home *** CD-ROM | disk | FTP | other *** search
/ Shareware Overload / ShartewareOverload.cdr / busi / photoast.zip / PHOTAST.DOC next >
Text File  |  1988-04-10  |  9KB  |  173 lines

  1.                         PHOTOGRAPHER'S ASSISTANT Ver. 1.0
  2.                                  Copyright 1988
  3.                                 Brian Allen Kuehn
  4.  
  5.      This is a SHAREWARE product.  You are invited to copy and distribute this 
  6. program provided that it is not modified in any way.  If you find it to be of 
  7. value to you, I expect you to pay for it.  It will have different values to 
  8. different people.  It is worth a maximum of $5.00 and a minimum of $1.00.  Send 
  9. me whatever it is worth to you within this range.  Your comments/suggestions 
  10. are hereby solicited.  Send cash and comments to:
  11.  
  12.                                 BRIAN ALLEN KUEHN
  13.                                  5815 CORD COURT
  14.                          PEORIA HEIGHTS, ILLINOIS  61614
  15.  
  16.  
  17.  
  18.  
  19.                                       -2-
  20.  
  21.                           ELECTRONIC FLASH CALCULATIONS
  22.      It would be nice if we all had access to studio strobes.  Most of us 
  23. don't.  When we want more light output, we generally start hooking up whatever 
  24. pieces of equipment that we have available in order to add up to the amount of 
  25. light desired.  With most of us, that means using unrelated pieces of equipment 
  26. that have different guide numbers.  Once you have assembled the various 
  27. strobes, how can you determine the amount of light that they will be putting 
  28. out when fired together?  This is not a simple question.
  29.      An easy way to measure the light output would be to use a flash meter to 
  30. measure the combined light output or use a polaroid back on the camera to make 
  31. some test exposures.  These items are not always available.
  32.      Any single flash unit used on manual (full power) produces a specific 
  33. amount of light.  How can that light output be described as a specific, finite 
  34. number?  I looked at guide numbers, B.C.P.S., and other conventional means of 
  35. describing light output.  My Metz flash has an A.S.A. 25 guide number of 93.  
  36. My Sunpack's A.S.A. 25 guide number is 50.  Does this mean that I can add 93 
  37. and 50 to reach an A.S.A. guide number of 143 for the two flashes combined?  No 
  38. way!  Attempting to do so is like comparing apples and oranges.
  39.      In studying a chart of various A.S.A. values and their corresponding guide 
  40. numbers, a pattern emerges:
  41.                           METZ 402: A.S.A. VALUES WITH 
  42.                            CORRESPONDING GUIDE NUMBERS
  43.  
  44.                                      ASA       GN
  45.                                      ____________
  46.                                       25 <  93
  47.                                       32 < 105.22
  48.                                       40 < 117.54
  49.                                       50 < 131.52
  50.                                       64 < 148.8
  51.                                       80 < 166.36
  52.                                      100 < 186
  53.                                      125 < 207.95
  54.                                      160 < 235.27
  55.                                      200 < 263.04
  56.                                      320 < 332.72
  57.                                      400 > 372
  58.                                      800 > 526.08
  59.                                      100 > 588.18
  60.                                     1600 > 744
  61.  
  62.      The chart shows A.S.A. values with corresponding guide numbers for my Metz 
  63. 402 flash used on manual (full power).  For A.S.A. values below 320, you will 
  64. notice that the A.S.A. values are smaller than their corresponding guide 
  65. numbers.  For A.S.A. values above 400, you will notice that the A.S.A. values 
  66. are larger than their corresponding guide numbers.  You have probably noticed 
  67. that the A.S.A. values increase at a proportionately greater rate then do their 
  68. corresponding guide numbers values.  This is because light falls off with the 
  69. square of the distance.  If you vary A.S.A. and guide number values in small 
  70. enough increments, you will eventually come to a point at which A.S.A. will 
  71. equal its corresponding guide number.  In the chart above, that point falls 
  72. somewhere between A.S.A. 320 and A.S.A. 400.
  73.  
  74.                                       -3-
  75.      The point at which A.S.A. value equals guide number provides the means to 
  76. compare apples and oranges.  These numbers, which I have arbitrarily named 
  77. "ABSOLUTE LIGHT VALUES" are additive.  To determine "ALV" for a particular 
  78. strobe you need any correct A.S.A./GN combination for the flash in question.  
  79. At A.S.A. 25, my Metz 402 flash has a guide number of 93.  Apply the following  
  80. formula:
  81.                (GN * GN)/A.S.A. = "ALV"
  82.  
