home *** CD-ROM | disk | FTP | other *** search
/ Monster Media 1993 #2 / Image.iso / ham / prd793.zip / TS530SP < prev    next >
Text File  |  1991-02-20  |  991b  |  14 lines

  1. I would like to pass on the problem I have encountered inconnection with the
  2. QRO modification to the Kenwood TS830S, TS-530S and the TS-530SP.
  3. The problem occurs after many hours of long winded QSO's.  It seems that with
  4. the increase in the screen voltage from 210 to 300 volts, R37 on the RF unit
  5. (#X44-1360-00) heats up tremendously and will change it's value so greatly
  6. that even the receive either suffers or goes out totally.  R37 originally is
  7. Metalfilm resistor at 3.3K ohms and is 1/2 watt.  I have changed mine to a
  8. Metalfilm as original same value but have used a one watt resistor.  The brand
  9. I was able to get was RCA and I suppose there are better on the market.
  10. This is a 2% tolerance.  Three units that I know of have had this problem that
  11. I took care of in this area alone.  Two units were TS-830S and one a TS-530SP.
  12. Just thought I would pass that information along for what it is worth.
  13. (Thanks, FrankJ. Lukas, Jr., 5301 Main Ave., North Ridgeville, OH 44039)
  14.