home *** CD-ROM | disk | FTP | other *** search
/ Explore the World of Soft…e: Engineering & Science / Explore_the_World_of_Software_Engineering_and_Science_HRS_Software_1998.iso / programs / statistc / spcex21s.exe / INFO.HYP < prev    next >
Text File  |  1993-06-10  |  43KB  |  1,253 lines

  1. @
  2. MORE_INFO_MENU
  3.                  ON LINE DOCUMENTATION
  4.  
  5. #m>HELP<;hypertext help#m - Click on the >HELP< or Press Enter to learn
  6.          how to operate the hypertext help system.
  7.  
  8.     #m(X.Y.Z);MENU_NOTATION;screens.hyp#m SPC EXpert menu navigation notation.
  9.     
  10.          #mA. SPC EXpert Licensing Information;system0#m
  11.          #mB. SPC EXpert Custom Enhancement Services;custom#m
  12.          #mC. Technical/Customer Support;support#m
  13.          #mD. Addressing email feedback;email#m
  14.          #mE. Planned Enhancements to SPC EXpert;enhance#m
  15.          #mF. SPC Abbreviations;SPC Abbreviations;define.hyp#m
  16.          #mG. SPC Definitions;SPC Definitions;define.hyp#m
  17.          #mH. SPC EXpert system overview;system1#m
  18.          #mI. Data File Formats;format1#m
  19.          #mJ. Graphs/Diagrams Overview;graph0#m
  20.          #mK. Control Charts Overview;charts0#m
  21.          #mL. On line SPC EXpert User's Manual;users manual;manual.hyp#m
  22. @
  23. email
  24.                    Sending Electronic Mail
  25.  
  26. You are strongly encouraged to send your comments or questions via
  27. electronic mail since telephone support will only be available from
  28. 6:00pm-9:00pm Eastern time.
  29.  
  30.                  EMAIL : marks@meaddata.com
  31.  
  32. If this does not work, you may need to try the alternative email
  33. addressing format as follows:
  34.  
  35.                 ...!uunet!meaddata!marks
  36.  
  37. That is, once you can get your message to UUNET, it can get to us.
  38. Now, if your email system "knows" UUNET, then the following may work:
  39.  
  40.                     uunet!meaddata!marks
  41.                     
  42. However, if this does not work, you may need to add another system name
  43. to this email address.  For example, if your full email address is
  44. myname@abc.def.GOV, then you might try using the following email address:
  45.  
  46.                   gov!uunet!meaddata!marks
  47.                   
  48. Other possibilities include:
  49.  
  50.                   mil!uunet!meaddata!marks
  51.                   edu!uunet!meaddata!marks
  52.                   net!uunet!meaddata!marks
  53. @
  54. system0
  55.   SPC EXpert - Copyright Quality Software Designs, Inc. 1993
  56.  
  57. SPC EXpert is a SHAREWARE product.  You may freely reproduce and
  58. re-distribute SPC EXpert for evaluation, educational, and
  59. governmental purposes.  If you make commercial use of this software,
  60. you are expected to pay a licensing fee as outlined below.  Upon
  61. receipt of your licensing fee you will receive a printed manual, a
  62. license agreement, and notices of future upgrades to the software.
  63. *Academic and federal,state & local government agencies may use and
  64. re-distribute SPC EXpert without charge (FREE) but should register.
  65.  
  66. Individual User($40);PC LAN($100);Site License($200);*Academic(FREE)
  67. Mutli-Site License($500); *Federal, state, & local Government(FREE)
  68.  
  69. ** Send Check or money order to    Quality Software Designs Inc
  70.                                    933 East Stroop Road
  71.      phone: (513) 299-3023         Kettering OH 45429       USA
  72. @
  73. custom
  74.                 SPC EXpert Custom Enhancement Services
  75.  
  76. Quality Software Designs, Inc., can provide you with a custom enhanced
  77. version of SPC EXpert tailored to your specific needs.  In many cases,
  78. a tailor-made version of SPC EXpert can be produced at a cost comparable
  79. to the single-copy off-the-shelf cost of commercial SPC software products.
  80. To inquire about this service, contact:
  81.  
  82.                      Quality Software Designs, Inc.
  83.                      933 East Stroop Road
  84.                      Kettering, Ohio 45429
  85.                      (513) 299-3023
  86.                      email: marks@meaddata.com  or
  87.                             ...!uunet!meaddata!marks
  88.  
  89.                             
  90. Possible areas for customization include,
  91.  
  92. 1. Placing domain-specific advice in the expert consultation text.
  93.    e.g. In place of
  94.                    "A shift-up in the R chart means that your
  95.                     process has become less consistent..."
  96.         we display
  97.                    "A shift-up in the R chart has historically been
  98.                     caused (90%) by a loose ball bearing in the
  99.                     preprocessing machine."
  100.                     
  101. 2. Placing company-specific terminology and text in the help screens
  102.    and expert consultation text.
  103.    
  104. 3. Translating SPC EXpert into another non-English language.
  105.  
  106. 4. Adding a unique type of statistical/graphical tool.
  107.  
  108. Remember, Quality Software Designs, Inc., is in the business of
  109. providing Custom Software Solutions.  When you consider which
  110. SPC software package to buy, call up the commercial vendors and
  111. ask then if their $200-$1000 per copy price-tag includes such
  112. customer-driven tailoring.
  113. @
  114. support
  115.              SPC EXpert Technical/Customer Support
  116.  
  117. 1. Phone support is available 6:00pm-9:00pm eastern time (513) 299-3023
  118.  
  119. 2. Messages can be left on an answering machine which is regularly
  120.    checked all day, every day.  (513) 299-3023
  121.    
  122. 3. Questions and detailed problem reports can be sent over the INTERNET
  123.    (email) to  marks@meaddata.com  or  ...!uunet!meaddata!marks
  124.  
  125. 4. Send written comments and questions to
  126.  
  127.                  Quality Software Designs, Inc.
  128.                  933 East Stroop Road
  129.                  Kettering, Ohio 45429
  130.  
  131. Suggestions are strongly encouraged.  Without your help and feedback,
  132. we cannot improve SPC EXpert to better meet your (changing) needs.
  133. @
  134. enhance
  135. Planned Enhancements To SPC EXpert
  136.  
  137. SHORT TERM
  138.  
