Designs, Inc.
  25.           933 East Stroop Road
  26.           Kettering, Ohio 45429
  27.           email:   marks@meaddata.com
  28.                 or ...!uunet!meaddata!marks
  29. @
  30. SPC Redistribution
  31.              SPC EXpert Secondary Distribution
  32. @
  33. get_fname help1
  34.         FILE NAME SELECTION MENU
  35.  
  36. 1. Type in the filename you want to select
  37.  
  38.    e.g. "run.dmo" or "scat.dmo"
  39.  
  40. or
  41.    
  42. 2. Type in the PATTERN for a group of files
  43.    for selection by menu.
  44.    
  45.    e.g.  "*.*" or "a:*.dmo" or "car.*"
  46.  
  47. or
  48.    
  49. 3. Hit <ENTER> for a menu of all files
  50. @
  51. get_fname help
  52.         FILE NAME SELECTION MENU
  53.  
  54. 1. Select a file from the menu.
  55.  
  56. 2. If you do not wish to make a selection,
  57.    press ESC or click the right mouse button.
  58. @
  59. banner_2
  60.               QUESTIONS OR COMMENTS
  61.  
  62. If you have questions or comments, please
  63. feel free to write:
  64.  
  65.         Quality Software Designs, Inc.
  66.         933 East Stroop Road
  67.         Kettering, Ohio 45429
  68.         (513) 299-3023  6:00pm-9:00pm Eastern
  69.         email:    marks@meaddata.com
  70.                or ...!uunet!meaddata!marks
  71.  
  72. @
  73. investigate_1
  74.                      INVESTIGATE
  75.  
  76. Investigate any out-of-control points in your process.
  77.  
  78.                        DISCOVER
  79.  
  80. 1. Any out of control pattern means that something is not normal.
  81.  
  82. 2. Something different is going on. Something is affecting the
  83.    process.
  84.  
  85. 3. It is important to figure out what it is   --   good or bad.
  86.  
  87.                            ACT
  88.  
  89. 1. If its bad, you have to track the cause and get rid of it.
  90.  
  91. 2. If its good, you want to know too.  Then you can make sure
  92.    that you keep doing things that way.
  93. @
  94. TOP_MENU_RESPONSES
  95. A. Select Data File
  96. B. Select Graphic Type
  97. C. View Graphic
  98. D. Control Chart Analysis
  99. E. View Chart Patterns
  100. F. Expert Consultation
  101. G. On-Line Documentation
  102. H. Print/Export
  103. I. Options
  104. J. Editor & File Manager
  105. K. Shell to DOS
  106. quit
  107. @
  108. TOP_MENU_HELP
  109.                          SPC EXpert
  110.                             MAIN MENU ()
  111.  
  112. #m>HELP<;hypertext help;info.hyp#m - Click on the >HELP< or Press Enter to learn how
  113.        to operate the hypertext help system.
  114.  
  115.     #m(X.Y.Z);MENU_NOTATION;screens.hyp#m SPC EXpert menu navigation notation.
  116.             
  117. A. Select Data File
  118.       - Select the name of the ASCII file which contains the
  119.         process data.
  120.  
  121.  
  122. B. Select Graphic Type 
  123.       - Select the type of control chart.
  124.         Automatic selection is available.
  125.  
  126.  
  127. C. View Graphic
  128.       - Graphic display of the current chart/diagram.
  129.  
  130.  
  131. D. Control Chart Analysis
  132.       - Automatic analysis of Control Chart for unusual patterns which
  133.         suggest the presence of assignable causes of variation in your
  134.         process.  Stamdard "Western Electric" rules apply.
  135.  
  136.  
  137. E. View Control Chart Patterns
  138.       - Graphic Display of each unusual pattern found in D. highlighted
  139.         on the control chart
  140.  
  141.  
  142. F. Expert Consultation 
  143.       - Expert System consultation which provides generic advice on the
  144.         meaning of each pattern unusual pattern found in D.
  145.  
  146.  
  147. G. #mOn-Line Documentation;MORE_INFO_MENU;info.hyp#m
  148.       - More detailed explanation of the SPC EXpert software and its
  149.         licensing and redistribution policies.
  150.  
  151.  
  152. H. #mPrint/Export Menu;PRINT_MENU#m
  153.       - Allows you to print a paper copy of the current chart/diagram.
  154.         Also allows you to select the type of printer, printing mode, and
  155.         the printer connection.  This menua also allows the user to export
  156.         SPCEX's output to Computer Graphics Metafiles (CGM) or Encapsulated
  157.         Post Script Files.
  158.  
  159.  
  160. I. #mOptions Menu;OPTIONS_MENU#m
  161.       - Allows the ADVANCED USER to select the statistical methods used
  162.         to create the charts/diagrams as well as to alter the appearance
  163.         of the graphics.
  164.                   
  165.  
  166. J. #mEditor & File Manager;EDIT_MENU#m
  167.       - Integrated text editor and file management system.
  168.         The user has the option to:
  169.                                
  170.              1. Edit the current data file
  171.              2. Edit or create any file
  172.              3. View a file
  173.              4. Copy a file
  174.              5. Rename a file
  175.              6. Delete a File
  176.  
  177.  
  178. K. Shell To DOS
  179.       - Allows the user to access DOS while still having SPCEX in memory.
  180.  
  181.  
  182. quit
  183.       - Exit the SPCEX application.
  184. @
  185. TOP_CHART_TEXT
  186. Choose an SPC tool type.
  187. @
  188. TOP_CHART_MENU
  189. A. Control Charts
  190. B. Diagrams and Graphs
  191. Return to SPC MAIN MENU
  192. @
  193. TOP_CHART_HELP
  194.                SPC TOOL TYPES
  195.  
  196. A. #mControl Charts;charts0;info.hyp#m - The following control
  197. chart types are available in SPC EXpert :
  198.  
  199.                     1. #mRun chart;charts12;info.hyp#m
  200.                     2. #mXbar-R control chart;charts13;info.hyp#m
  201.                     3. #mX Moving Range control chart;charts14;info.hyp#m
  202.                     4. #mXbar-S control chart;charts16;info.hyp#m
  203.                     5. #mpn control chart;charts18;info.hyp#m
  204.                     6. #mp control chart;charts18;info.hyp#m
  205.                     7. #mc control chart;charts21;info.hyp#m
  206.                     8. #mu control chart;charts21;info.hyp#m
  207.                     
  208.                     
  209. B. #mDiagrams & Graphs;graph0;info.hyp#m - The following diagrams and graphs are
  210.                available in SPC EXpert :
  211.                        
  212.                        1. #mBar Graph;graph1;info.hyp#m
  213.                        2. #mPareto Diagram;graph3;info.hyp#m
  214.                        3. #mScatter Diagram;graph6;info.hyp#m
  215.                        4. #mHistogram;graph9;info.hyp#m
  216.                        5. #mFrequency POLYGON;graph10;info.hyp#m
  217.                        6. #mCDF or Ogive;graph11;info.hyp#m
  218.                        7. #mPie Chart;graph5;info.hyp#m
  219.                        8. Data Tables
  220.                        9. Multiple Graphs
  221. @
  222. CHART_MENU_RESPONSES
  223. A. Automatic chart selection
  224. B. X (Run) Chart
  225. C. Xbar Chart
  226. D. R Chart
  227. E. S Chart
  228. F. Moving Range chart
  229. G. Xbar-R control chart
  230. H. Xbar-S control chart
  231. I. X Moving Range control chart
  232. J. pn control chart
  233. K. p control chart
  234. L. c control chart
  235. M. u control chart
  236. Return to Previous Menu
  237. @
  238. CHART_MENU_TEXT
  239. @
  240. CHART_MENU_HELP
  241.                  CHART TYPE SELECTION MENU
  242.  
  243. 1. Use this menu to select the type of control chart to use.
  244.  
  245. 2. If you need help making this selection, choose option A.
  246.    You will be asked 1 to 3 questions concerning the nature
  247.    of your process data.  From your response(s), the control
  248.    chart type will be automatically selected.
  249.  
  250. 3. To directly select a control chart type, choose
  251.    options B - M.
  252.  
  253. 4. To exit this menu, select the last option.
  254.  
  255.       Click/select for #mOverview of Control Charts;charts0;info.hyp#m.
  256. @
  257. DIAGRAM_MENU_RESPONSES
  258. A. Bar Graph
  259. B. Pareto Diagram
  260. C. Pie Chart
  261. D. Table
  262. E. Histogram
  263. F. Frequency POLYGON
  264. G. CDF or Ogive
  265. H. Scatter Diagram
  266. I. Multiple Graphs
  267. Return to Previous Menu
  268. @
  269. DIAGRAM_MENU_TEXT
  270. @
  271. DIAGRAM_MENU_HELP
  272.            DIAGRAM TYPE SELECTION MENU
  273.  
  274. 1. Use this menu to select the type of diagram to use.
  275.  
  276. 2. To directly select a diagram type, choose
  277.    options A - I.
  278.  
  279. 3. To exit this menu, select the last option.
  280.  
  281.       Click/select for #mOverview of Graphs/Diagrams;graph0;info.hyp#m.
  282. @
  283. DATA_TYPE_TEXT
  284. What type of process data are
  285. you measuring?
  286. @
  287. DATA_TYPE_MENU
  288. A. Measurement
  289. B. Attribute
  290. @
  291. DATA_TYPE_HELP
  292. A. Measurement Data - This is indiscrete or continuous valued data.
  293.  
  294.                       Examples include : length
  295.                                          weight
  296.                                          time
  297.  
  298. B. Attribute Data   - This is discrete valued data.
  299.  
  300.                       Examples include : number of errors
  301.                                          number of rejects
  302.                                          number of reworks
  303. @
  304. SAMPLE_SIZE_TEXT
  305. Is your logical group size (Sample Size)
  306. constant or variable?
  307. @
  308. SAMPLE_SIZE_MENU
  309. A. Constant
  310. B. Variable
  311. @
  312. SAMPLE_SIZE_HELP
  313. 1. Constant - Examples include :
  314.  
  315.               (a) # pin holes in a fixed area of sheet metal
  316.               (b) # rejects out of a fixed batch size
  317.  
  318. 2. Variable - Examples include :
  319.  
  320.               (a) # pin holes in pieces of sheet metal differing in area
  321.               (b) # rejects out of batches differing in size
  322.               (c) # typographic errors in letters (of differing length)
  323. @
  324. VALUES_VARIABILITY_TEXT
  325. Do you want to show process
  326. values, variability, or both?
  327. @
  328. VALUES_VARIABILITY_MENU
  329. A. Values
  330. B. Variability
  331. C. Both
  332. @
  333. VALUES_VARIABILITY_HELP
  334.                      VALUES vs VARIABILITY
  335.                    Measurement Control Charts
  336.  
  337. Use this menu to indicate what aspect, values and/or variability,
  338. of your measurement data you wish to display.
  339.  
  340.    A. Values - Show the actual levels (values) of your process
  341.                measurements.  Control charts which show process
  342.                levels or values include individuals (RUN) and
  343.                averages (XBAR).
  344.  
  345.    B. Variability - Show how your process measurements are
  346.                     dispersed.  Control charts which show
  347.                     process dispersion or variability include
  348.                     range (R), standard deviation (S) and
  349.                     moving range (MR).
  350.    
  351.    C. Both - Show both the level (values) and the variability 
  352.              of your process.  Charts which show both values
  353.              and variability include individuals moving range
  354.              (XMR), average and range (XBAR_R), and average
  355.              and standard deviation (XBAR_S).  These are simply
  356.              combinations of charts from A and B above.
  357. @
  358. SAMPLE_CARDINALITY_TEXT
  359. In what range is your
  360. logical group (sample)
  361. size?
  362. @
  363. SAMPLE_CARDINALITY_MENU
  364. A. 1
  365. B. 2 to 10
  366. C. Larger Than 10
  367. @
  368. SAMPLE_CARDINALITY_HELP
  369. LOGICAL GROUP SIZE
  370. Measurement Control Charts
  371.  
  372. Use this menu to indicate the relative size of your process samples
  373. when gathering measurement data.
  374.  
  375.     A. 1              - Appropriate measurement control charts include:
  376.                            VALUES: RUN
  377.                            VARIABILITY: MR    
  378.  
  379.     B. 2 to 10        - Appropriate measurement control charts include:
  380.                            VALUES: XBAR
  381.                            VARIABILITY: R    
  382.  
  383.  
  384.     C. Larger Than 10 - Appropriate measurement control charts include:
  385.                            VALUES: XBAR
  386.                            VARIABILITY: S
  387. @
  388. DEFECT_TEXT
  389. Is your attribute data measuring
  390. defectives or defects?
  391. @
  392. DEFECT_MENU
  393. A. Defectives
  394. B. Defects
  395. @
  396. DEFECT_HELP
  397. 1. Defectives - This is the number of parts/units/etc that
  398.                 are rejected or un-usable.  Examples include :
  399.  
  400.                     (a) # letters returned for rework.
  401.                     (b) # sheets of metal rejected.
  402.  
  403.  
  404. 2. Defects - This is the number of flaws in a part/unit/etc.
  405.              Example include :
  406.              
  407.                    (a) # typographic errors in a letter.
  408.                    (b) # pin holes in a sheet of metal.
  409. @
  410. CONSULT_TEXT
  411. Select a pattern for
  412. expert consultation
  413. @
  414. CONSULT_HELP
  415.             EXPERT CONSULTATION MENU
  416.  
  417. 1. Several Patterns which suggest the presence of
  418.    assignable causes of variation within the process
  419.    have been located in your control chart.
  420.  
