home *** CD-ROM | disk | FTP | other *** search
/ Phoenix Rising BBS / phoenixrising.zip / phoenixrising / phreak / misp34.txt < prev    next >
Text File  |  1992-03-04  |  11KB  |  348 lines

  1.  
  2.  
  3. /-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-\
  4. !          Bell Telephone Info        !
  5. \-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-/
  6.  
  7.  
  8. ***************************************
  9.  
  10.    BRIDGING HEADS, RESIDENTIAL AND
  11.  BUSINESS MULTILINE DISTRIBUTION BOXES,
  12.     LINE AND TRUNK SPLITTERS, AND
  13.   OTHER BELL SYSTEM WIRE TERMINATIONS.
  14.  
  15.    - HOW TO USE, AND/OR ABUSE THEM -
  16.  
  17. (INCLUDING A TUTORIAL ON BASIC TELE-
  18.  PHONE EAVESDROPPING TECHNIQUES.)
  19.  
  20. ***************************************
  21.  
  22. WRITTEN BY :   PHUCKED
  23.          AGENT
  24.             04
  25.  
  26. ***************************************
  27.  
  28.     IN THIS ARTICLE, I WILL FIRST
  29. BESCRIBE THE TERMINATION, WIRING, AND
  30. TERMINAL HARDWARE MOST COMMONLY USED
  31. IN THE BELL SYSTEM, AND I WILL INCLUDE
  32. A SECTION ON METHODS OF USING THEM.
  33.  
  34. ***************************************
  35.  
  36. -------------
  37. LOCAL NETWORK
  38. -------------
  39.  
  40.     THE LOCAL TELEPHONE NETWORK
  41. BETWEEN THE CENTRAL OFFICE/EXCHANGE AND
  42. THE TELEPHONE SUBSCRIBERS CAN BE
  43. BREIFLY DESCRIBED AS FOLLOWS:
  44.     FROM THE CENTRAL OFFICE (OR
  45. LOCAL EXCHANGE) OF A CERTAIN PREFIX
  46. (ES), UNDERGROUND AREA FEEDER TRUNKS 
  47. GO TO EACH AREA THAT HAS THAT PREFIX.
  48. (USUALLY MORE THAN ONE PREFIX PER AREA)
  49. AT EVERY FEW STREETS OR TRACT AREAS,
  50. THE UNDERGROUND CABLES SURFACE. THEY
  51. THEN GO TO THE SECONDARY TERMINATION,
  52. (THE AERIAL TELEPHONE FEEDER CABLE)
  53. (OR BACK UNDERGROUND, DEPENDING ON THE
  54. AREA) AND THEN TO THE SUBSRIBERS HOUSE
  55. (OR IN THE CASE OF AN APARTMENT
  56. BUILDING OR MUTLILINE BUSINESS, TO
  57. A SPLITTER OR DISTRIBUTION BOX/PANEL).
  58.  
  59. ****************************************
  60. NOW THAT WE HAVE THE BASICS, I'LL TRY
  61. AND GO IN-DEPTH ON THE SUBJECT.
  62.  
  63. ------------------
  64. UNDERGROUND CABLES
  65. ------------------
  66.  
  67.     THESE ARE SOMETIMES INTER-
  68. OFFICE TRUNKS, BUT USUALLY IN A RESID-
  69. ENTIAL AREA THEY ARE FEEDER GROUPS THAT
  70. GO OTO BRIDGING HEADS OR DISTRIBUTION
  71. CASES. THE CABLES ARE ABOUT 2-3 INCHES
  72. THICK (VARIES), AND ARE EITHER IN A
  73. METAL OR PVC-TYPE PIPE (OR SIMILAR).
  74. RARELY (MAYBE NOT IN SOME REMOTE RURAL
  75. AREAS) ARE THE CABLES JUST 'ALONE' IN
  76. THE GROUND. INSTEAD, THEY ARE USUALLY
  77. IN AN UNDERGROUND CEMENT TUNNEL
  78. (RESEMBLES A SMALL SEWER OR STORMDRAIN)