  139.     S.1 Include Short-Run Control Charts
  140.         a. Nominal Xbar-R
  141.         b. Target Xbar-R
  142.         c. Short Run X-Bar-R
  143.         d. Short Run XMR
  144.         e. Short Run Moving Average Moving Range
  145.         f. Short Run C
  146.         g. Short Run U
  147.         h. Short Run NP
  148.         i. Short Run P
  149.         j. Standardized S Chart
  150.         
  151.     S.2 Include Variable Sub-group Size Xbar-R & Xbar-S Charts 
  152.  
  153.     S.3 "Multiple" Versions of existing tools
  154.         a. multi bar graph
  155.         b. stacked bar graph
  156.         c. stacked pareto diagram
  157.         d. multi line (run chart) graph
  158.  
  159. MID TERM
  160.  
  161.     M.1 MicroSoft Windows Based Version 
  162.  
  163.     M.2 Import Data from Properly Structured DBase-Type FIles
  164.            - The database structure for each type of
  165.              control chart or graphic will be specifically
  166.              given in the documentation.
  167.  
  168. LONG TERM
  169.  
  170.     L.1 "Real-Time" Data Analysis and Monitoring
  171.     
  172.     L.2 Macintosh Version
  173.  
  174.     L.3 MicroSoft Windows Based Graphical TQM Tools
  175.         a. Flow-Charting
  176.         b. Fish-bone Diagrams
  177.         c. Cause & Effect Diagrams
  178.         d. Organizational Charts 
  179. @
  180. format1
  181.         SPC EXpert
  182.  
  183.      DATA FILE FORMATS
  184.  
  185.      #mGeneral;format2#m
  186.  
  187.          #mRun Charts;format3#m
  188.          #mMR Charts;format3#m
  189.          #mXMR Charts;format3#m
  190.          #mXBAR Charts;format6#m
  191.          #mR Charts;format6#m
  192.          #mS Charts;format6#m
  193.          #mXBAR-R Charts;format6#m
  194.          #mXBAR-S Charts;format6#m
  195.          #mPN Charts;format9#m
  196.          #mP Charts;format11#m
  197.          #mC Charts;format13#m
  198.          #mU Charts;format15#m
  199.          #mBar Graphs;format17#m
  200.          #mPareto Diagrams;format17#m
  201.          #mPie Charts;format17#m
  202.          #mTables;format17#m
  203.          #mHistograms;format3#m
  204.          #mFrequency Polygons;format3#m
  205.          #mOgives;format3#m
  206.          #mScatter Diagrams;format26#m
  207.          #mMultiple Charts;format28#m
  208. @
  209. format2
  210.                     DATA FILE FORMATS
  211.  
  212. 1. SPCEX will generate 11 different types of control charts
  213.    - RUN,XBAR,R,S,MR,XBAR_R,XBAR_S,XMR,PN,P,C,U.
  214.    
  215. 2. SPCEX will generate 8 different types of diagrams/graphs 
  216.    - BAR, PARETO, PIE, data TABLE, HISTOGRAM Frequency
  217.      POLYGON, Ogive (CDF) and SCATTER diagram.
  218.      
  219. 3. Each type of chart/diagram requires a slightly different
  220.    format for the ASCII file which contains the process data.
  221.  
  222. 4. The #mfirst 4 lines#m of every data file contain titles & axis
  223.    labels
  224.  
  225. 5. For all types of charts, entries in the data file must be
  226.    separated by RETURNS.  
  227.                  * DO NOT SEPARATE ENTRIES WITH COMMAS, ETC. !!!
  228. @
  229. first 4 lines
  230.                 DATA FILE FORMATS
  231.                   FIRST 4 LINES
  232.  
  233. The first 4 lines of every data file regardless of type
  234. will always contain the same type of information:
  235.  
  236. LINE 1 : A TITLE for the graph/diagram
  237.  
  238. LINE 2 : A SUBTITLE for the graph/diagram
  239.  
  240. LINE 3 : The X-axis (horizontal axis) label
  241.  
  242. LINE 4 : The Y-axis (vertical axis) label
  243. @
  244. format3
  245.       RUN, MR, XMR, HISTOGRAM, POLYGON, CDF
  246.                 Data File Format
  247.               
  248. 1. The #mfirst 4 lines#m contain titles & axis labels
  249.  
  250. 2. All entries consist of a numeric value separated by spaces
  251.    followed by an optional string of characters and a carriage
  252.    RETURN.  Only one numerical entry per line is allowed.
  253.  
  254. 3. The length of a RUN, MR, or XMR control chart will be
  255.    the number of entries.
  256.    
  257. 4. SPC EXpert limits the number of entries to 16000 or less.
  258.    
  259. 5. Sample data files are located on your SPCEX System Disk in
  260.    the following files:
  261.    
  262.       "#trun.dmo#t" 
  263.            #u<RUN graphic>;RUN run.dmo default.cfg#u
  264.            #u<MR graphic>;MR run.dmo default.cfg#u
  265.            #u<XMR graphic>;XMR run.dmo default.cfg#u
  266.            #u<HISTOGRAM graphic>;HISTOGRAM run.dmo default.cfg#u
  267.            #u<POLYGON graphic>;POLYGON run.dmo default.cfg#u
  268.            #u<CDF graphic>;CDF run.dmo default.cfg#u
  269. @
  270. format6
  271.               XBAR, R, S, XBAR_R, XBAR_S
  272.                   Data File Formats
  273.  
  274. 1. The #mfirst 4 lines#m contain titles & axis labels
  275.  
  276. 2. The fifth line is an INTEGER between 2 and 200 inclusive.
  277.    This number represents the logical group size or sample size.
  278.  
  279. 3. The remaining entries (REAL or INTEGER) represent the actual
  280.    process measurements.
  281.    
  282. 4. The remaining lines may be coded one of two ways.
  283.  
  284.    (a) If the logical group size is small enough, all entries
  285.        for each group may be placed on a single line separated by spaces.
  286.        For example, the data file below depicts measurements of each of
  287.        five items for each sample number.
  288.  
  289.                     Pitch Diameter
  290.                     Units of .0001 inch in excess of .4000 inch
  291.                     Sample Number
  292.                     Measurement
  293.                     5
  294.                     36 35 34 33 32
  295.                     31 31 34 32 30
  296.                     30 30 32 30 32
  297.                     32 33 33 32 35
  298.  