  421. 2. Select a pattern for which you would like more
  422.    information.
  423.    
  424. 3. Select option 1 to see advice for every pattern
  425.    found in your chart.
  426.  
  427. 4. Select the last option to return to the MAIN MENU.
  428. @
  429. VIEW_TEXT
  430. Select a pattern
  431. to view highlighted
  432. on the chart.
  433. @
  434. VIEW_HELP
  435.                VIEW PATTERNS MENU
  436.  
  437.  
  438. 1. Several Patterns which suggest the presence of
  439.    assignable causes of variation within the process
  440.    have been located in your control chart.
  441.  
  442.  
  443. 2. Select a pattern which you would like to view.
  444.  
  445.  
  446. 3. Select option 1 to view every pattern found in your chart.
  447.  
  448.  
  449. 4. Select the last option to return to the MAIN MENU.
  450. @
  451. view_in_control_chart
  452. Your chart is in control!  This means that there are
  453. no unusual patterns within the chart which suggest
  454. the presence of assignable causes of variation.
  455.  
  456. Select the consultation option for further details.
  457. @
  458. PRINT_MENU
  459. A. Print Graphic
  460. B. View Graphic
  461. C. Printer Type
  462. D. Print Orientation/Density
  463. E. I/O Port
  464. F. Advanced Comm Parameters
  465. G. Save Printer Settings
  466. H. Export to Graphics File
  467. I. Export to EPS File
  468. J. Manually Set Video Mode
  469. Return To MAIN MENU
  470. @
  471. PRINT_HELP
  472.             SPC EXpert PRINT MENU (H)
  473.  
  474. A. Print Graphic (H.A)
  475.      - Produces a hard copy of the current graphic.
  476.                          
  477.  
  478. B. View Chart/Diagram (H.B)
  479.      - Displays graphics of current graphic.
  480.  
  481.  
  482. C. Select Printer Type (H.C)
  483.      - Allows you the specify what kind of printer you have.
  484.        The following printers are supported:
  485.  
  486.               A. Epson FX/IBM Pro Printer
  487.               B. Epson LQ
  488.               C. IBM Proprinter X24
  489.               D. IBM Quietwriter
  490.               E. Toshiba P321
  491.               F. HP Laserjet
  492.               G. Post Script
  493.               H. Paint Jet
  494.               I. HP 7470 Plotter
  495.               J. HP 7475 Plotter
  496.               K. HP 7550 Plotter
  497.               L. HP 7585 Plotter
  498.               M. HP Desk Jet  
  499.               N. HP Desk Jet 500C
  500.               O. HP Desk Jet 550C
  501.               P. HP Laser Jet III
  502.               Q. HP Laser Jet IV
  503.               R. Canon Laser
  504.  
  505. D. Select Orientation/density (H.D)
  506.       - Allows you to select the orientation and print density
  507.         of your printout. The print orientations and densities
  508.         supported vary with each printer:
  509.  
  510.                           
  511.                  A. #mEpson FX/IBM Pro Printer;$FX#m
  512.                  B. #mEpson LQ;$LQ#m
  513.                  C. #mIBM Proprinter X24;$PP24#m
  514.                  D. #mIBM Quietwriter;$IBMQ#m
  515.                  E. #mToshiba P321;$TSH#m
  516.                  F. #mHP Laserjet;$LJ#m
  517.                  G. #mPost Script;$PS#m
  518.                  H. #mPaint Jet;$PJET#m
  519.                  I. #mHP 7470 Plotter;$HP7470#m
  520.                  J. #mHP 7475 Plotter;$HP7475#m
  521.                  K. #mHP 7550 Plotter;$HP7550#m
  522.                  L. #mHP 7585 Plotter;$HP7585#m  
  523.                  M. #mHP Desk Jet;$DJ#m
  524.                  N. #mHP Desk Jet 500C;$DJC#m
  525.                  O. #mHP Desk Jet 550C;$DJC550#m
  526.                  P. #mHP Laser Jet III;$LJ3R#m
  527.                  Q. #mHP Laser Jet IV;$LJ4#m 
  528.                  R. #mCanon Laser;$CANON#m
  529.    
  530. E. Select I/O Port (H.E)
  531.      -  Allows you to select the external port to which your printer
  532.         is connected.  The following ports are supported:
  533.                        
  534.                  A. LPT1 (Parallel Port #1)
  535.                  B. LPT2 (Parallel Port #2)
  536.                  C. COM1 (Serial Port #1)
  537.                  D. COM2 (Serial Port #2)
  538.                  
  539.  
  540. F. Advanced Comm Parameters (H.F)
  541.        - This allows you to adjust some specific communications
  542.          parameters between your computer and your printer for
  543.          the SERIAL Ports (COM1 & COM2).  These include:
  544.          
  545.                           A. Baud [default: 2400]
  546.                           B. Parity [default: None]
  547.                           C. # Data Bits [default: 8]
  548.                           D. # Stop Bits [default: 1]
  549.                           
  550.                *** The default settings are usually appropriate.
  551.                    Only attempt to adjust these as a last resort.
  552.                              
  553.  
  554. G. Save Printer Settings (H.G)
  555.        - This option allows you to save the settings that you selected
  556.          in options C,D,E, and J.  The next time you start SPCEX, those
  557.          saved settings will be selected by default.
  558.                            
  559.  
  560.  
  561. H. Export to Graphics File (H.H)
  562.        - This allows you to save the current graphic, as it appears
  563.          when viewed with option B, to one of several Computer Graphics
  564.          file formats.  These graphics format can be imported into a wide
  565.          variety of commercial graphics software packages such as Harvard
  566.          Graphics, WordPerfect, MicroSoft Word, and MicroSoft PowerPoint.
  567.  
  568.              A. PCX 16 Color 640x480
  569.              B. PCX Mono 640x480
  570.              C. Windows 3.X BMP 16 Color 640x480
  571.              D. Windows 3.X BMP Mono 640x480
  572.              E. Gem IMG Low  Mono 720x540
  573.              F. Gem IMG Med  Mono 1440x1080
  574.              G. Gem IMG High Mono 2880x2160
  575.              H. TIFF (compressed) Low 720x540
  576.              I. TIFF (compressed) Med 1440x1080
  577.              J. TIFF (compressed) High 2880x2160
  578.              K. TIFF (uncompressed) Low 720x540
  579.              L. TIFF (uncompressed) Med 1440x1080
  580.              M. TIFF (uncompressed) High 2880x2160
  581.              N. ANSI CGM 256 Color 32767x24574
  582.              O. ANSI CGM Mono 32767x24574
  583.              P. AutoCad DXF 16 Color 10000x7200
  584.              Q. Video Show (NAPLPS) 256 Color 2048x1824
  585.              R. WordPerfect Graphics 16 Color 7800x6000
  586.              S. WordPerfect Graphics Mono 7800x6000
  587.  
  588.  
  589. I. Export to EPS File (H.I)
  590.        - This allows you to save the current graphic, as it appears when
  591.          viewed with option B, to a Encapsulated Post Script (EPS) file.
  592.          An EPS file can be taken to any Post Script printer and printed
  593.          at a later date.
  594.  
  595.  
  596. J. Manually Set Video Mode (H.J)
  597.        - This allows you to manually select the type of monitor that your
  598.          computer has.  SPCEX WILL DETECT THE TYPE OF MONITOR YOU HAVE ON
  599.          MOST SYSTEMS.  However, some computer systems do not work with
  600.          SPCEX's AUTODETECT feature and may require you to explicitly
  601.          specify what type of monitor you have.
  602.                            
  603.                            
  604. Return to MAIN MENU
  605.        - Return to Main Menu. 
  606. @
  607. TYPE_PRINTER_TEXT
  608. @
  609. TYPE_PRINTER_MENU
  610. A. Epson FX/IBM Pro Printer
  611. B. Epson LQ
  612. C. IBM Proprinter X24
  613. D. IBM Quietwriter
  614. E. Toshiba P321
  615. F. HP Laserjet
  616. G. Post Script
  617. H. Paint Jet
  618. I. HP 7470 Plotter
  619. J. HP 7475 Plotter
  620. K. HP 7550 Plotter
  621. L. HP 7585 Plotter
  622. M. HP Desk Jet
  623. N. HP Desk Jet 500C
  624. O. HP Desk Jet 550C
  625. P. HP Laser Jet III
  626. Q. HP Laser Jet IV
  627. R. Canon Laser
  628. return
  629. @
  630. TYPE_PRINTER_HELP
  631.           PRINTER TYPES SUPPORTED BY SPC EXpert (H.C)
  632.  
  633. This option allows you the specify what kind of printer
  634. you have.  The following printers are supported:
  635.                          
  636.  
  637.          A. Epson FX/IBM Pro Printer (H.C.A)
  638.          B. Epson LQ                 (H.C.B)
  639.          C. IBM Proprinter X24       (H.C.C)
  640.          D. IBM Quietwriter          (H.C.D)
  641.          E. Toshiba P321             (H.C.E)
  642.          F. HP Laserjet              (H.C.F)
  643.          G. Post Script              (H.C.G)
  644.          H. Paint Jet                (H.C.H)
  645.          I. HP 7470 Plotter          (H.C.I)
  646.          J. HP 7475 Plotter          (H.C.J)
  647.          K. HP 7550 Plotter          (H.C.K)
  648.          L. HP 7585 Plotter          (H.C.L)
  649.          M. HP Desk Jet              (H.C.M)
  650.          N. HP Desk Jet 500C         (H.C.N)
  651.          O. HP Desk Jet 550C         (H.C.O)
  652.          P. HP Laser Jet III         (H.C.P)
  653.          Q. HP Laser Jet IV          (H.C.Q)
  654.          R. Canon Laser              (H.C.R)
  655.          
  656.  If your printer is not on this list, you still may be able to
  657.  make a printout.  Consult your printer's documentation of just
  658.  simply experiment.
  659. @
  660. DPI_HELP
  661.        Select Orientation/density (H.D) HELP
  662.  
  663. Allows you to select the orientation and print density
  664. of your printout. The print orientations and densities
  665. supported vary with each printer:
  666.  
  667.                           
  668.        A. #mEpson FX/IBM Pro Printer;$FX#m
  669.        B. #mEpson LQ;$LQ#m
  670.        C. #mIBM Proprinter X24;$PP24#m
  671.        D. #mIBM Quietwriter;$IBMQ#m
  672.        E. #mToshiba P321;$TSH#m
  673.        F. #mHP Laserjet;$LJ#m
  674.        G. #mPost Script;$PS#m
  675.        H. #mPaint Jet;$PJET#m
  676.        I. #mHP 7470 Plotter;$HP7470#m
  677.        J. #mHP 7475 Plotter;$HP7475#m
  678.        K. #mHP 7550 Plotter;$HP7550#m
  679.        L. #mHP 7585 Plotter;$HP7585#m  
  680.        M. #mHP Desk Jet;$DJ#m
  681.  
  682. @
  683. PORT_TEXT
  684. Select The I/O Port
  685. to which your printer
  686. is connected.
  687. @
  688. PORT_MENU
  689. A. LPT1
  690. B. LPT2
  691. C. COM1
  692. D. COM2
  693. @
  694. PORT_HELP
  695.                  DEVICE PORT (H.E) HELP
  696.  
  697. This menu allows you to select the external port to which
  698. your printer is connected.  The following ports are supported:
  699.                        
  700.  
  701.                 A. LPT1 (Parallel Port #1)*
  702.                 B. LPT2 (Parallel Port #2)
  703.                 C. COM1 (Serial Port #1)
  704.                 D. COM2 (Serial Port #2)
  705.  
  706. * LPT1 is the standard printer port.
  707. @
  708. COMM_TEXT
  709.  
  710. @
  711. COMM_MENU
  712. A. Baud
  713. B. Parity
  714. C. Data Bits
  715. D. Stop Bits 
  716. E. XON/XOFF
  717. F. Reset to Defaults
  718. Return
  719. @
  720. COMM_HELP
  721.       Advanced Comm Parameters Help (H.F)
  722.  
  723. This allows you to adjust some specific communications
  724. parameters between your computer and your printer for
  725. the SERIAL Ports (COM1 & COM2).  These include:
  726.          
  727. A. Baud [default: 2400]      (H.F.A)
  728. B. Parity [default: None]    (H.F.B)
  729. C. # Data Bits [default: 8]  (H.F.C)
  730. D. # Stop Bits [default: 1]  (H.F.D)
  731. E. XON/XOFF [default: XOFF]  (H.F.E)
  732.                           
  733.    *** The default settings are usually appropriate.
  734.        Only attempt to adjust these as a last resort.
  735.  
  736. @
  737. BAUD_TEXT
  738.  
  739. @
  740. BAUD_MENU
  741. A. 110 Baud
  742. B. 150 Baud
  743. C. 300 Baud
  744. D. 600 Baud
  745. E. 1200 Baud
  746. F. 2400 Baud
  747. G. 4800 Baud
  748. H. 9600 Baud
  749. Return
  750. @
  751. BAUD_HELP
  752. Serial Port Baud Rate (H.F.A) HELP
  753.  
  754. This allows you to adjust the rate
  755. (Baud rate) at which the computer
  756. attempts to communicate through
  757. the serial ports (COM1 or COM2).
  758. The default setting is  2400 Baud.
  759.  
  760. The choices for Baud rate are:
  761.  
  762.     A. 110 Baud  (H.F.A.A)
  763.     B. 150 Baud  (H.F.A.B)
  764.     C. 300 Baud  (H.F.A.C)
  765.     D. 600 Baud  (H.F.A.D)
  766.     E. 1200 Baud (H.F.A.E)
  767.     F. 2400 Baud (H.F.A.F)
  768.     G. 4800 Baud (H.F.A.G)
  769.     H. 9600 Baud (H.F.A.H)
  770. @
  771. PARITY_TEXT
  772.  
