home *** CD-ROM | disk | FTP | other *** search
/ Phoenix Rising BBS / phoenixrising.zip / phoenixrising / misc / pcpxfer.txt < prev    next >
Text File  |  1992-03-04  |  18KB  |  349 lines

  1.                              RECOMMENDATIONS REPORT
  2.                                    (Revised)
  3.  
  4.  
  5.                                       for
  6.  
  7.  
  8.  
  9.                           File Transfer Via PC Pursuit
  10.  
  11.  
  12.                                  (Oct 17, 1988)
  13.  
  14.                        Telenet Communication Corporation
  15.                         Field Operations HQ Tech Support
  16.                                 Reston, Virginia
  17.  
  18.  
  19.                                     CONTENTS
  20.  
  21.  
  22.  
  23.  
  24.                                                                  PAGE
  25.                                                                  ----
  26.  
  27.      1.0  Introduction...........................................  1
  28.  
  29.  
  30.      2.0  Recommendations........................................  2
  31.  
  32.  
  33.      3.0  File Transfer Procedures...............................  5
  34.  
  35.  
  36.  
  37.  
  38.      4.0  Summary................................................  6
  39.  
  40.  
  41.                             SECTION 1.: Introduction
  42.  
  43.  
  44.  
  45.      Because  of many customer complaints concerning PC Pursuit's inability
  46.      to allow file transfers, Field Operations  was  requested  to  provide
  47.      recommendations  for  file transfer via PC Pursuit. In compliance with
  48.      this request, this document provides the following:
  49.  
  50.      *  Recommendation on the best file transfer protocols to be used
  51.         with PC Pursuit.
  52.  
  53.      *  Recommendation on the hunt-confirm sequence and line parameters
  54.         which provide optimum performance of various protocols.
  55.  
  56.      *  The average transfer rates which can be expected using the
  57.         correct hunt-confirm sequence and optional parameter settings.
  58.  
  59.                           SECTION 2.: Recommendations
  60.  
  61.  
  62.  
  63.      This section outlines the most common  file  transfer  protocols  used
  64.      with  PC  Pursuit. The performance of the protocols in the direct con-
  65.      nect and PC Pursuit environments are also indicated.
  66.  
  67.      The following protocols were tested via the  Chicago  in-dial  to  the
  68.      Washington DC out-dial; the observations are summarized below.
  69.  
  70.  
  71.      XMODEM     XMODEM     XMODEM
  72.  
  73.      PC Pursuit XMODEM file transfers performed at an average throughput of
  74.      30%  when  the  correct  hunt-confirm  and terminal type was utilized.
  75.  
  76.  
  77.      XMODEM does not support flow control, therefore it is  suggested  that
  78.      the  "relaxed"  mode  be invoked if the user's communications software
  79.      permits this feature.
  80.  
  81.  
  82.      YMODEM     YMODEM     YMODEM
  83.  
  84.      The performance of YMODEM file transfers VIA PC Pursuit was  found  to
  85.      have  an  average  throughput of 56% when the correct hunt confirm and
  86.      terminal type is employed.  Although  YMODEM  does  not  support  flow
  87.      control, it uses large 1024 byte packets which the network PAD handles
  88.      quite  readily  under  normal conditions. As a result, YMODEM is rated
  89.      one of the faster protocols for file transfer via PC Pursuit.
  90.  
  91.  
  92.      WXMODEM     WXMODEM     WXMODEM
  93.  
  94.      WXMODEM file transfers utilizing the correct hunt-confirm and terminal
  95.      type performed well  with  an  average  transfer  rate  of  52%.  This
  96.      protocol  is  capable  of  handling  flow  control which enables it to
  97.      perform with better reliability in the PC Pursuit  environment.  Users
  98.      should  be  aware  that an early version of PROCOMM is known to have a
  99.      software problem which can affect  the  performance  of  WXMODEM  file
  100.      transfers.
  101.  
  102.  
  103.      KERMIT     KERMIT     KERMIT
  104.  
  105.      An  optimum  average  throughput  of  47%  was obtained by KERMIT file
  106.      transfers via PC Pursuit. The throughput was  optimized  by  modifying
  107.      the  packet size to 90 and adjusting the (host) window size to 16 (for
  108.      uploads). KERMIT software which supports the  sliding  window  feature
  109.      performs with optimum efficiency in the PC Pursuit environment.
  110.  
  111.      SEALINK     SEALINK     SEALINK
  112.  
  113.      SEALINK  file  transfers  via  PC Pursuit performed exceptionally well
  114.      with an average throughput of 74% with the  correct  hunt-confirm  and
  115.      terminal  type.  SEALINK  supports  flow  control and was specifically
  116.      designed to operate in the networking environment.
  117.  
  118.  