  299.     (b) The second way to create the data file is to place each measurement
  300.         on a single line.  The data file below will produce the exact same
  301.         results as the one above.  It is particularly useful when the sample
  302.         size is too large to it all sample measurements on a single line.
  303.  
  304.                     Pitch Diameter
  305.                     Units of .0001 inch in excess of .4000 inch
  306.                     Sample Number
  307.                     Measurement
  308.                     5
  309.                     36
  310.                     35
  311.                     34
  312.                     33
  313.                     32
  314.                     31
  315.                     31
  316.                     34
  317.                     32
  318.                     30
  319.                     30
  320.                     30
  321.                     32
  322.                     30
  323.                     32
  324.                     32
  325.                     33
  326.                     33
  327.                     32
  328.                     35
  329.  
  330. 4. The length of the chart(s) will be the number of process
  331.    measurements divided by the logical group size.  For example,
  332.    if we have a group size of 3 and 69 process measurements, then
  333.    the length of the XBAR and R Charts will be 23.
  334.    
  335. 5. Sample XBAR-R data files are located on your SPCEX System Disk 
  336.    in files:
  337.    
  338.    "#tr.dmo#t"
  339.          #u<XBAR graphic>;XBAR r.dmo default.cfg#u
  340.          #u<R graphic>;R r.dmo default.cfg#u
  341.          #u<S graphic>;S r.dmo default.cfg#u
  342.          #u<XBAR_R graphic>;XBAR_R r.dmo default.cfg#u
  343.          #u<XBAR_S graphic>;XBAR_S r.dmo default.cfg#u
  344.    
  345.    "#ts.dmo#t"
  346.          #u<XBAR graphic>;XBAR s.dmo default.cfg#u
  347.          #u<R graphic>;R s.dmo default.cfg#u
  348.          #u<S graphic>;S s.dmo default.cfg#u
  349.          #u<XBAR_R graphic>;XBAR_R s.dmo default.cfg#u
  350.          #u<XBAR_S graphic>;XBAR_S s.dmo default.cfg#u
  351. @
  352. format9
  353.                        PN CHART
  354.                     DATA FILE FORMAT
  355.  
  356. 1. The #mfirst 4 lines#m contain titles & axis labels
  357.  
  358. 2. All numeric entries in a PN Chart data file must be INTEGERS.
  359.  
  360. 3. The fifth line contains an integer which represents the
  361.    fixed sample size.
  362.  
  363. 4. The remaining numeric entries represent the number of defectives
  364.    (rejects/failures) out of a fixed number of samples.  The length
  365.    of the PN chart will be one less than the number of entries in
  366.    the data file.  A sample PN data file is shown below:
  367.  
  368.                     PN Control Chart
  369.                     Lot Size = 200
  370.                     Production Order Number
  371.                     Number of Rejects
  372.                     200
  373.                     23
  374.                     15
  375.                     17
  376.                     15
  377.                     41
  378.                     0
  379.                     25
  380.                     31
  381.                     29
  382.                     0
  383.                     8
  384.                     16
  385.  
  386.  
  387.    Only one entry per line is allowed.
  388.    
  389. 5. A sample PN data file is located in the file
  390.  
  391.    "#tpn.dmo#t"
  392.       #u<PN graphic>;PN pn.dmo default.cfg#u.
  393. @
  394. format11
  395.                        P CHART
  396.                    DATA FILE FORMAT
  397.  
  398. 1. The #mfirst 4 lines#m contain titles & axis labels
  399.  
  400. 2. All remaining entries in a P Chart must be PAIRS of INTEGERS!
  401.    Only one pair per line is allowed.  Each pair may be followed
  402.    by an optional string of characters.
  403.    
  404. 3. The first integer in each pair represents the sample size.
  405.  
  406. 4. The second integer represents the number of defectives or
  407.    rejects.
  408.  
  409. 5. The length of the P Chart will be the number of pairs of
  410.    entries.
  411.  
  412.  
  413.   A sample P data file is shown below:
  414.  
  415.                     P Chart
  416.                     Paragraph 5.6 Data
  417.                     Day
  418.                     Percent Rejected
  419.                     28 4
  420.                     27 9
  421.                     28 3
  422.                     16 2
  423.                     26 1
  424.                     24 1
  425.                     25 5
  426.                     20 5
  427.                     25 14
  428.                     14 1
  429.  
  430. 6. A sample P data file is located in the file
  431.  
  432.    "#tp.dmo#t"
  433.       #u<P graphic>;P p.dmo default.cfg#u.
  434. @
  435. format13
  436.                        C CHART
  437.                   DATA FILE FORMAT
  438.  
  439.  
  440. 1. The #mfirst 4 lines#m contain titles & axis labels
  441.  
  442. 2. All entries in a C Chart data file must be INTEGERS.
  443.  
  444. 3. Each entry represents the number of defects (errors) in a
  445.    sample of fixed size/weight/length/etc.  Only one entry per
  446.    line followed by an optional string of characters is allowed
  447.    per line.
  448.    
  449. 4. The length of the C chart will be the number of entries
  450.    in the data file.
  451.  
  452.   A sample C data file is shown below:
  453.  
  454.                     C Chart
  455.                     Paragraph 5.7 Data
  456.                     Sample number
  457.                     Number of Alignment Errors
  458.                     7
  459.                     6
  460.                     6
  461.                     7
  462.                     4
  463.                     7
  464.                     8
  465.                     12
  466.                     9
  467.                     9
  468.    
  469. 5. A sample C data file is located in the file
  470.  
  471.   "#tc.dmo#t"
  472.      #u<C graphic>;C c.dmo default.cfg#u.
  473. @
  474. format15
  475.                       U Chart
  476.                   DATA FILE FORMAT
  477.  
  478. 1. The #mfirst 4 lines#m contain titles & axis labels
  479.  
  480. 2. All entries in a U Chart must be PAIRS of entries.  Only one
  481.    pair per line followed by an optional string of characters
  482.    is allowed.
  483.  
  484. 3. The first entry in each pair can be either INTEGER or REAL
  485.    and represents the sample size/length/weight/etc.
  486.    
  487. 4. The second entry must be an INTEGER and represents the number
  488.    of defects/errors/etc. in the sample.
  489.    
