TEST UPDATE INFORMATION
-----------------------
02/03/94 16:55 PCBOARD.EXE
--------------------------
- Disabled the use of "A", for (A)rcView, at the flagging "more?" prompt. This
was long ago replaced with (V)iew, but the "A" has been kept as a synonym for
a number of years.
- Modified the (P)rotocol selection, just before the file transfer begins, so
that it will not allow you to select ASCII if you have specified a known
"binary" type of file to be transferred.
- Made a fix in the way alias names are handled in the message base when
selecting messages to read.
- Modified the SELECT command to allow CTRL-X to abort out during the
selection process.
02/03/94 16:14 PCBSETUP.EXE
---------------------------
- Added the forward slash (/) as a valid character in conference names.
01/31/94 17:57 PCBOARD.EXE
--------------------------
- Found that the ARNET OS/2 Device Driver required a short delay in between
opening the comm port and testing to see if Carrier Detect (CD) was up.
Without the delay, the driver reporting it as being down which affected
returning from a door. Fixed by inserting a delay after opening the port.
- Modified the %ENV% environment variable support (in display files) so that
more than one variable can be included in the path. In other words, the
following is now valid: %DRIVE%%DIR%file.txt
- If you used "CHAT G" from an "End of Message Command" prompt, upon return
PCBoard could go into a non-stop display of messages. Fixed.
- Made a change to increase the "abortability" of file scans. If no files
were being found you had to have your timing just about right on hitting a
ctrl-x when the directory description was being displayed in order to abort.
Now it should abort with less effort.
- Modified upload processing so that, after running pcbtest.bat, if the UPDESC
file does not exist, PCBoard won't complain about its non-existence.
- Modified /CID processing to convert underscores to spaces.
PPL
---
- Minor modification to the MOUSEREG statement in PPL for better RIP
compatibility.
01/31/94 16:01 PCBFILER.EXE
---------------------------
- If, after saving a DIR file, you answered "Y" to this question:
Check for duplicate files in each text DIR listing processed?
Then during the processing of the DIR files, PCBFiler could lose or mess up
the secondary description lines. Fixed.