  79. . THE MANHOLES ARE >HEAVY< AND WILL SAY
  80. 'BELL SYSTEM' ON THEM. THEY CAN BE OPEN
  81. ED WITH A 1/2 INCH WIDE CROWBAR (HOOK
  82. SIDE) INSERTED IN THE TOP RECTANGULAR
  83. HOLE. IF YOU GET IT OPEN, GO INSIDE!!
  84. THERE ARE LADDER RUNGS TO HELP YOU
  85. CLIMB DOWN. YOU WILL SEE THE CABLE
  86. PIPES ON THE WALL, WITH THE BLUE AND
  87. WHITE STRIPED ONE BEING THE INTER-
  88. OFFICE TRUNK GRP (AT LEAST IN MY AREA).
  89. THE OTHERS ARE LOCAL LINES, AND ARE
  90. USUALLY MARKED OR COLOR CODED. THERE
  91. IS ALMOST ALWAYS A POSTED COLOR CODE
  92. CHART ON THE WALL, NOT TO MENTION
  93. TELCO MANUALS DESCRIBING THE CABLES
  94. AND TERMINALS, SO I NEED NOT GET INTO
  95. DETAIL. AGAIN: >IF YOU CAN GET INTO A
  96. BELL MANHOLE, DO IT!, IT WILL PAY OFF
  97. <. ALSO, THERE IS USUALLY SOME KIND
  98. OF TEST EQUIPMENT, AND OFTEN BELL
  99. TEST SETS ARE LEFT IN THERE.
  100. SO GET YOUR CROWBARS!
  101.  
  102. ****************************************
  103. --------------
  104. BRIDGING HEADS - (WE MS2'S)
  105. --------------
  106.  
  107.     THE INNOCENT-LOOKING GRAYISH-
  108. GREEN BOXES.
  109.  WHEN IN GROUPS OF TWO OR THREE, THEY
  110. ARE FOR SECONDAY/TERTIARY TERMINATION
  111. AND ACCESS POINTS (BRIDGED ACCESS).
  112.  THESE ARE THE WESTERN ELECTRIC SAI
  113. 55 OR 22/E TERMINAL CASES. THEY HOLD 
  114. ON THE ORDER OF 900-1200 CABLE PAIRS.
  115. THIS IS USUALLY THE SECOND TERM. POSI
  116. TION ON THE LOCAL LOOP (AFTER THE MTF
  117. FRAME AT THE CO/ OR THE UNDERGROUND
  118. 'FTP' POSITION).