  490. 5. The length of the U Chart will be the number of pairs of
  491.    entries.
  492.  
  493.   A sample U data file is shown below:
  494.  
  495.  
  496.                     U Chart
  497.                     # Typos in Daily Calendar
  498.                     Day
  499.                     Typos per Word
  500.                     150 2
  501.                     100 1
  502.                     120 0
  503.                     140 3
  504.                     200 6
  505.                     120 1
  506.  
  507.  
  508. 6. A sample U data file is located in the file
  509.  
  510.  "#tu.dmo#t"
  511.     #u<U graphic>;U u.dmo default.cfg#u.
  512. @
  513. format17
  514.                  BAR, PARETO, PIE, TABLE
  515.                     DATA FILE FORMAT
  516.  
  517. 1. The #mfirst 4 lines#m contain titles & axis labels
  518.    
  519. 2. The numeric data for a BAR, PARETO, ... Graphs MUST BEGIN
  520.    ON THE FIFTH LINE OF THE DATA FILE.
  521.    
  522. 3. The numeric data consists of PAIRS (maximum 100) of entries.
  523.  
  524. 4. The first entry can be any NON-NEGATIVE number.
  525.  
  526. 5. The second entry can be anything - this will be the category.
  527.                                  #mSample File;format18#m
  528.  
  529. 6. A sample BAR graph data file is located on your SPCEX System
  530.    Disk in the file "#tbar.dmo#t".  This will produce the
  531.    following graphics:
  532.    
  533.        #u<BAR>;BAR bar.dmo default.cfg#u
  534.        #u<PARETO>;PARETO bar.dmo default.cfg#u
  535.        #u<PIE>;PIE bar.dmo default.cfg#u
  536.        #u<TABLE>;TABLE bar.dmo default.cfg#u
  537. @
  538. format18
  539.  SAMPLE BAR GRAPH
  540.     DATA FILE
  541.  
  542. Any Title You Want
  543. Any Subtitle you want
  544. X AXIS LABEL
  545. Y AXIS LABEL
  546. 25 Type A
  547. 15 Type B
  548. 2 Type C
  549. 55 Type D
  550. @
  551. format26
  552.                        SCATTER DIAGRAM
  553.                        DATA FILE FORMAT
  554.  
  555. 1. The #mfirst 4 lines#m contain titles & axis labels
  556.    
  557. 2. The numeric data for a SCATTER Diagram MUST BEGIN ON THE FIFTH
  558.    LINE OF THE DATA FILE.
  559.    
  560. 3. The numeric data consists of PAIRS of entries.  Both entries in
  561.    each pair can be any number, INTEGER or REAL.  Only one pair
  562.    followed by an optional string of characters is allowed per line.
  563.    
  564. 4. The first number in each pair represents the x-coordinate for that
  565.    pair, and the second represents the y-coordinate.
  566.  
  567.                                    #mSample File;format27#m
  568.  
  569. 5. A sample Scatter diagram data files are located in files
  570.    
  571.         "#tscat.dmo#t"
  572.             #u<graphic>;SCATTER scat.dmo default.cfg#u
  573.  
  574. @
  575. format27
  576. SAMPLE SCATTER DIAGRAM
  577.      DATA FILE
  578.  
  579.    Height vs Weight
  580.    A Hypothetical Sample
  581.    Weight (lbs)
  582.    Height (inches)
  583.    160 70
  584.    180 61
  585.    220 75
  586.    105 61
  587.    155 69
  588. @
  589. format28
  590.                   MULTIPLE Data File Format.
  591.  
  592. 1. SPC EXpert software allows the user to design custom charts by putting
  593.    up to 6 separate graphs in a single multiple graph.  The graphs are
  594.    automatically sized and placed unless otherwise specified.
  595.    
  596. 2. The first two lines for these files contain the multiple chart title
  597.    and subtitle.  The length of each line may be anywhere from 0 to 70
  598.    characters followed by a carriage return.
  599.    
  600. 3. Multiple data files do not have X-axis and Y-axis labels.
  601.  
  602. 4. Beginning on the third line, the multiple file consists of filename
  603.    and chart-type pairs.  A multiple file may contain up to 6 pairs.
  604.    A sample is shown below:
  605.  
  606.                     Multiple Graph
  607.                     Paragraph 5.10 Sample Output
  608.                     CAR.DAT  BAR
  609.                     CAR.DAT PARETO
  610.                     CAR.DAT PIE
  611.                     CAR.DAT TABLE
  612.  
  613. 5. Sample MULTIPLE chart files are located on your SPCEX System Disk:
  614.  
  615.    "#tmulti3.dmo#t"
  616.         #u<MULTIPLE graphic WITH titles>;MULTIPLE multi3.dmo default.cfg#u
  617.         #u<MULTIPLE graphic WITHOUT titles>;MULTIPLE multi3.dmo notitles.cfg#u
  618.  
  619.   "#tmulti2.dmo#t"
  620.         #u<MULTIPLE graphic WITH titles>;MULTIPLE multi2.dmo default.cfg#u
  621.         #u<MULTIPLE graphic WITHOUT titles>;MULTIPLE multi2.dmo notitles.cfg#u
  622.  
  623.   "#tmulti1.dmo#t"
  624.         #u<MULTIPLE graphic WITH titles>;MULTIPLE multi1.dmo default.cfg#u
  625.         #u<MULTIPLE graphic WITHOUT titles>;MULTIPLE multi1.dmo notitles.cfg#u        
  626. @
  627. system1
  628.                              SPC EXpert
  629.                  STATISTICAL PROCESS CONTROL SOFTWARE
  630.             
  631. SPC EXpert is a software tool which automates the statistical and
  632. graphical techniques used in Statistical Process Control (SPC),
  633. Total Quality Management (TQM), and many other techniques designed
  634. for continuous process improvement.  SPC EXpert,
  635.  
  636.  
  637.     1. CONSTRUCTS, ANALYZES, and INTERPRETS 8 different types
  638.        of control charts - both attribute and variables.
  639.        
  640.     2. CONSTRUCTs BAR graphs, PIE charts, PARETO diagrams,
  641.        HISTOGRAMS, Frequency POLYGONS, and Ogives (CDFs).
  642.        
  643.     3. SPC EXpert CONSTRUCTS and ANALYZES scatter diagrams.