  773. @
  774. PARITY_MENU
  775. A. None
  776. B. Odd Parity
  777. C. Even Parity
  778. Return
  779. @
  780. PARITY_HELP
  781. Serial Port Parity (H.F.B) HELP
  782.  
  783. This allows you to select one of
  784. the methods the computer and printer
  785. use to chack that no errors in 
  786. communication over the serial
  787. ports (COM1 or COM2) have occured.
  788.  
  789. The choices for parity are:
  790.  
  791.     A. None         (H.F.B.A)
  792.     B. Odd Parity   (H.F.B.B)
  793.     C. Even Parity  (H.F.B.C)
  794.  
  795. The default setting is  NONE.
  796.  
  797. @
  798. DATA_TEXT
  799.  
  800. @
  801. DATA_MENU
  802. A. 7 Data Bits
  803. B. 8 Data Bits
  804. Return
  805. @
  806. DATA_HELP
  807.  Serial Port DATA BITS (H.F.C) HELP
  808.  
  809. This allows you to select the serial
  810. port (COM1 or COM2) communications
  811. setting for Number of DATA BITS.
  812.  
  813. The choices for Data Bits are:
  814.  
  815.     A. 7 Data Bits (H.F.C.A)
  816.     B. 8 Data Bits (H.F.C.B)
  817.  
  818. The default setting is  8 Data Bits.
  819.  
  820. @
  821. STOP_TEXT
  822.  
  823. @
  824. STOP_MENU
  825. A. 1 Stop Bit
  826. B. 2 Stop Bits
  827. Return
  828. @
  829. STOP_HELP
  830.  Serial Port STOP BITS (H.F.D) HELP
  831.  
  832. This allows you to select the serial
  833. port (COM1 or COM2) communications
  834. setting for Number of STOP BITS.
  835.  
  836. The choices for Stop Bits are:
  837.  
  838.     A. 1 Stop Bit  (H.F.D.A)
  839.     B. 2 Stop Bits (H.F.D.B)
  840.  
  841.  
  842. The default setting is  1 Stop Bit.
  843.  
  844. @
  845. XON_TEXT
  846.  
  847. @
  848. XON_MENU
  849. A. XOFF
  850. B. XON
  851. Return
  852. @
  853. XON_HELP
  854.  Serial Port XON/XOFF (H.F.E) HELP
  855.  
  856. This allows you to select the serial
  857. port (COM1 or COM2) communications
  858. setting for XON/XOFF.
  859.  
  860. The choices are:
  861.  
  862.     A. XOFF (H.F.E.A)
  863.     B. XON  (H.F.E.B)
  864.  
  865. The default setting is  XOFF.
  866.  
  867. @
  868. $FX
  869. A. Half Low
  870. B. Half Med
  871. C. Half High
  872. D. Land Low
  873. E. Land Med
  874. F. Land High
  875. G. Full Low
  876. H. Full Med
  877. I. Full High
  878. Return
  879. @
  880. $LQ
  881. A. Half Low
  882. B. Half Med
  883. C. Half High
  884. D. Land Low
  885. E. Land Med
  886. F. Land High
  887. G. Full Low
  888. H. Full Med
  889. I. Full High
  890. Return
  891. @
  892. $PP24
  893. A. Half Low
  894. B. Half Med
  895. C. Half High
  896. D. Land Low
  897. E. Land Med
  898. F. Land High
  899. G. Full Low
  900. H. Full Med
  901. I. Full High
  902. Return
  903. @
  904. $IBMQ
  905. A. Half Low
  906. B. Half Med
  907. C. Half High
  908. D. Land Low
  909. E. Land Med
  910. F. Land High
  911. G. Full Low
  912. H. Full Med
  913. I. Full High
  914. Return
  915. @
  916. $TSH
  917. A. Half
  918. B. Land
  919. C. Full
  920. Return
  921. @
  922. $LJ
  923. A. Half Low
  924. B. Half Med
  925. C. Half High
  926. D. Land Low
  927. E. Land Med
  928. F. Land High
  929. G. Full Low
  930. H. Full Med
  931. I. Full High
  932. Return
  933. @
  934. $LJ3R
  935. A. Half Low
  936. B. Half Med
  937. C. Half High
  938. D. Land Low
  939. E. Land Med
  940. F. Land High
  941. G. Full Low
  942. H. Full Med
  943. I. Full High
  944. Return
  945. @
  946. $CANON
  947. A. Half Low
  948. B. Half Med
  949. C. Half High
  950. D. Land Low
  951. E. Land Med
  952. F. Land High
  953. G. Full Low
  954. H. Full Med
  955. I. Full High
  956. Return
  957. @
  958. $LJ4
  959. A. Half Low
  960. B. Half Med
  961. C. Half High
  962. D. Land Low
  963. E. Land Med
  964. F. Land High
  965. G. Full Low
  966. H. Full Med
  967. I. Full High
  968. Return
  969. @
  970. $DJ
  971. A. Half Low
  972. B. Half Med
  973. C. Half High
  974. D. Land Low
  975. E. Land Med
  976. F. Land High
  977. G. Full Low
  978. H. Full Med
  979. I. Full High
  980. Return
  981. @
  982. $DJC
  983. A. Half Low
  984. B. Half Med
  985. C. Half High
  986. D. Land Low
  987. E. Land Med
  988. F. Land High
  989. G. Full Low
  990. H. Full Med
  991. I. Full High
  992. Return
  993. @
  994. $DJC550
  995. A. Half Low
  996. B. Half Med
  997. C. Half High
  998. D. Land Low
  999. E. Land Med
  1000. F. Land High
  1001. G. Full Low
  1002. H. Full Med
  1003. I. Full High
  1004. Return
  1005. @
  1006. $PJET
  1007. A. Half Low     Mono
  1008. B. Land Low     Mono
  1009. C. Half High    Mono
  1010. D. Land High    Mono
  1011. E. Half Low   4 Color
  1012. F. Land Low   4 Color
  1013. G. Half High  4 Color
  1014. H. Land High  4 Color
  1015. I. Half Low   8 Color
  1016. J. Land Low   8 Color
  1017. K. Half High  8 Color
  1018. L. Land High  8 Color
  1019. M. Half Low  16 Color
  1020. N. Land Low  16 Color
  1021. Return
  1022. @
  1023. $PS
  1024. A. Half    Mono
  1025. B. Land    Mono
  1026. C. Full    Mono
  1027. D. Half 16 Grays
  1028. E. Land 16 Grays
  1029. F. Full 16 Grays
  1030. G. Half 16 Color
  1031. H. Land 16 Color
  1032. I. Full 16 Color
  1033. Return 
  1034. @
  1035. $HP7470
  1036. A. Draft 16 Color 10000x7200
  1037. B. LQ    16 Color 10000x7200
  1038. Return
  1039. @
  1040. $HP7475
  1041. A. Draft 16 Color 10000x7200
  1042. B. LQ    16 Color 10000x7200
  1043. C. Draft 16 Color 15200x10000
  1044. D. LQ    16 Color 15200x10000
  1045. Return
  1046. @
  1047. $HP7550
  1048. A. Draft 16 Color 10000x7200
  1049. B. LQ    16 Color 10000x7200
  1050. Return
  1051. @
  1052. $HP7585
  1053. A. Draft 16 Color 5580x9000
  1054. B. LQ    16 Color 5580x9000
  1055. C. Draft 16 Color 14200x9000
  1056. D. LQ    16 Color 14200x9000
  1057. Return
  1058. @
  1059. DTP_TEXT
  1060. @
  1061. DTP_HELP
  1062. Use this menu to choose the Graphics File
  1063. format that you would like to save the
  1064. current chart to.  The following formats
  1065. available:
  1066.  
  1067.      - Zsoft PCX
  1068.      - Windows 3 BMP
  1069.      - GEM IMG
  1070.      - TIFF (compressed & uncompressed)
  1071.      - ANSI CGM
  1072.      - AutoDesk DXF
  1073.      - General Parametrics VideoShow
  1074.        (ANSI NAPLPS with some extensions)
  1075.      - WordPerfect WPG
  1076.      
  1077. @
  1078. DTP_MENU
  1079. A. PCX 16 Color 640x480
  1080. B. PCX Mono 640x480
  1081. C. Windows 3.X BMP 16 Color 640x480
  1082. D. Windows 3.X BMP Mono 640x480
  1083. E. Gem IMG Low  Mono 720x540
  1084. F. Gem IMG Med  Mono 1440x1080
  1085. G. Gem IMG High Mono 2880x2160
  1086. H. TIFF (compressed) Low 720x540
  1087. I. TIFF (compressed) Med 1440x1080
  1088. J. TIFF (compressed) High 2880x2160
  1089. K. TIFF (uncompressed) Low 720x540
  1090. L. TIFF (uncompressed) Med 1440x1080
  1091. M. TIFF (uncompressed) High 2880x2160
  1092. N. ANSI CGM 256 Color 32767x24574
  1093. O. ANSI CGM Mono 32767x24574
  1094. P. AutoCad DXF 16 Color 10000x7200
  1095. Q. Video Show (NAPLPS) 256 Color 2048x1824
  1096. R. WordPerfect Graphics 16 Color 7800x6000
  1097. S. WordPerfect Graphics Mono 7800x6000
  1098. return
  1099. @
  1100. $DTP
  1101. $PCX 0 13 1
  1102. $PCX 1 13 0
  1103. $BMP 0 14 1
  1104. $BMP 1 14 0
  1105. $IMG 0 15 0
  1106. $IMG 1 15 0
  1107. $IMG 2 15 0
  1108. $TIF 0 16 0
  1109. $TIF 1 16 0
  1110. $TIF 2 16 0
  1111. $UTIF 0 17 0
  1112. $UTIF 1 17 0
  1113. $UTIF 2 17 0
  1114. $CGM 0 18 1
  1115. $CGM 1 18 0
  1116. $DXF 0 19 1
  1117. $VSHO 0 20 1
  1118. $WPG 0 21 1
  1119. $WPG 1 21 0
  1120. @
  1121. C$FX
  1122. 0
  1123. 0
  1124. 0
  1125. 0
  1126. 0
  1127. 0
  1128. 0
  1129. 0
  1130. 0
  1131. @
  1132. C$LQ
  1133. 0
  1134. 0
  1135. 0
  1136. 0
  1137. 0
  1138. 0
  1139. 0
  1140. 0
  1141. 0
  1142. @
  1143. C$PP24
  1144. 0
  1145. 0
  1146. 0
  1147. 0
  1148. 0
  1149. 0
  1150. 0
  1151. 0
  1152. 0
  1153. @
  1154. C$IBMQ
  1155. 0
  1156. 0
  1157. 0
  1158. 0
  1159. 0
  1160. 0
  1161. 0
  1162. 0
  1163. 0
  1164. @
  1165. C$TSH
  1166. 0
  1167. 0
  1168. 0
  1169. @
  1170. C$LJ
  1171. 0
  1172. 0
  1173. 0
  1174. 0
  1175. 0
  1176. 0
  1177. 0
  1178. 0
  1179. 0
  1180. @
  1181. C$LJ3R
  1182. 0
  1183. 0
  1184. 0
  1185. 0
  1186. 0
  1187. 0
  1188. 0
  1189. 0
  1190. 0
  1191. @
  1192. C$CANON
  1193. 0
  1194. 0
  1195. 0
  1196. 0
  1197. 0
  1198. 0
  1199. 0
  1200. 0
  1201. 0
  1202. @
  1203. C$LJ4
  1204. 0
  1205. 0
  1206. 0
  1207. 0
  1208. 0
  1209. 0
  1210. 0
  1211. 0
  1212. 0
  1213. @
  1214. C$DJ
  1215. 0
  1216. 0
  1217. 0
  1218. 0
  1219. 0
  1220. 0
  1221. 0
  1222. 0
  1223. 0
  1224. @
  1225. C$DJC
  1226. 1
  1227. 1
  1228. 1
  1229. 1
  1230. 1
  1231. 1
  1232. 1
  1233. 1
  1234. 1
  1235. @
  1236. C$DJC550
  1237. 1
  1238. 1
  1239. 1
  1240. 1
  1241. 1
  1242. 1
  1243. 1
  1244. 1
  1245. 1
  1246. @
  1247. C$PJET
  1248. 0
  1249. 0
  1250. 0
  1251. 0
  1252. 1
  1253. 1
  1254. 1
  1255. 1
  1256. 1
  1257. 1
  1258. 1
  1259. 1
  1260. 1
  1261. 1
  1262. @
  1263. C$PS
  1264. 0
  1265. 0
  1266. 0
  1267. 1
  1268. 1
  1269. 1
  1270. 1
  1271. 1
  1272. 1
  1273. @
  1274. C$HP7470
  1275. 1
  1276. 1
  1277. @
  1278. C$HP7475
  1279. 1
  1280. 1
  1281. 1
  1282. 1
  1283. @
  1284. C$HP7550
  1285. 1
  1286. 1
  1287. @
  1288. C$HP7585
  1289. 1
  1290. 1
  1291. 1
  1292. 1
  1293. @
  1294. OPTIONS_MENU
  1295. A. Control Charts
  1296. B. Distribution Graphs
  1297. C. PIE/BAR/PARETO/TABLE
  1298. D. Scatter Diagrams
  1299. E. Process Specifications
  1300. F. Data File Formats
  1301. G. Fonts & Font Sizes
  1302. H. Titles/Stats/etc
  1303. I. Saving/Recalling Options
  1304. J. Display Current Options
  1305. Return to Main Menu
  1306. @
  1307. OPTIONS_TEXT
  1308. @
  1309. OPTIONS_HELP
  1310.              Options Menu Help Screen (I)
  1311.  
