home
***
CD-ROM
|
disk
|
FTP
|
other
***
search
/
Boot Disc 11
/
boot-disc-1997-07.iso
/
Utils
/
Video
/
Ultimtte
/
data.z
/
Readme.txt
< prev
next >
Wrap
Text File
|
1997-04-15
|
9KB
|
252 lines
ULTIMATTE Plug-in Modules for Adobe Premiere
Version 2.0.1
4/15/97
These Disks contain the Ultimatte
Plugin Modules for Adobe Premiere for Windows 95 and Windows NT.
There are three PluginÆs, Ultimatte Image Compositer, Ultimatte
Screen Correction, and Ultimatte Grain Killer. The three plugin
modules have a .prm file extension. There are also three help
files that correspond to each of the plugin modules. The three
help modules have a .hlp file extension. Installation of the
Plugins under both Windows 95 and Windows NT consists of copying
these three files into the "Plugins" folder of Adobe Premiere.
The three help files can be copied anywhere on your hard disk.
You might consider putting them into the plugins folder as well.
Copy these six files from the floppy disk to the plugins
folder of Adobe Premiere.
FX-ULTIM.prm FX-SCRCR.prm FL-GKILL.prm
Ultimatte.hlp ScreenCorrect.hlp GrainKiller.hlp
The Ultimatte plugin modules are protected by a hardware
key that attaches to the parallel port of your computer. The
following section describes how to install the hardware key and
driver software.
Sentinel Drivers
Version 5.17
This section describes the installation procedures for
all Sentinel system drivers. See the appropriate section for the
procedure about the driver that you are installing.
------------------------------------------------
Contents
------------------------------------------------
1.0 Sentinel Key installation
2.0 Windows NT Driver Installation Procedure
2.1 Windows NT Driver Configuration
2.2 Windows NT Driver Un-install
3.0 Windows 95 Driver Installation Procedure
3.1 Windows 95 Driver Configuration
3.2 Windows 95 Driver Un-install
------------------------------------------------
1.0 Sentinel key installation
------------------------------------------------
1. To install a SentinelPro key, attach it to the parallel
printer port of an IBM PC/XT/AT or true IBM-compatible
computer. Typically the key is attached to LPT1.
------------------------------------------------
2.0 Windows NT Driver Installation Procedure
------------------------------------------------
1. Make a backup copy of the diskette.
2. Under the Microsoft Windows NT Main group, double click
on "Command Prompt".
3. Change drive to the floppy drive contains the Portable
Driver Diskette. In case of the floppy diskette
distribution, change the current directory to \WIN_NT.
In case of the CD-ROM distribution, change the current
directory to \PRODUCT\DRIVERS\WIN_NT.
4. Type "INSTALL.BAT" at the command prompt.
There are two command line options:
(See the INSTALL.BAT file for examples.)
1. /q Quiet mode.
Normal dialogs described below are not
displayed.
Error messages are displayed.
2. /pxxx Path, where xxx is the path of files to be
installed.
Specify the path of files to be installed.
Otherwise, files will be copied from the
default directory.
5. A window with the title bar "Sentinel Driver Setup Program" is
displayed.
6. Select "Functions" and then "Install Sentinel Driver" from
the menu bar.
7. A dialog box with the default path for the NT driver is
displayed. Change the drive letter if necessary and
click "OK".
8. The Sentinel Driver and associated files are copied to the
hard disk. One of the DLLs, SNTI386.DLL, SNTMIPS.DLL,
SNTALPHA.DLL, or SNTPPC.DLL and SENTTEMP.HLP are copied
to \%SYSTEMROOT%\SYSTEM32. SENTTEMP.SYS is copied to the
file \%SYSTEMROOT%\SYSTEM32\DRIVERS\SENTINEL.SYS.
%SYSTEMROOT% is the directory where Microsoft Windows NT
has been installed.
9. If the driver installation is successful, a dialog box
with the message "Sentinel Driver Files Copied
Successfully" is displayed.
10. When complete, a dialog box with the message "Driver
Installed! Restart your system" is displayed.