  644.  
  645.  
  646. SPC EXpert supports multiple printers; exports to graphics files
  647. which can be imported into commercial graphics and desktop publishing
  648. software such as Harvard Graphics, WordPerfect, MicroSoft PowerPoint,
  649. and MicroSoft Word;  produces regression and process capability 
  650. statistics; automatically analyzes control charts for out-of-control
  651. conditions and provides expert advice on their meaning; provides
  652. and integrated word processor; imports data from ASCII files;
  653.  
  654. Comparable commercial SPC software will cost from $200-$1000 per
  655. single-user copy and from $5000-$20000 for a single-site license.
  656.  
  657. SPC EXpert was developed by
  658.  
  659.     Quality Software Designs, Inc.
  660.     933 East Stroop Road
  661.     Kettering, Ohio 45429
  662.  
  663.  
  664. SPC EXpert Detailed Description
  665.  
  666. 1. PROCESS DATA is collected by the user and placed
  667.    into an ASCII file.  This file can be created by any
  668.    word processing tool.  SPC EXpert includes a
  669.    built-in text editor for this purpose.  The editor can
  670.    be used by selecting #mSPCEX MAIN MENU;TOP_MENU_RESPONSES;screens.hyp#m option J.
  671.  
  672. 2. The user enters the name of the ASCII file which contains
  673.    the process data.  This is done using #mSPCEX MAIN MENU;TOP_MENU_RESPONSES;screens.hyp#m 
  674.    option A.
  675.  
  676. 3. The user then selects the appropriate control chart or
  677.    diagram type. This is done using #mSPCEX MAIN MENU;TOP_MENU_RESPONSES;screens.hyp#m option B.
  678.  
  679. 4. While the user may directly select any chart/diagram type,
  680.    SPCEX provides an automated CONTROL CHART selection service.
  681.    The user will be asked 1 to 3 questions concerning the nature
  682.    of the process data.  From these responses, the appropriate 
  683.    control chart type will be selected.  This is also done using
  684.    #mSPCEX MAIN MENU;TOP_MENU_RESPONSES;screens.hyp#m option B.
  685.  
  686. 5. The user may at this point view the control chart or
  687.    diagram using #mSPCEX MAIN MENU;TOP_MENU_RESPONSES;screens.hyp#m option C.
  688.  
  689. 6. The user may now search a control chart for unusual
  690.    patterns.  This is done using #mSPCEX MAIN MENU;TOP_MENU_RESPONSES;screens.hyp#m option D.
  691.  
  692. AVAILABLE FOR CONTROL CHARTS ONLY.
  693.  
  694.  
  695. 7. After the pattern search, the user may then view the unusual
  696.    patterns highlighted on the control chart.  Each pattern may
  697.    be view separately or all together.  This is done using
  698.    #mSPCEX MAIN MENU;TOP_MENU_RESPONSES;screens.hyp#m option E.
  699.  
  700. AVAILABLE FOR CONTROL CHARTS ONLY.
  701.  
  702. 8. After the pattern search, the user may also obtain expert
  703.    advice concerning the unusual patterns highlighted on the
  704.    control chart.  Information about each pattern may
  705.    be viewed separately or all together.  This is done using
  706.    #mSPCEX MAIN MENU;TOP_MENU_RESPONSES;screens.hyp#m option F.
  707.  
  708. AVAILABLE FOR CONTROL CHARTS ONLY.
  709.  
  710.  
  711. 9.  The user may print out a paper copy of any chart or diagram
  712.     by selection #mSPCEX MAIN MENU;TOP_MENU_RESPONSES;screens.hyp#m option H.  Several different
  713.     printers,print densities, and paper orientations are available.
  714.  
  715. 10. At any time, the user may edit the current data file (or
  716.     any other ASCII text file) by using the SPC integrated 
  717.     editor.  The SPCEX Integrated Text Editor is available by
  718.     selecting #mSPCEX MAIN MENU;TOP_MENU_RESPONSES;screens.hyp#m option J.
  719. @
  720. in_control1
  721.                   IN CONTROL!
  722.  
  723. Your chart is in control!  This means that there are
  724. no unusual patterns within the chart which suggest
  725. the presence of #massignable causes of variation;in_control3#m.
  726.  
  727. Only #mnatural variation;in_control2#m is present.
  728. @
  729. in_control2
  730.                      NATURAL VARIATION
  731.  
  732. The random fluctuation of points within the limits results from
  733. variation built into the process.  Such random variation is
  734. natural, results from common causes within the system (e.g. design,
  735. choice of machine, preventative maintenance, etc.), and can only
  736. be affected by changing the system itself.
  737. @
  738. in_control3
  739.                     UNNATURAL VARIATION
  740.  
  741. However, points which fall outside of the control limits or which
  742. form "unnatural" patterns indicate that some of the variation
  743. within the process may be due to assignable causes.  Assignable
  744. causes of variation (e.g.measurement errors, unplanned events,
  745. freak occurrences, etc.) can be identified and result from
  746. occurrences that are not part of the process.
  747. @
  748. maybe_in_control1
  749.                   IN CONTROL?
  750.  
  751. Your chart MAY BE in control.  This means that the
  752. SHORT or ABORTED SEARCH found no unusual patterns
  753. within the chart which suggest the presence of
  754. #massignable causes of variation;in_control3#m.
  755.  
  756. Only #mnatural variation;in_control2#m is present.
  757.  
  758.  
  759.                     SUGGEST LONG SEARCH
  760.  
  761. The SHORT or ABORTED SEARCH could find no unusual patterns
  762. within the control chart.  To ensure that there are absolutely
  763. no unnatural patterns, use a LONG SEARCH of the control chart.
  764. @
  765. charts0
  766.    CONTROL CHARTS OVERVIEW
  767.  
  768. TABLE OF CONTENTS
  769.  
  770. #mThe Need for Control Charts;charts1#m
  771. #mInterpretation of Control Charts;charts3#m
  772. #mControl Limits;charts5#m
  773. #mTypes of Control Charts;charts6#m
  774. #mChart Type Selection Summary Table;charts11#m
  775. #mRUN Charts;charts12#m
  776. #mMoving Range (XMR) Charts;charts14#m
  777. #mXBAR-R Charts;charts13#m
  778. #mXBAR-S Charts;charts16#m
  779. #mP & PN Charts;charts18#m
  780. #mC & U Charts;charts21#m
  781. charts1
  782.                  THE NEED FOR CONTROL CHARTS
  783.  