  1312. #mA. Control Charts;CC_OPTIONS_MENU#m
  1313.       This allows you to set parameters which affect the statistical
  1314.       calculations and appearance of all control charts.
  1315.  
  1316. #mB. Distribution Graphs;DIST_OPTIONS_MENU#m
  1317.       This allows you to set parameters which affect the statistical
  1318.       calculations and appearance of HISTOGRAMS, frequency POLYGONS,
  1319.       and CDFs.
  1320.  
  1321. #mC. PIE/BAR/PARETO/TABLE;PIE_OPTIONS_MENU#m
  1322.       This allows you to set parameters which affect the statistical
  1323.       calculations and appearance of PIE charts, BAR graphs, PARETO
  1324.       diagrams, and data TABLES.
  1325.  
  1326. #mD. Scatter Diagrams;SCATTER_OPTIONS_MENU#m
  1327.       This allows you to set parameters which affect the statistical
  1328.       calculations and appearance of SCATTER DIAGRAMS.
  1329.  
  1330. #mE. Process Specifications;SPECS_OPTIONS_MENU#m
  1331.  
  1332.       This menu allows you to set upper and lower SPECIFICATION 
  1333.       limits.  These specification limits are used for process
  1334.       capability statistics in control charts, distribution graphs,
  1335.       and scatter diagrams.
  1336.              
  1337. #mF. Data File Formats;RAW_DATA_OPTIONS_MENU#m
  1338.       This option has been included in SPC EXpert to accomadate
  1339.       future enhancements which include the ability to import
  1340.       data from DBase-type database files.
  1341.  
  1342. #mG. Fonts & Font Sizes;FONTS_OPTIONS_MENU#m
  1343.       This allows you to select the font sizes and types to be used
  1344.       for the titles and axis labels on all graphics.
  1345.  
  1346. #mH. Titles/Stats/etc;DISPLAY_OPTIONS_MENU#m
  1347.       This allows you to set parameters which affect all types of
  1348.       charts and diagrams.  These include:
  1349.  
  1350.                      A. Titles ON/OFF
  1351.                      B. Enhanced Labeling ON/OFF
  1352.                      C. Summary Stats ON/OFF
  1353.                      D. Sound ON/OFF
  1354.  
  1355. #mI. Saving/Recalling Options;SAVE_CFG_OPTIONS_MENU#m
  1356.       Allows you to save and recall your options settings.
  1357.  
  1358. J. Display Current Options
  1359.       Use this to display the current options settings.
  1360.  
  1361. Return to Main Menu
  1362.  
  1363. @
  1364. CC_OPTIONS_MENU
  1365. A. Range to Display
  1366. B. Range to Calc Control Limits
  1367. C. Range for Stats/Regression
  1368. D. Method for Center Line
  1369. E. Method for Control Limits
  1370. F. Dist Graph to Display
  1371. G. X-Axis Labeling Convention
  1372. H. Y-Axis Labeling Convention
  1373. I. Control Limits/Zones
  1374. J. Process Specs ON/OFF
  1375. K. Linear Regression ON/OFF
  1376. L. Eliminate Outliers ON/OFF
  1377. M. MIN Lengths for Analysis
  1378. Return to OPTIONS MENU
  1379. @
  1380. CC_OPTIONS_TEXT
  1381.  
  1382. @
  1383. CC_OPTIONS_HELP
  1384.            Control Chart Options Menu (I.A) Help Screen
  1385.  
  1386. A. Range to Display (I.A.A)
  1387.     - You may select the range of data to be displayed on the output.
  1388.       A maximum of 16000 data points may be displayed at one time for
  1389.       any control chart.  The practical limit for most video monitors
  1390.       is about 200-300 data points.  The graphic output is scaled to
  1391.       accommodate the data ranges.
  1392.  
  1393. B. Range to Calc Control Limits (I.A.B)
  1394.     - You may set what range of data is used in the calculation of
  1395.       the control limits (upper & lower limits, center line, Cp, Cpl,
  1396.       Cpu, Cpk, and percent in-spec).  The display of these statistics
  1397.       may be turned on/off using selection I.H.C.  The control chart
  1398.       process specifications (I.A.J) must be turned ON to display the
  1399.       in-spec and capability statistics.
  1400.       
  1401. C. Range for Stats/Regression (I.A.C)
  1402.     - You may set the range of data used to calculate standard
  1403.       statistics and linear regression.  The standard statistics
  1404.       display may be turned on/off using selection I.H.C.  This
  1405.       range is also the range of data used for the automated control
  1406.       chart ANALYSIS - selection D.
  1407.       
  1408. D. Method for Center Line (I.A.D)
  1409.     - You may select the method used to determine the center line
  1410.       using data in the Limits Range (I.A.B).  The center line can
  1411.       be determined using the mean, median or a user specified value.
  1412.  
  1413. E. Method for Control Limits (I.A.E)
  1414.     - You may select the method used to calculate the control limits
  1415.       using data in the Limits Range (I.A.B).
  1416.  
  1417. F. Dist Graph to Display (I.A.F)
  1418.     - You may display a data distribution function on a control chart.
  1419.  
  1420. G. X-Axis Labeling Convention (I.A.G)
  1421.     - You may select the type of label for the X (horizontal) Axis.
  1422.  
  1423. H. Y-Axis Labeling Convention (I.A.H)
  1424.     - You may select the type of label for the Y (vertical) Axis.
  1425.  
  1426. I. Control Limits/Zones (I.A.I)
  1427.     - You may specify what control limit markings are plotted on a
  1428.       control chart besides the center line.
  1429.  
  1430. J. Process Specs ON/OFF (I.A.J)
  1431.     - You may use this selection to toggle ON/OFF the current process
  1432.       specifications.  Process specifications may be set using
  1433.       selection I.E.  When this is ON, the process specifications
  1434.       are graphically displayed on the control chart.  Capability
  1435.       statistics are displayed when Process Specs (I.A.J) and
  1436.       Summary Stats (I.H.C) are BOTH "ON".
  1437.       
  1438. K. Linear Regression ON/OFF (I.A.K)
  1439.     - This allows you to plot (or not) the linear regression line
  1440.       calculated from the data points in the Stats Range (I.A.C)
  1441.       on control charts.  The default setting is "OFF". 
  1442.  
  1443. L. Eliminate Outliers ON/OFF (I.A.L)
  1444.     - You may designate any data points in a data file for control
  1445.       charts as "outliers"   When eliminate outliers is ON, points
  1446.       defined as outliers will be highlighted and will not be used
  1447.       in the calculations.  The default setting is "OFF".
  1448.  
  1449. M. MIN Lengths for Analysis (I.A.M)
  1450.     - You may use this to set the minimum length required for each
  1451.       control chart out-of-control condition to be reported after
  1452.       the automatic control chart analysis (selection D).
  1453.  
  1454. Return to OPTIONS MENU
  1455.     - Use this option (or ESC or RIGHT-MOUSE-BUTTON or <F2>) to
  1456.       return to the SPC EXpert options menu (selection I).
  1457. @
  1458. DISPLAY_RANGE_MENU
  1459. A. All
  1460. B. Last N
  1461. C. Range a to b
  1462. Return
  1463. @
  1464. DISPLAY_RANGE_TEXT
  1465.  
  1466. @
  1467. DISPLAY_RANGE_HELP
  1468.               Display Range Menu (I.A.A) Help
  1469.                      [default: ALL]
  1470.  
  1471. You may select the range of data to be displayed on the output.
  1472. A maximum of 16000 data points may be displayed at one time for
  1473. all control charts.  The graphic output is scaled to accommodate
  1474. the data ranges.  To set the range, select one of the following:
  1475.  
  1476. A. All (I.A.A.A)
  1477.     - Display the entire control chart (up to 16000 points).
  1478.       The practical limit due to screen resolution is 200-300.
  1479.  
  1480. B. Last N (I.A.A.B)
  1481.     - Display the most recent N (user provided) data points.
  1482.       You will be prompted to enter a value for N.
  1483.  
  1484. C. Range a to b (I.A.A.C)
  1485.     - Display a range of data points where you provide the
  1486.       start and end data indices to be displayed.  The first
  1487.       data point has index 1.  You will be prompted to enter
  1488.       the values for indices a and b.
  1489.  
  1490. Return
  1491.     - Do not change the DISPLAY range.
  1492. @
  1493. CL_RANGE_MENU
  1494. A. All
  1495. B. First M
  1496. C. Range a to b
  1497. D. Same as DISPLAY
  1498. Return
  1499. @
  1500. CL_RANGE_TEXT
  1501.  
  1502. @
  1503. CL_RANGE_HELP
  1504.              Control Limits Range Help (I.A.B)
  1505.                      [default: ALL]
  1506.  
  1507. You may set what range of data is used in the calculation of
  1508. the control limits (upper & lower limits, center line, Cp, Cpl,
  1509. Cpu, Cpk, and percent in-spec).  The display of these statistics
  1510. may be turned on/off using selection I.H.C.  The control chart
  1511. process specifications (I.A.J) must be turned ON to display the
  1512. in-spec and capability statistics.  You nay choose from:
  1513.  
  1514. A. All (I.A.B.A)
  1515.     - Use all of the data points to calculate the control limits.
  1516.  
  1517. B. First M (I.A.B.B)
  1518.     - Use the first M (user provided) data points for control
  1519.       limits.  You will be prompted to enter a value for M.
  1520.  
  1521. C. Range a to b (I.A.B.C)
  1522.     - Use a user provided range to calculate the control limits.
  1523.       the first data point has index 1.  You will be prompted
  1524.       to enter the values for indices a and b.
  1525.  
  1526. D. Same as DISPLAY (I.A.B.D)
  1527.     - Calculate the control limits using the data in the
  1528.       DISPLAY (I.A) range.
  1529.  
  1530. Return
  1531.     - Do not change the control limits range.
  1532. @
  1533. STATS_RANGE_MENU
  1534. A. All
  1535. B. Range a to b
  1536. C. Same as LIMITS
  1537. D. Same as DISPLAY
  1538. Return
  1539. @
  1540. STATS_RANGE_TEXT
  1541.  
  1542. @
  1543. STATS_RANGE_HELP
  1544.                 Stats Range Menu Help (I.A.C)
  1545.                      [default: ALL]
  1546.  
  1547. You may set the range of data used to calculate standard
  1548. statistics and linear regression.  The standard statistics
  1549. display may be turned on/off using selection I.H.C.  This
  1550. range is also the range of data used for the automated control
  1551. chart ANALYSIS - selection D.  Select from:
  1552.  
  1553.  
  1554. A. All (I.A.C.A)
  1555.     - Calculate statistics and perform chart analysis on ALL
  1556.       data points in the control chart.
  1557.  
  1558. B. Range a to b (I.A.C.B)
  1559.     - Calculate statistics and perform chart analysis using
  1560.       the data points in a user provide range and data point
  1561.       indices.  The first data point in the control chart has
  1562.       index 1.  You will be prompted to enter values for a and b.
  1563.       
  1564. C. Same as LIMITS (I.A.C.C)
  1565.     - Calculate statistics and perform chart analysis using
  1566.       data points in the LIMITS (I.A.B) range.
  1567.  
  1568. D. Same as DISPLAY (I.A.C.D)
  1569.     - Calculate statistics and perform chart analysis using
  1570.       data points in the DISPLAY (I.A.A) range.
  1571.  
  1572. Return
  1573.     - Do not change the STATS range.
  1574. @
  1575. CENTER_LINE_MENU
  1576. A. Mean (Average)
  1577. B. Median
  1578. C. User Defined
  1579. Return
  1580. @
  1581. CENTER_LINE_TEXT
  1582.  
  1583. @
  1584. CENTER_LINE_HELP
  1585.                  Center Line Type Help (I.A.D)
  1586.                        [default: MEAN]
  1587.  
  1588. You may select the method used to determine the center line
  1589. using data in the Limits Range (I.A.B).  NOTE: the center
  1590. line is used as the process center when applying the "Western
  1591. Electric" rules during control chart analysis (selection D).
  1592. The center line can be determined using the folowing:
  1593.  
  1594.  
  1595. A. Mean (Average) (I.A.D.A)
  1596.     - Use the average of the data points in the LIMITS range
  1597.       to calculate the center line.  This is the most common
  1598.       method used to determine the process center line.
  1599.  
  1600. B. Median (I.A.D.B)
  1601.     - Use the median of the data points in the LIMITS range
  1602.       to calculate the center line.  This method is often
  1603.       to minimize the effect of outliers and unusual data
  1604.       values on the process center calculation.  The median
  1605.       is the value for which an equal number of data values
  1606.       fall above and below.
  1607.  
  1608. C. User Defined (I.A.D.C)
  1609.     - Use a value you provide as the process center.  THIS
  1610.       METHOD IS NOT RECOMMENDED!  Use at your own risk!
  1611.  
  1612. Return
  1613.     - Return to the Control Chart Options (I.A) menu.
  1614.       
  1615. @
  1616. CONTROL_LIMIT_MENU
  1617. A. TABLE look-up
  1618. B. 3*Sigma(N)
  1619. C. 3*Sigma(N-1)
  1620. D. M*Sigma(N)
  1621. E. M*Sigma(N-1)
  1622. F. 3*User-Defined-Sigma
  1623. Return
  1624. @
  1625. CONTROL_LIMIT_TEXT
  1626.  
