home *** CD-ROM | disk | FTP | other *** search
- MKMSGF
- ECause: The value provided for the keyword in the
- IBMTRDB module in PROTOCOL.INI is not the correct type.
- User Action: Change the value in PROTOCOL.INI to
- the correct type for the parameter.
- ICause: An internal software error occurred.
- User Action: Contact your vendor sales representative.
- ICause: One or more IBM LANStreamer adapters
- are set to a different interrupt level. To function properly,
- these adapters must all be set to the same interrupt level.
- User Action: Use the reference diskette that came with your
- computer to ensure that all IBM LANStreamer adapters are set
- to the same interrupt level.
- ICause: The universally administered address of the
- adapter installed in the computer is displayed in this message.
- User Action: None.
- IExplanation: The locally administered address of the
- adapter installed in the computer is displayed in this message.
- User Action: None.
- ICause: The parameters specified require more space for
- processing than can be handled. The maximum allowable control-block
- size is 64KB.
- User Action: Reduce the value specified for the MAXTRANSMITS
- or MINRCVBUFFS parameter to change the amount of storage
- required for the control-blocks.
- The control-block area can be computed using the following formula:
- 1698 + (190 * MAXTRANSMITS) + (256 * MINRCVBUFFS)
- The control-block work area must be less than 64KB.
- ICause: The adapter is not responding to a request to
- initialize.
- User Action: Run the hardware diagnostics for the IBM LANStreamer
- Adapter. Contact your vendor sales representative.
- ICause: The IBM LANStreamer Adapter is operating at a data rate of 4 Mbps.
- User Action: None
- ICause: The IBM LANStreamer Adapter is operating at a data rate of 16 Mbps.
- User Action: None
- ICause: Only one occurrence of the device driver statement
- for the IBM LANStreamer Adapter NDIS MAC device driver is required
- to support multiple adapters. Additional instances of the device
- driver statement in CONFIG.SYS will be ignored.
- User Action: Remove the duplicate device driver statements from
- CONFIG.SYS.
- ICause: The parameter specifying the driver name (DRIVERNAME) was
- not found in PROTOCOL.INI. This parameter is required.
- User Action: Change PROTOCOL.INI to specify the proper information.
- ICause: An unexpected error occurred when the program attempted
- to open the protocol manager. The IBM LANStreamer Adapter NDIS MAC device
- driver has been removed.
- User Action: Check the drive and directory to ensure that
- the protocol manager is located in the specified path.
- ICause: The device driver was unable to register with
- the protocol manager.
- User Action: Reinstall the protocol manager and try the operation again.
- ICause: There was no adapter found in this machine. AN IBM LANStreamer
- Adapter is required to run the MAC device driver.
- User Action: Install an IBM TLANStreamer Adapter in this machine, or
- remove the device driver statement from CONFIG.SYS.
- ICause: An unrecognized parameter was found while processing
- the IBM LANStreamer Adapter section of PROTOCOL.INI.
- User Action: Correct the parameter or remove it from PROTOCOL.INI.
- ICause: The value specified for the network address parameter in
- PROTOCOL.INI is not valid for one of the following reasons:
- - Invalid local station address
- - Too long
- - Too short
- - Contains non-hexadecimal characters
- - Not enclosed in double quotes
- User Action: Remove or correct the network address parameter
- (NETADDRESS). A valid value for this parameter is 12 characters
- long, is enclosed in double quotes, and contains only valid
- hexadecimal characters within the range of 400000000000 through
- 7FFFFFFFFFFF.
- ICause: The network address that the adapter wants to use on the
- token-ring is being used by another node.
- User Action: Either modify PROTOCOL.INI to provide a different
- value for the network address (NETADDRESS) parameter, use the
- default burned-in address, or remove the other node that is
- using this network address from the ring.
- ICause: The ring speed is different from the speed of the
- node attempting to insert onto the ring.
- User Action: Use the reference diskette that came with your
- computer to ensure that the adapter is configured at the same
- speed as the token-ring.
- ICause: When the adapter tried to insert onto the token-ring, a
- hardware error occurred on the adapter.
- User Action: Run the hardware diagnostics for the IBM LANStreamer
- Adapter. Contact your vendor sales representative.
- ICause: While attempting to open the adapter, an indication was
- received that the adapter is not properly connected to the token-ring.
- User Action: Ensure that the token-ring cable is connected to
- the adapter and to the token-ring multistation access unit (MAU).
- If the error persists, use a different token-ring cable
- and check to ensure that the connection to the MAU is
- functioning properly. Then run the hardware diagnostics
- for the IBM LANStreamer Adapter.
- ICause: The configuration parameters specified require more space
- for processing than can be handled with the available system memory.
- User Action: Reduce the value specified for the MAXTRANSMITS
- or MINRCVBUFFS parameter to change the amount of storage required.
- The following formula can be used to compute the maximum value:
- H(i) = RCVAREA(i) + ALLOCSIZECB(i)
- A H(i) value should be computed for each IBM LANStreamer Adapter
- and the sum of all H(i) values must be less than 1 MB.
- The receive area for each adapter can be computed:
- RCVAREA = MINRCVBUFFS x SIZWORKBUF
- The control block area for each adapter can be computed using the
- following formula and must be less than 64KB.
- ALLOCSIZECB = 1698 + (190 * MAXTRANSMITS) + (256 * MINRCVBUFFS)
-