  784. Histograms and check sheets consolidate process data to show the
  785. overall picture, while Pareto diagrams are used to indicate problem
  786. areas.  These methods group the data for a specified period and
  787. express them in static form.  However, in our processes we also
  788. want to know more about the nature of the changes that take place
  789. over a specified period of time, that is, the dynamic form.
  790.  
  791. This means that we not only have to see what changes in data occur
  792. over time; we must also study the impact of the various factors in
  793. the process that change over time.  Thus, if the materials, the
  794. workers, or the working methods or equipment were to change during
  795. this time, we would have to note the effect of such changes on our
  796. process. 
  797.  
  798. One way of following these changes is by using control charts.
  799. @
  800. charts3
  801.                 INTERPRETATION OF CONTROL CHARTS
  802.  
  803. Now the problem is to find out whether the points on the graph are
  804. abnormal or not.  Such a determination cannot be made unless
  805. standards of evaluation are set.  Without such standards, one is
  806. liable to make an arbitrary judgment or one favorable to oneself
  807. and the graph will not be meaningful.  When irrational evaluations
  808. are made, necessary action may be missed or unsuitable action may
  809. be taken in haste, thus causing confusion.  This will result in
  810. inappropriate conclusions being drawn, thus lowering quality and
  811. efficiency.
  812.  
  813.                   STANDARDS FOR EVALUATION
  814.  
  815. Limit lines can be drawn on graphs to indicate standards for
  816. evaluation.  These lines will indicate the dispersion of the data
  817. on a statistical basis and indicate if an abnormal situation occurs
  818. in your process.
  819. @
  820. charts5
  821.                       CONTROL LIMITS
  822.  
  823. A graph or a chart with limit lines is called a CONTROL CHART, and
  824. the lines are called control lines.  There are three kinds of
  825. control lines :
  826.  
  827.  
  828.      (1) Upper Control Limit (UCL)
  829.  
  830.      (2) Central Line (or Average)
  831.  
  832.      (3) Lower Control Limit (LCL)
  833. @
  834. charts6
  835.                        TYPES OF CHARTS
  836.  
  837. A control chart's form varies widely according to the kind of data
  838. it contains.  Certain data are based on measurements, such as the
  839. measurement of length of a product (in mm) or the measurement of
  840. the time required to sort a batch of mail (in minutes).  These are
  841. known as indiscrete values or continuous data.  Other data are
  842. based upon counting, such as the number of defective articles or
  843. the number of defects in a product.  They are known as discrete
  844. values or enumerated data.  Control charts based upon these two
  845. categories of data will differ.  Click #mX;charts11#m for a summary
  846. table.
  847.  
  848. Three major factors affect the choice of chart type :
  849.  
  850. 1. #mIndiscrete vs Discrete Data;charts8#m
  851. 2. #mConstant vs Variable Sample Size;charts9#m
  852. 3. #mCounting Defectives vs Counting Defects;charts10#m
  853. @
  854. charts8
  855.          Indiscrete vs Discrete Data
  856.  
  857.  
  858. 1. Discrete (Attribute Data)
  859.  
  860.                       Examples include : number of errors
  861.                                          number of rejects
  862.                                          number of reworks
  863.  
  864.  
  865. 2. Indiscrete (Measurement) Data
  866.  
  867.                       Examples include : length
  868.                                          weight
  869.                                          time
  870. @
  871. charts9
  872.             Constant vs Variable Sample Size
  873.  
  874. 1. Constant - Examples include :
  875.  
  876.               (a) # pin holes in a fixed area of sheet metal
  877.               (b) # rejects out of a fixed batch size
  878.  
  879. 2. Variable - Examples include :
  880.  
  881.               (a) # pin holes in pieces of sheet metal differing
  882.                   in area
  883.               (b) # rejects out of batches differing in size
  884.               (c) # typographic errors in letters (of differing
  885.                   length)
  886. @
  887. charts10
  888.       Counting Defectives vs Counting Defects
  889.  
  890. 1. Defectives - This is the number of parts/units/etc that
  891.                 are rejected or un-usable.  Examples include :
  892.  
  893.                     (a) # letters returned for rework.
  894.                     (b) # sheets of metal rejected.
  895.  
  896.  
  897. 2. Defects - This is the number of flaws in a part/unit/etc.
  898.              Example include :
  899.              
  900.                    (a) # typographic errors in a letter.
  901.                    (b) # pin holes in a sheet of metal.
  902. @
  903. charts11
  904.               CHART TYPE SELECTION SUMMARY TABLE
  905.  
  906. Chart-type    Measurement-type   Sample-size   Defects/Defectives
  907. ----------    ----------------   -----------   ----------------
  908. Run           Continuous         1             N/A
  909. XMR           Continuous         1             N/A
  910. XBAR          Continuous         Constant > 1  N/A
  911. R             Continuous         Constant > 1  N/A
  912. XBAR-R        Continuous         Constant > 1  N/A
  913. S             Continuous         Constant > 10 N/A
  914. XBAR-S        Continuous         Constant > 10 N/A
  915. PN            Discrete           Constant      Defectives
  916. P             Discrete           Variable      Defectives
  917. C             Discrete           Constant      Defects
  918. U             Discrete           Variable      Defects
  919. @
  920. charts12
  921.                        RUN CHART
  922.  
  923. Run charts are employed to visually represent data.  They are
  924. used to monitor a process to see whether or not the long range
  925. average is changing.
  926.  
  927. Run charts are the simplest tool to construct and use.  Points
  928. are plotted on the graph in the order in which they become
  929. available.   It is common to graph the results of a process
  930. such as machine downtime, yield, scrap, typographical errors or
  931. productivity as they vary over time.
  932.  
  933.  -> Select for an #mExample Run Chart Process Measurement;charts17#m
  934. @
  935. charts13
  936.                         XBAR-R Chart
  937.  
  938. The XBAR-R control chart is one that shows both the mean value,
  939. XBAR, and the range, R of a sample.  This is the most common type
  940. of control chart using indiscrete or continuous values.  The XBAR
  941. portion of the chart mainly shows any changes in the mean value of
  942. the process, while the R portion shows any changes in the
  943. dispersion of the process.  This chart is particularly useful
  944. because it shows changes in mean value and dispersion of the
  945. process at the same time, making it a very effective method for
  946. checking abnormalities in the process.
