home *** CD-ROM | disk | FTP | other *** search
/ Current Shareware 1994 January / SHAR194.ISO / menuing / eddy7d.zip / EDDY.DOC < prev    next >
Text File  |  1993-08-30  |  287KB  |  5,876 lines

  1.    EDDY v.7d User's Manual              Copyright (C) 1987-93 by John Scofield
  2.  
  3.  
  4.  
  5.    ===========================================================================
  6.                                     DEDICATION
  7.  
  8.     EDDY is dedicated to the memory of Dean W. Anschultz, a good friend and a
  9.    GOOD man, in every sense of the word. His ideas, encouragement, and uncanny
  10.        abilities as beta-tester have been the major driving forces for the
  11.                  continuing development and improvement of EDDY.
  12.  
  13.                           Dean, you are missed.  R.I.P.
  14.    ===========================================================================
  15.  
  16.  
  17.  
  18.  
  19.  
  20.  
  21.  
  22.  
  23.  
  24.  
  25.  
  26.  
  27.  
  28.                         |-------------------------------|
  29.                         |           EDDY (TM)           |
  30.                         |   File and Directory Editor   |
  31.                         |    Copyright (C) 1987-1993    |
  32.                         |       by  John Scofield       |
  33.                         |      All rights reserved      |
  34.                         |    CompuServe:  70162,2357    |
  35.                         |-------------------------------|
  36.  
  37.  
  38.  
  39.  
  40.  
  41.  
  42.  
  43.  
  44.  
  45.  
  46.                               _______
  47.                          ____|__     |               (R)
  48.                       --|       |    |-------------------
  49.                         |   ____|__  |  Association of
  50.                         |  |       |_|  Shareware
  51.                         |__|   o   |    Professionals
  52.                       -----|   |   |---------------------
  53.                            |___|___|    MEMBER
  54.   EDDY v.7d User's Manual              Copyright (C) 1987-93 by John Scofield
  55.  
  56.  
  57.  
  58.  
  59.  
  60.  
  61.  
  62.  
  63.  
  64.  
  65.  
  66.  
  67.  
  68.  
  69.                        DISCLAIMER - PLEASE READ CAREFULLY!
  70.    ===========================================================================
  71.       BY USING THIS PROGRAM, EDDY ("the software"), YOU ACCEPT THESE TERMS:
  72.  
  73.         THE  SOFTWARE  AND  ITS  ASSOCIATED  DOCUMENTATION  ARE SUPPLIED
  74.         "AS-IS", WITHOUT ANY WARRANTY OF ANY KIND.  THE AUTHOR EXPRESSLY
  75.         AND SPECIFICALLY  DISCLAIMS ALL  REPRESENTATIONS AND  WARRANTIES
  76.         RELATING TO THE SOFTWARE, WHETHER EXPRESS OR IMPLIED, INCLUDING,
  77.         BUT  NOT   LIMITED  TO,  ANY  IMPLIED   WARRANTIES  OF  QUALITY,
  78.         PERFORMANCE,   MERCHANTABILITY   OR  FITNESS  FOR  A  PARTICULAR
  79.         PURPOSE.   NEITHER  THE  AUTHOR  NOR  ANYONE  ELSE WHO  HAS BEEN
  80.         INVOLVED IN THE DELIVERY OF THE SOFTWARE SHALL BE LIABLE FOR ANY
  81.         DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL  DAMAGES
  82.         ARISING OUT OF THE USE OR  INABILITY TO USE THE  SOFTWARE OR FOR
  83.         ANY LOSS  OR  DAMAGE  OF ANY  NATURE  CAUSED  TO  ANY  PERSON OR
  84.         PROPERTY  AS A RESULT  OF THE USE OF THE  SOFTWARE,  EVEN IF THE
  85.         AUTHOR HAS BEEN SPECIFICALLY  ADVISED OF THE POSSIBILITY OF SUCH
  86.         DAMAGES OR CLAIMS.  THE AUTHOR IS NOT RESPONSIBLE FOR ANY COSTS,
  87.         INCLUDING,  BUT NOT  LIMITED TO,  THOSE INCURRED  AS A RESULT OF
  88.         LOST PROFITS  OR REVENUE,  LOSS OF USE OF THE SOFTWARE,  LOSS OF
  89.         DATA,  THE  COSTS  OF  RECOVERING  ANY  SOFTWARE  OR  DATA,   OR
  90.         THIRD-PARTY  CLAIMS.  IN NO EVENT  SHALL THE  AUTHOR'S LIABILITY
  91.         FOR ANY DAMAGES TO YOU OR  ANY OTHER PARTY EVER EXCEED THE PRICE
  92.         PAID FOR THE LICENSE TO USE THE SOFTWARE, REGARDLESS OF THE FORM
  93.         OF THE CLAIM.
  94.  
  95.    ===========================================================================
  96.  
  97.                               USE AT YOUR OWN RISK!
  98.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page   i
  99.  
  100.                              TABLE OF CONTENTS
  101.  
  102.     1. What Does EDDY Do? ..............................................  1
  103.        1.1 EDDY is Ready if You Are ....................................  1
  104.        1.2 Installation ................................................  2
  105.        1.3 EDDY's Display ..............................................  2
  106.            1.3.1 What Country Are You From? ............................  3
  107.            1.3.2 Printing ..............................................  3
  108.        1.4 What You See Is What You Edit (WYSIWYE?) ....................  3
  109.            1.4.1 Working and Target Directory ..........................  3
  110.            1.4.2 Sequence & Sorting ....................................  4
  111.            1.4.3 Number of Files .......................................  5
  112.            1.4.4 File Sizes & Disk Capacity ............................  5
  113.            1.4.5 Directory Sizes .......................................  6
  114.  
  115.     2. Telling EDDY What To Do .........................................  7
  116.        2.1 Moving Around ...............................................  7
  117.            2.1.1 Using the Keyboard ....................................  7
  118.            2.1.2 Using a Mouse .........................................  8
  119.                  a. Changing the Button Command - [Alt+m] ..............  8
  120.                  b. If You're Left-handed ..............................  8
  121.                  c. Mouse Sensitivity - [Alt+Shift+m] ..................  9
  122.            2.1.3 Using the Scroll Bar ..................................  9
  123.        2.2 Commands .................................................... 10
  124.            2.2.1 Hot Keys .............................................. 10
  125.            2.2.2 Pull-Down Menus - [Alt+F1] ............................ 11
  126.            2.2.3 Dialog Boxes .......................................... 13
  127.            2.2.4 List Boxes ............................................ 14
  128.        2.3 Options - [Alt+o] ........................................... 15
  129.  
  130.     3. EDDY's DOS Command Line ......................................... 17
  131.        3.1 Path Specifications ......................................... 17
  132.        3.2 Options on the Command Line ................................. 18
  133.        3.3 Other Command Line Parameters ............................... 19
  134.  
  135.     4. Editing Directory Entries ....................................... 19
  136.        4.1 Selecting a File or Directory (Speed Search) ................ 19
  137.        4.2 Renaming Files .............................................. 20
  138.        4.3 Changing Date and Time ...................................... 21
  139.        4.4 Changing File Attributes .................................... 21
  140.  
  141.     5. Moving to a New Directory ....................................... 22
  142.        5.1 Dialog Boxes or Tree Diagrams - Your Choice ................. 22
  143.            5.1.1 How to Choose ......................................... 22
  144.            5.1.2 Performance Considerations ............................ 23
  145.                  a. Memory is Always Up-to-Date ........................ 23
  146.                  b. Save a Tree - [F5] ................................. 24
  147.        5.2 Directory Selection via Dialog Box .......................... 24
  148.            5.2.1 Working Directory Dialog Box - [Alt+Shift+w]/[Alt+w] .. 25
  149.            5.2.2 Target Directory Dialog Box - [Alt+Shift+t]/[Alt+t] ... 26
  150.        5.3 Directory Selection from Tree Diagram ....................... 27
  151.            5.3.1 Tree Display Format ................................... 27
  152.            5.3.2 Moving the Tree Highlight (Speed Search) .............. 27
  153.  
  154.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  ii
  155.  
  156.  
  157.  
  158.            5.3.3 Moving to a New Drive - [^letter] / [^\] .............. 28
  159.            5.3.4 Working Directory Tree - [Alt+w] ...................... 28
  160.            5.3.5 Target Directory Tree - [Alt+t] ....................... 28
  161.        5.4 Exchange Working & Target Directories - [Alt+x] ............. 29
  162.        5.5 Directory Recall - [Shift+F10], [Shift+^F10] ................ 29
  163.        5.6 Where's That File? - Option /W and [^w] ..................... 29
  164.        5.7 Working With "SUBST"ed Directories .......................... 30
  165.            5.7.1 From the Command Line ................................. 30
  166.            5.7.2 Interactively ......................................... 30
  167.  
  168.     6. HELP When You Need It - [F1] .................................... 31
  169.        6.1 HELP for Warnings and Other Messages ........................ 31
  170.  
  171.     7. UNDO Command - [F2], [^F2] ...................................... 31
  172.        7.1 Partial UNDO ................................................ 31
  173.  
  174.     8. LOOK Command - [F3], [^F3] ...................................... 32
  175.        8.1 LOOK at Subdirectory ........................................ 32
  176.        8.2 LOOK at File Contents (in Working Directory) ................ 34
  177.            8.2.1 Commands in LOOK Mode ................................. 34
  178.                a. Hex/ASCII Format Control - [Tab] / [Shift+Tab] ....... 34
  179.                b. Printing a File - [Alt+p] ............................ 34
  180.                c. EGA/VGA Screen Control - [e] ......................... 34
  181.            8.2.2 ASCII Format Display .................................. 35
  182.            8.2.3 ASCII Format Commands ................................. 36
  183.                a. TAB Expansion - [0] thru [8] / [Alt+0] thru [Alt+8] .. 36
  184.                b. Bit-stripping - [b] / [Alt+b] ........................ 36
  185.                c. Ruler Line Display - [r] / [u] / [d] ................. 37
  186.                d. Jump to New Line - [j] ............................... 37
  187.                e. Line Wrapping - [l] / [Alt+l] ........................ 37
  188.            8.2.4 Hex Format Display .................................... 38
  189.            8.2.5 Hex Format Commands ................................... 39
  190.                a. Printability - [p] ................................... 39
  191.                b. Bit-stripping - [b] / [Alt+b] ........................ 39
  192.                c. Jump to New File Offset - [j] ........................ 39
  193.                d. Word-oriented Display - [w], [W] ..................... 40
  194.            8.2.6 LOOK Mode With a Mouse ................................ 40
  195.        8.3 LOOK at File Contents (in Target Directory) - [Alt+F3] ...... 40
  196.        8.4 Compare Directory Entries - [Shift+F3], [Shift+^F3] ......... 41
  197.        8.5 Compare Files - [Alt+Shift+F3] .............................. 41
  198.        8.6 LOOK at RAM (or ROM, or ???) ................................ 42
  199.        8.7 LOOK at Entire Disk ......................................... 42
  200.  
  201.     9. PATCH Command - [F4], [^F4] ..................................... 43
  202.        9.1 Changing a File's Length .................................... 44
  203.            9.1.1 Appending Bytes to a File - [Alt+z] ................... 44
  204.            9.1.2 Deleting Bytes From a File - [Alt+y]/[Alt+a]/[Alt+b]... 44
  205.        9.2 Updating in PATCH - [Enter] or [^Enter] ..................... 44
  206.        9.3 PATCHing RAM ................................................ 44
  207.        9.4 PATCHing Disks by Sector .................................... 45
  208.  
  209.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page iii
  210.  
  211.  
  212.  
  213.    10. Synchronization Controls - [Alt+c] .............................. 46
  214.        10.1 Controls for COPY/MOVE ..................................... 46
  215.        10.2 Tagging Confirmation Process ............................... 47
  216.        10.3 Synchronizing/Reconciling Directories ...................... 48
  217.        10.4 Controls for DELETE/DESTROY ................................ 48
  218.  
