  1. AST RESEARCH TECHNICAL BULLETIN TB-0050                  10-24-84
  2.  
  3.  
  4.              DIAGNOSTIC TESTING OF THE PARALLEL PORT
  5.  
  6.  
  7. In order to perform a thorough test of AST's parallel port  (when
  8. running IBM diagnostics) you need to provide the incoming signals
  9. to  the  port.   This may be accomplished by constructing a  wrap
  10. plug  and  installing  it on the  parallel  port  connector.   To
  11. construct  a wrap plug use a DB25 male  connector.   Utilizing  a
  12. minimum of 30AWG wire make connections as listed below:
  13.  
  14.           1  >  13
  15.  
  16.           2  >  15
  17.  
  18.          10  >  16
  19.  
  20.          11  >  17
  21.  
  22.          12  >  14