  119.      ZMODEM     ZMODEM     ZMODEM
  120.  
  121.      File transfers utilizing ZMODEM protocol via  PC  Pursuit  yielded  an
  122.      average  transfer  rate of 61%. ZMODEM performs well in the PC Pursuit
  123.      environment, however; the local configuration for ZMODEM  file  trans-
  124.      fers  proved  to  be cumbersome and difficult for the user. ZMODEM re-
  125.      quires several parameters to be set locally  and  on  the  local  pad.
  126.      These parameter settings can vary depending on the type of machine and
  127.      the  type  of  communications  software.  The X.3 PAD parameters which
  128.      should be employed are 1:0,4:10,5:1,7:8,12:1. In addition,  flow  con-
  129.      trol  (XON/XOFF)  should  be  enabled  at  the user PC. Because of the
  130.      difficulty in configuring ZMODEM for file transfer, it is  recommended
  131.      that only seasoned computer users attempt ZMODEM file transfers via PC
  132.      Pursuit.
  133.  
  134.      The  following  page  summarizes  file  transfer  performance  of  the
  135.      protocols tested. The protocols are  listed  in  order  (PCP  best  to
  136.      worst)  in  two categories: 1) performance via direct connect, 2) per-
  137.      formance via PC Pursuit utilizing the  recommended  hunt  confirm  and
  138.      parameter  settings  shown.  It  should  be  noted  that  the optional
  139.      parameters need only be employed if a user experiences  problems  with
  140.      transferring a particular file.
  141.  
  142.                       SECTION 3.: File Transfer Procedures
  143.  
  144.  
  145.      This  section  outlines  the step by step procedure for executing file
  146.      transfers via PC Pursuit. These procedures must be followed exactly to
  147.      achieve optimum transfer rates. The optional X.3 parameters  shown  on
  148.      the  previous  page  indicates  the  parameters which provide the best
  149.      transfer rate.
  150.  
  151.      STEP 1.:    Set PC communications software to 8 bits, no parity,
  152.                  1 stop bit, full duplex. Depending on the type of protocol
  153.                  to be used, disable or enable local (XON/XOFF) flow
  154.                  control.
  155.  
  156.      STEP 2.:    Dial local rotary with the communications software
  157.                  set at the desired speed.
  158.  
  159.      STEP 3.:    Upon answer use the correct hunt confirm sequence:
  160.                      At 300/1200bps use - <CR D CR>
  161.                      At 2400bps         - <@ D CR>
  162.                      NOTE: "D" MUST BE UPPER CASE.
  163.  
  164.      STEP 4.:    At prompt "TERMINAL = " enter  <D1> and return.
  165.  
  166.      STEP 5.:    At the "@" prompt enter the destination mnemonic,
  167.                  out-dial speed, ID and password.  It is important
  168.                  that out-dial speed matches in-dial speed.
  169.                  DO NOT MIX IN-DIAL AND OUT-DIAL SPEEDS.
  170.  
  171.      STEP 6.:    If pad X.3 parameters are to be changed, do so
  172.                  at this point by entering <@ CR>. Set parameters as
  173.                  prescribed. Return to out-dial port by entering
  174.                  <CONT>.
  175.  
  176.                  An example of the proper syntax for modifying X.3 PAD
  177.                  parameters would be "SET 7:8,1:0." To display the current
  178.  
  179.  
  180.                  PAD parameter settings, the user should enter "PAR?."
  181.  
  182.                  These are only two of many user commands available. Many
  183.                  of the user commands are clearly defined in the Telenet
  184.                  document "How to Use Telenet's Asynchronous Dial Service."
  185.  
  186.      STEP 7.:    Upon connecting to the destination pad, insure
  187.                  communication with the out-dial modem by entering <ATZ>.
  188.                  The destination modem will respond with "OK".
  189.  
  190.      STEP 8.:    Enter <ATD> and the local number you wish to dial.
  191.  
  192.      STEP 9.:    Queue host file transfer and start file transfer.
  193.  
  194.      Please note that these are the basic steps needed to achieve  success-
  195.      ful  file  transfers.  Since  communications  software  may  vary from
  196.      package to package, additional steps may be  needed  to  initiate  the
  197.      start of the file transfer at the user software level.
  198.                              SECTION 4.: Summary
  199.  
  200.      Extensive testing has resulted in identifying the expected performance
  201.      of  six  file  transfer  protocols  when  used  with PC Pursuit. These
  202.      protocols have been  determined  to  perform  satisfactorily  with  PC
  203.      Pursuit  when  the  correct hunt-confirm, terminal type and parameters
  204.      are employed.
  205.  
