home *** CD-ROM | disk | FTP | other *** search
/ Monster Media 1993 #2 / Image.iso / lan / lock175.zip / MAN175.TXT < prev   
Text File  |  1993-07-22  |  19KB  |  425 lines

  1. ----------------------------------------------------------------------
  2.                                  LOCKER v1.75 Demo 
  3.  
  4.   Thank you for Trying LOCKER v1.75 for DOS & WINDOWS. Please
  5.   notify us if you encounter any problems with LOCKER. 
  6.  
  7.   You are allowed to use this DEMO of LOCKER for 30 days. After 30 days
  8.   you should either purchase LOCKER or STOP USING the DEMO.
  9.   You are allowed to give/distribute this demo to anyone ONLY IF it
  10.   is given with this documentation and is FREE.
  11.  
  12.   We are interested in what you think about LOCKER -
  13.   what additional feature you would like to see, what you don't like about it,
  14.   and what you do like about it. Depending on what feedback I
  15.   receive, additional features may be added !
  16.  
  17. ----------------------------------------------------------------------
  18.  
  19.  
  20. Table of Contents
  21.  
  22. Chapter 1:
  23.     1.1 What is Locker
  24.     1.2 Requirements
  25.  
  26. Chapter 2:
  27.      2.1 Upgrading
  28.     2.2 New Installation
  29.  
  30. Chapter 3:
  31.     3.1 Screen layout and commands
  32.     3.2 Installing metering on software
  33.     3.3 Changing metering limits on software
  34.     3.4 Removing metering from software
  35.     3.5 Metering applications which reside on local drives
  36.  
  37. Chapter 4:
  38.     4.1 Common Mistakes & Problems
  39.     4.2 What not to do
  40.  
  41.     
  42.  
  43. CHAPTER 1: INTRODUCTION
  44.  
  45. 1.1 What is LOCKER
  46.  
  47. LOCKER is a program which meters software on a network. It controls the
  48. number of users that may run a DOS or WINDOWS executable (*.COM & *.EXE files)
  49. concurrently. You can also meter software which resides on a local hard disk,
  50. in this case the user will only be able to run the program when they are logged
  51. in to the network.
  52.  
  53. LOCKER is run from a console from which you can:
  54. Add metering to a program,
  55. Change the metering limit on a program,
  56. Remove the metering from a program,
  57. See the number of active users for a program,
  58. See what the peak number of users was for a program,
  59. See the number of times a user had to wait to run a program
  60. See the number of times a user canceled out of waiting for a program to
  61.     be available.
  62.  
  63. You should check the licensing agreement for the software that you are installing 
  64. metering on, some licensing requires that you own a copy of the software for each
  65. person who may use the software. LOCKER is NOT a substitute for purchasing the
  66. legal number of copies required.
  67.  
  68. LOCKER works with most DOS networks which support DOS file sharing and locking.
  69. It has been tested with Novell's Netware, Banyan's Vines, Microsoft's LAN Manager,
  70. and with Lantastic Networks.
  71.  
  72. 1.2 Requirements
  73.  
  74. LOCKER requires DOS 3.3 or higher, while it may work with older versions of
  75. DOS, we cannot guarantee that it will. LOCKER adds a 3K memory overhead to
  76. running a metered DOS application. In cases where there is not enough memory to
  77. load a metered software, you should try to remove any TSR which are not needed. 
  78. It is not recommended that you install metering on any memory mapping software
  79. products since you may receive an invalid result. 
  80.  
  81.  
  82. CHAPTER 2: INSTALLATION
  83. 2.1 Upgrading
  84.  
  85. You should remove metering from all programs you are currently metering.
  86. Then proceed with the normal install except you should copy the LOCKER files
  87. to a different directory than where you had your old LOCKER files. This way if
  88. there is a problem you can easily remeter using your older version of LOCKER.
  89.  
  90.  
  91. 2.2 New Installation
  92.  
  93. This installation assumes some knowledge of DOS. If you have problems with
  94. the commands, please look them up in your DOS manual.
  95.  
  96. First copy the LOCKER disk to a drive\directory where only the SUPERVISOR
  97. or NETWORK ADMINISTRATOR has access. For example:
  98.   Copy A:*.* F:\SYSTEM\*.*
  99.  
  100.  
  101. Now change to the directory where you installed LOCKER. In the example before
  102. this would be:
  103.    F:
  104.    CD \SYSTEM
  105.  
  106.  
  107. Next run the LOCKCON program. Type:
  108.   LOCKCON 
  109.  
  110.  