  119.  THESE CAN BE EITHER
  120. TRUNK BRIDGES OR BRIDGING FOR RESIDEN
  121. CES. THE AREA FEEDER BRIDGING HEADS
  122. ARE USUALLY LARGER, AND THEY HAVE THE
  123. 'WESTERN ELECTRIC' LOGO AT THE BOTTOM,
  124. WHEREAS THE NORMAL BRIDGING HEADS
  125. (WHICH MAY BE DIFFERENT IN SOME AREAS-
  126. DEPENDING ON THE COMPANY YOU ARE
  127. SERVED BY. GTE B.H'S LOOK SLIGHTLY
  128. DIFFERENT. ALSO, DO NOT BE FOOLED
  129. BY SPRINKLER BOXES!)
  130. CAN BE FOUND IN JUST ABOUT EVERY CITY.
  131.     TO OPEN A BRIDGING HEAD:
  132. IF IT IS LOCKED (AND YOU'RE FEELING
  133. DESTRUCTIVE), PUT A HAMMER OR CROWBAR
  134. (THE SAME ONE YOU USED ON THE MANHOLE
  135. ) IN THE SLOT ABOVE THE TOP HINGE OF
  136. THE RIGHT DOOR. PULL HARD, AND THE
  137. DORR WILL RIP OFF. VERY EFFECTIVE!
  138.    IF IT ISN'T LOCKED (AS USUAL),
  139. TAKE A 7/16 INCH HEX SOCKET AND
  140. WITH IT, TURN THE BOLT ABOUT 1/8 OF A
  141. TURN TO THE LEFT (YOU SHOULD HEAR
  142. A SPRING RELEASE INSIDE). HOLDING THE
  143. BOLT, TURN THE HANDLE ALL THE WAY TO
  144. THE RIGHT AND PULL OUT.
  145.     NOW INSIDE, FIRST CHECK FOR
  146. A TEST-SET (WHICH ARE OFTEN LEFT BY
  147. BELL EMPLOYEES). THERE SHOULD BE A
  148. PANEL OF CABLE PAIRS + SCREW TERMINALS
  149. (TYPE 45/47IB REGULAR BINDERS) . PUSH
  150. THE PANEL BACK ABOUT AN INCH OR SO,
  151. AND ROTATE THE TOP LATCH (ROUND WITH
  152. A FLAT SECTION) DOWNWARD. RELEASE THE
  153. PANEL AND IT WILL FALL ALL THE WAY 
  154. FORWARD. THERE IS USUALLY A LARGE AMO-
  155. UNT OF WIRE AND EXTRA TERMINALS.
  156. THE TEST-SETS ARE OFTEN HIDDEN HERE,
  157. SO DONT OVERLOOK IT (400 FOOT ROLLS OF
  158. #22 SOLID WIRE ARE OFTEN NEAR THE TOP
  159. IN THE BACK OF THE BOX. 'BORROW THEM')
  160. . ON THE RIGHT DOOR IS A METAL BOX OF
  161. INSULATORS, BINDERS, CLIPS, ETC.  TAKE
  162. A FEW (COMPLIMENTS OF BELL...). ON EACH
  163. DOOR IS A USEFUL ROUND METAL DEVICE.
  164. (SAYS 'INSERT GENTLY' OR 'CLAMP GENTLY
  165.  - DO NOT OVERTIGHTEN' ETC..) ON THE
  166. FRONT OF THE DISC, YOU SHOULD FIND TWO
  167. TERMINALS. THESE ARE FOR YOUR TEST SET.
  168. (IF YOU DONT HAVE ONE, DONT DEPAIR -
  169. I'LL SHOW YOU WAYS TO MAKE BASIC TEST
  170. SETS LATER IN THIS ARTICLE).
  171. HOOKING THE RING (-) WIRE TO THE
  172. 'R' TERMINAL; AND THE TIP (+) WIRE
  173. TO THE OTHER. (BY THE WAY, AN EASY WAY
  174. TO DETERMINE THE CORRECT POLARITY IS
  175. WITH A 1.5V LED. TAP IT TO THE TERM.
  176. PAIR, IF I DOESNT LIGHT, SWITCH THE
  177. POLES UNTIL IT DOES. WHEN IT LIGHTS,
  178. FIND THE LONGER OF THE TWO LED POLES.
  179. THIS ONE WILL BE ON THE TIP WIRE (+))
  180.  BEHIND THE DISC IS A COILED UP CORD.
  181. THIS SHOULD HAVE A SPECIALIZED CONNECT-
  182. OR. ITS VERY USEFUL, BECAUSE YOU
  183. DONT HAVE TO KEEP CONNECTING AND
  184. DISCONNECTING THE FONE (TEST SET)
  185. ITSELF, AND THE CLIP IS DESIGNED TO AID
  186. IN LOCATING THE PAIR AND ASSURING THE
  187. CORRECT POLARITY.
  188.     ON THE TERMINAL BOARD, THERE
  189. SHOULD BE ABOUT 20 PAIRS (RED/WHITE) 
