  1.  
  2.  
  3.         
  4.             AT User Diagnostics Revision History
  5.  
  6.  
  7.     Written: First pass, March 1989 by Western Digital Corp.
  8.  
  9.     Purpose: Allow quick, easy and thorough AT hard disk controller
  10.          and hard disk diagnostics.
  11.  
  12.     Compatability : All Western Digital AT register compatible
  13.             controllers.
  14.         
  15.     Program Name :    EASYDIAG.EXE  (previous versions USERDIAG.EXE)
  16.         
  17.  
  18.     1) REPORTS CORRECTABLE DATA ERRORS ... Previous versions
  19.            relied on a test of the STATUS register ONLY. USERDIAG
  20.        also has this limitation. If a correctable data error
  21.        is encountered, the test terminates and waits for
  22.        operator input.
  23.         
  24.     2) COMPLETE DOCUMENTATION ............ Details both the
  25.            (U)ser selected advanced test and the (A)utomatic
  26.        quick test. Error messages are verbosely explained in the
  27.        (A)utomatic quick test section of the document.
  28.         
  29.     3) COMMAND TIMEOUTS .................. Have been extended
  30.            to almost a minute on a 12Mhz AT (WDM20). This will
  31.        allow for 33Mhz 80386's with cache and controllers that
  32.        issue SLOW recals.
  33.         
  34.         4) ID FIELD RETRIES DISABLED AT ALL TIMES.
  35.         
  36.     5) STRAIGHT-LINE DRQ SERVICE .......... READ DRQ loop does not
  37.        store data (Write/Read Verify loop does, but more efficiently)
  38.        Complete test consisting of a re(Z)ero, 256 RANDOM seeks,
  39.        256 RANDOM two-sector reads, and 50 RANDOM data pattern
  40.        (W)rite / Read Verifies of last track takes approximately
  41.        30 sec. (CDC WREN II, 10 Mhz AT)
  42.  
  43.     6) BAD BLOCK ERRORS IGNORED .......... These errors are
  44.        reported to screen, but testing continues. This is the
  45.        ONLY error that is tolerated in the (A)utomatic or
  46.        (U)ser defined test menus.
  47.  
  48.         IMPROVEMENTS OF EZDIAG.EXE OVER USERDIAG.EXE
  49.         
  50.                 EZDIAG                                  USERDIAG
  51.         
  52.         Automatic Quick Test                            N/A
  53.     Dual test menu ... AUTO + SPECIFIC        Specific (A)ll Test
  54.     Bad Block Errors allowed            Terminates test
  55.         Retries Disabled                                Retries enabled
  56.         ECC Correctable Errors reported                 NOT REPORTED
  57.     Straight-line DRQ service loop            Iterative loop
  58.         Exit to DOS from DIAG menu                      N/A
  59.     Default sector count = 1            Default = 256
  60.         Congratulatory message                          "command successful"
  61.     Single keystroke test selection         Return required
  62.  
  63.  
  64.     Please forward any questions or suggestions to the SYSOP of
  65.     this BBS.
  66.  
  67.         
  68.     Regards,
  69.         
  70.     Mel Butler
  71.         WDC Dallas
  72.  
  73.  
  74.