  111. After starting LOCKCON you will see the following screen:
  112. ┌──────────────────────────────────────────────────────────────────────────────┐
  113. │  UPDATE:                     LOCKER v1.75.1 Console                          │
  114. │                                                                              │
  115. │                                           PEAK                       TOTAL   │
  116. │PROGRAM:       TYPE:   LIMIT:   CURRENT:   USED:   WAITS:   ABORTS:  ACCESS:  │
  117. │                                                                              │
  118. │                                                                              │
  119. │                                                                              │
  120. │                                                                              │
  121. │                                                                              │
  122. │                                                                              │
  123. │                                                                              │
  124. │              ┌─────────────────────────────────────────────────┐             │
  125. │              │ Enter Directory Path for LOG files:             │             │
  126. │              │                                                 │             │
  127. │              │                                                 │             │
  128. │              └─────────────────────────────────────────────────┘             │
  129. │                                                                              │
  130. │                                                                              │
  131. │                                                                              │
  132. │                                                                              │
  133. │                                                                              │
  134. │F2=TOGGLE UPDATE ON/OFF      F4=OPTIONS                                       │
  135. │F3=UPDATE     INS=Install    DEL=UnInstall    ENTER=Change Count    ESC=Exit  │
  136. └──────────────────────────────────────────────────────────────────────────────┘
  137.  
  138.  
  139.  
  140. For the log file path you should enter a directory (it does not need to currently exist)
  141. where all your users will have full access to. Fox example, if you entered
  142. F:\PUBLIC\LOCKER all your users would need to have a drive F: and have full
  143. read/write access to the F:\PUBLIC\LOCKER directory. This directory should
  144. NOT be the same as the directory where you copied the LOCKER files.
  145.  
  146. Please Note: That for all paths that are entered via LOCKCON you should use
  147. the standard DOS paths not network specific paths (for example: do not use
  148. SERVER01\SYS:\PUBLIC, use instead \PUBLIC .or Z:\PUBLIC - where Z: would be a
  149. drive mapped to the volume SYS:)
  150.  
  151. You have now installed LOCKER and are ready to start metering you applications.
  152.  
  153.  
  154. CHAPTER 3. USING LOCKER
  155.  
  156. 3.1 Screen Layout and commands
  157.  
  158. To run LOCKER you must either be in the directory where you installed it or
  159. it must be in your path statement. To start LOCKER at the DOS prompt type
  160. LOCKCON. This will bring up Locker's console:
  161.  
  162. ┌──────────────────────────────────────────────────────────────────────────────┐
  163. │  UPDATE: ON                  LOCKER v1.75.1 Console                          │
  164. │                                                                              │
  165. │                                           PEAK                       TOTAL   │
  166. │PROGRAM:       TYPE:   LIMIT:   CURRENT:   USED:   WAITS:   ABORTS:  ACCESS:  │
  167. │ TEST.EXE       DOS      001        000     0000     0000      0000     0000  │
  168. │                                                                              │
  169. │                                                                              │
  170. │                                                                              │
  171. │                                                                              │
  172. │                                                                              │
  173. │                                                                              │
  174. │                                                                              │
  175. │                                                                              │
  176. │                                                                              │
  177. │                                                                              │
  178. │                                                                              │
  179. │                                                                              │
  180. │                                                                              │
  181. │                                                                              │
  182. │                                                                              │
  183. │                                                                              │
  184. │F2=TOGGLE UPDATE ON/OFF      F4=OPTIONS                                       │
  185. │F3=UPDATE     INS=Install    DEL=UnInstall    ENTER=Change Count    ESC=Exit  │
  186. └──────────────────────────────────────────────────────────────────────────────┘
  187.  
  188. For each program being metered you will see the following information:
  189.  
  190. PROGRAM: Either the program executable file name or the description
  191.  
  192. TYPE: Whether a program is a DOS or WINDOWS (DOS/WIN) based
  193.  
  194. LIMIT:    How many users can use the program concurrently
  195.  
  196. CURRENT: How many users are currently using the program
  197.  
  198. PEAK USED: Peak number of concurrent users 
  199.  
  200. WAITS: Number of users who had to wait to access the program
  201.  
  202. ABORTS: Number of users who canceled out of waiting for the program to be
  203.   available
  204.  
  205. TOTAL ACCESS: Number of times the program has been run
  206.  
  207. From LOCKCON  you can  either install metering on software, change the metering
  208.  limits or remove metering from software.
  209.  
  210.  
  211. Actions you can do from this screen:
  212.  
  213. To install metering on a software product press <INS> key
  214.  