  947.  
  948.  -> Select for an #mExample XBAR-R Chart Process Measurement;charts17#m
  949. @
  950. charts14
  951.                 MOVING RANGE (XMR) Chart
  952.  
  953. Sometimes collecting enough data to produce a XBAR-R chart is
  954. impossible or at least impractical.  Sometimes the natural subgroup
  955. size should be one (1) like when a measurement represents a lot
  956. or batch.  In this case we need to be able to look at just a single
  957. measurement as a subgroup, hence an individuals chart.  But what
  958. about the fact that the range is based on the variation between
  959. subgroup members?  In this case, we use a range chart made of the 
  960. range of the last two individuals or a moving range chart.
  961.  
  962. The XMR chart does not detect changes in the process as fast as
  963. an XBAR-R chart.  So we should only use them when it is not
  964. practical to use the XBAR-R chart because of limits in data
  965. availability or if the rational subgroup is one (1).
  966.  
  967.  -> Select for an #mExample XMR Chart Process Measurement;charts17#m
  968. @
  969. charts16
  970.                         XBAR-S Chart
  971.  
  972. The XBAR-S chart is identical to the XBAR-R chart except that the
  973. R (range) chart is replaced by an S (standard deviation) chart.
  974. XBAR-S charts should be used when the logical group size is
  975. larger than ten (10).
  976.  
  977.  -> Select for an #mExample XBAR-S Chart Process Measurement;charts17#m
  978. @
  979. charts17
  980.                  SAMPLE PROCESS MEASUREMENTS
  981.                RUN, XMR, XBAR-R, & XBAR-S Chart
  982.  
  983.  
  984. (a) The length of time a document sits in an "in-box"
  985.  
  986. (b) The number of hours required to sort a bundle of mail
  987.  
  988. (c) The diameter of a bore hole in a machining process
  989. @
  990. charts18
  991.                         P and PN CHARTS
  992.  
  993. A P chart is one that shows the fraction defective (p), whereas a
  994. PN chart shows the number of defectives (pn).  Basically, they are
  995. the same except that a PN chart is used when the size of the
  996. subgroup (sample size) (n) is constant and a P chart is used when
  997. it is not constant.  Obviously, when the size of the subgroup (n)
  998. varies, the defective measurement can only be meaningful in
  999. fractional or proportional terms.  The P and PN charts are not used
  1000. together as are the XBAR and R charts.  This is because P and PN
  1001. charts show the characteristics of both mean and dispersion of the
  1002. process.
  1003.  
  1004.  -> Select for an #mExample PN Chart Process Measurement;charts19#m
  1005.  
  1006.  -> Select for an #mExample P Chart Process Measurement;charts20#m
  1007. @
  1008. charts19
  1009.                   SAMPLE PROCESS MEASUREMENTS
  1010.                         PN Chart
  1011.  
  1012.  
  1013. (a) The number of bytes of a 1 Megabyte file incorrectly
  1014.     transferred via modem.
  1015.  
  1016. (b) The number of broken eggs in a carton of eggs.
  1017. @
  1018. charts20
  1019.                  SAMPLE PROCESS MEASUREMENTS
  1020.                          P Chart
  1021.  
  1022.  
  1023. (a) The number of letters returned for rework each day
  1024.     (This assumes that the number of letters worked each
  1025.      day may be different.)
  1026.  
  1027. (b) The number of customers who leave each day before getting
  1028.     service due to long delays.
  1029.  
  1030. (c) The number of documents which spent more than a total of 4
  1031.     hours that day sitting in in-baskets.
  1032.  
  1033. (d) The number of defective components in batches of varying size.
  1034. @
  1035. charts21
  1036.                         C and U CHARTS
  1037.  
  1038. A U chart is used in dealing with the number of defectives when the
  1039. material being inspected is not constant in area and length such
  1040. as the unevenness of woven materials or pin holes in enamel wire. 
  1041. A C control chart is used in dealing with the number of defects
  1042. which appear in fixed unit samples, such as the number of
  1043. imperfectly soldered connections in radios, etc.
  1044.  
  1045.  -> Select for an #mExample C Chart Process Measurement;charts22#m
  1046.  
  1047.  -> Select for an #mExample U Chart Process Measurement;charts23#m
  1048. @
  1049. charts22
  1050.                   SAMPLE PROCESS MEASUREMENTS
  1051.                          C Chart
  1052.  
  1053.  
  1054. (a) The number of incorrectly soldered connections on a particular
  1055.     circuit board.
  1056.  
  1057. (b) The number of surface flaws in identical pieces of sheet metal.
  1058. @
  1059. charts23
  1060.                    SAMPLE PROCESS MEASUREMENTS
  1061.                           U Chart
  1062.  
  1063.  
  1064. (a) The number of misspellings in documents of varying length.
  1065.  
  1066. (b) The number of surface flaws in pieces of sheet metal of varying
  1067.     area.
  1068. @
  1069. graph0
  1070.    GRAPHS/DIAGRAMS OVERVIEW
  1071.  
  1072. Select/Click-On An Item of Interest
  1073.  
  1074.  
  1075.      #mBar Graphs;graph1#m
  1076.      #mPareto Diagrams;graph3#m
  1077.      #mPie Charts;graph5#m
  1078.      #mScatter Diagrams;graph6#m
  1079.      #mHistograms;graph9#m
  1080.      #mFrequency Polygons;graph10#m
  1081.      #mOgives (CDFs);graph11#m
  1082. @
  1083. graph1
  1084.                        Bar Graphs
  1085.  
  1086.  
  1087. Bar Graphs are a very simple way of illustrating the nature of your
  1088. process data.  A bar graph simply illustrates the relative
  1089. frequencies or magnitude of data which can be broken down into
  1090. distinct categories.
  1091.  
  1092.      #m * ;graph2#m Sample Bar Graph Data
  1093. @
  1094. graph2
  1095.    SAMPLE BAR GRAPH DATA
  1096.  
  1097.  
  1098.  
  1099.  Frequency       Category
  1100. -----------    --------------
  1101.     20            Type A
  1102.     15            Type B
  1103.     55            Type C
  1104.     22            Type D
  1105.      5            Type E
  1106.      7            Type F
  1107. @
  1108. graph3
  1109.                    The Need For Pareto Charts
  1110.  
