John Sevier Steam Plant, 4 Units, 180 MW nominal each
4 <number of units
4 <number of cooling towers
M <is tower 1 mechanical draft
1 2 3 4 0 0 <unit(s) is(are) connected to tower
M <is tower 2 mechanical draft
1 2 3 4 0 0 <unit(s) is(are) connected to tower
M <is tower 3 mechanical draft
1 2 3 4 0 0 <unit(s) is(are) connected to tower
M <is tower 4 mechanical draft
1 2 3 4 0 0 <unit(s) is(are) connected to tower
191 191 191 191 0 0 <design loads [MW]
200 200 200 200 0 0 <maximum loads [MW]
2.0 2.0 2.0 2.0 .0 .0 <design BP(s) [in.Hg]
5.0 5.0 5.0 5.0 .0 .0 <maximum BP(s) [in.Hg]
7933 7933 7933 7933 0 0 <design condenser heatrate(s)
.85 .85 .85 .85 .00 .00 <design condenser cleanliness
113500 113500 113500 113500 0 0 <design condenser flow(s) [gpm]
72.0 72.0 72.0 72.0 .0 .0 <design condenser inlet temp(s)
113500 113500 113500 113500 0 0 <design tower flow(s) [gpm]
116.95 116.95 116.95 116.95 .0 .0 <design tower inlet temp(s)
101.0 101.0 101.0 101.0 .0 .0 <design tower exit temp(s)
92.0 92.0 92.0 92.0 .0 .0 <design cooling tower dry-bulb
80.0 80.0 80.0 80.0 .0 .0 <design cooling tower wet-bulb