home *** CD-ROM | disk | FTP | other *** search
/ The Unsorted BBS Collection / thegreatunsorted.tar / thegreatunsorted / texts / pirate_radio / fccpt15.faq < prev    next >
Internet Message Format  |  1994-10-01  |  11KB

  1. From netcom.com!netcomsv!decwrl!lambda.msfc.nasa.gov!newsxfer.itd.umich.edu!europa.eng.gtefsd.com!MathWorks.Com!solaris.cc.vt.edu!uunet!world!hrick Sun Sep 25 17:28:46 1994
  2. Xref: netcom.com alt.radio.pirate:5265 sci.electronics:93995
  3. Newsgroups: alt.radio.pirate,sci.electronics
  4. Path: netcom.com!netcomsv!decwrl!lambda.msfc.nasa.gov!newsxfer.itd.umich.edu!europa.eng.gtefsd.com!MathWorks.Com!solaris.cc.vt.edu!uunet!world!hrick
  5. From: hrick@world.std.com (Rick Harrison)
  6. Subject: FCC Part 15 Rules FAQ
  7. Message-ID: <Cvsv25.A0s@world.std.com>
  8. Followup-To: poster
  9. Organization: The World Public Access UNIX, Brookline, MA
  10. Distribution: na
  11. Date: Thu, 8 Sep 1994 07:20:29 GMT
  12. Expires: Sat, 8 Oct 1994 23:59:00 GMT
  13. Lines: 217
  14.  
  15.  
  16. excerpts from FCC "Part 15" rules
  17. (Title 47 of the Code of Federal Regulations, Part 15)
  18.  
  19.  
  20. Subpart A -- General
  21.  
  22.  
  23. 15.1 Scope of this part.
  24.  
  25. (a) This part sets out the regulations under which an intentional,
  26. unintentional, or incidental radiator may be operated without an
  27. individual license.  It also contains the technical specifications,
  28. administrative requirements and other conditions relating to the
  29. marketing of part 15 devices.
  30.  
  31.  
  32. 15.5 General conditions of operation.
  33.  
  34. (b) Operation of an intentional, unintentional, or incidental radiator
  35. is subject to the conditions that no harmful interference is caused
  36. and that interference must be accepted that may be caused by the
  37. operation of an authorized radio station, by another intentional or
  38. unintentional radiator, by industrial, scientific and medical (ISM)
  39. equipment, or by an incidental radiator.
  40.  
  41. (c) The operator of a radio frequency device shall be required to cease
  42. operating the device upon notification by a Commission representative
  43. that the device is causing harmful interference.  Operation shall not
  44. resume until the condition causing the harmful interference has been
  45. corrected.
  46.  
  47.  
  48. 15.23 Home-built devices.
  49.  
  50. (a) Equipment authorization is not required for devices that are not
  51. marketed, are not constructed from a kit, and are built in quantities
  52. of five or less for personal use.
  53.  
  54. (b) It is recognized that the individual builder of home-built equipment
  55. may not possess the means to perform the measurements for determining
  56. compliance with the regulations.  In this case, the builder is expected
  57. to employ good engineering practices to meet the specified technical
  58. standards to the greatest extent practicable.  The provisions of 15.5
  59. apply to this equipment.
  60.  
  61.  
  62. 15.35 Measurement detector functions and bandwidths.
  63.  
  64. (b) ...When average radiated emission measurements are specified in the
  65. regulations, including emission measurements below 1000 MHz, there is
  66. also a limit on the radio frequency emissions, as measured using
  67. instrumentation with a peak detector function, corresponding to 20 dB
  68. above the maximum permitted average limit for the frequency being
  69. investigated.
  70.  
  71.  
  72. Subpart C -- Intentional Radiators
  73.  
  74.  
  75. 15.207 Conducted limits.
  76.  
  77. (a) For an intentional radiator which is designed to be connected to the
  78. public utility (AC) power line, the radio frequency voltage that is
  79. conducted back onto the AC power line on any frequency or frequencies
  80. within the band 450 kHz to 30 MHz shall not exceed 250 microvolts.
  81. Compliance with this provision shall be based on the measurement of
  82. the radio frequency voltage between each power line and ground at the
  83. power terminals.
  84.  
  85. (c) The limit shown in paragraph (a) of this section shall not apply
  86. to carrier current systems operating as intentional radiators on
  87. frequencies below 30 MHz.  In lieu thereof, these carrier current
  88. systems shall be subject to the following standards:
  89.  (1) For carrier current systems containing their fundamental emission
  90. within the frequency band 535-1705 kHz and intended to be received
  91. using a standard AM broadcast receiver: no limit on conducted emissions.
  92.  (2) For all other carrier current systems: 1000 uV within the frequency
  93. band 535-1705 kHz.
  94.  
  95.  
  96. 15.209 Radiated emission limits; general requirements.
  97.  
  98. (a) Except as provided elsewhere in this subpart, the emissions from
  99. an intentional radiator shall not exceed the field strength levels
  100. specified in the following table:
  101.  
  102.                  |   Field strength       |   Measurement distance
  103. Frequency (MHz)  |   (microvolts/meter)   |   (meters)
  104. -----------------+------------------------+-----------------------
  105. 0.009-0.490          2400/F(kHz)               300
  106. 0.490-1.705          24000/F(kHz)               30
  107. 1.705-30.0           30                         30
  108. 30-88**              100**                       3
  109. 88-216**             150**                       3
  110. 216-960              200**                       3
  111. Above 960            500                         3
  112. -----------------+------------------------+-----------------------
  113.  
  114. **Except as provided in paragraph (g), fundamental emissions from
  115. intentional radiators operating under this Section shall not be
  116. located in the frequency bands 54-72 MHz, 76-88 MHz, 174-216 MHz or
  117. 470-806 MHZ. 