  219.    11. COPY Command - [F5], [^F5] ...................................... 49
  220.        11.1 COPY a File - [F5] ......................................... 50
  221.        11.2 COPY Multiple Files - [^F5] ................................ 50
  222.        11.3 COPYing Files With Disk Errors ............................. 50
  223.        11.4 COPY a Directory - [F5] .................................... 51
  224.        11.5 CONVERT File Data .......................................... 52
  225.             11.5.1 TABs to Spaces - [Alt+0] thru [Alt+8] ............... 52
  226.             11.5.2 Bit-stripping - [Alt+b] ............................. 52
  227.  
  228.    12. MOVE Command - [F6], [^F6] ...................................... 53
  229.        12.1 MOVE a File - [F6] ......................................... 53
  230.        12.2 MOVE Multiple Files - [^F6] ................................ 54
  231.        12.3 MOVE a Directory - [F6] .................................... 54
  232.        12.4 Fast Directory Move ........................................ 55
  233.             12.4.1 What Makes It Fast? ................................. 55
  234.             12.4.2 Had a Problem? Don't Panic! ......................... 56
  235.  
  236.    13. DELETE Command - [F7], [^F7] .................................... 57
  237.        13.1 Deleting Subdirectories .................................... 57
  238.        13.2 Logical DELETE (Ignore) - [Alt+F7], [Alt+^F7] .............. 58
  239.        13.3 DESTROY - [Shift+F7], [Shift+^F7] .......................... 58
  240.  
  241.    14. DOS Gateway ..................................................... 59
  242.        14.1 The DOS Shell - [F9] ....................................... 59
  243.        14.2 Point-n-Shoot .............................................. 60
  244.             14.2.1 Execute .COM, .EXE or .BAT File - [Alt+F9] .......... 60
  245.             14.2.2 Execute Default Command - [Shift+F8] ................ 60
  246.             14.2.3 Point-n-Shoot with EDDY.USE - [Shift+F9] ............ 61
  247.             14.2.4 Point-n-Shoot Again - [Shift+^F8] / [Shift+^F9] ..... 62
  248.  
  249.    15. QUIT Command - [F10], [Esc] ..................................... 64
  250.        15.1 Directory Recall - [Shift+F10], [Shift+^F10] ............... 64
  251.        15.2 Exit to Directory - [Alt+F10] .............................. 64
  252.        15.3 EGA and VGA Display Control - [^F10] ....................... 64
  253.  
  254.    16. FIND and/or REPLACE String in File, Disk or RAM ................. 65
  255.        16.1 Entering New FIND Strings - [Alt+f] ........................ 66
  256.        16.2 Global Match Character - [Alt+g] ........................... 67
  257.        16.3 "Don't Match" Attribute - [Alt+k] .......................... 67
  258.        16.4 FIND "Any Text" ............................................ 68
  259.        16.5 Search for FIND String in All Files - [^f] ................. 69
  260.        16.6 FIND and REPLACE - [Alt+r] ................................. 69
  261.  
  262.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page iv
  263.  
  264.  
  265.  
  266.    17. File Selection by Filtering ..................................... 70
  267.        17.1 Filtering by Attribute ..................................... 70
  268.             17.1.1 Attribute Selection from the Command Line ........... 70
  269.             17.1.2 Attribute Selection in EDDY - [Alt+a] ............... 71
  270.        17.2 Filtering by Timestamp...................................... 71
  271.             17.2.1 Timestamp Selection from the Command Line ........... 71
  272.             17.2.2 Timestamp Selection in EDDY - [Alt+q] ............... 72
  273.  
  274.    18. Playing With RAM ................................................ 73
  275.  
  276.    19. Volume Identifiers .............................................. 74
  277.        19.1 Volume Labels - [Alt+v] .................................... 74
  278.        19.2 Volume Serial Numbers - [^v] ............................... 74
  279.  
  280.    20. Batch Operations ................................................ 74
  281.        20.1 Commands Available ......................................... 74
  282.        20.2 Processing Sequence ........................................ 74
  283.        20.3 Synchronization Controls ................................... 75
  284.        20.4 ERRORLEVEL ................................................. 75
  285.  
  286.    21. Disk Jockey's Delight  (format-level disk functions) ............ 76
  287.        21.1 "Compressed" or "Extended" Drives (DoubleSpace, etc.) .....  76
  288.        21.2 LOOK at Entire Disk - [F3] ................................. 77
  289.             21.2.1 Jumping Around ...................................... 78
  290.                  a. Jump to Sector - [j] ............................... 78
  291.                  b. Jump to Cluster - [Alt+j] .......................... 78
  292.                  c. Jump to Working Directory - [Alt+w] ................ 78
  293.                  d. Jump to Target Directory - [Alt+t] ................. 78
  294.                  e. Jump to Starting Cluster - [Alt+s] ................. 78
  295.                  f. Jump to Next Cluster - [Alt+n] ..................... 79
  296.                  g. Jump to Unallocated Cluster - [Alt+u] .............. 79
  297.             21.2.2 Displaying Directory Entries - [Alt+d] .............. 80
  298.        21.3 PATCH Anything on a Disk - [F4] ............................ 81
  299.        21.4 That's Too Dangerous! ...................................... 81
  300.        21.5 FIND Strings Anywhere on a Disk - [Alt+f] .................. 81
  301.    22. Working With Disk-Image Data .................................... 82
  302.        22.1 COPY Disk Image - [Shift+F5] ............................... 82
  303.             a. Upload/Download Entire Disks ............................ 82
  304.             b. Make Multiple Copies Quickly ............................ 83
  305.             c. Reduce Disks Needed for Backup .......................... 83
  306.             d. No-Hassle Hard Disk Backup .............................. 83
  307.        22.2 Disk-Image Restore - [Shift+F5] ............................ 84
  308.        22.3 COPY Selected Disk Areas ................................... 84
  309.             22.3.1 Mark Sectors (System Area) - [m] .................... 85
  310.             22.3.2 Mark Clusters (Data Area) - [m] ..................... 85
  311.             22.3.3 Jump to Marked Area - [Alt+m] ....................... 85
  312.             22.3.4 COPY Marked Area - [Enter] .......................... 86
  313.        22.4 Data Recovery .............................................. 87
  314.  
  315.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page v
  316.  
  317.  
  318.  
  319.    23. Directory Optimization .......................................... 89
  320.        23.1 Sorting a Directory ........................................ 90
  321.        23.2 Shuffling a Directory - [Alt+F6] ........................... 91
  322.        23.3 Packing a Directory ........................................ 91
  323.        23.4 Had a Problem? Don't Panic! ................................ 92
  324.  
  325.    24. UPDATE Mode - [Enter], [^Enter] ................................. 93
  326.        24.1 Applying Changes ........................................... 93
  327.        24.2 Print a Record of Your Changes - [Alt+p] ................... 94
  328.        24.3 Target Capacity Check ...................................... 94
  329.        24.4 Error Recovery ............................................. 96
  330.             24.4.1 Data Errors ......................................... 96
  331.             24.4.2 Cross-linked Files .................................. 97
  332.  
  333.    25. EDDY's Default Settings are Lousy! .............................. 98
  334.        25.1 Customizing - "EDDY/0" ..................................... 98
  335.        25.2 Rainbow Selection - [Alt+r] ............................... 100
  336.        25.3 Customizing by PATCHing ................................... 100
  337.             25.3.1 DOS Prompt String .................................. 100
  338.             25.3.2 Data Error Indicator ............................... 100
  339.             25.3.3 I Don't Mind a Little Flicker ...................... 101
  340.             25.3.4 Don't Confuse [F3] and [Enter] ..................... 101
  341.        25.4 How Do I Get Rid of the *$#^&! "UNREGISTERED" Message? .... 101
  342.  
  343.    26. Registration ................................................... 102
  344.        26.1 Pricing ................................................... 102
  345.        26.2 Registration by Credit Card ............................... 103
  346.        26.3 Registration by Mail ...................................... 103
  347.        26.4 "The License" ............................................. 104
  348.        26.5 Pass a Copy to a Friend ("de-personalized") ............... 104
  349.        26.6 EDDY is NOT Free and NOT Public Domain! ................... 104
  350.  
  351.    27. Distribution and Support / Disclaimer .......................... 105
  352.        27.1 Technical Support ......................................... 106
  353.        27.2 How Can I Get in Touch With You? .......................... 107
  354.        27.3 Where Can I Find the Latest Version? ...................... 108
  355.        27.4 A.S.P. Ombudsman .......................................... 109
  356.  
  357.    Appendix A - Command Reference ...................................... a1
  358.  
  359.    Appendix B - What Does That Message Mean? ........................... b1
  360.  
  361.    Registration Form ............................................ last page
  362.  
  363.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page   1
  364.  
  365.  
  366.  
  367.    1. What Does EDDY Do?
  368.  
  369.    EDDY (for EDit DirectorY), a shareware program modestly billed as the
  370.    "World's Greatest Disk Utility!", lets you do WHATEVER you want with your
  371.    files, directories and disks, and minimizes the keystrokes needed to do it.
  372.  
  373.    EDDY is ALL of these...
  374.         Full-screen directory editor
  375.         Disk and directory manager
  376.         DOS shell
  377.         Sector editor
  378.         RAM editor
  379.         File finder (by name, attributes and/or timestamp)
  380.         File viewer/patcher/comparer
  381.         File backup utility
  382.         String finder/replacer (hex and/or ASCII)
  383.         Data recovery utility
  384.    ...and MUCH more!
  385.  
  386.    Most of what EDDY does isn't new; the program was developed as a test of
  387.    the "Build a better mousetrap..." theory of economics.  However, it often
  388.    provides a "new twist" on approaches to old problems.
  389.  
  390.    Some of the features and capabilities that have been reported by users as
  391.    particularly helpful (along with some of my own ideas about what's neat)
  392.    are described in the EDDYREAD.ME file.
  393.  
  394.    EDDY is also cheaper (but NOT free!  It is not in the public domain.) EDDY
  395.    is "user-supported" software, or "shareware".  Distribution and use of EDDY
  396.    are subject to the conditions described in Section 27.
  397.  
  398.  
  399.    1.1 EDDY is Ready if You Are
  400.  
  401.    EDDY needs the following hardware and software:
  402.    - IBM PC, XT, AT, PS/2 or close compatible
  403.    - A monitor that can accommodate 25x80 text mode display
  404.    - At least 180K of available memory
  405.    - PC- or MS-DOS level 2.0 or later, or OS/2
  406.  
  407.    If your monitor can handle more than 25 lines, so can EDDY (up to a maximum
  408.    of 66 lines -- see Section 3.2, option "/9").
  409.  
  410.  
  411.    1.2 Installation
  412.  
  413.    You may use EDDY just as it comes, directly from the distribution disk.
  414.    However, you'll probably want to keep the distribution disk as a backup,
  415.    and copy the files "EDDY.COM" and "EDDY.AUX" to your hard disk, if you have
  416.    one.  There is no other special preparation required.
  417.  
  418.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page   2
  419.  
  420.  
  421.    To start getting familiar with EDDY, make the directory (or diskette)
  422.    containing EDDY.COM current, type "EDDY" (without the quote marks), then
  423.    [Enter].  That's all there is to it!  There are extensive,
  424.    context-sensitive HELP facilities -- press [F1] -- and pull-down menus --
  425.    [Alt+F1].  HELP includes all of the basic information needed to use EDDY.
  426.    There is no danger of damage to your disk data, because no changes will be
  427.    made to any of your directories or files until you tell EDDY to do so.
  428.  
  429.    If EDDY's display is blurred, unreadable, or strange-looking, try "EDDY/M".
  430.    If this works, create a customized copy with option /M on (see Section 25).
  431.  
  432.  
  433.    1.3 EDDY's Display
  434.  
  435.    This is a sample of a typical EDDY display, which might have resulted from
  436.    entering the command "EDDY A:"
  437.  
