  1. TVA's Widows Creek Units 5-6 (125 MW nominal)
  2. * this is a QUEST configuration file
  3. 5 one HP, one IP, and one LP turbine, with reheat
  4. * Tb    Pb      Fb     Tr    BP
  5. 1000. 1815.   838000. 1000. 2.00
  6. *HP turbine stages
  7.  2
  8. *HP turbine type
  9.  3  high pres., 3600-rpm, noncondensing, 2-row governing stage
  10. *HP turbine generator connection
  11.  1
  12. *HP turbine flow factor(s)
  13.  896.9
  14.  507.2
  15. *HPT throttle leak to reheater exit/IPT inlet
  16.       0.
  17. *HPT throttle leak to SSR
  18.    1280.
  19. *HPT HP seal leak to SSR
  20.   -1550.
  21. *HPT HP seal leak to open feedwater heater
  22.       0.
  23. *HPT HP seal leak to HPT exit/reheater inlet
  24.  -14880.
  25. *HPT LP seal leak to open feedwater heater
  26.   -3350.
  27. *HPT LP seal leak to SSR
  28.   -1860.
  29. *IP turbine stages
  30.  3
  31. *IP turbine type
  32.  4  intermediate pres., 3600-rpm, noncondensing, w/o gov. stage
  33. *IP turbine generator connection
  34.  1
  35. *IP turbine flow factor(s)
  36.  273.4
  37.  131.3
  38.   71.34
  39. *IPT LP seal leak to open feedwater heater
  40.   -3820.
  41. *IPT LP seal leak to SSR
  42.   -1990.
  43. *cross-over pressure drop factor
  44.     .00
  45. *LP turbine stages
  46.  3
  47. *LP turbine type
  48.  5  reheat, 3600-rpm, condensing, w/o governing stage
  49. *LP turbine generator connection
  50.  1
  51. *LP turbine flow factor(s)
  52.   30.65
  53.    9.658
  54. *LPT LP seal leak to SSR
  55.       0.
  56. *last stage annulus area in square feet (single flow)
  57.   32.90
  58. *number of annuli
  59.  3
  60. *FP turbine stages
  61.  0
  62. *generator 1 type
  63. 1 3600-rpm conventionally cooled
  64. *generator 1 rated KVA
  65.   125000.
  66. *makeup flow
  67.  -16740.
  68. *makeup injection
  69. D=deaerator
  70. *boiler pressure drop and efficiency
  71. 15.0  88.5
  72. *reheater pressure drop and efficiency
  73. 10.0  88.5
  74. *heat exchanger type, TTD, DCA, shell pressure drop
  75. * type 1: no drain inlet, type 2: drain inlet, type 3: open
  76. *type  TTD  DCA   DP
  77.    1    .0 10.0  8.0
  78.    2   5.0 13.0  5.0
  79.    2   7.7 10.0  7.8
  80.    3    .0   .0  7.8
  81.    1   5.0 10.0  7.8
  82.    2   5.0   .0  7.9
  83.    1   5.0   .0  7.9
  84. NO, last heat exchanger before GSC does not drain to condenser
  85. *boiler feedpump efficiency
  86.  85.0
  87. *SSR flow to GSC
  88.    1000.
  89. *SSR flow to condenser
  90.       0.
  91. *SSR flow to LP turbine seals
  92.       0.
  93. *service load (+KW or -%)
  94.     -5.00