  1627. @
  1628. CONTROL_LIMIT_HELP
  1629.                     Control Limit Type Help (I.A.E)
  1630.                        (default: TABLE Lookup)
  1631.  
  1632. You may select the method used to calculate the control limits
  1633. using data in the Limits Range (I.A.B).  NOTE: the control 
  1634. limits are used as +- 3 standard deviations when applying the
  1635. "Western Electric" rules during control chart analysis
  1636. (selection D).  The center line can be determined as folows:
  1637.  
  1638.  
  1639. A. TABLE look-up (I.A.E.A)
  1640.     - This approximates the control limits from statistical
  1641.       tables or formulas.  This is the traditional method
  1642.       used to calculate control limits.  In case where your
  1643.       process may be out of control in the LIMITS range,
  1644.       this method is recommended.
  1645.  
  1646. B. 3*Sigma(N) (I.A.E.B)
  1647.     - This approximates the control limits using +- 3 standard
  1648.       deviations with N degrees of freedom.  This method should
  1649.       only be used to calculate control limits, IF YOU ARE
  1650.       CERTAIN THAT YOUR PROCESS IS STABLE AND IN CONTROL in the
  1651.       LIMITS range.
  1652.  
  1653.  
  1654. C. 3*Sigma(N-1) (I.A.E.C)
  1655.     - This approximates the control limits using +- 3 standard
  1656.       deviations with N-1 degrees of freedom.  This method should
  1657.       only be used to calculate control limits, IF YOU ARE
  1658.       CERTAIN THAT YOUR PROCESS IS STABLE AND IN CONTROL in the
  1659.       LIMITS range.
  1660.  
  1661.  
  1662. D. M*Sigma(N) (I.A.E.D)
  1663.     - This approximates the control limits using +- M standard
  1664.       deviations with N degrees of freedom - where you are prompted
  1665.       for the value of M.  This method should only be used to calculate
  1666.       control limits, IF YOU ARE CERTAIN THAT YOUR PROCESS IS
  1667.       STABLE AND IN CONTROL in the LIMITS range.  This is commonly
  1668.       used with M<3 in an attempt to reduce the variability of
  1669.       a stable, in-control process.
  1670.  
  1671.  
  1672. E. M*Sigma(N-1) (I.A.E.E)
  1673.     - This approximates the control limits using +- M standard
  1674.       deviations with N-1 degrees of freedom - where you are prompted
  1675.       for the value of M.  This method should only be used to calculate
  1676.       control limits, IF YOU ARE CERTAIN THAT YOUR PROCESS IS
  1677.       STABLE AND IN CONTROL in the LIMITS range.  This is commonly
  1678.       used with M<3 in an attempt to reduce the variability of
  1679.       a stable, in-control process.
  1680.  
  1681.  
  1682. F. 3*User-Defined-Sigma (I.A.E.F)
  1683.     - This approximates the control limits using +- 3 times a
  1684.       standard deviation you provide.  This method might be used
  1685.       in an attempt to reduce the variability of a stable, in-
  1686.       control process.  Several types of short run control charts
  1687.       (WAIT FOR NEXT RELEASE OF SPC EX) eliminate any need for
  1688.       this though.
  1689.       
  1690. Return
  1691.     - Return to the Control Chart Options (I.A) menu.
  1692.  
  1693. @
  1694. CC_DIST_MENU
  1695. A. none
  1696. B. Histogram
  1697. C. Frequency Polygon
  1698. D. Ogive (CDF)
  1699. E. Individuals Histogram
  1700. F. Individuals Polygon
  1701. G. Individuals Ogive (CDF)
  1702. Return
  1703. @
  1704. CC_DIST_TEXT
  1705.  
  1706. @
  1707. CC_DIST_HELP
  1708.    Control Chart Distribution Graph Display Type Help (I.A.F)
  1709.                       [default: none]
  1710.                       
  1711. You may display a data distribution function on a control chart.
  1712. The distribution graphic may be either a HISTOGRAM, frequency
  1713. POLYGON, or CDF.  The distribution graphic is calculated using
  1714. the data values in the STATS (I.A.C) range.  For XBAR control
  1715. charts, there must be a distinction between the collection of
  1716. averages and the collection of individual data points - this
  1717. is made by selecting and "INDIVIDUALS" distribution graphic.
  1718. The appearance of the distribution graphic may be changed using
  1719. the Distribution Graphics Option (I.B) menus.  Select from:
  1720.  
  1721.  
  1722. A. none (I.A.F.A)
  1723.     - Do not display any distribution graphic.
  1724.  
  1725. B. Histogram (I.A.F.B)
  1726.     - Display a HISTOGRAM of the chart values in the STATS range.
  1727.       For an XBAR chart, this will reflect the distribution of
  1728.       the sample averages.
  1729.  
  1730. C. Frequency Polygon (I.A.F.C)
  1731.     - Display a POLYGON of the chart values in the STATS range.
  1732.       For an XBAR chart, this will reflect the distribution of
  1733.       the sample averages.
  1734.  
  1735. D. Ogive (CDF) (I.A.F.D)
  1736.     - Display a CDF of the chart values in the STATS range.
  1737.       For an XBAR chart, this will reflect the distribution of
  1738.       the sample averages.
  1739.  
  1740. E. Individuals Histogram (I.A.F.E)
  1741.     - Display a HISTOGRAM of the individual data values in the
  1742.       STATS range.  For an XBAR chart, this will reflect the
  1743.       distribution of the individual data samples.
  1744.  
  1745. F. Individuals Polygon (I.A.F.F)
  1746.     - Display a POLYGON of the individual data values in the
  1747.       STATS range.  For an XBAR chart, this will reflect the
  1748.       distribution of the individual data samples.
  1749.  
  1750. G. Individuals Ogive (CDF) (I.A.F.G)
  1751.     - Display a CDF of the individual data values in the
  1752.       STATS range.  For an XBAR chart, this will reflect the
  1753.       distribution of the individual data samples.
  1754.  
  1755. Return
  1756.     - Return to the Control Chart Options (I.A) menu.
  1757.  
  1758. @
  1759. CC_X_AXIS_MENU
  1760. A. none
  1761. B. User Defined Strings
  1762. C. Values of Data Points
  1763. D. Data point indices (1,2,...N)
  1764. Return
  1765. @
  1766. CC_X_AXIS_TEXT
  1767.  
  1768. @
  1769. CC_X_AXIS_HELP
  1770.         Control Chart X Axis Labeling Type Help (I.A.G)
  1771.                      [default: none]
  1772.  
  1773. You may select the type of label for the X (horizontal) Axis.
  1774. Select from the following:
  1775.  
  1776. A. none (I.A.G.A)
  1777.     - Do not print labels along the X-axis.
  1778.       
  1779.  
  1780. B. User Defined Strings (I.A.G.B)
  1781.     - Displays the strings (possibly empty if none provided)
  1782.       that you provide in the comment field of the data file.
  1783.       If you provide no comments in the data file, then this
  1784.       will appear exactly as X-axis lable option none (I.A.G.A).
  1785.  
  1786.  
  1787. C. Values of Data Points (I.A.G.C)
  1788.     - Displays the actual value of the data point in the chart.
  1789.       This value is the actual number plotted above/below the
  1790.       X-Axis -- for XBAR charts this value will be the sample
  1791.       average, for P charts the fraction defective, etc.
  1792.  
  1793. D. Data point indices (1,2,...N) (I.A.G.D)
  1794.     - Labels the X-Axis with sequential integers beginning with
  1795.       1.  These integer indices coorespond to the indice you
  1796.       provide in the DISPLAY range (I.A.A), LIMITS range (I.A.B),
  1797.       and the STATS range (I.A.C).
  1798.  
  1799. Return
  1800.     - Return to the Control Chart Options (I.A) menu.
  1801. @
  1802. CC_Y_AXIS_MENU
  1803. A. none
  1804. B. UCL & LCL only
  1805. C. Graduated Scale
  1806. Return
  1807. @
  1808. CC_Y_AXIS_TEXT
  1809.  
  1810. @
  1811. CC_Y_AXIS_HELP
  1812.           Control Chart Y Axis Labeling Type Help (I.A.F)
  1813.                    [default: UCL & LCL]
  1814.  
  1815. You may select the type of label for the Y (Vertical) Axis.
  1816. Select from the following:
  1817.  
  1818.  
  1819. A. none (I.A.F.A)
  1820.     - Do not label the Y axis.
  1821.       
  1822.  
  1823. B. UCL & LCL only (I.A.F.B)
  1824.     - Label only the Centerline and the upper (UCL) and lower
  1825.       (LCL) control limits.  The values for the LCL and UCL
  1826.       will be part of these labels.
  1827.       
  1828.  
  1829. C. Graduated Scale (I.A.F.C)
  1830.     - Label the Center line, UCL, LCL, and intermediate values
  1831.       (one and two sigma) on the Y Axis.  The values will be
  1832.       part of these labels.
  1833.       
  1834.       
  1835. Return
  1836.     - Return to the Control Chart Options (I.A) menu.
  1837. @
  1838. CC_ZONES_MENU
  1839. A. none
  1840. B. UCL only
  1841. C. LCL only
  1842. D. UCL & LCL
  1843. E. zones
  1844. Return
  1845. @
  1846. CC_ZONES_TEXT
  1847.  
  1848. @
  1849. CC_ZONES_HELP
  1850.              Control Chart ZONEs Menu Help (I.A.G)
  1851.                      [default: UCL & LCL]
  1852.  
  1853. You may specify what control limit markings are plotted on the
  1854. control chart besides the center line.  Select from the following:
  1855.  
  1856. A. none (I.A.G.A)
  1857.     - Display the center line only.
  1858.       
  1859.  
  1860. B. UCL only (I.A.G.B)
  1861.     - Display the center line and UCL (upper control limit) only.
  1862.       
  1863.  
  1864. C. LCL only (I.A.G.C)
  1865.     - Display the center line and LCL (lower control limit) only.
  1866.  
  1867.  
  1868. D. UCL & LCL (I.A.G.D)
  1869.     - Display the center line, UCL (upper control limit) and
  1870.       LCL (lower control limit).
  1871.  
  1872.  
  1873. E. zones (I.A.G.E)
  1874.     - Display the center line, UCL (upper control limit), LCL
  1875.       (lower control limit), and the "1-sigma" and "2-sigma"
  1876.       lines above and below the center line.  These vertical
  1877.       ranges are often called "zones":
  1878.       
  1879.              -1 to +1 sigma                  :  ZONE C
  1880.              -2 to -1 sigma & +1 to +2 sigma :  ZONE B
  1881.              -3 to -2 sigma & +2 to +3 sigma :  ZONE A
  1882.  
  1883. Return
  1884.     - Return to the Control Chart Options (I.A) menu.
  1885. @
  1886. CC_MIN_PAT_LEN_MENU
  1887. A. run
  1888. B. inc_trend
  1889. C. dec_trend
  1890. D. shift_up
  1891. E. shift_down
  1892. F. cyclic
  1893. G. mixture
  1894. H. stratification
  1895. Return
  1896. @
  1897. CC_MIN_PAT_LENGTH_TEXT
  1898.  
  1899. @
  1900. CC_MIN_PAT_LEN_HELP
  1901.     Control Chart Analysis Minimum Pattern Lengths (I.A.M)
  1902.                   (defaults given below)
  1903.  
  1904. You may use this to set the minimum length required for each
  1905. control chart out-of-control condition to be reported after
  1906. the automatic control chart analysis (selection D).  Various
  1907. "Western Electric" type rules are applied to test for these
  1908. conditions which suggest the presence of un-natural causes of
  1909. variation in a process.
  1910.  
  1911.  
  1912. A. run (I.A.M.A) [default: 7]
  1913.     - A run is and sequence of points which all fall on the
  1914.       same side of the center line.  A process which is in
  1915.       control (only natural causes of variation) should have
  1916.       values randomly above and below the centerline.
  1917.       
  1918.  
  1919. B. inc_trend (I.A.M.B) [default: 7]
  1920.     - An increasing trend is a sequence of points for which
  1921.       each is higher/larger than the previous.  A process which
  1922.       is in control (only natural causes of variation) should
  1923.       have values which are randomly above and below the
  1924.       preceeding value.
  1925.  
  1926.  
  1927. C. dec_trend (I.A.M.C) [default: 7]
  1928.     - A decreasing trend is a sequence of points for which
  1929.       each is lower/smaller than the previous.  A process which
  1930.       is in control (only natural causes of variation) should
  1931.       have values which are randomly above and below the
  1932.       preceeding value.
  1933.  
  1934.  
  1935. D. shift_up (I.A.M.D) [default: 10]
  1936.     - A shift-up is a sequence of points for which the first half
  1937.       is below the center line and the second half is above the
  1938.       center line.  A process which is in control (only natural
  1939.       causes of variation) should have values which are randomly
  1940.       above and below the center line.
  1941.  
  1942.  
  1943. E. shift_down (I.A.M.E) [default: 10]
  1944.     - A shift-down is a sequence of points for which the first half
  1945.       is above the center line and the second half is below the
  1946.       center line.  A process which is in control (only natural
  1947.       causes of variation) should have values which are randomly
  1948.       above and below the center line.
  1949.  
  1950.  
  1951. F. cyclic (I.A.M.F) [default: 10]
  1952.     - A cycle is a sequence of points which alternate up and down.
  1953.       A process which is in control (only natural causes of variation)
  1954.       should have values which are randomly above and below the
  1955.       preceeding value.
  1956.  
  1957.  