  438. ================================================================================
  439. filename.ext    size  mmddyy    time    RHYDAS                                 ^
  440. DIR of A:\*.*                                                                  |
  441. Drive A: is DEVELOPMT                109 files, 308224 bytes    2048 bytes free|
  442.                                                                                |
  443. BAT          <DIR>    2-04-87  9:15:04p nnnynn               |======|          |
  444. EDDY         <DIR>    1-25-87 12:52:12p nnnynn               | MENU |          |
  445. AUTOEXEC BAT     788 10-21-86 11:30:10a nnnnyn               |======|          |
  446. CMDSUB   ASM   12856  9-17-86  7:45:26p nnnnyn               [Alt+F1]          |
  447. CMDSUB   OBJ    1246  9-17-86  7:52:38p nnnnyn                         |===|   |
  448. COMMAND  COM   22885 11-26-85 10:22:08p nnnnyn               |======|  | R |   |
  449. CONFIG   SYS      79 10-18-86  7:31:12p nnnnnn               | HELP |  | E |   |
  450. CONVRT   ASM    5927  9-06-86 11:15:16a nnnnnn               |======|  | G |   |
  451. CONVRT   OBJ     499  9-06-86 11:20:52a nnnnnn                 [F1]    | I |   |
  452. ERROUT   ASM    5663  9-15-86  8:15:24p nnnnnn                         | S |   |
  453. ERROUT   OBJ    2127  9-15-86  8:16:12p nnnnnn               |======|  | T |   |
  454. EXX      SYS    9054 11-18-85 12:00:00p nnnnyn               | LOOK |  | E |   |
  455. PRINT    COM    8339 11-18-85 12:00:00p nnnnnn               |======|  | R |   |
  456. PSP      DEF    1195  1-29-87  7:21:04p nnnnyn               [Enter]   |===|   |
  457. UTLSUB   ASM   10649  2-09-87  1:49:34a nnnnyn                        [Alt+z]  |
  458. UTLSUB   OBJ     965  2-09-87  1:50:32a nnnnyn               |======|          |
  459. VDISK    SYS    2721 11-18-85 12:00:00p nnnnnn               | QUIT |          |
  460. WOBBLY   DAT    6001  9-11-83  9:21:42p nnnnyn               |======|          |
  461. WOMBAT   EXE   80201  1-02-83  9:00:46a nnnnnn                [F10]            |
  462.                                                                                |
  463. -EDIT- seq=N  [F2]:UNDO  [F3]:LOOK  [F5]:COPY  [F6]:MOVE  [F7]:DELETE  [F9]:DOSv
  464. ================================================================================
  465.  
  466.                                    Figure 1-1
  467.  
  468.    The rectangles on the right side of the screen are used as "click" buttons
  469.    with a mouse; clicking on them results in the indicated action.  They are
  470.    actually displayed as neat boxes with double outlines, but those characters
  471.  
  472.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page   3
  473.  
  474.  
  475.    don't show up well on many printers.  Although primarily intended for use
  476.    with a mouse, they may also be used with the keyboard.  The "REGISTER"
  477.    button does not appear if you are using a registered copy of the program.
  478.  
  479.    At the right edge is a scroll bar, shown here only as an approximation of
  480.    the actual display.  The scroll bar is also intended mainly for mouse use
  481.    (see Section 2.1.3), but may be used with the keyboard, too.
  482.  
  483.    1.3.1 What Country Are You From?
  484.  
  485.    If you use a date format other than the USA standard "mm-dd-yy", EDDY will
  486.    use the format you choose (usually by use of "COUNTRY.SYS" in your
  487.    CONFIG.SYS file).  The column heading above the date will indicate which
  488.    format is being used, showing "mmddyy", "ddmmyy" or "yymmdd", accordingly.
  489.  
  490.    1.3.2 Printing
  491.  
  492.    To print the directory in the same format as the display, press [Alt+p].
  493.    If you want to stop before the entire directory has been printed, press
  494.    [Alt+p] again; [Alt+p] is a toggle key.
  495.  
  496.    Pressing [Alt+Shift+p] sends a single formfeed to the printer.
  497.  
  498.  
  499.    1.4 What You See Is What You Edit (WYSIWYE?)
  500.  
  501.    EDDY starts by displaying the entries in the selected directory.  You may
  502.    edit those entries, including filename, date, time and attributes.  Just
  503.    move the cursor to the field you want to edit, and type your changes.
  504.  
  505.    You may also select files to be patched, copied, moved, deleted, etc.  All
  506.    changes will be shown on the screen, but no changes will be made on disk
  507.    until you tell EDDY to do so.  EDDY applies the requested changes to disk
  508.    when you enter UPDATE mode, by pressing [Enter].  EDDY will ask you to
  509.    confirm that you want to write to disk (by pressing [Enter] again), and
  510.    will give you the choice of returning to EDIT without making any changes.
  511.  
  512.    At any time before writing changes to disk (in UPDATE mode), you may change
  513.    your mind and UNDO the changes.  You may UNDO changes to the current file
  514.    with [F2], or you may UNDO all changes to all files by pressing [^F2].
  515.  
  516.    1.4.1 Working and Target Directory
  517.  
  518.    The directory displayed by EDDY is referred to as the "working directory".
  519.    If any files are copied or moved, they are put in the "target directory".
  520.  
  521.    The working and target directories may be given on the DOS command line
  522.    when you execute EDDY.  The directories may be changed at any time (see
  523.    Section 5).  If the command line doesn't specify any directory, the current
  524.    directory on the default drive will be the initial working directory.
  525.  
  526.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page   4
  527.  
  528.  
  529.  
  530.    1.4.2 Sequence & Sorting
  531.  
  532.    The information in this section concerns the sequence of the display on the
  533.    screen; you may also sort the directory permanently, on the disk.  Refer to
  534.    Section 23.1 for more details on this.
  535.  
  536.    EDDY's starting display is sorted by file name.  The sequence is indicated
  537.    on the last line of the display.  In Figure 1-1 the last line shows the
  538.    notation "seq=N", indicating sort by NAME.  Possible values of "seq" are:
  539.  
  540.      "D" - sorted by DATE, time, name & extension
  541.      "E" - sorted by EXTENSION & name
  542.      "H" - sorted by HOUR & minute
  543.      "N" - sorted by NAME & extension
  544.      "S" - sorted by SIZE, name & extension
  545.      "U" - UNSORTED; i.e., in the sequence stored in the directory by DOS
  546.  
  547.    EDDY builds the first display in name sequence.  If you would prefer a
  548.    different initial sequence, refer to Section 3.2 for information on the
  549.    use of option /1 to change the sort sequence for the initial display.
  550.  
  551.    To change the sequence, press [Alt+d], [Alt+e], [Alt+h], [Alt+n], [Alt+s]
  552.    or [Alt+u].  The directory will be re-sorted in the sequence requested, and
  553.    the "seq" field on the bottom line will be updated.
  554.  
  555.    Subdirectories are an exception:  except for UNSORTED sequence, all
  556.    subdirectories are grouped at the top of the display, before any file
  557.    entries.  This is to make it easier to move around the disk, from
  558.    subdirectory to subdirectory, using the LOOK command (see Section 8.1).
  559.  
  560.    To invert the order of the display (e.g., to get the files with the most
  561.    recent dates at the top), press [Alt+i].  When the display is inverted, an
  562.    up-and-down arrow appears just to the right of the "seq" field.
  563.  
  564.    Once the display has been inverted, it remains that way until [Alt+i] is
  565.    pressed again; [Alt+i] is a toggle.  Thus, if the display is by date,
  566.    inverted (i.e., newest date first) and you press [Alt+s], the resulting
  567.    display will be by size, inverted (biggest files first).
  568.  
  569.    Inverting is different from sorting.  Inverting just reverses the order of
  570.    the list of files currently displayed, and makes any later sort produce an
  571.    inverted list.  Inverting does not cause the directory to be reprocessed.
  572.  
  573.    Under some unusual circumstances, you may see the following warning message
  574.    when you enter a command to re-sort:
  575.                "Sorting cancels changes not UPDATEd. Sort (y/n)?"
  576.  
  577.    This occurs when you have very little memory available for EDDY's use, and
  578.    there are lots of pending changes when you enter the command.  EDDY will
  579.    always handle at least 160 pending changes without this problem.
  580.  
  581.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page   5
  582.  
  583.  
  584.  
  585.    1.4.3 Number of Files
  586.  
  587.    With displays containing more than one page, an arrow, pointing up and/or
  588.    down appears in the upper right corner to show that there is more data to
  589.    be viewed by scrolling in that direction.
  590.  
  591.    EDDY can display up to 400 or so directory entries, depending on available
  592.    memory.  This is a limit on the display, not on the size of directories.
  593.    If you had, say, 500 files in directory "\BIGDIR", and you wanted to work
  594.    with assembler source files, typing "EDDY \BIGDIR\*.ASM" would yield a
  595.    display of all .ASM files (up to around 400).
  596.  
  597.    If EDDY's display capacity is exceeded, the number of files indicated on
  598.    the third line ("109 files" in Figure 1-1) will be replaced by two numbers.
  599.    The first is the number of files displayed, and the second is the
  600.    additional number of files which would have been displayed if there had
  601.    been enough room.  In Figure 1-1, if the directory had contained 480
  602.    entries, the "109 files" would be replaced by "400+0080 files".
  603.  
  604.    When EDDY finds too many files to display at once, files are "dropped off"
  605.    the end of the list according to the current sequence.  For example, if the
  606.    sequence is by date, inverted, the files with the oldest dates would be
  607.    dropped.  Sorting again will reprocess the entire directory, dropping those
  608.    files which come at the end of the list according to the new sequence.
  609.    (Inverting will redisplay the current list in the opposite order.)
  610.  
  611.    It is possible to display up to double EDDY's capacity, by first displaying
  612.    the files in one sequence and then inverting and re-sorting.  Suppose a
  613.    directory had 500 entries, and was displayed in "Name" sequence.  The first
  614.    400 files would be displayed.  To see the rest of the files in this
  615.    directory, press [Alt+i] followed by [Alt+n].  This would show the rest of
  616.    the files, starting from the opposite end, in inverted sequence.
  617.  
  618.  
  619.    1.4.4 File Sizes & Disk Capacity
  620.  
  621.    The display also shows the number of bytes used by the files in the
  622.    display, and the number of free bytes left on the disk.  Both are multiples
  623.    of the disk cluster size.  Space occupied by subdirectories normally is not
  624.    included in the display.  See the next Section for more on this.
  625.  
  626.    File sizes are counts of bytes of data in the files, rather than bytes on
  627.    the disk assigned to the files; thus, the "bytes used" is normally larger
  628.    than the total of the file sizes.
  629.  
  630.    If the directory has more files than EDDY can display, the "bytes used" is
  631.    the total for all files (i.e., the "350+0120 files" in the example).
  632.  
  633.    For diskettes with no subdirectories, and with all files displayed (*.*),
  634.    the bytes used plus bytes free should equal the disk capacity.  If not, try
  635.    running "CHKDSK" to see if there is some lost disk space to be reclaimed.
  636.  
  637.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page   6
  638.  
  639.  
  640.  
  641.    1.4.5 Directory Sizes
  642.  
  643.    Normally, for a subdirectory, you'll see "<DIR>" in the size field, and the
  644.    space occupied by the directories won't appear in the "bytes used" summary.
  645.    However, these directories do occupy space on the disk.  A single entry
  646.    (file or subdirectory) in a directory requires 32 bytes; thus, 64 entries
  647.    fit in a typical 2048-byte cluster.  If a directory has more entries than
  648.    can fit in a cluster, more clusters are allocated to the directory.
  649.  
  650.    If you'd like to see how much space is actually occupied by the subdirec-
  651.    tories on your disk, use option /D (see Section 2.3 for a discussion of
  652.    options).  But be prepared to wait longer for the display to be built; DOS
  653.    does not report directory sizes through its normal services.  EDDY must
  654.    interpret low-level format and FAT information directly, reading the
  655.    relevant sectors of the disk to get this information.  The sizes are shown
  656.    between "<" and ">" brackets (e.g., "<2048>", so directories are still
  657.    easily differentiated from files in the display.