11. Click "OK" to continue.
12. Restart your computer.
-------------------------------------------------
2.1 Windows NT Driver Configuration Procedure
-------------------------------------------------
If your system setting has been changed and you would like to
reconfigure the Sentinel Driver, perform the following steps.
1. Under the Microsoft Windows NT Main group, double click on
"Control Panel".
2. Under the Control Panel double click on "Drivers".
3. Select "Sentinel for i386 System" in the installed driver
list box.
4. Click the "Setup" button.
5. Click the "Edit" button to edit an existing parallel port
setting or click the "Add" button to add a new parallel
port setting. Select "OK" after you finish the port
configuration.
6. A dialog box with the message "Your driver setting has
changed" is displayed. You will need to exit and restart
Windows NT so that the new setting can take effect."
7. If you have any other application running at the
background with unsaved data, choose "Don't Restart Now".
Quit all the application and restart Windows NT, Otherwise
select "Restart Now".
------------------------------------------------
2.2 Windows NT Driver Un-install
------------------------------------------------
1. Under the Microsoft Windows NT Main group, double click on
"Command Prompt".
2. Change drive to the floppy drive contains the Portable
Driver Diskette. In case of the floppy diskette
distribution, change the current directory to \WIN_NT.
In case of the CD-ROM distribution, change the
current directory to \PRODUCT\DRIVERS\WIN_NT.
3. Run "INSTALL.BAT" from the command prompt.
1. Use Command-line options: (See the INSTALL.BAT file for
examples.)
/q /u - Quietly removes the existing
driver.
2. Via Pull-down menu - Run INSTALL.BAT and select
"Remove Sentinel
Driver" from the "Function"
menu.
4. When complete, a dialog box with the message "Sentinel
Driver Removed" is displayed.
5. Click "OK" to continue.
Note: Some files may not be removed until you restart your
computer.
------------------------------------------------
3.0 Windows 95 Driver Installation Procedure
------------------------------------------------
1. Make a backup copy of the diskette.
2. Start Windows 95. Select "Run" from the Taskbar and run
the file SENTW95.EXE in the \WIN_95 subdirectory on the
driver diskette. There are two command line options:
1. /q Quiet mode.
Normal dialogs described below are not
displayed. Error messages are displayed.
2. /pxxx Path, where xxx is the path of files to be
installed. Specify the path of files to be
installed. Otherwise, files will be copied
from the default directory.
3. Select "Install Sentinel Driver" from the "Functions" menu.
4. Click "OK" when the "Driver installed! Restart your system."
message appears. Restart Windows 95.
5. The following files have been created on your hard disk:
WINDOWS\SYSTEM\SENTINEL.VXD
WINDOWS\SYSTEM\RNBOSENT\SENTW95.EXE
WINDOWS\SYSTEM\RNBOSENT\SENTW95.DLL
WINDOWS\SYSTEM\RNBOSENT\SENTW95.HLP
WINDOWS\SYSTEM\RNBOSENT\SENTINEL.SAV
------------------------------------------------
3.1 Windows 95 Driver Configuration
------------------------------------------------
1. Start Windows 95. Select "Run" from the Taskbar and run
the file SENTW95.EXE in the WINDOWS\SYSTEM\RNBOSENT
subdirectory.
2. Select "Configure Sentinel Driver" from the "Functions"
menu.
3. Click the "Edit" button to edit an existing parallel port
setting or click the "Add" button to add a new parallel
port setting. Select "OK" after you finish the port
configuration.
4. Restart Windows 95 for the changes to take effect.
------------------------------------------------
3.2 Windows 95 Driver Un-install
------------------------------------------------
1. Start Windows 95. Select "Run" from the Taskbar and run
the file SENTW95.EXE in the WINDOWS\SYSTEM\RNBOSENT
subdirectory (or from the original distribution media).
The driver can be removed via the command-line options or
the pull-down menu.
a. Command-line options:
SENTW95 /q /u - Quietly removes the existing driver.
b. Pull-down menu:
Select "Remove Sentinel Driver" from the "Funtion"
menu.
2. When complete, a dialog box with the message "Sentinel
Driver Removed" is displayed.
3. Click "OK" to continue.