  1958. G. mixture (I.A.M.G) [default: 10]
  1959.     - A mixture is a sequence of points which are more than 1 sigma
  1960.       above or below the center line.  A normally distributed process
  1961.       which is in control (only natural causes of variation) should
  1962.       have about 68% of its values within +- 1 sigma (standard
  1963.       deviation) of its average (mean).
  1964.       
  1965.  
  1966. H. stratification (I.A.M.H) [default: 10]
  1967.     - Stratification is a sequence of points which are all within
  1968.       +- 1 sigma of the center line.  A normally distributed process
  1969.       which is in control (only natural causes of variation) should
  1970.       have about 32% of its values more than 1 sigma (standard
  1971.       deviation) above or below its average (mean).
  1972.  
  1973.  
  1974. Return
  1975.     - Return to the Control Chart Options (I.A) menu.
  1976. @
  1977. DIST_OPTIONS_MENU
  1978. A. Show Process Specs ON/OFF
  1979. B. Eliminate Outliers ON/OFF
  1980. C. Show Mean ON/OFF
  1981. D. Show Median ON/OFF
  1982. E. Standard Dist Display
  1983. F. Number of Bins
  1984. Return to OPTIONS Menu
  1985. @
  1986. DIST_OPTIONS_TEXT
  1987.  
  1988. @
  1989. DIST_OPTIONS_HELP
  1990.             Distribution Graph Options Menu Help (I.B)
  1991.  
  1992.  
  1993. A. Show Process Specs ON/OFF (I.B.A) [default: OFF]
  1994.     - Use this selection to toggle ON/OFF the process
  1995.       specifications option for distribution graphs.  The
  1996.       process specifications for all tools is set using
  1997.       the PROCESS SPECIFICATIONS MENU (selection I.E).
  1998.       When ON, the process specifications will be displayed
  1999.       over the distribution graphic.  When SUMMARY STATS is
  2000.       turned ON (selection I.H.C) AND this is ON, capability
  2001.       statistics (Cp, Cpk, Cpu, Cpl, etc.) will be displayed
  2002.       in the statistics summary box on the graphic.
  2003.       
  2004.  
  2005. B. Eliminate Outliers ON/OFF (I.B.B) [default: OFF]
  2006.     - When this is ON, all data points marked as user defined
  2007.       outliers (e.g. !45 or ! 0.335) in the data file, will
  2008.       not be used to calculate any statistics or create the
  2009.       distribution graphic.
  2010.       
  2011.  
  2012. C. Show Mean ON/OFF (I.B.C) [default: OFF]
  2013.     - When this is ON, the mean (average) of the data values
  2014.       will be overlaid on the distribution graphic.
  2015.       
  2016.  
  2017. D. Show Median ON/OFF (I.B.D) [default: OFF]
  2018.     - When this is ON, the median of the data values will be
  2019.       overlaid on the distribution graphic.
  2020.  
  2021.  
  2022. E. Standard Dist Display (I.B.E) [default: none]
  2023.     - You may overlay a standard frequency distribution function
  2024.       on the distribution graphic.
  2025.  
  2026.  
  2027.         A.  None.  Does not overlay a frequency distribution.
  2028.         B.  Uniform (best guess)* 
  2029.         C.  Exponential (best guess)* 
  2030.         D.  Normal (best guess)* 
  2031.         E.  LogNormal (best guess)* 
  2032.         F.  Gamma  (best guess)  Not available.
  2033.         G.  Uniform(a,b)
  2034.         H.  Exponential(mu)
  2035.         I.  Normal(mu, sigma)
  2036.         J.  LogNormal(mu,sigma)
  2037.         K.  Gamma(alpha, theta) Not available.
  2038.         L.  Weibull(1,beta,gamma)
  2039.  
  2040.           (* Best guess is based on estimates calculated from
  2041.              the data in the data files.)
  2042.       
  2043.  
  2044. F. Number of Bins (I.B.F) [default: auto]
  2045.     - You may select how many data groups or bins are used to
  2046.       arrange the data.  The maximum is 20, minimum 1, and an
  2047.       auto select option is provided/recommended.
  2048.  
  2049.  
  2050. Return
  2051.     - Return to the Options (selection I) menu.
  2052. @
  2053. DIST_DIST_MENU
  2054. A. none
  2055. B. Uniform     (best guess)
  2056. C. Exponential (best guess)
  2057. D. Normal      (best guess)
  2058. E. LogNormal   (best guess)
  2059. F. Gamma       (best guess)
  2060. G. Uniform(a,b)
  2061. H. Exponential(mu)
  2062. I. Normal(mu,sigma)
  2063. J. LogNormal(mu,sigma)
  2064. K. Gamma(alpha,theta)
  2065. L. Weibull(1,beta,gamma)
  2066. Return
  2067. @
  2068. DIST_DIST_TEXT
  2069.  
  2070. @
  2071. DIST_DIST_HELP
  2072. Distribution Graphs Overlaid Frequency Distribution Type Help (I.B.E)
  2073.                        [default: none]
  2074.  
  2075.  
  2076. You may overlay a standard frequency distribution function on the
  2077. distribution graphic.  The following functions are available:
  2078.  
  2079.  
  2080.         A.  None.  Does not overlay a frequency distribution.
  2081.         B.  Uniform (best guess)* 
  2082.         C.  Exponential (best guess)* 
  2083.         D.  Normal (best guess)* 
  2084.         E.  LogNormal (best guess)* 
  2085.         F.  Gamma  (best guess)  Not available.
  2086.         G.  Uniform(a,b)  where
  2087.             a = Uniform distribution lower limit
  2088.             b = uniform distribution upper limit.
  2089.         H.  Exponential(mu) where
  2090.             mu = mean.
  2091.         I.  Normal(mu, sigma) where
  2092.             mu = mean
  2093.             sigma = standard deviation of n-1.
  2094.         J.  LogNormal(mu,sigma) where
  2095.             mu = mean of the natural logarithms
  2096.             sigma = standard deviation of n-1 for the natural
  2097.             logarithms.
  2098.         K.  Gamma(alpha, theta) Not available.
  2099.         L.  Weibull(1,beta,gamma) where
  2100.             1 = scaling factor
  2101.             beta = shape parameter
  2102.             gamma = start position.
  2103.  
  2104. (* Best guess is based on estimates calculated from the data in the
  2105.    data files.)
  2106.  
  2107. M. Return
  2108.     - Return the the distribution graph options (I.B) menu.
  2109.  
  2110. @
  2111. DIST_BINS_MENU
  2112. A. Auto Select
  2113. B. User Defined
  2114. Return
  2115. @
  2116. DIST_BINS_TEXT
  2117.  
  2118. @
  2119. DIST_BINS_HELP
  2120.               Distribution Graph # Bins Help (I.B.F)
  2121.                          [default: Auto]
  2122.  
  2123. You may select how many data groups or bins are used to
  2124. arrange the data.  The maximum is 20, minimum 1, and an
  2125. auto select option is provided/recommended.
  2126.  
  2127. @
  2128. PIE_OPTIONS_MENU
  2129. A. Data Label Type
  2130. Return to Options Menu
  2131. @
  2132. PIE_OPTIONS_TEXT
  2133.  
  2134. @
  2135. PIE_OPTIONS_HELP
  2136.       PIE, BAR, PARETO Options Help (I.C)
  2137.  
  2138. This menu allows you to affect how the PIE, BAR,
  2139. PARETO, and TABLE charts appear.
  2140.  
  2141. A. Data Label Type (I.C.A) [default: frequency]
  2142.     - This allows you to specify how the PIE, BAR,
  2143.       PARETO, and TABLE charts are labeled with
  2144.       the data values.
  2145.  
  2146. Return
  2147.     - Return to the Options (selection I) menu.
  2148.  
  2149. @
  2150. PIE_DATA_LABEL_MENU
  2151. A. none
  2152. B. frequency
  2153. C. percentage
  2154. Return
  2155. @
  2156. PIE_DATA_LABEL_TEXT
  2157.  
  2158. @
  2159. PIE_DATA_LABEL_HELP
  2160.      PIE, BAR, PARETO Data Labeling Type Help (I.C.A)
  2161.                 [default: frequency]
  2162.           
  2163.  
  2164. This allows you to specify how the PIE, BAR, PARETO,
  2165. and TABLE charts are labeled with the data values.
  2166.  
  2167. A. none (I.C.A.A)
  2168.     - This eliminates the data labels from the output.
  2169.  
  2170. B. frequency (I.C.A.B)
  2171.     - This labels the bar or slice with the actual number
  2172.       of occurances for each data group.
  2173.  
  2174. C. percentage (I.C.A.C)
  2175.     - This labels the bar or slice with the percent of
  2176.       total represented by each data group.
  2177.  
  2178. Return
  2179.     - Return the PIE/BAR/PARETO/TABLE option menu (I.C)
  2180. @
  2181. SCATTER_OPTIONS_MENU
  2182. A. Show X Process Specs ON/OFF
  2183. B. Show Y Process Specs ON/OFF
  2184. C. Eliminate Outliers ON/OFF
  2185. D. Show X Mean ON/OFF
  2186. E. Show X Median ON/OFF
  2187. F. Show Y Mean ON/OFF
  2188. G. Show Y Median ON/OFF
  2189. H. Regression Line ON/OFF
  2190. I. Data Dist Graph Menu 
  2191. Return to OPTIONS Menu
  2192. @
  2193. SCATTER_OPTIONS_TEXT
  2194.  
  2195. @
  2196. SCATTER_OPTIONS_HELP
  2197.                Scatter Diagram Options Help (I.D)
  2198.  
  2199.  
  2200. This allows you to set parameters which affect the statistical
  2201. calculations and appearance of SCATTER DIAGRAMS.  The following
  2202. choices are available:
  2203.  
  2204.  
  2205. A. Show X Process Specs ON/OFF (I.D.A) [default: OFF]
  2206.     - This allows you to plot (or not) the X Process specifications
  2207.       on the scatter diagram.  You can set the X process specs
  2208.       using the PROCESS SPECIFICATIONS menu (selection I.E).
  2209.       X Capability statistics (Cp, Cpk, Cpl, Cpu, etc.) are displayed
  2210.       when both Process Specs (I.D.A) is ON and Summary Stats (I.H.C)
  2211.       is ON.
  2212.  
  2213.  
  2214. B. Show Y Process Specs ON/OFF (I.D.B) [deault: OFF]
  2215.     - This allows you to plot (or not) the Y Process specifications
  2216.       on the scatter diagram.  You can set the Y process specs
  2217.       using the PROCESS SPECIFICATIONS menu (selection I.E).
  2218.       Y Capability statistics (Cp, Cpk, Cpl, Cpu, etc.) are displayed
  2219.       when both Process Specs (I.D.A) is ON and Summary Stats (I.H.C)
  2220.       is ON.
  2221.  
  2222.  
  2223. C. Eliminate Outliers ON/OFF (I.D.C) [deault: OFF]
  2224.     - You can designate any data points in the data file for the
  2225.       scatter diagram as "outliers" (e.g. ! 25 10, etc.).  When
  2226.       eliminate outliers is ON, points defined as outliers will be
  2227.       highlighted and will not be used in the calculations.
  2228.       
  2229.  
  2230. D. Show X Mean ON/OFF (I.D.D) [deault: OFF]
  2231.     - You may choose to plot or not the mean (average) of the X
  2232.       values on the scatter diagram.
  2233.       
  2234.  
  2235. E. Show X Median ON/OFF (I.D.E) [deault: OFF]
  2236.     - You may choose to plot or not the median of the X values
  2237.       on the scatter diagram.
  2238.  
  2239.  
  2240. F. Show Y Mean ON/OFF (I.D.F) [deault: OFF]
  2241.     - You may choose to plot or not the mean (average) of the Y
  2242.       values on the scatter diagram.
  2243.  
  2244.  
  2245. G. Show Y Median ON/OFF (I.D.G) [deault: OFF]
  2246.     - You may choose to plot or not the median of the Y values
  2247.       on the scatter diagram.
  2248.  
  2249.  
  2250. H. Regression Line ON/OFF (I.D.H) [deault: OFF]
  2251.     - This option allows you to plot (or not) the linear regression
  2252.       line calculated from the data points in the data file.
  2253.       Regression statistics (r-squared, F-test, t-test, regression
  2254.       coefficients, etc.) are displayed when both Scatter Diagram
  2255.       regression (I.D.H) is ON and Summary Stats (I.H.C) is ON.
  2256.  
  2257.  
  2258. I. Data Dist Graph Menu (I.D.I) [default: none]
  2259.     - This feature allows you to select a data distribution function
  2260.       (HISTOGRAM, POLYGON, or CDF) to display along with the scatter
  2261.       diagram.  Two distribution graphics are displayed -  one for
  2262.       the X values and one for the Y values.
  2263.        
  2264.  
  2265. Return to OPTIONS Menu
  2266.  
  2267.  
  2268. @
  2269. SCATTER_DIST_MENU
  2270. A. none
  2271. B. Histogram
  2272. C. Frequency Polygon
  2273. D. Ogive (CDF)
  2274. Return
  2275. @
  2276. SCATTER_DIST_TEXT
  2277.  
  2278. @
  2279. SCATTER_DIST_HELP
  2280.       Scatter Diagram Distribution Graph Type Help (I.D.I)
  2281.                        [default: none]
  2282.  
  2283. This feature allows you to select a data distribution function
  2284. (HISTOGRAM, POLYGON, or CDF) to display along with the scatter
  2285. diagram.  Two distribution graphics are displayed -  one for
  2286. the X values and one for the Y values.
  2287.  
  2288.  