  658.  
  659.    When displayed, directory sizes (except for the "." and ".." entries) are
  660.    included in the "bytes used" summary.  The size of the "." entry is the
  661.    size of the directory being displayed; it is not part of the space
  662.    allocated to the files in that directory.  The ".." entry is also not
  663.    included in the summary figure.  If the ".." entry is actually the root
  664.    directory, you will see "<ROOT>" instead of a size, as the root size is
  665.    fixed by the formatting process, and does not occupy space that would
  666.    otherwise be available for file storage.
  667.  
  668.    If you delete entries, the directory space is NOT released; directories
  669.    always stay as large as the most space that was ever required for them,
  670.    even if there are NO files currently in the directory.  With standard DOS
  671.    facilities, the only way to free up unused directory space is by deleting
  672.    the directory itself.  EDDY offers another way, allowing you to free up
  673.    space wasted in this way; see Section 23.3 for more information on this.
  674.  
  675.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page   7
  676.  
  677.  
  678.    2.  Telling EDDY What To Do
  679.  
  680.    As mentioned above, EDDY's basic display provides full screen editing
  681.    capabilities -- just move the cursor to the data you want to change, and
  682.    type in the new data.
  683.  
  684.    The cursor may be moved with the keyboard or by mouse.  A "scroll bar" is
  685.    also available.  [NumLock] state (ON/OFF) is always ignored by EDDY --
  686.    i.e., treated as OFF -- unless [NumLock] is pressed while EDDY is running.
  687.    Once it has been pressed, its state is recognized and treated accordingly.
  688.  
  689.    Other capabilities of EDDY are called upon by using commands.  Commands may
  690.    be entered in whichever of the following ways you find most convenient:
  691.  
  692.          - Hot Keys
  693.          - Pull-Down Menus
  694.          - Command Line
  695.  
  696.  
  697.    2.1 Moving Around
  698.  
  699.    Some fields on the screen, such as file size, can't be edited.  These
  700.    fields are "protected" so that the cursor can't be moved to that position.
  701.    Instead, it will move to the next unprotected position.
  702.  
  703.    2.1.1 Using the Keyboard
  704.  
  705.    In this document, key names are enclosed in brackets -- "[" and "]".
  706.  
  707.    The "arrow" characters are not printable in general, so the cursor control
  708.    keys are indicated by the word -- left, right, up, down -- for the
  709.    direction of the arrow that's printed on the key cap.
  710.  
  711.    In key names, the prefix "^" means the key is pressed at the same time as
  712.    the [Ctrl] shift key.  The notations [Alt+key] or [Shift+key] mean that the
  713.    [Alt] or [Shift] key is pressed at the same time as the indicated "key".
  714.  
  715.    EDDY's cursor is moved around in the display as follows:
  716.  
  717.      [Up]     - move up 1 line           [PgUp]   - up 1 page
  718.      [Down]   - move down 1 line         [PgDn]   - down 1 page
  719.      [Home]   - move to top of page      [End]    - move to end of page
  720.      [^Home]  - display first page       [^End]   - display last page
  721.      [Left]   - left 1 column            [Right]  - right 1 column
  722.      [Shift+Tab] - left 1 field          [Tab]    - right 1 field
  723.      [^Left]  - move to column 1         [^Right] - move to last column
  724.  
  725.      [/] - move to date field                [:] - move to time field
  726.      [.] - left edge, except in a filename field [.] moves to extension
  727.      [+] - move to attribute field (except in an attribute field, [+] toggles
  728.            the attribute setting and moves to the next file)
  729.  
  730.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page   8
  731.  
  732.  
  733.    2.1.2 Using a Mouse
  734.  
  735.    EDDY reacts to mouse movement just as if you had used the arrow keys in a
  736.    corresponding way (UNLESS you have moved all the way right, past the end of
  737.    the highlighted area, to the scroll bar -- more on that in Section 2.1.3).
  738.  
  739.    Pressing the left mouse button ("left clicking") in EDIT mode is the same
  740.    as pressing [F3].  With the cursor on a directory line, EDDY makes that the
  741.    new working directory; a left click on a file line LOOKs at that file.
  742.    This may be changed -- see Section 2.1.2a, below.
  743.  
  744.    When EDDY is waiting for confirmation that you want to proceed with some
  745.    action, a left click means "Yes, proceed".  A right click is the same as
  746.    [Esc], or "No, don't proceed".
  747.  
  748.    If EDDY asks for either [Enter] or [^Enter], a left click is the same as
  749.    [Enter], and a double left click is the same as [^Enter].
  750.  
  751.    Click the left button while the cursor is on the "MENU" or "HELP" box at
  752.    the right side of the screen to get the corresponding display.  Click the
  753.    right button to return to the main body (left portion) of the display.  You
  754.    may move the cursor around elsewhere in this area, but it has no effect.
  755.  
  756.    a. Changing the Button Command - [Alt+m]
  757.  
  758.    To change the command used for the left mouse button in EDIT mode, press
  759.    [Alt+m].  Next, press the key for the command that you prefer to use.
  760.    Also, see the following section.
  761.  
  762.    b. If You're Left-handed
  763.  
  764.    After [Alt+m], you may click the right mouse button instead of pressing a
  765.    key.  This swaps the use of the left and right mouse buttons, which is
  766.    preferred by some left-handed people.  In that case, all descriptions of
  767.    the right button actions actually apply to the left button, and vice versa
  768.    (except in this paragraph -- the right button is ALWAYS used to swap).
  769.  
  770.    In the display line shown at the top of this page, note the "*" at the left
  771.    end of the series of "^"s; this "*" indicates that the primary mouse button
  772.    is the left button, corresponding to the usage described in this manual.
  773.    If you swap the button usages (making the right button primary), the "*"
  774.    will be shown at the right end of the "^"s.
  775.  
  776.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page   9
  777.  
  778.  
  779.  
  780.    c. Mouse Sensitivity - [Alt+Shift+m]
  781.  
  782.    If your mouse reacts too quickly or too slowly when you move it, you can
  783.    adjust the sensitivity.  Press [Alt+Shift+m], and you'll get a display
  784.    showing the current speed relative to the maximum and minimum possible.
  785.    Move the mouse left to slow the mouse down or right to speed it up.
  786.    Left-click when the speed is the way you like it.
  787.  
  788.    If you customize EDDY, the sensitivity you select will be the default in
  789.    the customized copy.
  790.  
  791.    Some mouse drivers are not fully compatible with the Microsoft standards,
  792.    particularly with respect to how the sensitivity is handled.  If you're
  793.    using one of these drivers, EDDY won't be able to adjust the sensitivity.
  794.  
  795.    2.1.3 Using the Scroll Bar
  796.  
  797.    At the far right edge of the screen you'll see a single, shaded column with
  798.    an arrow at either end; this is the "scroll bar".  Its main purpose is to
  799.    give you an easy way of moving the display up or down with a mouse,
  800.    although you may use it with the keyboard, too, if you wish.
  801.  
  802.    The scroll bar also shows a highlighted box (the "slider").  The position
  803.    of the slider on the scroll bar gives you an approximate indication of how
  804.    much further you must scroll to get to the end of the display.  For
  805.    example, if EDDY has selected 90 files for display, and your current file
  806.    is the 30th, the slider will be about 1/3 of the way down on the scroll
  807.    bar.  If you're on the 90th file, the slider will be at the bottom.
  808.  
  809.    To use the scroll bar, move the cursor to a position either above or below
  810.    the slider, and press the left mouse button (or [Enter]).  The display will
  811.    scroll up if the cursor is above the slider, or down if below.  (If the
  812.    cursor is right on the slider, no scrolling occurs.)
  813.  
  814.    The amount of scrolling depends on where the cursor is located.  If it is
  815.    on one of the arrows at either end of the scroll bar, the display will
  816.    scroll a line at a time in the indicated direction.  Elsewhere on the
  817.    scroll bar, each click moves the display a page at a time.
  818.  
  819.    Holding the left mouse button (or [Enter]) down causes the scrolling action
  820.    to repeat.  If you are paging, this can cause the cursor to alternately be
  821.    above and below the slider, which will keep repeating the same two pages of
  822.    the display.  Not terribly useful, but being documented makes it a feature
  823.    rather than a bug.
  824.  
  825.    Click the right mouse button (or press [Esc]) to move quickly back to the
  826.    main body of the display.  You may also move the mouse or use the arrow
  827.    keys for this if you prefer.
  828.  
  829.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  10
  830.  
  831.  
  832.  
  833.    2.2 Commands
  834.  
  835.    Commands tell EDDY what to do to the files that are displayed.  Generally,
  836.    they affect the current file, as selected by the cursor.
  837.  
  838.    The most common commands are assigned to function keys.  Other commands
  839.    generally are assigned to an [Alt+letter] combination.
  840.  
  841.    2.2.1 Hot Keys
  842.  
  843.    All of EDDY's functions may be called upon by using the corresponding "hot
  844.    keys".  The following (VERY incomplete!) summary is provided simply to
  845.    suggest how easy it is to use some of EDDY's most common commands.
  846.  
  847.    Further details of use of the various keys and key combinations may be
  848.    found in the later sections of this document.  A complete list of command
  849.    key assignments is given in Appendix A.
  850.  
  851.    Some common commands used in "EDIT" mode are:
  852.  
  853.    [F1]: HELP
  854.    [F2]: UNDO changes on this file
  855.    [F3]: LOOK at data in file, LOOK at files in directory, or LOOK at disk
  856.    [F4]: PATCH data in file or on disk
  857.    [F5]: COPY file
  858.    [F6]: MOVE file
  859.    [F7]: DELETE file
  860.    [F9]: Exit to DOS temporarily (DOS shell)
  861.    [F10]: QUIT, return to original default directory
  862.  
  863.    [Alt+d]: Sort files by DATE/time           [Alt+n]: Sort files by NAME
  864.    [Alt+e]: Sort files by EXTENSION           [Alt+s]: Sort files by SIZE
  865.                         [Alt+i]: INVERT display sequence
  866.  
  867.    [Alt+f]: FIND string in file
  868.    [Alt+o]: inquire/change OPTIONS
  869.    [Alt+t]: inquire/change/create TARGET directory
  870.    [Alt+w]: change WORKING directory/file selection
  871.    [Alt+x]: eXCHANGE working & target directories
  872.  
  873.    Many command keys may also be used together with the [Ctrl] key.  [Ctrl]
  874.    (indicated in this document by "^") means "do the command for all files".
  875.    E.g., [^F5] means copy all files, and [^F2] means undo all changes on all
  876.    files.  (Option /L -- Section 2.3 -- changes the scope of the "^".)
  877.  
  878.    To interrupt one of the [^Fn] commands, press [^c] or [BackSpace].  Any
  879.    files tagged for copy, delete, etc. up to that point will stay tagged, but
  880.    no further action will take place.  If you just want to pause temporarily,
  881.    to look at the screen or think about what's going on, press and hold
  882.    [ScrollLock].  All processing will stop.  Release the key to continue.
  883.  
  884.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  11
  885.  
  886.  
  887.  
  888.    2.2.2 Pull-Down Menus - [Alt+F1]
  889.  
  890.    Press [Alt+F1] and a pull-down menu panel is displayed, as well as a menu
  891.    bar across the top of the screen, with other menu topics to choose from.
  892.  
  893.    The menu panel lists commands which may be executed by EDDY.  To the right
  894.    of each command a "hot key" is shown.  This key may be used to execute the
  895.    command directly from EDDY, without using the menu.  To select a command
  896.    from the menu, you may:
  897.  
  898.        1) press the highlighted letter for that command; or
  899.        2) move the cursor to the command and press [Enter] (or left click
  900.               your mouse); or
  901.        3) press the indicated "hot key" for the command (unless the hot
  902.               key is shown enclosed by "< >", in which case the hot key cannot
  903.               be used from the menu).
