TVA's Widows Creek Unit 8 (500 MW nominal)
* this is a QUEST configuration file
5 one HP, one IP, and one LP turbine, with reheat
* Tb Pb Fb Tr BP
1050. 2415. 3820000. 1000. 1.50
*HP turbine stages
2
*HP turbine type
2
*HP turbine generator connection
1
*HP turbine flow factor(s)
254.8
165.3
*HPT throttle leak to reheater exit/IPT inlet
0.
*HPT throttle leak to SSR
-2600.
*HPT HP seal leak to SSR
0.
*HPT HP seal leak to open feedwater heater
0.
*HPT HP seal leak to HPT exit/reheater inlet
0.
*HPT LP seal leak to open feedwater heater
-1500.
*HPT LP seal leak to SSR
-6800.
*IP turbine stages
1
*IP turbine type
5
*IP turbine generator connection
1
*IP turbine flow factor(s)
20.28
*IPT LP seal leak to open feedwater heater
800.
*IPT LP seal leak to SSR
100.
*cross-over pressure drop factor
5.00
*LP turbine stages
3
*LP turbine type
5
*LP turbine generator connection
2
*LP turbine flow factor(s)
6.827
2.298
*LPT LP seal leak to SSR
800.
*last stage annulus area in square feet (single flow)
41.10
*number of annuli
8
*FP turbine stages
4
*FP turbine type
9
*FP turbine supply (1-7: HPT, 8-14:IPT, 15-21:LPT, 91:B, 93:R)
2
*FP turbine flow factor(s)
509.43
283.02
208.90
148.25
*generator 1 type
3 3600-rpm conductor-cooled
*generator 1 rated KVA
277778.
*generator 2 type
3 3600-rpm conductor-cooled
*generator 2 rated KVA
277778.
*makeup flow
0.
*makeup injection
H=hotwell
*boiler pressure drop and efficiency
15.0 89.85
*reheater pressure drop and efficiency
10.0 89.85
*number of heat exchangers
9
*heat exchanger type, TTD, DCA, shell pressure drop
* type 1: no drain inlet, type 2: drain inlet, type 3: open
*type TTD DCA DP
1 .0 10.0 5.0
2 5.0 10.0 5.1
2 5.0 10.0 5.0
3 .0 .0 5.5
1 5.0 10.0 5.0
2 5.0 .0 5.1
1 5.0 .0 5.1
2 5.0 .0 5.5
YES, last heat exchanger before GSC drains to condenser
*boiler feedpump efficiency
83.0
*SSR flow to GSC
1600.
*SSR flow to condenser
0.
*SSR flow to LP turbine seals
2720.
*service load (+KW or -%)
-2.50