  1111. There are many aspects of any process that could be improved :
  1112. defectives, time allocation, cost savings, rework, etc.  In fact,
  1113. each problem consists of so many smaller problems that it is
  1114. difficult to know just where to begin solving them.  In order to
  1115. be efficient, a definite basis is needed for any action.
  1116.  
  1117. A Pareto chart is the tool to use when you need to display the
  1118. relative importance of all of the problems or conditions in order
  1119. to :  choose the starting point for problem solving, monitor
  1120. success, or identify the basic cause of a problem.
  1121.  
  1122. #mWHAT IS A PARETO CHART?;graph4#m
  1123. @
  1124. graph4
  1125.                 WHAT IS A PARETO CHART?
  1126.  
  1127. A Pareto Chart is a special form of a vertical bar graph which
  1128. helps us determine which problems to solve in what order.  Doing
  1129. a Pareto Chart based upon either Check Sheets or other forms of
  1130. data collection helps us direct our attention and efforts to the
  1131. truly important problems.  We will generally gain more by working
  1132. on the tallest bar than tackling the smaller bars. More information
  1133. concerning the use of Pareto Charts is available through SPC's
  1134. MORE INFORMATION MENU.
  1135. @
  1136. graph5
  1137.                        Pie Charts
  1138.  
  1139. Pie Charts are simply graphs in which the entire circle represents
  1140. 100% (not 360 degrees) of the data to be displayed.  The circle
  1141. (pie) is divided into percentage slices that clearly show the
  1142. largest shares of data.  This is useful in the same way as a Pareto
  1143. Chart.  The Pie Chart is sometimes even more useful since it is
  1144. widely used to display data on T.V. or in the newspapers.  More
  1145. information concerning the use of Pareto Charts is available
  1146. through SPC's MORE INFORMATION MENU.
  1147. @
  1148. graph6
  1149.                    Scatter Diagrams
  1150.  
  1151. A Scatter Diagram is the tool to use when you need to display what
  1152. happens to one variable when another variable changes in order to
  1153. test a theory that the two variables are related.
  1154.  
  1155. A Scatter Diagram is used to study the possible relationship
  1156. between one variable and another.  The Scatter Diagram is used to
  1157. test for possible cause and effect relationships.  It cannot prove
  1158. that one variable causes the other, but it does make it clear
  1159. whether a relationship exists and the strength of that
  1160. relationship.  Select for #mSAMPLE SCATTER DIAGRAM DATA;graph8#m.
  1161.  
  1162. A Scatter Diagram is set up whereby the horizontal axis (x-axis)
  1163. represents the measurement values of one variable, and the vertical
  1164. axis (y-axis) represents the measurement values of the second
  1165. variable.  More information concerning the use of Scatter Diagrams
  1166. is available through SPC's MORE INFORMATION MENU.
  1167. @
  1168. graph8
  1169.     SAMPLE SCATTER DIAGRAM DATA
  1170.  
  1171.  
  1172. Person         Weight        Height
  1173.  
  1174.   1               160            70
  1175.   2               180            61
  1176.   3               220            75
  1177.   .                .              .
  1178.   .                .              .
  1179.  50               105            61 
  1180.  
  1181. @
  1182. graph9
  1183.                        Histograms
  1184.  
  1185. As we have already seen with the Pareto Chart, it is very helpful
  1186. to display in bar graph form the frequency with which certain
  1187. events occur (frequency distribution).  The Pareto Chart, however,
  1188. only deals with characteristics of a product or service, e.g., type
  1189. of defect, problem, safety hazards, etc. (attribute data). A
  1190. Histogram takes measurement data, e.g., temperature, dimensions,
  1191. etc., and displays it's distribution.  This is critical since we
  1192. know that all repeated events will produce results that vary over
  1193. time.  A Histogram reveals the amount of variation that any process
  1194. has within it.
  1195. @
  1196. graph10
  1197.                     Frequency Polygons
  1198.  
  1199. Another kind of graphical display of a frequency distribution
  1200. (Histogram) is the Frequency Polygon.  Here the cell (data range)
  1201. frequencies are plotted at the midpoint of each cell and the
  1202. midpoints are joined by straight lines.
  1203. @
  1204. graph11
  1205.           Ogives (Cumulative Distribution Function)
  1206.  
  1207. If the same technique in the Frequency Polygon is applied to the
  1208. cumulative distribution function, we obtain what is called an
  1209. Ogive (rhymes with alive) or CDF.  The only difference is that in
  1210. constructing the Ogive (CDF), the cell boundary is used as the plot
  1211. point rather than the middle of the cell.
  1212. @
  1213. hypertext help
  1214.             HYPERTEXT INFORMATION SYSTEM
  1215.  
  1216. 1. You are currently using the hypertext information system.
  1217.  
  1218. 2. Text which is highlighted in light green or light blue are
  1219.    referred to as hot links.
  1220.    
  1221. 3. This is a #mSample Text Hot Link#m  Click on this with the
  1222.    left mouse button or by pressing <ENTER>.
  1223.  
  1224. 4. "#tbar.dmo#t" is a sample Text File Hot Link.  Click
  1225.    on it with the left mouse button or move the highlight
  1226.    over it using TAB or DOWN-ARROW and then press
  1227.    <ENTER>.
  1228.    
  1229. 5. HYPERTEXT window help is available by pressing <F1> 
  1230.  
  1231. 6. The entire contents of any hypertext window may be saved to
  1232.    an ASCII (DOS TEXT) file by pressing <F3>.  This is the best
  1233.    way to print the contents of a hypertext window by importing
  1234.    the resulting ASCII file into a standard word processor. 
  1235. @
  1236. Sample Text Hot Link
  1237.  
  1238. After you click on a Text Hot Link, additional text will come
  1239. up in a window.  #mOther hot links#m may also be in this window.
  1240.  
  1241. To go back to the previous window, press ESC or click the
  1242. right mouse button.
  1243. @
  1244. Other hot links
  1245. Again, a text box appears.  This
  1246. may repeat for several levels.
  1247.  
  1248. To go back to the previous window,
  1249. press ESC or click the right mouse
  1250. button.
  1251. @
  1252.