  904.  
  905.    Some lines on some panels show "(sub-menu)" instead of a hot key.  If you
  906.    choose one of these, another panel will be displayed, with commands
  907.    relating to the subject you chose.  These commands may be selected in the
  908.    same 3 ways described above.
  909.  
  910.    If you don't want to choose a command, press [Esc] (or right click mouse).
  911.  
  912.    To view the data in the display that has been covered by a menu panel,
  913.    press [PgUp].  This allows you to look at the display (except the top line,
  914.    which is covered by the menu bar) without exiting from the menu.  To pull
  915.    down a menu panel, press the highlighted letter for the topic, or press
  916.    [Enter] (or left click) to pull down the panel for the
  917.    currently-highlighted topic.
  918.  
  919.    A list of other topics available is displayed across the top of the screen.
  920.    The topics are those which pertain to the type of display you are working
  921.    with.  For example, in EDIT mode, you won't see topics that relate to LOOK
  922.    or PATCH modes.  To view the panels for the other topics shown at the top
  923.    of the screen, press [Left] or [Right] (or move the mouse).
  924.  
  925.    In EDIT mode, the choice of topics also depends on the line your cursor is
  926.    currently on.  If it's on a file, you'll get a choice of commands that are
  927.    valid for files; if it's on a directory or disk line, you'll get choices
  928.    that are valid for those lines.
  929.  
  930.    Similarly, in LOOK mode, some commands are valid only if the display is in
  931.    ASCII (text) format, and some only with hex format.  Also, different
  932.    commands are available when LOOKing at a file, disk or RAM.  The choices
  933.    you'll see in the menus depend on what you're doing.
  934.  
  935.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  12
  936.  
  937.  
  938.  
  939.    The first time a particular menu bar is loaded at the top of the screen,
  940.    EDDY makes a guess as to which panel from that menu bar you'll most likely
  941.    want to use, and displays that panel.  On later calls which use that same
  942.    menu bar, the menu panel displayed will be the last one you used.
  943.  
  944.    EDDY loads the MENU module from EDDY.AUX when you press [Alt+F1], if enough
  945.    memory is available (around 24K).
  946.  
  947.    The first time you ask for the menu, it will take a little longer than
  948.    subsequent requests, as the disk must be read.  The MENU module then stays
  949.    resident unless the DOS Gateway is used.
  950.  
  951.    The menus and HELP screens have their own color attributes, not tied to
  952.    those used for other EDDY screens (but menu colors are the same as HELP
  953.    colors).  These colors may be customized as desired (see Section 25.2).
  954.  
  955.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  13
  956.  
  957.  
  958.  
  959.    2.2.3 Dialog Boxes
  960.  
  961.    Some commands need more information in order to accomplish their functions.
  962.    For example, [Alt+Shift+t] is used to select a new target directory; press-
  963.    ing it displays a dialog box asking you to enter the required path.
  964.  
  965.    For these boxes, just type the required information, and press [Enter] when
  966.    you are finished.  EDDY will use the new information according to the type
  967.    of command involved.  If you make a mistake, or decide not to continue,
  968.    press [Esc] and whatever you have typed will be discarded.
  969.  
  970.    Dialog boxes are used with these commands:
  971.         [Alt+t]/[Alt+Shift+t]:  inquire/change/create TARGET directory
  972.         [Alt+v]:  change/create VOLUME label
  973.         [Alt+w]/[Alt+Shift+w]:  change WORKING directory/file selection
  974.         [^w]:  "Where's That File?" search for WORKING directory
  975.         [Shift+F9]:  point-n-shoot
  976.  
  977.    They may also appear as the result of some other commands, such as [F5] -
  978.    COPY file -- when no target directory has been given.
  979.  
  980.    When a dialog box is displayed, the area into which you may type data is
  981.    highlighted in reverse video (or underline, with monochrome monitors).
  982.    Text entry may be done in either "insert" mode, in which each keystroke
  983.    entered pushes everything right one character, or "replace" mode, in which
  984.    each keystroke overlays the character at the cursor.  You may toggle
  985.    between insert and replace modes by pressing [Ins].  If you are in insert
  986.    mode, a "right arrow" will appear directly below the cursor.  When the
  987.    dialog box is first displayed, replace mode is in effect.
  988.  
  989.    If there is an initial string displayed, such as a path, you may edit it as
  990.    desired, and press [Enter] when the result is ready for use.
  991.  
  992.    If the first key you press after the initial display is a character (i.e.,
  993.    not a cursor control key) in the first (leftmost) position, the initial
  994.    string will be erased, allowing a completely new string to be entered.  In
  995.    addition, [^End] will always erase from the cursor to the end of line.
  996.  
  997.    If you want to redisplay the initial string after it has been erased, or
  998.    after you have modified it, move the cursor to the leftmost position and
  999.    press [Home].
  1000.  
  1001.    NOTE: The dialog boxes associated with the commands...
  1002.  
  1003.         [Alt+f]: FIND string in file
  1004.         [Alt+r]: FIND and REPLACE string in file
  1005.  
  1006.    do not follow these rules.  Refer to Section 16 for more information.
  1007.  
  1008.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  14
  1009.  
  1010.  
  1011.  
  1012.    2.2.4 List Boxes
  1013.  
  1014.    These boxes present a list of items for which state values may be selected
  1015.    (e.g., "ON/OFF", "YES/NO/MAYBE").  List boxes are used with these commands:
  1016.  
  1017.         [Alt+a]: file attribute filter selection
  1018.         [Alt+c]: inquire/change controls for Copy & Move
  1019.         [Alt+o]: inquire/change options
  1020.  
  1021.    To set values for an item in the list, move the highlighted cursor bar to
  1022.    the item and click the left mouse button or press [Tab].  When all values
  1023.    are set correctly, move the cursor to the "OK/Cancel" line, ensure the "OK"
  1024.    box is highlighted, and left click or press [Enter].  The highlight can be
  1025.    moved between "OK" and "Cancel" by pressing [Left] or [Right].
  1026.  
  1027.    If you click on this line or [Enter] while "Cancel" is highlighted, all
  1028.    changes will be discarded.  Changes may be discarded at any time by right
  1029.    clicking or pressing [Esc] -- from any line.
  1030.  
  1031.    To restore settings to the values they had when EDDY started executing --
  1032.    the default values, possibly modified by settings made from the command
  1033.    line -- press [*] or left click on the "*" line.
  1034.  
  1035.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  15
  1036.  
  1037.  
  1038.  
  1039.    2.3 Options - [Alt+o]
  1040.  
  1041.    Options tell EDDY which of two possible courses of action you want used in
  1042.    various situations.  For example, you may choose option settings to
  1043.    determine:  1) if and how a file's "archive" attribute should be changed
  1044.    when the file is copied; 2) whether to interpret characters typed in the
  1045.    filename field as changes to the filename or as a signal to search for a
  1046.    matching filename; 3) whether to use color in the display or not.
  1047.  
  1048.    Options may be set either ON or OFF, with corresponding meanings described
  1049.    below.  Options (unless EDDY has been otherwise customized, as described in
  1050.    Section 25) are initially set to OFF.
  1051.  
  1052.    You may change option settings (except /U and /W) by pressing [Alt+o].  A
  1053.    list box will appear.  Pressing any of the option letters toggles the
  1054.    option setting between ON and OFF.  Or move the cursor to an option and
  1055.    click the left mouse button or press [Tab].  When the settings are the way
  1056.    you want them, press [Enter].  Pressing [*] resets the options to the
  1057.    values they had when EDDY started:  i.e., the default values, as modified
  1058.    by any options you used on the command line (see Section 3.2).
  1059.  
  1060.    Options which may be set from the list box are designated by letters.  In
  1061.    addition to those options, there are certain options which may only be
  1062.    specified from the command line.  These are designated by numbers.  The
  1063.    available letter options are:
  1064.  
  1065.    /A - Do not change the file archive (modify) attribute when copying or
  1066.    moving files.  Default (option /A OFF) action depends on the drives used...
  1067.      - Floppy to floppy: copy's attributes set same as original
  1068.      - Hard disk to hard disk: copy's attributes set same as original
  1069.      - Floppy to hard disk: copy's archive attribute OFF, original unchanged
  1070.      - Hard disk to floppy: copy's archive attribute ON, original OFF
  1071.      - Remote (network) drives: attributes never changed
  1072.  
  1073.    /B - Turn off the "beep" that normally sounds for errors or warnings.
  1074.  
  1075.    /C - Do not change the cursor size.  Default is to use a larger cursor in
  1076.    EDIT mode, a full-height cursor in PATCH mode, and set it to a two-pixel
  1077.    high underline at exit.  If you start EDDY with this option OFF, and then
  1078.    turn it on, EDDY will not reset the cursor at exit.
  1079.  
  1080.    With /E and /C both ON, /C has no effect - i.e., the cursor will be changed
  1081.  
  1082.    /D - Include directory sizes in the display.  Disk space used by subdirec-
  1083.    tories is normally not included in the EDIT mode display.  With option /D
  1084.    ON, all such space will be accounted for.  However, gathering the infor-
  1085.    mation is VERY time-consuming, particularly on lower-speed hardware, so you
  1086.    may wish to use it only if it is really important to you.
  1087.  
  1088.    Option /D has no effect on remote (network) drives.
  1089.  
  1090.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  16
  1091.  
  1092.  
  1093.    /E - Set EGA or VGA monitor to use "extra-line" text display mode (43 or 50
  1094.    lines).  If the monitor is already in extra-line mode when EDDY starts, the
  1095.    option display window -- [Alt+o] -- will show /E is ON.  If you change /E
  1096.    while in EDDY, the display mode will change immediately.  If you were also
  1097.    using option /C, that option is turned OFF when /E changes
  1098.  
  1099.    /F - Turn on filename editing (i.e., renaming).  When /F is ON, files may
  1100.    be renamed by typing the new filename over the old.  If /F is OFF, typing
  1101.    in the filename field causes a "speed search" for a file with a matching
  1102.    name.  See Section 4.1 for more on this.
  1103.  
  1104.    With option /F turned OFF, pressing [Ins] in EDIT mode turns renaming ON
  1105.    for that file only, until the cursor moves to another line.  When option /F
  1106.    is ON (file renaming enabled), a "." appears between the filename and
  1107.    extension fields.  If it is ON for only the current file (i.e., you pressed
  1108.    [Ins]), then only that file's display has the ".".
  1109.  
  1110.    /H - Files with "hidden" or "system" attributes are not mormally displayed
  1111.    unless they are explicitly requested by use of attribute filtering -- and
  1112.    with filtering, ONLY files with those attributes will be shown.  To include
  1113.    these files by default, together with all other files, use option /H.
  1114.  
  1115.    /K - Some error and status messages are displayed briefly (about 3 seconds)
  1116.    and then disappear.  If you would rather have the messages remain until you
  1117.    press a key (any key), use this option.  In this case, if the key you press
  1118.    is one of EDDY's command keys, the command will be executed.
  1119.  
  1120.    /L - List control.  Changes the scope of the [Ctrl]-shifted commands.
  1121.    Normally, these commands affect all files listed, starting from the top of
  1122.    the display (i.e., the first file).  If you want EDDY to start from the
  1123.    current cursor position (ignoring files higher up in the list), use /L.
  1124.  
  1125.    /M - Monochrome monitor.  Useful with mono monitor + Color Graphics
  1126.    Adapter, and with some laptops' screens.  Other equipment combinations do
  1127.    not need this option, although it will toggle between color and mono
  1128.    displays on any color monitor.
  1129.  
  1130.    /R - RAM Editing.  With this option turned ON, EDDY treats the PC's memory
  1131.    as a file, which you may LOOK at, FIND strings in, PATCH or COPY.
  1132.  