  2289. A. none
  2290.     - No distribution graphs are displayed with the scatter
  2291.       diagram.
  2292.  
  2293. B. Histogram
  2294.     - Two HISTOGRAMS are displayed with the scatter diagram.
  2295.       
  2296.  
  2297. C. Frequency Polygon
  2298.     - Two frequency POLYGONS are displayed with the scatter
  2299.       diagram.
  2300.       
  2301.  
  2302. D. Ogive (CDF)
  2303.     - Two ogives (CDFs) are displayed with the scatter diagram.
  2304.  
  2305.  
  2306. Return
  2307.     - Return the the SCATTER diagram options menu (I.D).
  2308.  
  2309. @
  2310. SPECS_OPTIONS_MENU
  2311. A. USL
  2312. B. LSL
  2313. C. Nominal
  2314. D. USL (Y) Scatter Only
  2315. E. LSL (Y) Scatter Only
  2316. F. Nominal (Y) Scatter Only
  2317. G. Pop Sigma Est. Type
  2318. Return to OPTIONS Menu
  2319. @
  2320. SPECS_OPTIONS_TEXT
  2321.  
  2322. @
  2323. SPECS_OPTIONS_HELP
  2324.                 Process Specifications Menu Help (I.E)
  2325.  
  2326. Use this menu to set the process specifications and method for
  2327. estimating the population standard deviation for all control
  2328. charts, distribution graphics, and scatter diagrams.  These
  2329. process specifications are saved with all of the other options.
  2330. Select from the following options:
  2331.  
  2332.  
  2333. A. USL (I.E.A) [default: 0.0]
  2334.     - Use this to set the USL for all control charts, Histograms,
  2335.       Polygons, CDFs (Ogives), and the X variable on scatter
  2336.       diagrams.  Any number from -10^7 to +10^7 may be entered.
  2337.  
  2338. B. LSL (I.E.B) [default: 0.0]
  2339.     - Use this to set the LSL for all control charts, Histograms,
  2340.       Polygons, CDFs (Ogives), and the X variable on scatter
  2341.       diagrams.  Any number from -10^7 to +10^7 may be entered.
  2342.  
  2343. C. Nominal (I.E.C) [default: 0.0]
  2344.     - Use this to set the nominal process value for all control
  2345.       charts, Histograms, Polygons, CDFs (Ogives), and the X
  2346.       variable on scatter diagrams.  Any number from -10^7 to
  2347.       +10^7 may be entered.
  2348.  
  2349.            *** This is not used in this version of SPC EXpert.
  2350.  
  2351. D. USL (Y) Scatter Only (I.E.D) [default: 0.0]
  2352.     - Use this to set the USL value for the Y variable on scatter
  2353.       diagrams.  Any number from -10^7 to +10^7 may be entered.
  2354.  
  2355.  
  2356. E. LSL (Y) Scatter Only (I.E.E) [default: 0.0]
  2357.     - Use this to set the LSL value for the Y variable on scatter
  2358.       diagrams.  Any number from -10^7 to +10^7 may be entered.
  2359.  
  2360.  
  2361. F. Nominal (Y) Scatter Only (I.E.F) [default: 0.0]
  2362.     - Use this to set the nominal process value for the Y variable
  2363.       on scatter diagrams.  Any number from -10^7 to +10^7 may
  2364.       be entered.
  2365.  
  2366.            *** This is not used in this version of SPC EXpert.
  2367.  
  2368.  
  2369. G. Pop Sigma Est. Type (I.E.G) [default: sigma(n-1)]
  2370.     - You may select the method used to estimate the population
  2371.       standard deviation when calculating capability statistics.
  2372.       
  2373.  
  2374. Return to OPTIONS Menu
  2375.  
  2376. @
  2377. POP_SIGMA_EST_MENU
  2378. A. Table Lookup
  2379. B. Pop Sigma(n)
  2380. C. Pop Sigma(n-1)
  2381. D. User Defined
  2382. @
  2383. POP_SIGMA_EST_TEXT
  2384. @
  2385. POP_SIGMA_EST_HELP
  2386.  Population Standard Deviation Estimate Method Help (I.E.G)
  2387.                 [default: Pop Sigma(n-1)]
  2388.                 
  2389. You may select the method used to estimate the population
  2390. standard deviation when calculating capability statistics.
  2391. The following options are available:
  2392.  
  2393.  
  2394. A. Table Lookup (I.E.G.A)
  2395.     - This method approximates the standard deviation of the
  2396.       population using statistical tables or formulas commonly
  2397.       cited in textbooks.
  2398.  
  2399. B. Pop Sigma(n) (I.E.G.B)
  2400.     - This method approximates the standard deviation of the
  2401.       population using the standard deviation of the individual
  2402.       samples with n degrees of freedom.
  2403.  
  2404. C. Pop Sigma(n-1) (I.E.G.C)
  2405.     - This method approximates the standard deviation of the
  2406.       population using the standard deviation of the individual
  2407.       samples with n-1 degrees of freedom.
  2408.  
  2409. D. User Defined (I.E.G.D)
  2410.     - This method allows you to directly specify the standard
  2411.       deviation of the population.  This method is NOT
  2412.       RECOMMENDED!  Use at your own risk.
  2413. @
  2414. RAW_DATA_OPTIONS_MENU
  2415. A. SPC EXpert Format
  2416. B. USAF SPC 1.1 Format
  2417. C. USAF SPC 1.2 Format
  2418. Return to OPTIONS Menu
  2419. @
  2420. RAW_DATA_OPTIONS_TEXT
  2421.  
  2422. @
  2423. RAW_DATA_OPTIONS_HELP
  2424.               Data File Format Type help (I.F)
  2425.                 [default: SPC EXpert Format]
  2426.  
  2427. This option allows you to select the version format of data files
  2428. imported.  This option is included to allow for both the extension
  2429. of SPX EXpert data file formats and to allow in the future,
  2430. additional formats which can be imported into SPC EXpert such as
  2431. DBase-type files, etc.  The following data file formats are supported:
  2432.  
  2433.  
  2434. A. SPC EXpert Format (I.F.A)
  2435.     - This is the data file format described in the SPC EXpert
  2436.       software users manual.
  2437.       
  2438.  
  2439. B. USAF SPC 1.1 Format (I.F.B)
  2440.     - This is the data file format used in the Air Force's Statistical
  2441.       Process Control Software (SPC Version 1.1 - March 1992).  SPC
  2442.       Version 1.1 is available only to Department of Defense Agencies.
  2443.  
  2444. C. USAF SPC 1.2 Format (I.F.C)
  2445.     - This is the data file format used in the Air Force's Statistical
  2446.       Process Control Software (SPC Version 1.2 - October 1992).  SPC
  2447.       Version 1.2 is available only to Department of Defense Agencies.
  2448.  
  2449.           *** SPC EXpert's data file formats were patterned directly
  2450.               after the USAF SPC 1.2 raw data file formats.
  2451. @
  2452. FONTS_OPTIONS_MENU
  2453. A. Titles Font
  2454. B. Titles Font Size
  2455. C. Axes Labels Font
  2456. D. Axes Labels Font Sizes
  2457. Return to OPTIONS Menu
  2458. @
  2459. FONTS_OPTIONS_TEXT
  2460.  
  2461. @
  2462. FONTS_OPTIONS_HELP
  2463.                      FONTS Options Help (I.G)
  2464.                      
  2465.  
  2466. You may select the font and font size for both the Titles/Subtitles
  2467. and X and Y Axis labels.  The following options are available:
  2468.  
  2469. A. Titles Font (I.G.A) [default: Stroked Small]
  2470.     - You may select the type of text font used in the title and
  2471.       subtitle of all graphics.  The following fonts are available:
  2472.       
  2473.                  A. 8x8 bit-mapped
  2474.                  B. Stroked triplex
  2475.                  C. Stroked small
  2476.                  D. Stroked sans-serif
  2477.                  E. Stroked gothic
  2478.  
  2479.  
  2480. B. Titles Font Size (I.G.B) [default: Auto]
  2481.     - You may select the type of text font used in the title and
  2482.       subtitle of all graphics.  The sizes available include:
  2483.       "0. Auto" or "1 - 10".  "Auto" selects the font size to fit
  2484.       the title length to the screen width and height.  "1" - "10"
  2485.       determines the relative size of the font from small ("1") to
  2486.       large ("10").
  2487.  
  2488. C. Axes Labels Font (I.G.C) [default: Stroked Small]
  2489.     - You may select the type of text font used in the X and Y axis
  2490.       labels of all graphics.  The following fonts are available:
  2491.       
  2492.                  A. 8x8 bit-mapped
  2493.                  B. Stroked triplex
  2494.                  C. Stroked small
  2495.                  D. Stroked sans-serif
  2496.                  E. Stroked gothic
  2497.  
  2498.  
  2499. D. Axes Labels Font Sizes (I.G.D) [default: Auto]
  2500.     - You may select the type of text font used in the X and Y axis
  2501.       labels of all graphics.  The sizes available include:
  2502.       "0. Auto" or "1 - 10".  "Auto" selects the font size to fit
  2503.       the title length to the screen width and height.  "1" - "10"
  2504.       determines the relative size of the font from small ("1") to
  2505.       large ("10").
  2506.  
  2507. Return to OPTIONS Menu
  2508.  
  2509. @
  2510. DISPLAY_OPTIONS_MENU
  2511. A. Titles ON/OFF
  2512. B. Enhanced Print ON/OFF
  2513. C. Summary Stats ON/OFF
  2514. D. Sound ON/OFF
  2515. Return to OPTIONS Menu
  2516. @
  2517. DISPLAY_OPTIONS_TEXT
  2518.  
  2519. @
  2520. DISPLAY_OPTIONS_HELP
  2521.          General Display Characteristics Help (I.H)
  2522.  
  2523. This allows you to set parameters which affect all types of
  2524. charts and diagrams.  These include:
  2525.  
  2526.  
  2527. A. Titles ON/OFF (I.H.A) [default: ON]
  2528.     - Use this option to toggle ON/OFF the display of the Title
  2529.       and subtitle for all charts and diagrams.
  2530.       
  2531.  
  2532. B. Enhanced Print ON/OFF (I.H.B) [default: OFF]
  2533.     - Use this option to toggle ON/OFF the display of detailed
  2534.       information for all charts and diagrams.  This information
  2535.       includes such things as file name, file date, chart type,
  2536.       print date, etc.
  2537.  
  2538.  
  2539. C. Summary Stats ON/OFF (I.H.C) [default: OFF]
  2540.     - Use this option to toggle ON/OFF the display of a summary 
  2541.       statistics box on the graphic of all charts and diagrams.
  2542.  
  2543.       *** This option must be ON to view any of the specialized
  2544.           statistics such as regression and capability stats.
  2545.           
  2546.  
  2547. D. Sound ON/OFF (I.H.D) [default: ON]
  2548.     - Use this option to toggle ON/OFF the sound (beeps) in SPCEX.
  2549.     
  2550.  
  2551. Return to OPTIONS Menu
  2552.  
  2553. @
  2554. SAVE_CFG_OPTIONS_MENU
  2555. A. Save Options for Start-ups
  2556. B. Save Options to File
  2557. C. Load Start-up Options
  2558. D. Load Options from File
  2559. E. Reset Options to Defaults
  2560. Return to OPTIONS Menu
  2561. @
  2562. SAVE_CFG_OPTIONS_TEXT
  2563. @
  2564. SAVE_CFG_OPTIONS_HELP
  2565.              Save\retrieve Options File Help (I.I)
  2566.  
  2567. Current and past settings for options may be saved and recalled
  2568. for future use using this menu.  In particular, you can use this
  2569. menu to save the current options settings to a named (provided
  2570. by you) file (I.I.B) which can be later specifically referenced
  2571. in a data file ( *<file-name> on first line ).
  2572.  
  2573. A. Save Options for Start-ups (I.I.A)
  2574.     - This feature saves the current option settings to a default
  2575.       "options file" which is loaded every time you start the program.
  2576.       The default options file contains the option default settings
  2577.       until you chang it using this option (I.I.A).
  2578.  
  2579.  
  2580. B. Save Options to File (I.I.B)
  2581.     - Current option settings may also be saved to an "options file"
  2582.       named by you.  This file can be used with Multiple Chart files
  2583.       to display the output using the specified options file.  If the
  2584.       special "options file" is to be used for all charts/graphs in
  2585.       the Multiple Chart, the filename would appear in the first line
  2586.       with an asterisk next to it.  For example, if the special "options
  2587.       file" is called "myopts.cfg", a Multiple Chart file may look like
  2588.       this:
  2589.  
  2590.                     *myopts.cfg
  2591.                     Title
  2592.                     Subtitle
  2593.                     GPA.DAT BAR
  2594.                     GPA.DAT PARETO
  2595.                     GPA.DAT PIE
  2596.       
  2597.       If the special "options file" is to be used for a specific chart
  2598.       or graph the file name is entered after the chart type.  The
  2599.       Multiple Chart data file may look like this:
  2600.  
  2601.                     Title
  2602.                     Subtitle
  2603.                     GPA.DAT BAR
  2604.                     GPA.DAT PARETO myopts.cfg
  2605.                     GPA.DAT PIE
  2606.  
  2607.  
  2608. C. Load Start-up Options (I.I.C)
  2609.     - Use this to load the Start-up options file.  This is the file
  2610.       updated using selection (I.I.A).
  2611.  
  2612.  
  2613. D. Load Options from File (I.I.D)
  2614.     - Current options settings may also be saved to an "Options" file
  2615.       that you name/create (I.I.B).  Use this option to load a 
  2616.       user-defined options file.