  190. PER ROW PER SIDE. 
  191. HOOK THE CLIP TO ANY TERMINAL PAIR
  192. , AND YOU'RE SET! DIAL OUT IF YOU WANT,
  193. OR JUST LISTEN (IF SOMEONE'S ON THE
  194. LINE). LATER, I'LL SHOW YOU A WAY TO
  195. SET UP A TRUE 'TAP' THAT YOU CAN SET
  196. UP, AND WILL LET THE PERSON DIAL OUT
  197. ON HIS LINE AND RECEIVE CALLS AS
  198. NORMAL, AND YOU CAN LISTEN IN THE
  199. WHOLE TIME. MORE ABOUT THIS LATER...
  200.     ON MAJOR PREFIX-AREA BRIDGING
  201. HEADS ('SAI' FOR AREA C.O. FEEDER CABLE
  202. ) YOU CAN SEE TEMPORARY 'LOCAL LOOPS',
  203. WHICH ARE TWO CABLE PAIRS (CABLE
  204. PAIR = RING+TIP, A FONE LINE) THAT
  205. ARE DIRECTLY CONNECTED TO EACH OTHER
  206. ON THE TERMINAL BOARD. THESE 'CHEAP
  207. LOOPS' AS THEY ARE CALLED, DO NOT
  208. WORK NEARLY AS WELL AS THE EXISTING
  209. ONES SET UP IN THE SWITCHING HARDWARE
  210. AT THE EXCHANGE OFFICE. (TRY SCANNING
  211. YOUR PREFIXES' 00XX OR 99XX #'S.
  212. THE TONE SIDES WILL ANNOUNCE THEMSELVES
  213. WITH THE 1000 HZ LOOP TONE, AND THE
  214. HANG SIDE WILL GIVE NO RESPONSE. THE
  215. FIRST PERSON SHOULD DIAL THE 'HANG'
  216. SIDE, AND THE OTHER PERSON DIAL THE,
  217. TONE SIDE, AND THE TONE SHOULD STOP
  218. IF YOU HAVE GOT THE RIGHT LOOP).
  219.  THE LOOPS ARE USED IN FRAME TERMINATI
  220. ON AND IN SONIC/600 OHM TERM. TESTING
  221. AND LINE/CABLE/FEEDER LOCATION.
  222.     IF YOU WANT TO FIND THE NUMBER
  223. OF THE LINE THAT YOU'RE ON, YOU CAN
  224. EITHER TRY TO DECIPHER THE 'BRIDGING
  225. LOG' (OR WHATEVER), WHICH IS ON THE
  226. LEFT DOOR. IF THAT DOESNT WORK, YOU
  227. CAN USE THE FOLLWING:
  228.  
  229. ---
  230. ANI # (AUTOMATIC NUMBER INDENTICATION)
  231. ---
  232.     THIS IS A TELCO TEST NUMBER
  233. THAT REPORTS TO YOU THE NUMBER THAT
  234. YOURE CALLING FROM (IT'S THE SAME,
  235. CHOPPY 'BELL BITCH' VOICE THAT YOU
  236. GET WHEN YOU REACH A DISCONNECTED #)
  237. (PIP OR ONE OF THE 11X SERIES ANNOUNCE
  238. MENT FRAME MACHINES.)
  239.  
  240. FOR THE 213 NPA - DIAL 1223
  241.     213 NPA - (GTE AREAS) DIAL 114
  242.     408 NPA - DIAL 760
  243.     914 NPA - DIAL 990
  244.  
  245. THESE ARE EXTREMELY USEFUL WHEN MESSING
  246. WITH ANY KIND OF LINE TERMINALS, 
  247. FEEDER BOXES, ETC.
  248.  
  249.           ----------
  250.  
  251.     WHEN FINISHED, BE SURE TO CUT 
  252. OFF THE CONNECTOR AND TAKE IT WITH YOU
  253. (THEY ARE VERY HANDY), AND CLOSE/LATCH
  254. THE BOX TO AVOID SUSPICION.
  255.  
  256. ***************************************
  257.  
  258. ------
  259. "CANS" - AERIAL-MOUNTED (TELEPHONE POLE
  260. ------     TERMINAL) BRANCH FEEDER CABLE
  261.        SPLITTER.
  262.  
  263. BASICALLY, TWO TYPES:
  264.  
  265. 1> MS3A SERVICE AREA INTERFACE.
  266.   (LARGE, RECTANGULAR SILVER BOX AT
  267.     THE END OF EACH STREET.)
  268.  
  269. 2> SERIES 600 LOADING COIL, INCLUDES
  270.    THE MSX AERIAL DROP SPLITTER.
  271.   (BLACK, ROUND OR RECTANGULAR THING
  272.     AT EVERY TELEPHONE POLE.)
  273.  
  274.      --------
  275.  
