home *** CD-ROM | disk | FTP | other *** search
/ DP Tool Club 24 / CD_ASCQ_24_0995.iso / vrac / invb602b.zip / UPGRADE.TXT < prev    next >
Text File  |  1995-06-13  |  8KB  |  142 lines

  1.                                                                 May 1995
  2.  Upgrading versus Updating
  3.  -------------------------
  4.  The user of anti-virus software are accustomed to update their AV
  5.  software at regular intervals. Updates are necessary if your anti virus
  6.  is a scanner. The spreading of new viruses in the past has been
  7.  relatively slow. It took a year, sometimes even two, for new viruses to
  8.  become common, in a certain geographical area. Now, with the
  9.  availability of the networks, virus spreading takes much less than
  10.  before. The virus exchanges (VX) has also largely contributed to the
  11.  rapid dissemination of viruses. Once a virus is in the news, thousands
  12.  of collection owners are looking to add the hot item to their
  13.  collection, and quite many viruses escaped in the wild this way.
  14.  
  15.  Certain viruses have set records and became common within three to six
  16.  months from their first being reported. Therefore, scanner based
  17.  anti-virus software need updating, at three months intervals at the
  18.  longest. Some products are updated with shorter intervals. It is quite
  19.  common that the producer of a scanner announces a special release when
  20.  a new virus hits the news. Such were the cases of Junkie and KAOS4. In
  21.  most cases the hysteria proved to be overblown.
  22.  
  23.  InVircible has a virus scanner too. Its database contains only the most
  24.  common and widespread viruses, just about a couple of hundreds, which
  25.  are about 5% or less of the total number of viruses. Naturally, it
  26.  takes quite a long time, a year or longer, for a virus to become really
  27.  widespread. Only few viruses make it, and this is why IV's scanner has
  28.  very few viruses added to its database, annually.
  29.  
  30.  NetZ Computing keeps publishing new versions of InVircible on a regular
  31.  basis. Sometimes the new version contains a new virus in its database,
  32.  but in most cases it does not. The real purpose of these apparently
  33.  updates is totally different. Since in most cases they do not contain
  34.  scanner updates, then we will call them what they really are: upgrades.
  35.  
  36.  With the constant flux of users' questions, wishes and suggestions, we
  37.  often improve a certain technique, or fix a bug, or even more likely -
  38.  add a new feature. If you look in the HISTORY.TXT file, you will notice
  39.  that there isn't a single version that announced a new virus was added
  40.  to IV's database. The differences between versions, or revisions, is
  41.  due to new features, or changes introduced in basic techniques.
  42.  
  43.  Do you need to upgrade?
  44.  -----------------------
  45.  If the current version of InVircible works properly on your machine,
  46.  then it's unlikely that you need to upgrade. Unless you want to,
  47.  because of a new features included in the newer version.
  48.  
  49.  A text file named WHATSNEW.xxx is provided with each upgrade. In the
  50.  file you'll find a list and description of the improved and of the new
  51.  features. Before upgrading your current version, read the document to
  52.  decide if you need the upgrade.
  53.  
  54.  There is no need to upgrade InVircible more frequently than once to
  55.  twice a year, at the most. In the five years since its first version,
  56.  InVircible proved to be efficient against the viruses that appeared
  57.  since then, with or without the upgrades.
  58.  
  59.  Network administrators are advised to upload the upgraded version to
  60.  the server, to the directory from which IVlogin is run (see appendix A
  61.  in the manual). This will automatically upgrade the IV version on the
  62.  workstation hard disks, when the user logs into the network.
  63.  
  64.  How to upgrade a licensed user.
  65.  -------------------------------
  66.  The purchase of a license for the utilization of InVircible is for
  67.  life, for the specific version that you purchased only, and provides
  68.  you the possibility to upgrade without additional charges, for a period
  69.  of one year, from the date of the production of the software. The
  70.  installation of the IV license to your hard disk earmarks the HARD
  71.  DISK, not the software, as an IV licensee. The InVircible software
  72.  recognizes the IV earmark.
  73.  
  74.  To upgrade from a lower version, download the newer InVircible version
  75.  from the BBS or network service of your choice. Open the ZIP file into
  76.  a temporary directory, change directory to the one containing the new
  77.  version and run the IVB.EXE program. Watch if the "Licensed" label
  78.  appears at the upper left corner of the screen. If yes, then your
  79.  license is still valid for this upgrade and you can then proceed with
  80.  INSTALL/FAST. It will overwrite the older version with the new one and
  81.  it will inherit the license of the former version.
  82.  
  83.  To upgrade a licensed floppy, format the diskette (deleting all files
  84.  won't suffice, there is a hidden file on these floppies, this is why it
  85.  needs formatting) and copy the new version files to it. When done,
  86.  issue the command IVB /A A: (or B:) to install the IV Armor on the
  87.  floppy.
  88.  
  89.  In case the newer version indicates "Sentry" instead of "Licensed" when
  90.  running the newer software, then your license term for upgrades
  91.  expired. You can then choose to purchase a new license for another
  92.  term, or stay with your current version, for as long as you wish.
  93.  
  94.  Once you changed the license from a 6.01x version to 6.02, on your hard
  95.  disk, then the lower versions will not recognize the hard disk as
  96.  licensed anymore. Yet the distribution floppy is valid for both 6.01x
  97.  and 6.02 versions.
  98.  
  99.  For licensed users working in OS/2 and Windows 95.
  100.  --------------------------------------------------
  101.  To upgrade your license from version 6.01x to 6.02, to reflect both in
  102.  DOS and in the 32 bit OS DOS shell, you will need to run InVircible
  103.  ONCE in a real DOS environment.
  104.  
  105.  The simplest is to boot from a DOS floppy and run a copy of IVB or
  106.  IVSCAN (from version 6.02A).
  107.  
  108.  Updating the 6.02 Rescue Diskette.
  109.  ----------------------------------
  110.  IVB 6.02A went through functional enhancements. Therefore, the IVB
  111.  signatures of the newer version are no more compatible with those of
  112.  the lower versions.
  113.  
  114.  The default name of the signatures' file has been changed in version
  115.  6.02A to "IVB .NTZ". Note the "space" after IVB, it's actually the
  116.  ascii character 255 (hold the Alt key and type 255 on the right hand
  117.  numeric keypad, then release the Alt key). The purpose of the change is
  118.  to keep the older signatures without overwriting them through the
  119.  process of upgrading. After you checked that all files comply with the
  120.  former signatures, you may erase the old signatures with the older
  121.  IVMENU, selecting the "Remove" [signatures] option from the main menu.
  122.  The newer version will automatically establish its database files
  123.  through the INSTALL sequence or the daily check.
  124.  
  125.  For the same reason, it's also important that you renew your rescue
  126.  diskette AFTER having successfully upgraded to 6.02A. The same applies
  127.  to IV Sentry users.
  128.  
  129.  Next version Preview package.
  130.  -----------------------------
  131.  A preview version of InVircible is now available on the author's ftp
  132.  (ftp.datasrv.co.il in /pub/usr/netz/preview).
  133.  
  134.  The preview package consists of the current version, with the recent
  135.  fixes and improvements that were made in InVircible. The preview
  136.  directory contains a text file named WHATSNEW.PRE, with the description
  137.  of the upgrades contained in the package.
  138.  
  139.  The purpose of the preview version is to let as many as possible users
  140.  to test the fixes and improvements in IV and to fix problems at an
  141.  early stage, before the release to the public.
  142.