  206.      It is the recommendation of Field Operations  that  customers  be  in-
  207.      formed of the correct logon procedures and the protocols which provide
  208.      the  most  reliable  file transfers. Customers should also be reminded
  209.      that PCP users can expect a small degree of  network  delay  which  is
  210.      considered  a  common  characteristic  of packet switched networks. In
  211.      addition, users should also be informed that poor quality voice  grade
  212.      telephone lines can adversely affect file transfer sessions.
  213.  
  214.  
  215.  
  216.      Field  Operations is one of many Telenet groups dedicated to providing
  217.      customers with complete support for PC Pursuit. Field Operations  will
  218.      offer assistance with file transfer problems providing the customer is
  219.      willing  to  release a copy of the problem software as well as provide
  220.      the pertinent information necessary to resolve the problem.
  221.  
  222.      Because  problems  can  vary in nature,  the  information  required to
  223.      resolve problems can differ  from one problem to the next.  But at the
  224.      very least, the following information will be required:
  225.  
  226.          * Type of communication software
  227.          * Type of PC, make, model
  228.          * Type of modem
  229.          * Call origin
  230.          * Call destination
  231.          * Speed in
  232.          * Speed out
  233.          * Type of session
  234.          * Time of failure
  235.          * Date of Failure
  236.          * Point of failure in session
  237.          * Out-dial number
  238.          * Network Address (if possible)
  239.          * Copy of PC Software (in some cases)
  240.  
  241.      Additional  information  may be required  depending  on the  nature of
  242.      the problem.
  243.  
  244.                                  FILE TRANSFER
  245.                              PERFORMANCE STATISTICS
  246.                       PERFORMANCE STATISTICS DIRECT CONNECT
  247.  
  248.  
  249.   General Communication Parameters = 8 bits
  250.                                      1 stop bit
  251.                                      N no parity
  252.   Terminal Type = D1
  253.  
  254.  
  255.   |          PERFORMANCE STATISTICS DIRECT CONNECT       |
  256.   |                                                      |
  257.   |                                                      |
  258.   |                                                XFR   |
  259.   | PROTOCOL    SPEED  SECONDS      CPS       BPS  RATE  |
  260.   |======================================================|
  261.   |                                                      |
  262.   | SEALINK UP   1200   ***517    87.15    871.49   73%  |
  263.   | SEALINK UP   2400   ***270   166.87   1668.74   70%  |
  264.   | SEALINK DN   1200   ***428   105.27   1052.71   88%  |
  265.   | SEALINK DN   2400   ***230   195.90   1958.96   82%  |
  266.   |                                                      |
  267.   | ZMODEM UP    1200   ***408   110.43   1104.31   92%  |
  268.   | ZMODEM UP    2400   ***201   224.16   2241.59   93%  |
  269.   | ZMODEM DN    1200   ***391   115.23   1152.33   96%  |
  270.   | ZMODEM DN    2400   ***195   231.06   2310.56   96%  |
  271.   |                                                      |
  272.   | YMODEM UP    1200    **259   102.80   1027.95   86%  |
  273.   | YMODEM UP    2400    **126   211.30   2113.02   88%  |
  274.   | YMODEM DN    1200    **244   109.11   1091.15   91%  |
  275.   | YMODEM DN    2400    **130   204.80   2048.00   85%  |
  276.   |                                                      |
  277.   | WXMODEM UP   1200    **277    96.12    961.16   80%  |
  278.   | WXMODEM UP   2400    **159   167.45   1674.47   70%  |
  279.   | WXMODEM DN   1200    **405    65.74    657.38   55%  |
  280.   | WXMODEM DN   2400    **131   203.24   2032.37   85%  |
  281.   |                                                      |
  282.   | KERMIT UP    1200    **356    74.79    747.87   62%  |
  283.   | KERMIT UP    2400    **211   126.18   1261.80   53%  |
  284.   | KERMIT DN    1200    **322    82.68    826.83   69%  |
  285.   | KERMIT DN    2400    **178   149.57   1495.73   62%  |
  286.   |                                                      |
  287.   | XMODEM UP    1200    **259   102.80   1027.95   86%  |
  288.   | XMODEM UP    2400    **140   190.17   1901.71   79%  |
  289.   | XMODEM DN    1200    **268    99.34    993.43   83%  |
  290.   | XMODEM DN    2400    **146   182.36   1823.56   76%  |
  291.    ======================================================
  292.  
  293.        **File size = 26624    ***File size = 45056
  294.  
  295.                                  FILE TRANSFER
  296.                              PERFORMANCE STATISTICS
  297.                          PERFORMANCE STATISTICS VIA PCP
  298.  
  299.  
  300.   General Communication Parameters = 8 bits
  301.                                      1 stop bit
  302.                                      N no parity
  303.   Terminal Type = D1
  304.  
  305.  
  306.  