  276. TYPE 1 -   THIS IS THE CASE THAT TAKES
  277. THE UNDERGROUND CABLE FROM THE BRIDGER
  278. AND RUNS IT TO THE AERIAL BRANCH FEEDER
  279. CABLE (THE LOWEST, LARGEST WIRE ON THE
  280. TELEPHONE POLE). THE BOX IS ALWAYS ON
  281. THE POLE NEAREST THE BRIGING HEAD,
  282. WHERE THE LINE COMES UP. LOOK FOR THE
  283. 'CALL BEFORE YOU DIG - UNDERGROUND
  284. CABLE' STICKERS..
  285.     THE CASE BOX IS HINGED, SO IF
  286. YOU WANT TO CLIMB THE POLE, YOU CAN
  287. OPEN IT WITH NO PROBLEMS. THESE USUALLY
  288. HAVE 2 ROWS OF TERMINAL SETS.
  289. (TOTAL APPROX. 200-600 PAIRS, DEPENDING
  290. ON THE AREA.) THESE ARE ALL THE CABLE
  291. PAIRS FOR YOUR STREET.
  292. . (ITS SIMILAR TO A MINIATURE BRIDGING
  293. HEAD). USE/ABUSE IT IN THE SAME MANNER
  294. AS WE DID BEFORE. (NOTE: ALL THE ACTIVE
  295. LINES CARRY FROM 15 TO 48 VDC, AND
  296. EVEN 90VAC (WHEN RINGING), SO BE
  297. CAREFUL - IT'S NOT GOING TO HURT YOU,
  298. BUT IT CAN SURPRISE YOU (AND IF
  299. YOU'RE HANGING BY ONE HAND FROM A TEL.
  300. POLE, IT >CAN< BE HARMFUL!))
  301.     OH, BY THE WAY, IF YOU USE
  302. ANI ON EVERY PAIR AND YOU FIND ONE
  303. THAT ISNT IN USE ON YOUR STREET, YOU
  304. CAN HOOK IT UP FOR YOURSELF (ALMOST).
  305. ALSO, YOU HAVE TO BE ABLE TO IMPER-
  306. SONATE A TELCO TECHNICIAN AND REPORT
  307. THE NUMBER AS 'NEW ACTIVE' (GIVING
  308. A FAKE NAME AND FAKE REPORT, ETC)
  309. I DONT RECOMMEND THIS AND IT PROBABLY
  310. WONT (ALMOST POSITIVELY WONT) WORK,
  311. BUT THIS IS BASICALLY WHAT TELCO
  312. LINEMEN DO).*
  313.  
  314.  
  315.       * THE USE OF THE 'TEST BOARD'
  316. (A 7D# FOR LINEMEN TESTS, OFTEN FOUND
  317. NXX-0003 OR NXX-0004) IS BEYOND THE
  318. SCOPE OF THIS ARTICLE, BUT WILL BE
  319. COVERED IN A FUTURE ARTICLE.
  320.  
  321.        ----
  322.  
  323. TYPE 2 - THIS IS THE SPLITTER BOX FOR
  324. THE AERIAL DROP WIRES FOR THE GROUP OF
  325. HOUSES AROUND THE POLE.
  326.  (USUALLY 4 OR 5 HOUSES). USE IT
  327. LIKE I MENTIONED BEFORE. THE TERMINALS
  328. (20 OR SO) WILL BE IN 2 HORIZONTAL
  329. ROWS OF SETS. THE EXTRA WIRES THAT ARE
  330. JUST 'HANGING THERE' ARE PROVISIONS
  331. FOR EXTRA LINES TO RESIDENCES (1 EXTRA
  332. LINE PER HOUSE, THATS WHY THE INSANE
  333. CHARGE FOR LINE #3). IF ITS THE BOX FOR
  334. YOUR HOUSE ALSO, HAVE FUN AND SWAP 
  335. LINES WITH YOUR NEIGHBOR! 'PIGGYBACK'
  336. THEM OR USE A CHEESEBOX FOR A LOOP-ARO
  337. UND, ETC.
  338. AGAIN, I DONT RECOMMEND THIS, AND ITS
  339. DIFFICULT TO DO IT CORRECTLY. (ALTHOUGH
  340. USEFUL)
  341.  
  342. ***************************************
  343. ---------------------------------------
  344.  
  345.  
  346. DOWNLOADED FROM P-80 SYSTEMS.
  347.  
  348.