  1133.    /U - Use minimum memory.  Default is to expand to 180K, if that much is
  1134.    available.  A maximum of 110K will be used if this option is turned on.
  1135.    Using this option means that fewer files can be accommodated (currently,
  1136.    around 115), and a smaller I/O buffer will be used, which means slower
  1137.    copying and moving...UNLESS you have LIM/EMS expanded memory.  Expanded
  1138.    memory will be used if available, and the buffers will be full size.
  1139.  
  1140.    /W - Set "Where's That File?" searching; move to next directory that has a
  1141.    file which matches the current file spec and any timestamp and/or attribute
  1142.    filter used.  Search from current directory downward in the directory tree.
  1143.    This option can be set by the user ONLY from the DOS command line.  It is
  1144.    set internally by EDDY when the [^w] command is used.
  1145.  
  1146.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  17
  1147.  
  1148.  
  1149.  
  1150.    3. EDDY's DOS Command Line
  1151.  
  1152.    When EDDY is executed without any options, paths or filenames given on the
  1153.    DOS command line, the current default drive and directory path are used.
  1154.  
  1155.    The command line format is:
  1156.  
  1157.    EDDY [/option...] [work] [target] [+attribute...] ["timestamp"]
  1158.  
  1159.    (The brackets -- "[" and "]" -- are not part of the format, and should not
  1160.    be typed on the command line)
  1161.  
  1162.    All parameters are optional.  The last two parameters, "attribute" and
  1163.    "timestamp", are for use in selecting files to be displayed by criteria
  1164.    other than paths and filenames with wildcards.  Full explanations of these
  1165.    are given in Section 17.
  1166.  
  1167.    If you enter a command line in the wrong format, the format description
  1168.    line (above) will be displayed, with an arrow pointing to the parameter in
  1169.    error.
  1170.  
  1171.  
  1172.    3.1 Path Specifications
  1173.  
  1174.    On the command line, [work] defines the working directory, in normal DOS
  1175.    format, just as used with the DIR command (d:\path\filename.ext).  Wild
  1176.    card characters are supported.  If no filename is given, *.* is assumed.
  1177.    Paths may be specified using either "\" or "/", as you prefer.  Similarly,
  1178.    ";" is treated as ":", on the assumption that you forgot to [Shift].
  1179.  
  1180.    [target] defines the target directory, to receive any files copied or
  1181.    moved.  No filenames are allowed in the [target] specification.
  1182.  
  1183.    For example, "EDDY .  c:" would display all files in the current default
  1184.    directory, and any files copied or moved would go to the current directory
  1185.    of drive "c:".
  1186.  
  1187.    If you enter an unambiguous filename -- i.e., no wildcards -- EDDY will go
  1188.    straight into LOOK mode for that file.  When you exit LOOK, the working
  1189.    directory will be "*.*".  (After going to LOOK in this way, you may notice
  1190.    that your disk's "busy" light comes on for a bit.  Not to worry!  EDDY is
  1191.    using the time between keystrokes to build the "*.*" display, to be ready
  1192.    when you exit from LOOK.)
  1193.  
  1194.    For example, "EDDY c:\testdir\abc" would display all files in subdirectory
  1195.    "\abc" or, if there is no such subdirectory, display the contents of file
  1196.    "abc" in the "testdir" subdirectory.
  1197.  
  1198.    Working and target directories may be changed during execution, as
  1199.    explained in Section 5.
  1200.  
  1201.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  18
  1202.  
  1203.  
  1204.  
  1205.    3.2 Options on the Command Line
  1206.  
  1207.    Options may also be given to EDDY on the DOS command line, as with normal
  1208.    DOS commands, -- e.g., "EDDY/A/K" tells EDDY to use options "A" and "K".
  1209.    Options, if any, must be first, before any path or other specifications.
  1210.  
  1211.    If your version of DOS supports "switch" characters other than "/" for
  1212.    command line parameters (options), EDDY will accept whatever character you
  1213.    use with your system (e.g., "-" is preferred by some users).
  1214.  
  1215.    Details of the options are presented in Section 2.3.  In addition to those
  1216.    options, which are known by their "letter" designators, there are certain
  1217.    parameters which may be specified from the command line.  These options are
  1218.    designated by numbers.  They allow specification of settings that are not
  1219.    the normal defaults for the way you use EDDY, or for batch operations (see
  1220.    Section 20).  The numeric options are:
  1221.  
  1222.    /0 -
  1223.         Execute in "customize" mode, to create a copy of EDDY with various
  1224.         features tailored to your preference (see Section 25).
  1225.  
  1226.    /1x -
  1227.         Override the normal startup display sequence.  "x" must be one of the
  1228.         sort sequence codes defined in Section 1.4.2.  If "x" is a capital
  1229.         letter, the sequence will be in ascending order; if lowercase, in
  1230.         descending order.
  1231.  
  1232.    /2xxxxxx -
  1233.         Override the normal Synchronization Control settings, as described in
  1234.         Section 10.  From 1 to 6 "x"s may be used.  Each "x" must be "c", "y"
  1235.         or "n" except "c" is invalid for the sixth one.  Either case is O.K.
  1236.  
  1237.    /5, /6, /7, /8 -
  1238.         These options correspond to keys [^F5], [^F6], [^F7] and [Shift+^F7]
  1239.         (COPY, MOVE, DELETE and DESTROY all files).  Only one of these options
  1240.         may be used at a time.  When any of these are used, the corresponding
  1241.         command is carried out in batch mode.
  1242.  
  1243.  
  1244.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  19
  1245.  
  1246.  
  1247.    /9nn -
  1248.         EDDY determines the number of lines per screen from a byte in memory
  1249.         that is set by the PC BIOS.  Some BIOSes apparently don't maintain
  1250.         this byte correctly for some monitors.  If this seems to be your
  1251.         situation (i.e., EDDY doesn't use all the lines your screen can
  1252.         handle), try using /9, with "nn" set to a number from 25 through 66.
  1253.  
  1254.         Using a number greater than the monitor can handle has unpredictable
  1255.         results.  This option should not be used with EGA or VGA monitors.
  1256.         Screen height is adjusted with these monitors by using Option /E.
  1257.  
  1258.  
  1259.    3.3 Other Command Line Parameters
  1260.  
  1261.    Two other parameters may be entered on the command line:  an "attribute
  1262.    filter" specification and/or a "timestamp filter" specification.  These
  1263.    specifications are used to select files for display based on their file
  1264.    attributes -- hidden, directory, etc.  -- or date and time.  They are
  1265.    explained in detail in Sections 17.1.1 and 17.2.1, respectively.
  1266.  
  1267.  
  1268.    4.  Editing Directory Entries
  1269.  
  1270.    To select a file for editing, move the cursor to the line of the display
  1271.    for that file.  The line with the cursor will be highlighted, and the
  1272.    corresponding file becomes the "current file".  Editing is then done by
  1273.    simply typing the new information over the old on the screen.
  1274.  
  1275.    The cursor will skip over fields which can't be edited, such as file size.
  1276.    If you try to enter data which is not valid (e.g., letters in a date or
  1277.    time field), EDDY will "beep" at you and ignore the entry.
  1278.  
  1279.    It is possible to enter combinations of characters which result in invalid
  1280.    data in a field.  For example, "02" is a valid month and "31" is a valid
  1281.    day, but together they are an invalid date.  EDDY catches errors of this
  1282.    type whenever you try to move the cursor off of the current file.  EDDY
  1283.    "beeps" and puts the cursor on the field where the error was detected.
  1284.  
  1285.    When any editing has been done, an "*" will appear at the right end of the
  1286.    line to indicate that changes have been made to that file.
  1287.  
  1288.  
  1289.    4.1 Selecting a File or Directory (Speed Search)
  1290.  
  1291.    There are two ways to move the cursor to the file (or directory) entry you
  1292.    are interested in:  by using the cursor keys ([Up], [Down], etc.), or
  1293.    directly, by using the "speed search" feature (with option /F turned OFF).
  1294.  
  1295.    With the cursor on the filename, typing any character that's valid for a
  1296.    filename tells EDDY to move the cursor to the next entry in the display
  1297.    with a name that matches.  Matching is done from the first character of the
  1298.    current filename up to and including the character just typed.
  1299.  
  1300.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  20
  1301.  
  1302.  
  1303.  
  1304.    For example, consider the display shown in Figure 1-1 (Section 1.3).  If
  1305.    you were positioned on the "WOMBAT" entry, with the cursor on the "W", and
  1306.    you pressed [e], the cursor would move to the "EDDY" directory entry, with
  1307.    the cursor on the first "D".  If you then pressed [r], the cursor would
  1308.    move to the "ERROUT.ASM" filename, on the second "R".
  1309.  
  1310.    If you press [Shift] and type a letter, that letter will always be matched
  1311.    against the FIRST letter of the file or directory name, regardless of which
  1312.    byte of the name the cursor is currently positioned on.
  1313.  
  1314.    Refer again to Figure 1-1.  Suppose you were positioned at the top of the
  1315.    file list, and held down [Shift] while pressing [e] three times in a row.
  1316.    The cursor would move first to the "EDDY" directory entry, then to the
  1317.    "ERROUT.ASM" filename, and finally to the "ERROUT.OBJ" filename.
  1318.  
  1319.    Speed search is disabled when option /F is ON.
  1320.  
  1321.    Speed search is also available for choosing directories from the directory
  1322.    tree display, as described in Section 5.3.2.
  1323.  
  1324.  
  1325.    4.2 Renaming Files
  1326.  
  1327.    Turn on option /F (explained in Section 2.3) if you want to rename files.
  1328.    If this method is used, speed search, as described above, is disabled;
  1329.    typing over the filename field renames the file.
  1330.  
  1331.    To rename a file without disabling speed search, first press [Ins].  This
  1332.    turns on /F only while the cursor remains on the current line; as soon as
  1333.    it moves to a new line, /F is reset.
  1334.  
  1335.    To rename a file, type the new name over the old on the screen.  A "*" will
  1336.    appear to the right of the extension, to remind you that a change has been
  1337.    made.  The file will be renamed on disk when you enter UPDATE mode.
  1338.  
  1339.    Any valid characters for filenames may be entered, including spaces (except
  1340.    the first character may not be a space).  Valid characters are any in the
  1341.    range 20h through 7Eh, except for these:  [ . " / \ :  | < > + = ; , ]
  1342.  
  1343.    Lower case letters are converted to upper case by DOS.  You can rename
  1344.    files with EDDY so that they can't be used with normal DOS commands, by
  1345.    using names containing embedded blanks.
  1346.  
  1347.    When you rename a file, after UPDATE it will be moved to its proper place
  1348.    in the display, according to the sort sequence then in effect.
  1349.  
  1350.    When you rename a file, but you have not yet UPDATEd, the new name is used
  1351.    in any situation involving comparison of directory entries in the working
  1352.    and target directories.  For example, when comparing timestamps for a COPY
  1353.    command, the comparison process will use the entry (if any) in the target
  1354.    with a name matching the NEW name shown for the current file.
  1355.  
  1356.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  21
  1357.  
  1358.  
  1359.  
  1360.    4.3 Changing Date and Time
  1361.  
  1362.    Dates are displayed in mmddyy, ddmmyy, or yymmdd format, depending on the
  1363.    use of DOS's "COUNTRY.SYS; times are displayed based on a 12-hour clock
  1364.    with an "a" or "p" to show a.m. or p.m.
  1365.  
  1366.    Only valid month/day/year combinations may be entered.  Hours in the range
  1367.    01 to 12 are accepted; minutes and seconds must be less than 60.  Seconds
  1368.    may be set only to even numbers -- a DOS limitation.  (Except:  You can set
  1369.    the date and time to all zeros.  If you do this, the timestamp will not be
  1370.    displayed at all when you use the DOS "DIR" command.  Useful to call
  1371.    attention to entries in "DIR" listing).
  1372.  