  307.  |                                               PERFORMANCE STATISTICS VIA PCP                                               |
  308.  |                                                                                                                            |  
  309.  |                                                     HUNT                ITI                                                |
  310.  |                                                                                                                            |
  311.  |                                                XFR  CONFIRM   FLOW      X.3 PAD                                            |
  312.  | PROTOCOL    SPEED  SECONDS     CPS      BPS   RATE  SEQUENCE  CONTROL   PARAMETERS               NOTES                     |
  313.  |================================================================================================ ===========================|
  314.  |                                                                                                                            |
  315.  | SEALINK UP   1200   ***561    80.31   803.14   67%  CR D CR   XON/XOFF  *7:8,1:0                End-to-End flow control on |
  316.  | SEALINK UP   2400   ***300   150.19  1501.87   63%   @ D CR   XON/XOFF  *7:8,1:0                End-to-End flow control on |
  317.  | SEALINK DN   1200   ***447   100.80  1007.96   84%  CR D CR   XON/XOFF  *7:8,1:0                End-to-End flow control on |
  318.  | SEALINK DN   2400   ***231   195.05  1950.48   81%   @ D CR   XON/XOFF  *7:8,1:0                End-to-End flow control on |
  319.  |                                                                                                                            |
  320.  | ZMODEM UP    1200   ***622    72.44   724.37   60%  CR D CR   XON/XOFF  *1:0,4:10,5:1,7:8,12:1  End-to-End flow control on |
  321.  | ZMODEM UP    2400   ***363   124.12  1241.21   52%   @ D CR   XON/XOFF  *1:0,4:10,5:1,7:8,12:1  End-to-End flow control on |
  322.  | ZMODEM DN    1200   ***573    78.63   786.32   66%  CR D CR   XON/XOFF   1:0,4:10,5:1,7:8,12:1  End-to-End flow control on |
  323.  | ZMODEM DN    2400   ***288   156.44  1564.44   65%   @ D CR   XON/XOFF   1:0,4:10,5:1,7:8,12:1  End-to-End flow control on |
  324.  |                                                                                                                            |
  325.  | YMODEM UP    1200    **443    60.10   600.99   50%  CR D CR      NONE   *7:8,1:0                                           |
  326.  | YMODEM UP    2400    **200   133.12  1331.20   55%   @ D CR      NONE   *7:8,1:0                                           |
  327.  | YMODEM DN    1200    **335    79.47   794.75   66%  CR D CR      NONE   *7:8,1:0                                           |
  328.  | YMODEM DN    2400    **211   126.18  1261.80   53%   @ D CR      NONE   *7:8,1:0                                           |
  329.  |                                                                                                                            |
  330.  | WXMODEM UP   1200    **480    55.47   554.67   46%  CR D CR   XON/XOFF  *7:8,1:0                End-to-End flow control on |
  331.  | WXMODEM UP   2400    **258   103.19  1031.94   43%   @ D CR   XON/XOFF  *7:8,1:0                End-to-End flow control on |
  332.  | WXMODEM DN   1200    **363    73.34   733.44   61%  CR D CR   XON/XOFF  *7:8,1:0                End-to-End flow control on |
  333.  | WXMODEM DN   2400    **193   137.95  1379.48   57%   @ D CR   XON/XOFF  *7:8,1:0                End-to-End flow control on |
  334.  |                                                                                                                            |
  335.  | KERMIT UP    1200    **597    44.60   445.96   37%  CR D CR   XON/XOFF  *7:8,1:0,5:1,12:1                                  |
  336.  | KERMIT UP    2400    **298    89.34   893.42   37%   @ D CR   XON/XOFF  *7:8,1:0,5:1,12:1                                  |
  337.  | KERMIT DN    1200    **389    68.44   684.42   57%  CR D CR   XON/XOFF  *7:8,1:0,5:1,12:1                                  |
  338.  | KERMIT DN    2400    **196   135.84  1358.37   57%   @ D CR   XON/XOFF  *7:8,1:0,5:1,12:1                                  |
  339.  |                                                                                                                            |
  340.  | XMODEM UP    1200    **734   36.27   362.72    30%  CR D CR      NONE   *7:8,1:0                                           |
  341.  | XMODEM UP    2400    **424   62.79   627.92    26%   @ D CR      NONE   *7:8,1:0                                           |
  342.  | XMODEM DN    1200    **638   41.73   417.30    35%  CR D CR      NONE   *7:8,1:0                                           |
  343.  | XMODEM DN    2400    **373   71.38   713.78    30%   @ D CR      NONE   *7:8,1:0                                           |
  344.    =============================================================================================== ============================
  345.  
  346.   * Optional PAD parameters which optimize performance    **File size = 26624    ***File size = 45 56
  347.  
  348. Downloaded From P-80 Systems 304-744-2253
  349.