  215. To highlight a displayed software product use the arrow keys
  216.  
  217. To change the metering limit, first highlight the software name and then press
  218.  the <ENTER> key.
  219.  
  220. To remove metering from a software product, first highlight the software name
  221.  and then press the <DEL> key.
  222.  
  223. To toggle on/off the updating for the LOCKCON press <F2>. The current status
  224.  of the updating can be seen in the upper left corner of the LOCKCON screen
  225.  
  226. To force the LOCKCON screen to refresh/update press <F3>
  227.  
  228. To change the interval at which the LOCKCON screen updates press <F4>
  229.  
  230. To exit from LOCKCON press <ESC>
  231.  
  232. 3.2 Install metering on software
  233.  
  234. After pressing the <INS> key an entry screen will be displayed:
  235.  
  236. ┌──────────────────────────────────────────────────────────────────────────────┐
  237. │  UPDATE: ON                  LOCKER v1.75.1 Console                          │
  238. │                                                                              │
  239. │                                           PEAK                       TOTAL   │
  240. │PROGRAM:       TYPE:   LIMIT:   CURRENT:   USED:   WAITS:   ABORTS:  ACCESS:  │
  241. │ TEST.EXE       DOS      001        001     0000     0000      0000     0000  │
  242. │                                                                              │
  243. │                                                                              │
  244. ┌──────────────────────────────────────────────────────────────────────────────┐
  245. │                            Add a new program to LOCKER                       │
  246. │                                                                              │
  247. │Program Name:               Type: DOS  Limit: 001 Scan Time: 015 Log: ON      │
  248. │Module  Name:                                                                 │
  249. │Program Desc:                                                                 │
  250. │Program Path:                                                                 │
  251. │                                                                              │
  252. └──────────────────────────────────────────────────────────────────────────────┘
  253. │                                                                              │
  254. │                                                                              │
  255. │                                                                              │
  256. │                                                                              │
  257. │                                                                              │
  258. │                                                                              │
  259. │                             ESC=Abort Changes           F10=Accept Changes   │
  260. └──────────────────────────────────────────────────────────────────────────────┘
  261.  
  262. Program Name:  Enter the software executable name (for example: TEST.EXE - do
  263.  not include that program path).
  264.  
  265. Type:    You can press the <space bar> to toggle the program type from DOS to
  266.  WIN (i.e. a windows program).
  267.  
  268. Limit:    Enter the maximum number of concurrent users allowed.
  269.  
  270. Scan Time:    Enter how often you want the program to check to see if a license
  271.  is available.
  272.  
  273. Log:    Use the <space bar> to toggle it on and off. This field controls whether
  274.  the extended log information is kept.
  275.  
  276. Module name:     Leave it blank unless the main program actually starts another
  277.  module/program and then terminates. (Only used for windows programs)
  278.  
  279. Program Desc:    Enter a descriptive name for the program. This field will be displayed
  280.  instead of the program name on the LOCKCON screen and when a user is notified that all concurrent licenses are in use. 
  281.  
  282. Program Path:    Enter either the directory or the drive:\directory of where the
  283.  software is located. Please note that you should have the same drive configuration
  284.  each time you run LOCKCON since otherwise you may not be able to change or
  285.  remove the metering. After you are finished entering the information, you can
  286.  either escape from adding metering <ESC>, or install the metering by pressing 
  287.  the <F10> key.
  288.  
  289. 3.3 Changing metering limits on software
  290.  
  291. After highlighting the software you wish to change the metering on and pressing
  292.  <ENTER> the same screen as when you installed the metering will be displayed.
  293.  However, you will only be able to change the user limit. After making your
  294.  changes, press <F10> to accept them or <ESC> to abort.
  295.  
  296. 3.4 Removing metering from software
  297.  
  298. After highlighting the software you wish to remove the metering from and pressing
  299.  <DEL>; you will be prompted (Y/N) as to whether you really wish to remove metering.
  300.  Please note, you will only be able to remove metering when the software executable
  301.  is not in use.
  302.  
  303. 3.5 Metering applications on Local hard drives
  304.  
  305. There are two way of metering applications residing on local hard drives
  306.  
  307. 1) You can either install the application on the network,  install metering, and then
  308.  copy all the files to the each local hard drive (Make certain you copy all hidden files
  309.  which reside in the application directory)
  310.  
  311. 2) Install the application on the local drive, copy the executable file to its own directory
  312.  on the network, install metering on the executable on the network, and then copy the
  313.  metered executable and any hidden files in the directory back to the users local drives.  
  314.  