  1373.    EDDY uses its own timestamp.  EDDY's timestamp is either the current DOS
  1374.    date and time, or a date and time which has been set by pressing
  1375.    [Alt+equal].  Pressing [Alt+equal] freezes EDDY's timestamp at the date and
  1376.    time of the current file or directory until changed by another [Alt+equal].
  1377.  
  1378.    Pressing [=] puts EDDY's timestamp on the file if [Alt+equal] has been
  1379.    pressed previously; if not, the current DOS date and time is used.
  1380.  
  1381.    [Alt+minus] undoes the effect of a previous [Alt+equal].
  1382.  
  1383.    When a change has been made to the date or time, an asterisk will appear in
  1384.    the line to the right of the field changed.
  1385.  
  1386.  
  1387.    4.4 Changing File Attributes
  1388.  
  1389.    Attribute bit settings are displayed under the heading "RHYDAS", indicating
  1390.           R)EAD-ONLY, H)IDDEN, SY)STEM, D)IRECTORY, A)RCHIVE and S)HARED
  1391.    file attributes, respectively.
  1392.  
  1393.    A "y" indicates the attribute is on for this file; "n" means it is off.
  1394.  
  1395.    The attribute bit settings may be changed by typing the new value over the
  1396.    old, except the "directory" and "shared" attributes can't be changed.
  1397.  
  1398.    When you type "y" or "n" in an attribute field, the cursor moves right, to
  1399.    the next attribute for that file.  If you want to change attributes on a
  1400.    series of files (e.g., removing read-only attributes) press [+] to toggle
  1401.    the attribute ON/OFF (y/n).  The cursor then moves to the next file's
  1402.    attribute field, in the same column.
  1403.  
  1404.    When a change has been made to an attribute bit, that attribute will be
  1405.    displayed as a capital letter instead of the normal, lower case display.
  1406.  
  1407.    You can also change an attribute for all files in the working directory
  1408.    with a single command.  Move the cursor to the column of the attribute you
  1409.    want to change (the line the cursor is on doesn't matter unless option /L
  1410.    is ON) and press [^y] or [^n].
  1411.  
  1412.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  22
  1413.  
  1414.  
  1415.  
  1416.    5.  Moving to a New Directory
  1417.  
  1418.    You can change EDDY's working directory and/or target directory at any
  1419.    time. These may be on the same or different disks.
  1420.  
  1421.  
  1422.    5.1 Dialog Boxes or Tree Diagrams -- Your Choice
  1423.  
  1424.    You have a choice of selecting directories from a graphical tree diagram or
  1425.    by text entry, using a dialog box.  The tree diagram is generally easier to
  1426.    use, but the dialog box is needed in certain situations, described below.
  1427.    Also, there is a delay associated with the tree diagram the first time a
  1428.    disk is accessed (or each time, on a floppy).
  1429.  
  1430.    The dialog box entry method is needed if you want to change the file
  1431.    specification used to select files for inclusion in the working directory
  1432.    display (e.g., you want to use "*.CPP" rather than "*.*").  It is also
  1433.    needed if you want to create a new directory for use as the target.
  1434.  
  1435.    5.1.1 How to Choose
  1436.  
  1437.    To choose a new working or target directory, press [Alt+w] or [Alt+t],
  1438.    respectively.  [Alt+w] and [Alt+t] work identically, except for the
  1439.    directory they work with.  For the remainder of this section (5.1.1), any
  1440.    reference to [Alt+w] and working directory also applies to [Alt+t] and
  1441.    target directory.
  1442.  
  1443.    The first time you press [Alt+w], you'll see the dialog box for entry of a
  1444.    new working directory.  Press [Alt+w] while this box is displayed, and EDDY
  1445.    will switch to the tree diagram for working directory selection.
  1446.  
  1447.    Once you have requested the tree diagram, it will be considered your first
  1448.    choice for working directory selection.  Anytime you press [Alt+w] from the
  1449.    EDIT mode display, you will see the tree display, not the dialog box.
  1450.  
  1451.    If you want to switch your choice back to the dialog box, press [Alt+w]
  1452.    while the tree diagram is displayed.
  1453.  
  1454.    [Alt+w] may be toggled in this way as often as you wish.  If you customize
  1455.    your copy of EDDY (see Section 25), the default action for [Alt+w] will be
  1456.    set to the action (tree or box) in effect when you customize.
  1457.  
  1458.    You may also choose to use the dialog box anytime you want, regardless of
  1459.    the action setting for [Alt+w]; if you press [Shift] at the same time --
  1460.    i.e., [Alt+Shift+w] -- the dialog box will always be displayed.  This does
  1461.    not affect the action setting for [Alt+w].
  1462.  
  1463.    REMEMBER: All references to [Alt+w] also apply to [Alt+t].
  1464.  
  1465.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  23
  1466.  
  1467.  
  1468.  
  1469.    5.1.2 Performance Considerations
  1470.  
  1471.    When EDDY scans a drive to determine the tree structure, you may save the
  1472.    scanned data in a file for later use (by pressing [F5]).  This has the
  1473.    advantage of faster display creation, but may be inaccurate if you have
  1474.    made changes to the directory structure since the file was created.
  1475.  
  1476.    a. Memory is Always Up-to-Date
  1477.  
  1478.    EDDY maintains the tree structure information for up to two drives in
  1479.    memory.  If a third drive's tree is requested, one of the memory areas will
  1480.    be reused, and any later access to the previous drive's tree will incur the
  1481.    initial delay again.
  1482.  
  1483.    If a tree data memory area is needed to be reused, an area associated with
  1484.    a floppy drive will be selected if possible.  This minimizes extra delays,
  1485.    as the tree data for floppy disks is refreshed with every reference anyway.
  1486.  
  1487.    If you use the DOS Gateway or Point-n-Shoot functions, EDDY has no way of
  1488.    knowing what changes may have been made.  Therefore, the tree information
  1489.    will be refreshed the next time the tree diagram is requested, and so
  1490.    you'll experience the delay again in this case, too.  Also, if you change
  1491.    the tree by creating new (target) directories, or by renaming, moving or
  1492.    deleting directories, the tree information must be refreshed.
  1493.  
  1494.    The maximum number of directories which EDDY can handle for one disk drive
  1495.    is difficult to specify, as it depends on how long the directory names are
  1496.    -- shorter names take less space.  However, if your drive has all 12-byte
  1497.    directory names (ffffffff.eee), 480 of them can be accommodated.
  1498.  
  1499.    The tree data may also be overwritten if you call on functions that need
  1500.    more memory, and the only way to get it is to use the memory where the tree
  1501.    data is stored.  Functions that MAY produce this condition are:  LOOK,
  1502.    UPDATE, HELP, and MENUs.
  1503.  
  1504.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  24
  1505.  
  1506.  
  1507.  
  1508.    b. Save a Tree - [F5]
  1509.  
  1510.    If you have directories that don't change very often, you may want to save
  1511.    the tree data in a file.  Then, on subsequent tree displays, the data from
  1512.    the file will be used, saving the normal scanning delay.
  1513.  
  1514.    Press [F5] while the tree diagram is displayed to save the data.  It will
  1515.    be saved in a file called "EDDYTREE.{x}", where "x" is the drive ID letter.
  1516.    This file will be stored in the root directory of the drive involved.  If
  1517.    you press [F5] again later, the file will be overwritten by the new data.
  1518.  
  1519.    When you request the tree diagram, the data from EDDYTREE.{x} will always
  1520.    be used to create the display if the file exists (and has not been
  1521.    corrupted).  If the display is built from the file, you'll see
  1522.    "EDDYTREE.{x}" at the lower left corner of the screen; if it's not there,
  1523.    the diagram was built by scanning the tree structure.
  1524.  
  1525.    If you suspect that the tree data from the file might be out-of-date, you
  1526.    may refresh the display (a new tree structure scan) by pressing [^x], where
  1527.    "x" is the drive ID letter of the currently-displayed drive.
  1528.  
  1529.    Note that refreshing the displayed tree by pressing [^x] does NOT update
  1530.    the tree data file automatically.  Except when EDDY finds an
  1531.    already-existing, but out-of-date version of EDDYTREE.{x}, the file is
  1532.    updated only when you request it explicitly, by pressing [F5].
  1533.  
  1534.    If EDDY finds that the tree file is out-of-date (e.g., tree file doesn't
  1535.    include the current directory), it will be rebuilt, and automatically
  1536.    updated on your disk.  Since the file was on your disk already, EDDY
  1537.    assumes you still want it.
  1538.  
  1539.  
  1540.    5.2 Directory Selection via Dialog Box
  1541.  
  1542.    To request the dialog box for entering working or target directories, press
  1543.    [Alt+Shift+w] or [Alt+Shift+t], respectively.
  1544.  
  1545.    You may specify the full path including drive and/or root, or a partial
  1546.    path that EDDY will interpret relative to the current working or target
  1547.    directory, as appropriate.  If your entry includes a drive and root (e.g.,
  1548.    "C:\WORK"), EDDY will use the specification exactly as you enter it.
  1549.  
  1550.    If you enter only a drive (e.g., "C:"), the default directory for that
  1551.    drive will become the new (working or target) directory.  If the current
  1552.    default is not the root, it will be displayed before it is used.
  1553.  
  1554.    When typing a path, you may use [Ins] and [Del] to make changes to it.
  1555.  
  1556.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  25
  1557.  
  1558.  
  1559.  
  1560.    5.2.1 Working Directory Dialog Box - [Alt+Shift+w] / [Alt+w]
  1561.  
  1562.    The working directory may be changed by pressing [Alt+Shift+w] (or [Alt+w],
  1563.    if that key is set to request the dialog box) and entering the new path,
  1564.    according to the rules described in the preceding paragraph.
  1565.  
  1566.    A file specification may also be entered, either with or without a path.
  1567.    If you enter only a file specification (e.g., "*.BAT"), that file
  1568.    specification will be used with the current working directory.
  1569.  
  1570.    EDDY tries to use your specification as a path.  If no such path can be
  1571.    found, what you have entered is used as a file specification.
  1572.  
  1573.    If you start the name with a "\", EDDY interprets this as a directory path
  1574.    starting from the root of the current working directory's drive.  If
  1575.    there's no initial "\", EDDY appends the name you provide to the end of the
  1576.    current working directory path string, and uses that as the new directory.
  1577.  
  1578.    For example:  suppose your current working directory is C:\UTIL and the DOS
  1579.    default on drive D:  is D:\WORK.  After pressing [Alt+w], if you type...
  1580.           "\" or ".." the new working directory will be C:\
  1581.           "\FOO" the new   working directory will be C:\FOO
  1582.           "FOO" (or "C:FOO") the new working directory will be C:\UTIL\FOO
  1583.           "D:" the new working directory will be D:\WORK
  1584.           "D:FOO" the new working directory will be D:\WORK\FOO
  1585.  
  1586.    Also see Section 5.7 if you work with "SUBST"ed drives.
  1587.  
  1588.    If you change your working directory to the same as your target directory,
  1589.    the target directory specification in EDDY will be set to "no target".  If
  1590.    you then enter a COPY or MOVE command, EDDY will ask you for a new target.
  1591.  
  1592.    For other ways to change directories, see Sections 5.4 (Exchange Working &
  1593.    Target Directories), 5.6 (Where's That File?) and 8.1 (LOOK at Directory).
  1594.  
  1595.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  26
  1596.  
  1597.  
  1598.  
  1599.    5.2.2 Target Directory Dialog Box - [Alt+Shift+t] / [Alt+t]
  1600.  
  1601.    The target directory may be changed by pressing [Alt+Shift+t] (or [Alt+t],
  1602.    if that key is set to request the dialog box).  EDDY will display the
  1603.    current drive and path (or tell you that there is no current target) and
  1604.    allow you to change the target directory if you wish.
  1605.  
  1606.    If you don't want to enter a new target directory after pressing
  1607.    [Alt+Shift+t], press [Esc].  The target directory will remain unchanged.
  1608.  
  1609.    No file specification may be used in the target directory path
  1610.    specification; only a drive and path are allowed.  The target directory
  1611.    cannot be set the same as the working directory.
