  1. TVA's Colbert Unit 5 (500 MW nominal)
  2. * this is a QUEST configuration file
  3. 5 one HP, one IP, and one LP turbine, with reheat
  4. * Tb    Pb      Fb     Tr    BP
  5. 1050. 2415.  3868000. 1000. 1.50
  6. *HP turbine stages
  7.  2
  8. *HP turbine type
  9.  1
  10. *HP turbine generator connection
  11.  1
  12. *HP turbine flow factor(s)
  13.  272.17
  14.  172.40
  15. *HPT throttle leak to reheater exit/IPT inlet
  16.       0.
  17. *HPT throttle leak to SSR
  18.   -4500.
  19. *HPT HP seal leak to SSR
  20.       0.
  21. *HPT HP seal leak to open feedwater heater
  22.       0.
  23. *HPT HP seal leak to HPT exit/reheater inlet
  24.       0.
  25. *HPT LP seal leak to open feedwater heater
  26.  -10300.
  27. *HPT LP seal leak to SSR
  28.   -2825.
  29. *IP turbine stages
  30.  1
  31. *IP turbine type
  32.  5
  33. *IP turbine generator connection
  34.  1
  35. *IP turbine flow factor(s)
  36.   24.76
  37. *IPT LP seal leak to open feedwater heater
  38.       0.
  39. *IPT LP seal leak to SSR
  40.   -6800.
  41. *cross-over pressure drop factor
  42.     .00
  43. *LP turbine stages
  44.  4
  45. *LP turbine type
  46.  5
  47. *LP turbine generator connection
  48.  2
  49. *LP turbine flow factor(s)
  50.   17.41
  51.    7.28
  52.    2.58
  53. *LPT LP seal leak to SSR
  54.    1300.
  55. *last stage annulus area in square feet (single flow)
  56.   32.90
  57. *number of annuli
  58.  8
  59. *FP turbine stages
  60.  4
  61. *FP turbine type
  62.  9
  63. *FP turbine supply (1-7: HPT, 8-14:IPT, 15-21:LPT, 91:B, 93:R)
  64.  2
  65. *FP turbine flow factor(s)
  66.  522.12
  67.  213.88
  68.  150.98
  69.   98.97
  70. *generator 1 type
  71. 3 3600-rpm conductor-cooled
  72. *generator 1 rated KVA
  73.   277777.
  74. *generator 2 type
  75. 3 3600-rpm conductor-cooled
  76. *generator 2 rated KVA
  77.   277777.
  78. *makeup flow
  79.       0.
  80. *makeup injection
  81. H=hotwell
  82. *boiler pressure drop and efficiency
  83. 15.0  89.6
  84. *reheater pressure drop and efficiency
  85. 10.0  89.6
  86. *number of heat exchangers
  87.   9
  88. *heat exchanger type, TTD, DCA, shell pressure drop
  89. * type 1: no drain inlet, type 2: drain inlet, type 3: open
  90. *type  TTD  DCA   DP
  91.    1    .0 10.0  5.0
  92.    2   5.0 10.0  5.0
  93.    2   5.0 10.0  5.0
  94.    3    .0   .0  5.5
  95.    1   5.0 10.0   .0
  96.    2   5.0   .0  5.0
  97.    1   5.0   .0  5.0
  98.    2   5.0 10.0  5.0
  99. YES, last heat exchanger before GSC drains to condenser
  100. *boiler feedpump efficiency
  101.  69.0
  102. *SSR flow to GSC
  103.    2000.
  104. *SSR flow to condenser
  105.       0.
  106. *SSR flow to LP turbine seals
  107.    3500.
  108. *service load (+KW or -%)
  109.     -2.50
  110.