  315. After changing the metering limits for applications residing on local drives you
  316.  DO NOT have to redistribute the network files.
  317.  
  318. After removing metering from an application residing on a local drive you must either
  319.  erase all copies of the application which reside on the local drives or copy the network
  320.  executable to all the local users drives.
  321.  
  322. Chapter 4: ERROR MESSAGES
  323.  
  324. 4.1  Common Mistakes & Problems
  325.  
  326. Most of the problems will be covered by the messages below. Since LOCKER does run
  327. on a wide variety of networks, you might get a problem which is not covered
  328. below. If you do, you can call us at (800) NET-SOFT or leave a message on
  329. Compuserve to 72607,3042 and we will try to resolve your problem as fast as
  330. possible.
  331.  
  332. If you are using Norton's Desktop for Windows you will need to make the
  333. <filename>.@@@  file unhidden.
  334.  
  335. ex. Attrib TEST.@@@ -H
  336.  
  337. For  WORD PERFECT for windows, you need to copy the WPWINFIL.EXE file in the
  338.  WordPerfect directory to WPWINFIL.@@@
  339.  
  340. ex. copy F:\wp51\wpwinfil.exe f:\wp51\wpwinfil.@@@
  341.  
  342. LOCKCON Error Messages:
  343.  
  344. INSTALL MESSAGES
  345.  
  346. Invalid Filename or Path
  347.      Check to make sure that the filename and path are correct
  348.  
  349. LOCKER already installed on file
  350.     Metering has already been installed on the program
  351.  
  352. File is in use
  353.     Check the use field on the main screen. If it displays __, then your
  354.         drive/path configuration has changed and LOCKER can not locate the
  355.         file. Otherwise it does mean that the file is in use.
  356.  
  357.     The supervisor can run a metered program but the users can not.  You
  358.         have not granted rights to the log file path directory. (This is the
  359.         directory which you entered when you first ran LOCKER.
  360.  
  361.     Metering was installed but the program still allows everyone to
  362.         access it. The program probably starts another program and then exits.
  363.         You should call technical support to see if we already know what the
  364.         name should be for the module name field.
  365.  
  366.     You are having difficulty metering windows. You should install metering
  367.         on progman.exe (its a windows program) instead of win.com or win.exe.
  368.  
  369. 4.2  What not to do:
  370.  
  371.     DO NOT erase any hidden files which reside in the applications directory
  372.         after installing metering. Locker uses these files and if they are removed
  373.         prior to removing metering you will have to reinstall your original executable
  374.         program.
  375.  
  376.     DO NOT erase the LOCKCON files before removing metering on all metered applications.
  377.         The applications will still be metered after LOCKCON is removed and you will have
  378.         to call technical support to remove the metering.
  379.  
  380.  
  381.  
  382. ----------------------------------------------------------------------
  383.  
  384. The following licenses for LOCKER v1.75 are available:
  385.  
  386.    LOCKER v1.75: USD $ 95 / server   (S/H not included)
  387.  
  388.  
  389.   
  390. We accept CHECKS, MONEY ORDERS, and MC/VISA.
  391.    
  392. If you want more information on LOCKER or if you decide to purchase LOCKER
  393. we can be contacted at:
  394.  
  395.                            VERITAS TECHNOLOGIES, INC.
  396.                            12750 MERIT DRIVE, SUITE 830
  397.                            DALLAS,TX 75251
  398.  
  399.                            TEL: (214)-387-1812
  400.                            FAX: (214)-392-2568
  401.  
  402.                            Compuserve Address: 72576,3352
  403.  
  404.  
  405.   INTERNATIONAL Sales via MC/VISA. 
  406.  
  407.  
  408.  
  409. And NOW for the usual disclaimers:
  410.  
  411. NO OTHER WARRANTIES. VERITAS TECHNOLOGIES disclaims all other warranties,
  412. either express or implied, including but not limited to implied warranties
  413. of mechantability and fitness for a particular purpose, with respect to the
  414. software, the accompanying written materials, and any accompanying hardware.
  415. This limited warranty gives you specific legal rights. You may have others,
  416. which vary from state to state.
  417.  
  418. NO LIABILITY FOR CONSEQUENTIAL DAMAGES. In no event shall VERITAS TECHNOLOGIES
  419. or its suppliers be liable for any damages whatsoever caused by the use of or
  420. inability to use this VERITAS TECHNOLOGIES product. Because some states do not
  421. allow the exclusion or limitation of liability for consequential of incidental
  422. damages, the above limitation may not apply to you.
  423.  
  424. ----------------------------------------------------------------------
  425.