  118.  
  119.   {Editor's note: paragraph (g) allows perimeter protection systems
  120.   and biomedical telemetry devices to use the frequency bands 54-72 MHz, 
  121.   76-88 MHz, 174-216 MHz or 470-806 MHZ.  These are TV broadcast channels.
  122.   No other unlicensed transmissions on TV frequencies are permitted.}
  123.   
  124.   
  125. 15.215 Additional provisions to the general radiated emission limitations.
  126.  
  127. (a) The regulations in 15.217 through 15.251 provide alternatives to the
  128. general radiated emission limits for intentional radiators operated in
  129. specified frequency bands.  Unless otherwise stated, there are no
  130. restrictions as to the types of operation permitted under these sections.
  131.  
  132.  
  133. 15.217 Operation in the band 160-190 kHz.
  134.  
  135. (a) The total input power to the final radio frequency stage (exclusive
  136. of filament or heater power) shall not exceed one watt.
  137.  
  138. (b) The total length of the transmission line, antenna, and ground lead
  139. (if used) shall not exceed 15 meters.
  140.  
  141. (c) All emissions below 160 kHz or above 190 kHz shall be attenuated at
  142. least 20 dB below the level of the unmodulated carrier.  Determination
  143. of compliance with the 20 dB attenuation specification may be based on
  144. measurements at the intentional radiator's antenna output unless the
  145. intentional radiator uses a permanently attached antenna, in which case
  146. compliance shall be demonstrated by measuring the radiated emissions.
  147.  
  148.  
  149. 15.219 Operation in the band 510-1705 kHz.
  150.  
  151. (a) The total input power to the final radio frequency stage (exclusive of
  152. filament or heater power) shall not exceed 100 milliwatts.
  153.  
  154. (b) The total length of the transmission line, antenna and ground lead
  155. (if used) shall not exceed 3 meters.
  156.  
  157. (c) All emissions below 510 kHz or above 1705 kHz shall be attenuated at
  158. least 20 dB below the level of the unmodulated carrier.  Determination
  159. of compliance with the 20 dB attenuation specification may be based on
  160. measurements at the intentional radiator's antenna output unless the
  161. intentional radiator uses a permanently attached antenna, in which case
  162. compliance shall be demonstrated by measuring the radiated emissions.
  163.  
  164.  
  165. 15.221 Operation in the band 525-1705 kHz.
  166.  
  167. (a) Carrier current systems and transmitters employing a leaky coaxial
  168. cable as the radiating antenna may operate in the band 525-1705 kHz
  169. provided the field strength levels of the radiated emissions do not
  170. exceed 15 uV/m, as measured at a distance of 47.715/(frequency in kHz)
  171. meters (equivalent to Lambda/2Pi) from the electric power line or the
  172. coaxial cable, respectively.  The field strength levels of emissions
  173. outside this band shall not exceed the general radiated emission limits
  174. in 15.209.
  175.  
  176. (b) As an alternative to the provisions in paragraph (a) of this section,
  177. intentional radiators used for the operation of an AM broadcast station
  178. on a college or university campus or on the campus of any other
  179. education institution may comply with the following:
  180.  (1) On the campus, the field strength of emissions appearing outside
  181. of this frequency band shall not exceed the general radiated emission
  182. limits shown in 15.209 as measured from the radiating source.  There
  183. is no limit on the field strength of emissions appearing within this
  184. frequency band, except that the provisions of 15.5 continue to comply.
  185. {Editor's note: they probably meant "continue to apply."}
  186.  (2) At the perimeter of the campus, the field strength of any emissions,
  187. including those within the frequency band 525-1705 kHz, shall not exceed
  188. the general radiated emission in 15.209.
  189.  (3) The conducted limits specified in 15.207 apply to the radio
  190. frequency voltage on the public utility power lines outside of the
  191. campus.  Due to the large number of radio frequency devices which may
  192. be used on the campus, contributing to the conducted emissions, as an
  193. alternative to measuring conducted emissions outside of the campus,
  194. it is acceptable to demonstrate compliance with this provision by
  195. measuring each individual intentional radiator employed in the system
  196. at the point where it connects to the AC power lines.
  197.  
  198. (c) A grant of equipment authorization is not required for intentional
  199. radiators operated under the provisions of this Section.  In lieu
  200. thereof, the intentional radiator shall be verified for compliance with
  201. the regulations in accordance with subpart J of part 2 of this chapter.
  202. This data shall be kept on file at the location of the studio, office
  203. or control room associated with the transmitting equipment.  In some
  204. cases, this may correspond to the location of the transmitting equipment.
  205.  
  206. (d) For the band 535-1705 kHz, the frequency of operation shall be chosen
  207. such that operation is not within the protected field strength contours
  208. of licensed AM stations.
  209.  
  210.  
  211. 15.239 Operation in the band 88-108 MHz.
  212.  
  213. (a) Emissions from the intentional radiator shall be confined within a
  214. band 200 kHz wide centered on the operating frequency.  The 200 kHz band
  215. shall lie wholly within the frequency range of 88-108 MHz.
  216.  
  217. (b) The field strength of any emissions within the permitted 200 kHz
  218. band shall not exceed 250 microvolts/meter at 3 meters.  The emission
  219. limit in this paragraph is based on measurement instrumentation employing
  220. an average detector.  The provisions in 15.35 for limiting peak emissions
  221. apply.
  222.  
  223. (c) The field strength of any emissions radiated on any frequency outside
  224. of the specified 200 kHz band shall not exceed the general radiated
  225. emission limits in 15.209.
  226.  
  227.  
  228.  
  229.  
  230. -- 