Int 14 Fn 8009  - Articom - Set Send And Receive Timeouts                  [S]

   AX = 8009h
   BX = send timeout in ticks
   CX = receive timeout in ticks
   DX = port index (COM1=0, COM2=1, ...)

Return: nothing

See Also: AX=8000h,AX=800Ah