  1. Gulf Power's Scholz Plant (40 MW nominal)
  2. * this is a QUEST configuration file
  3. 1. one HP turbine only, w/o reheat
  4. * Tb    Pb      Fb     BP
  5.  900.  850.   359000. 2.00
  6. *HP turbine stages
  7.  6
  8. *HP turbine type
  9.  1
  10. *HP turbine generator connection
  11.  1
  12. *HP turbine flow factor(s)
  13.  937.9
  14.  493.0
  15.  193.9
  16.   94.54
  17.   25.09
  18. *HPT throttle leak to SSR
  19.       0.
  20. *HPT HP seal leak to SSR
  21.   -2050.
  22. *HPT HP seal leak to open feedwater heater
  23.   -3970.
  24. *HPT LP seal leak to SSR
  25.    -600.
  26. *last stage annulus area in square feet (single flow)
  27.   32.90
  28. *number of annuli
  29.  1
  30. *FP turbine stages
  31.  0
  32. *generator 1 type
  33.   1
  34. *generator 1 rated KVA
  35.    40000.
  36. *makeup flow
  37.   -5100.
  38. *makeup injection
  39. D=deaerator
  40. *boiler pressure drop and efficiency
  41. 21.3  88.5
  42. *heat exchanger type, TTD, DCA, shell pressure drop
  43. * type 1: no drain inlet, type 2: drain inlet, type 3: open
  44. *type  TTD  DCA   DP
  45.    1   4.5   .0 10.0
  46.    2   4.5   .0 10.0
  47.    3    .0   .0 10.0
  48.    1   4.5   .0 10.0
  49.    2   4.5   .0 10.0
  50. NO, last heat exchanger before GSC does not drain to condenser
  51. *boiler feedpump efficiency
  52.  85.0
  53. *SSR flow to GSC
  54.     600.
  55. *SSR flow to condenser
  56.       0.