  2617.  
  2618.  
  2619. E. Reset Options to Defaults (I.I.E)
  2620.     - You may also easily reset all the options to the original SPCEX
  2621.       software default settings using this selection.  This is 
  2622.       particularly useful if you have changed a lot of options and
  2623.       want to start over with the default settings.
  2624.       
  2625.       ***  This does not affect the options settings in the Start-up
  2626.            options file that are loaded when the program is re-started. 
  2627.            You must save the default settings (I.I.A) after resetting
  2628.            the options to their defaul to change the start-up settings.
  2629. @
  2630. FONT_TEXT
  2631. Select a font for
  2632. titles & subtitles
  2633. @
  2634. FONT_MENU
  2635. A. 8x8 bit-mapped
  2636. B. Stroked triplex
  2637. C. Stroked small
  2638. D. Stroked sans-serif
  2639. E. Stroked gothic
  2640. Return
  2641. @
  2642. FONT_HELP
  2643.         FONT Definition Help Screen
  2644.  
  2645. This choice is a matter of personal taste.  The SPCEX
  2646. system default is B. Stroked triplex.
  2647. @
  2648. TEXT_TEXT
  2649. Select a font for
  2650. Non-Titles Text
  2651. @
  2652. TEXT_HELP
  2653. Non-Titles FONT Definition Help Screen  -  Not Developed Yet.
  2654.  
  2655. This choice is a matter of personal taste.  The SPCEX
  2656. system default is A. 8x8 Bit mapped.
  2657. @
  2658. FONTSIZE_MENU
  2659. 0 (Auto)
  2660. 1
  2661. 2
  2662. 3
  2663. 4
  2664. 5
  2665. 6
  2666. 7
  2667. 8
  2668. 9
  2669. 10
  2670. Return
  2671. @
  2672. FONTSIZE_TEXT
  2673. Select a text size scaling factor.
  2674. @
  2675. FONTSIZE_HELP
  2676.    Titles Text size scaling factor Help Screen
  2677.  
  2678.  
  2679. This choice is a matter of personal taste.  The SPCEX
  2680. system default is 0 Automatic scaling.
  2681. @
  2682. EDIT_TEXT
  2683. Select a File Manager Option
  2684. @
  2685. EDIT_MENU
  2686. A. Edit Current Data File
  2687. B. Create/Edit A File
  2688. C. View A File
  2689. D. Copy A File
  2690. E. Rename A File
  2691. F. Delete A File
  2692. Return to MAIN MENU
  2693. @
  2694. EDIT_HELP
  2695.      SPC EXpert Editor & File Manager
  2696.  
  2697. SPC EXpert provides you with an integrated editor to
  2698. create or modify data files.  The editor is currently
  2699. limited to a maximum of 16000 lines by 70 columns.
  2700.  
  2701. SPC EXpert also provides the file management functions to
  2702. VIEW, COPY, RENAME, and DELETE a file.
  2703. @
  2704. editor_quest
  2705. Enter the name of the
  2706. file you wish to edit.
  2707. @
  2708. demo_help
  2709.             STATISTICAL PROCESS CONTROL SOFTWARE
  2710.               
  2711.                        SPC EXpert
  2712.  
  2713. Developed by:
  2714.  
  2715.                Quality Software Designs, Inc.
  2716.                   933 East Stroop Road
  2717.                  Kettering, Ohio 45429
  2718.  
  2719.                   DEMONSTRATION PROGRAM
  2720.  
  2721. Several Sample data sets (options C - Y) have been included
  2722. for demonstration purposes.  Option B is a repeating display
  2723. of all of the graphs/diagrams produced by SPCEX.  Option A
  2724. allows you to use SPC EXpert with your own data. Select
  2725. the last option to quit.
  2726.  
  2727. The following ASCII files contain the sample data :
  2728.  
  2729.                (C) #trun.dmo#t
  2730.                       #u<graphic>;RUN run.dmo default.cfg#u RUN Chart
  2731.                (D) #tr.dmo#t
  2732.                       #u<graphic>;XBAR r.dmo default.cfg#u XBAR Chart
  2733.                (E) #tr.dmo#t
  2734.                       #u<graphic>;R r.dmo default.cfg#u R Chart
  2735.                (F) #ts.dmo#t
  2736.                       #u<graphic>;S s.dmo default.cfg#u S Chart
  2737.                (G) #trun.dmo#t
  2738.                       #u<graphic>;MR run.dmo default.cfg#u MR Chart
  2739.                (H) #tr.dmo#t
  2740.                       #u<graphic>;XBAR_R r.dmo default.cfg#u XBAR_R Chart
  2741.                (I) #ts.dmo#t  
  2742.                       #u<graphic>;XBAR_S s.dmo default.cfg#u XBAR_S Chart
  2743.                (J) #trun.dmo#t
  2744.                       #u<graphic>;XMR run.dmo default.cfg#u XMR Chart
  2745.                (K) #tp.dmo#t
  2746.                       #u<graphic>;P p.dmo default.cfg#u P Chart
  2747.                (L) #tpn.dmo#t
  2748.                       #u<graphic>;PN pn.dmo default.cfg#u PN Chart
  2749.                (M) #tc.dmo#t
  2750.                       #u<graphic>;C c.dmo default.cfg#u C Chart
  2751.                (N) #tu.dmo#t
  2752.                       #u<graphic>;U u.dmo default.cfg#u U Chart
  2753.                (O) #tbar.dmo#t
  2754.                       #u<graphic>;BAR bar.dmo default.cfg#u Bar Graph
  2755.                (P) #tbar.dmo#t
  2756.                       #u<graphic>;PARETO bar.dmo default.cfg#u PARETO Diagram
  2757.                (Q) #tbar.dmo#t
  2758.                       #u<graphic>;PIE bar.dmo default.cfg#u PIE Chart
  2759.                (R) #tbar.dmo#t
  2760.                       #u<graphic>;TABLE bar.dmo default.cfg#u TABLE Chart
  2761.                (S) #trun.dmo#t
  2762.                       #u<graphic>;HISTOGRAM run.dmo default.cfg#u HISTOGRAM
  2763.                (T) #trun.dmo#t
  2764.                       #u<graphic>;POLYGON run.dmo default.cfg#u frequency POLYGON
  2765.                (U) #trun.dmo#t
  2766.                       #u<graphic>;CDF run.dmo default.cfg#u CDF
  2767.                (V) #tscat.dmo#t
  2768.                       #u<graphic>;SCATTER scat.dmo default.cfg#u SCATTER DIAGRAM
  2769.                (W) #tmulti3.dmo#t
  2770.                       #u<graphic>;MULTIPLE multi3.dmo default.cfg#u MULTIPLE CHART
  2771.                (X) #tmulti2.dmo#t
  2772.                       #u<graphic>;MULTIPLE multi2.dmo default.cfg#u MULTIPLE CHART
  2773.                (Y) #tmulti1.dmo#t
  2774.                       #u<graphic>;MULTIPLE multi1.dmo default.cfg#u MULTIPLE CHART
  2775. @
  2776. WAIT_MESSAGE
  2777. One Moment Please ...
  2778.  
  2779.     Loading SPC EXpert
  2780.  
  2781.  
  2782. Quality Software Designs, Inc.
  2783. 933 East Stroop Road
  2784. Kettering, Ohio 45429
  2785. @
  2786. DEMO_MENU
  2787. A. SPC EXpert Tool
  2788. B. Screen Show
  2789. C. Run Chart
  2790. D. Xbar Chart
  2791. E. R Chart
  2792. F. S Chart
  2793. G. Moving Range Chart
  2794. H. Xbar-R Chart
  2795. I. Xbar-S Chart
  2796. J. X Moving Range Chart
  2797. K. P Chart
  2798. L. PN Chart
  2799. M. C Chart
  2800. N. U Chart
  2801. O. Bar Chart
  2802. P. Pareto Diagram
  2803. Q. Pie Chart
  2804. R. Table
  2805. S. Histogram (Frequency Dist)
  2806. T. Frequency Polygon
  2807. U. Ogive (CDF)
  2808. V. Scatter Diagram
  2809. W. Multiple Chart
  2810. X. Multiple Chart
  2811. Y. Multiple Chart
  2812. exit demonstration
  2813. @
  2814. DEMO_TEXT
  2815.      SPC EXpert
  2816.    DEMONSTRATION
  2817.  
  2818.  
  2819. Quality Software Designs, Inc.
  2820. 933 East Stroop Road
  2821. Kettering, Ohio 45429
  2822. messages: (513) 299-3023
  2823. email:    marks@meaddata.com
  2824.        ...!uunet!meaddata!marks
  2825.  
  2826. Select a Sample data set  ->
  2827. @
  2828. DEMO_DEMO_TEXT
  2829. SPC EXpert DEMONSTRATION
  2830.  
  2831.  
  2832. For a fully functional registered
  2833. copy of SPC EXpert, send the
  2834. appropriate licensing fees to
  2835.  
  2836.  
  2837. Quality Software Designs, Inc.
  2838. 933 East Stroop Road
  2839. Kettering, Ohio 45429
  2840.  
  2841.  
  2842. Select a Sample data set  ->
  2843. @
  2844. DEMO_TYPE_FILES
  2845. RUN run.dmo
  2846. XBAR r.dmo
  2847. R r.dmo
  2848. S s.dmo
  2849. MR run.dmo
  2850. XBAR_R r.dmo
  2851. XBAR_S s.dmo
  2852. XMR run.dmo
  2853. P p.dmo
  2854. PN pn.dmo
  2855. C c.dmo
  2856. U u.dmo
  2857. BAR bar.dmo
  2858. PARETO bar.dmo
  2859. PIE bar.dmo
  2860. TABLE bar.dmo
  2861. HISTOGRAM run.dmo
  2862. POLYGON run.dmo
  2863. CDF run.dmo
  2864. SCATTER scat.dmo
  2865. MULTIPLE multi3.dmo
  2866. MULTIPLE multi2.dmo
  2867. MULTIPLE multi1.dmo
  2868. @
  2869. VIDEO_OPTIONS_MENU
  2870. A. Auto Detect (Recommended)
  2871. B. CGA LOW 320x200
  2872. C. CGA HIGH 640x200
  2873. D. MCGA LOW 320x200
  2874. E. MCGA MED 640x200
  2875. F. MCGA HIGH 640x480
  2876. G. EGA LOW 640x200
  2877. H. EGA HIGH 640x350
  2878. I. EGA64 LOW 640x200
  2879. J. EGA64 HIGH 640x350
  2880. K. HERCULES MONO 720x348
  2881. L. ATT400 LOW 320x200
  2882. M. ATT400 MED 640x200
  2883. N. ATT400 HIGH 640x400
  2884. O. VGA LOW 640x200
  2885. P. VGA MED 640x350
  2886. Q. VGA HIGH 640x480
  2887. R. PC3270 720x350
  2888. S. IBM8514 LOW 640x480
  2889. T. IBM8514 HIGH 1024x768
  2890. return
  2891. @
  2892. VIDEO_OPTIONS_TEXT
  2893. @
  2894. VIDEO_OPTIONS_HELP
  2895. This option is only recommended if you
  2896. are haveing problems displaying graphics
  2897. on you monitor.
  2898.  
  2899. A. Auto Detect - is RECOMMENDED!
  2900. @
  2901. MENU_NOTATION
  2902.                  (X.Y.Z) MENU NOTATION
  2903.     
  2904. The documentation and HELP screens in SPC EXpert use a special
  2905. notation to specify a sequence of menu selections beginning
  2906. from the MAIN MENU.  This notation will simplify instructions
  2907. for navigating through the SPC EXpert menus.
  2908.  
  2909.  
  2910. For example, to view the current options settings, you
  2911. would select (I.J) by
  2912.  
  2913.      1. Start From SPCEX MAIN MENU
  2914.      2. Select item I, "I. Options"
  2915.           - Now you are in the OPTIONS MENU
  2916.      3. Select item J, "J. Display Current Options"
  2917.  
  2918.  
  2919. Another example, to set the method of computing a control chart
  2920. center line to "Median", you would select (I.A.D.B) by
  2921.  
  2922.      1. Start From SPCEX MAIN MENU
  2923.      2. Select item I, "I. Options"
  2924.           - Now you are in the OPTIONS MENU
  2925.      3. Select item A, "A. Control Charts"
  2926.           - Now you are in the CONTROL CHART OPTIONS MENU
  2927.      4. Select item D, "D. Center Line Method"
  2928.      5. Select item B, "B. Median"
  2929.      
  2930. @
  2931. EDITOR_HELP
  2932.                      SPC EXpert EDITOR
  2933.  
  2934. <F1>      - Help                   <RETURN>     - Insert Line
  2935.                                              (When Insert Is ON)
  2936. |         - Up 1 line              <F4> - Data File Formats
  2937. |         - Down 1 line                                      
  2938. -         - Right 1 Character      <F3>         - Delete Line
  2939. -         - Left 1 Character       Delete       - Delete Char
  2940.                                    Backspace    - Delete Previous
  2941. PgUp      - Up one page                           Char
  2942. PgDn      - Down one page
  2943.                                       Insert    - Toggle Between
  2944. Home      - Beginning of Line                     Insert Mode and
  2945. End       - End of Line                           Overwrite Mode
  2946.  
  2947. <F2>      - Save File and Exit           Maximum Lines/Rows :
  2948. Esc       - Exit Without Save            Maximum Columns    :
  2949. @
  2950. TRANSFER_FILES
  2951. bar.dmo
  2952. run.dmo
  2953. default.cfg
  2954. notitles.cfg
  2955. @
  2956. SHELL_COMMAND