  83.      93 squared is 8,649.  8,649 divided by 25 equals 345.96.  Thus 345.96 is 
  84. the "ALV" or ABSOLUTE LIGHT VALUE" for my Metz 402 flash.  If you plug any 
  85. other A.S.A./GN combination from the chart above into the formula above, you 
  86. will arrive at the same "ALV".  Try it!
  87.      Once you have determined "ALV" for a specific flash unit, it can be used 
  88. to calculate the guide number that corresponds to any A.S.A. which you might 
  89. wish to use.  The following formula applies: Take the square root of ("ALV" 
  90. times "DESIRED A.S.A.") = "GUIDE NUMBER".
  91.      Assume that you have acquired a small quantity of a rare Russian film that 
  92. has an A.S.A. value of 112.  Assume further that you are using my Metz 402 
  93. flash and that you need to know the correct guide number to use with this rare 
  94. Russian film.  You will recall that the "ALV" for my Metz 402 is 345.96.  Use 
  95. the formula set forth above.  345.96 ("ALV") times 112 (A.S.A. DESIRED) equals 
  96. 38,747.52.  The square root of 38,747.52 is 196.84.  The correct guide number 
  97. to use is 196.84.  
  98.      You can handle any combination of electronic flash units by adding their 
  99. individual "ABSOLUE LIGHT VALUES" together.  The total of the individual "ALV"s 
  100. is the "ALV" for the flashes used together.  These formulas are used in 
  101. portions of the .EXE file that you have.
  102.  
  103.  
  104.  
  105.                            DEPTH OF FIELD CALCULATIONS
  106.      Many cameras have depth of field markings engraved on their lens barrels.  
  107. Some of these are fairly accurate and some are not.  Most larger format cameras 
  108. do not have depth of field markings anywhere.  It can be very useful to know 
  109. exactly what your depth of field at any given aperture will be.  There are two 
  110. rorutines in the .EXE program supplied that rely on depth of field 
  111. calculations.  One routine will produce a depth of filed chart for all 
  112. apertures at a given focused distance.  The other routine will let you provide 
  113. the depth of field limits that you desire.  It will then tell you the point 
  114. that you need to focus on and the aperture that you need to use in order to 
  115. achieve the desired near and far depth of field limits.
  116.      The formulas used are derived from the following well know depth of field 
  117. formulas:
  118.                F = focal length of lens
  119.                f = f/stop of relative aperture
  120.                H = hyperfocal distance
  121.                u = distance focused upon
  122.                d = diameter of circle of confusion
  123.                O = angular size of circle of confusion.  For critical 
  124.                definition, O is 2 minutes of arc and the linear size of the 
  125.                circle of confusion is approximately f/1720 (tangent of 2 
  126.                minutes equals .00058).
  127.                L = effective diameter of lens = F/f
  128.  
  129.                                       -4-
  130. METHOD #1:
  131.      Near limit of depth of field (measured from camera lens):
  132.                                         (H * u)/(H + (u - F))
  133.  
  134.      Far limit of depth of field (measured from camera lens):
  135.                                         (H * u)/(H - (u - F))
  136.  
  137. METHOD #2 (used in the .EXE file):
  138.      Near limit of depth of field (measured from plane focused upon):
  139.                                         (u * u * tan O)/(L + u * tan O)
  140.  
  141.      Far limit of depth of field (measured from plane focused upon):
  142.                                         (u * u * tan O)/(L - u * tan O)
  143.  
  144.  
  145.      The results will change depending upon the angular size of the circle of 
  146. confusion used.  Since I assume that most people using this program are fairly 
  147. serious about photography and therefor rather fussy about the results achieved, 
  148. I have used 2 minutes of arc as the circle of confusion value in the .EXE 
  149. file.  
  150.      Hyperfocal distance is the minimun distance that you can focus at and 
  151. still be in focus clear to infinity.  This is useful if you want to be in focus 
  152. from infinity back to the closest possible distance.  This will give you the 
  153. widest total depth of field at any given aperture.  Hyperfocal distance varies 
  154. with the aperture selected.  Hyperfocal distances are given for each aperture 
  155. in the depth of field charting routine.
  156.      I would appreciate receiving any comments or suggestions for future 
  157. additions to this program.  It is written in Microsoft QuickBasic and is my 
  158. first attempt at programing in this language.  Comments can be left for me on 
  159. CompuServe although that is haphazard at best as I can go for months without 
  160. signing on to CompuServe.  It is probably better to communicate the old 
  161. fashioned way, either by mail or by phone.  My address is: Brian Allen Kuehn 
  162. (pronounced "Keen"), 5815 Cord Court, Peoria Heights, Illinois  61614.  Phone 1-
  163. (309)-688-6208.
  164.  
  165.  
  166.  
  167.  
  168.  
  169.  
  170.  
  171.  
  172.  
  173.