  1612.  
  1613.    Partial path specifications are interpreted exactly as described above, for
  1614.    working directories, if there is no current target.  If there is a target,
  1615.    partial paths are interpreted relative to it.
  1616.  
  1617.    If you start the name with a "\", EDDY interprets this as a directory path
  1618.    starting from the root of the current target directory's drive.  If there's
  1619.    no initial "\", EDDY appends the name you provide to the end of the current
  1620.    target directory path string, and uses that as the new directory.
  1621.  
  1622.    For example:  suppose your current target directory is C:\TGT and the DOS
  1623.    default on drive D:  is D:\EASY.  Then, after pressing [Alt+Shift+t], if
  1624.    you type...  "\" or ".." the new target directory will be C:\ "\MONEY" the
  1625.    new target directory will be C:\MONEY "MONEY" (or "C:MONEY") the new target
  1626.    directory will be C:\TGT\MONEY "D:" the new target directory will be
  1627.    D:\EASY "D:MONEY" the new target directory will be D:\EASY\MONEY .
  1628.  
  1629.    If you enter a target directory name that doesn't exist after pressing
  1630.    [Alt+Shift+t] or [Alt+x], EDDY will normally ask if you want to create a
  1631.    new directory.  However, if any parts of the path preceding the name of the
  1632.    directory are also invalid, you will just get an error message.
  1633.  
  1634.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  27
  1635.  
  1636.  
  1637.    5.3 Directory Selection from Tree Diagram
  1638.  
  1639.    To request the tree diagram for the working directory's drive, press
  1640.    [Alt+w]; for the target directory's drive, [Alt+t].  If you get the dialog
  1641.    box display, press [Alt+w] or [Alt+t], respectively, again.
  1642.  
  1643.    5.3.1 Tree Display Format
  1644.  
  1645.    In the tree diagram, four types of directories are distinguished:
  1646.  
  1647.         - The current DOS default directory is shown in "braces", like {THIS}.
  1648.  
  1649.         - The working directory is shown enclosed in the special "double
  1650.           angle-brackets" characters, and looks something like <<THIS>>.
  1651.  
  1652.         - The target directory has solid triangle characters pointing to it on
  1653.           either side.  These characters are unprintable on many printers, and
  1654.           are not shown here.  They will be obvious in the display.
  1655.  
  1656.         - Other directories have no special characters enclosing them.
  1657.  
  1658.    The working/target directory will be highlighted when the tree is
  1659.    displayed.  To select a new directory, move the highlight to it and press
  1660.    [Enter] (or left-click the mouse).
  1661.  
  1662.    5.3.2 Moving the Tree Highlight (Speed Search)
  1663.  
  1664.    The highlight may be moved with the mouse, the cursor keys, or by using the
  1665.    "speed search" feature.
  1666.  
  1667.    The mouse and cursor keys work generally as you'd expect.  However, note
  1668.    that a [Right] arrow or mouse move always moves to the next directory in
  1669.    the tree.  Repetitions of [Right] will eventually visit every directory in
  1670.    the tree -- a complete "tree walk".  When the highlight is on the last
  1671.    directory in the tree, another [Right] will wrap back to the root.
  1672.  
  1673.    A [Left] arrow or mouse move goes to the parent of the currently
  1674.    highlighted directory.  Repeated [Left]s will quickly return to the root.
  1675.  
  1676.    You may also move the highlight by pressing keys corresponding to the
  1677.    directory name you want to select.  This is the speed search feature.
  1678.    Speed search works the same way it does for directory displays in EDIT
  1679.    mode, as described in Section 4.1.  (Except that option /F has no effect).
  1680.  
  1681.    A cursor within the highlight shows where the next character typed will be
  1682.    placed (just as in EDIT mode).  This cursor is not moved by using the
  1683.    cursor keys; they move the highlight, as described above.  The cursor moves
  1684.    right one column for each character typed.  Press [BackSpace] to move left.
  1685.  
  1686.    After positioning the highlight, press [Enter] to select a directory as the
  1687.    new work or target.  Alternatively, press [Alt+F10].  [Alt+F10] tells EDDY
  1688.    to terminate, leaving the selected drive/directory as the new DOS default.
  1689.  
  1690.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  28
  1691.  
  1692.  
  1693.  
  1694.    5.3.3 Moving to a New Drive - [^letter] / [^\]
  1695.  
  1696.    If you press [^\], you'll get a list of valid drives to choose from.
  1697.    Either press a letter from the list, or move the cursor to the desired
  1698.    drive letter and then [Enter] or left-click.  [^\] may be used in from EDIT
  1699.    mode, or while the dialog box is displayed, or from the tree diagram.
  1700.  
  1701.    While the tree diagram is displayed, diagrams for other drives may be
  1702.    displayed by pressing [Ctrl] and the drive letter identifier; e.g., to get
  1703.    the tree display for drive C:, press [^c].
  1704.  
  1705.    You may also go directly to the tree diagram for any valid drive from the
  1706.    dialog box.  If you press [^letter] while the working directory dialog box
  1707.    is on-screen, the action is just as though you had pressed [Alt+w],
  1708.    followed immediately by [^letter].  That is, you'll get the tree display
  1709.    for the drive, and any subsequent use of [Alt+w] from EDIT mode will yield
  1710.    the tree display rather than the dialog box.  [^letter] pressed while the
  1711.    target directory dialog box is on-screen works similarly.
  1712.  
  1713.    5.3.4 Working Directory Tree - [Alt+w]
  1714.  
  1715.    With the tree diagram displayed, move the highlight to the desired
  1716.    directory name and press [Enter] (or left-click).  The highlighted
  1717.    directory will become the new working directory.
  1718.  
  1719.    If you change your working directory to the same as your target directory,
  1720.    the target directory specification in EDDY will be set to "no target".  If
  1721.    you then enter a COPY or MOVE command, EDDY will ask you for a new target.
  1722.  
  1723.    When you display the tree diagram for the working directory's drive, you
  1724.    will not see the current DOS default directory enclosed in "{ }".  This is
  1725.    because the current directory is always the same as the working directory
  1726.    while EDDY is in control.
  1727.  
  1728.    If you display the tree for another drive (e.g., by pressing [^c]) you will
  1729.    see the current directory on that drive.  If the working directory is on a
  1730.    SUBST'ed drive which is part of the new drive's tree structure, both the
  1731.    {CURRENT} and <<WORKING>> directories will be indicated.
  1732.  
  1733.    5.3.5 Target Directory Tree - [Alt+t]
  1734.  
  1735.    With the tree diagram displayed, move the highlight to the desired
  1736.    directory name and press [Enter] (or left-click).  The highlighted
  1737.    directory will become the new target directory.
  1738.  
  1739.    You may not select a target directory the same as the working directory.
  1740.  
  1741.    If you press [Alt+t] with no target directory previously selected, the tree
  1742.    diagram for the working directory will be displayed.
  1743.  
  1744.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  29
  1745.  
  1746.  
  1747.  
  1748.    5.4 Exchange Working & Target Directories - [Alt+x]
  1749.  
  1750.    To exchange the current working and target directories, press [Alt+x] (This
  1751.    turns off option /W if it is on -- see Section 5.6).  When you exchange,
  1752.    EDDY will "remember" your current file, and will return the cursor to that
  1753.    file if you later exchange back (with no intervening changes of directory).
  1754.  
  1755.    5.5 Directory Recall - [Shift+F10], [Shift+^F10]
  1756.  
  1757.    Directory recall may be set for the current working directory by pressing
  1758.    [Shift+F10].  This directory may later be "recalled" as the working
  1759.    directory by pressing [Shift+^F10].  See Section 15.1 for more information
  1760.    on using directory recall.
  1761.  
  1762.    5.6 Where's That File?  - Option /W and [^w]
  1763.  
  1764.    To find the directory (or directories) a file is in, use option /W from the
  1765.    command line and/or the [^w] command within EDDY.
  1766.  
  1767.    For example, enter:  EDDY/W C:\FOO*.* to search drive "C:" for any
  1768.    directory that has a filename beginning with "FOO" in it, with any
  1769.    extension.  If a directory is found that contains such a file, that
  1770.    directory will be set as the working directory.  Press [^w] to find the
  1771.    next such directory, if any.
  1772.  
  1773.    If you enter:  EDDY/W ">06/15/91", EDDY will search the directory tree
  1774.    starting from the current directory, and will stop when a file is found
  1775.    that was created after the indicated date (see "Filtering by Timestamp").
  1776.  
  1777.    From the command line, using option /W causes EDDY to search the disk for
  1778.    matching files, starting with the given working directory and continuing
  1779.    downward in the directory tree.  The directories are searched in "unsorted"
  1780.    sequence; i.e., the order they actually are stored on your disk.  The
  1781.    working directory which will be displayed is the first one found which has
  1782.    matching files.  If there is no match, you'll get "File not found".
  1783.  
  1784.    Pressing [^w] when option /W is off turns /W on, and EDDY then searches
  1785.    from the current directory downward in the tree for a directory with one or
  1786.    more files matching the current file, attribute and/or timestamp
  1787.    specifications.  If found, that directory becomes the new working
  1788.    directory.  If there are no matches, you'll get "File not found", and /W
  1789.    will be turned off.
  1790.  
  1791.    Pressing [^w] when option /W is on causes EDDY to search the directory tree
  1792.    for the next directory, relative to the directory which was current when
  1793.    you first pressed [^w], which contains matching files.  Using [^w] again
  1794.    will display the next directory, if any, which has matching files.
  1795.  
  1796.    Explicitly changing working directory (by using [F3], [Alt+w],
  1797.    [Alt+Shift+w] or [Alt+x]) will turn off option /W.
  1798.  
  1799.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  30
  1800.  
  1801.  
  1802.  
  1803.    5.7 Working With "SUBST"ed Directories
  1804.  
  1805.    EDDY can switch freely between SUBST'ed drives and subdirectories and their
  1806.    un-SUBST'ed, fully expanded path equivalents.
  1807.  
  1808.    5.7.1 From the Command Line
  1809.  
  1810.    Suppose your current DOS default drive is actually SUBST'ed, and you are in
  1811.    the highest level directory of that SUBST'ed drive (i.e., what is
  1812.    effectively the "root" directory for that drive).  In this case, if you
  1813.    specify either the working or target directory as "..", the true drive and
  1814.    path will be used.
  1815.  
  1816.    For example, if you earlier used the DOS command "SUBST X:  C:\FOO\BAR" and
  1817.    your current default drive is "X:", using ".." will be interpreted by EDDY
  1818.    as "C:\FOO".  If your current default is "X:\WORK", EDDY would interpret
  1819.    ".." the same way DOS does -- i.e., "X:\".
  1820.  
  1821.    5.7.2 Interactively
  1822.  
  1823.    Once EDDY is executing, if you change directories as described in Sections
  1824.    5.1 - 5.4, or by using [F3] as described in Section 8.1, you have even more
  1825.    flexibility with SUBST'ed drives.
  1826.  
  1827.    Using ".." works the same as it does on the command line, as described in
  1828.    the preceding section.
  1829.  
  1830.    However, "." used from within EDDY is interpreted as the un-SUBST'ed, fully
  1831.    expanded path string.  Thus, using the example in the preceding section, if
  1832.    your current working directory is "X:\WORK" and you use ".", EDDY will
  1833.    interpret this as "C:\FOO\BAR\WORK".
  1834.  
  1835.    This is only a change in the way the directory is referenced; it is the
  1836.    same physical directory no matter which string is used to refer to it.
  1837.    Therefore, the display of files, bytes used, etc., will not be affected.
  1838.  
  1839.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  31
  1840.  
  1841.  
  1842.    6.  HELP When You Need It - [F1]
  1843.  
  1844.    When you have a choice to make as to how you want EDDY to proceed, you can
  1845.    get relevant HELP information by pressing [F1].  The HELP screen you get
  1846.    will be different, depending on what you were doing when you pressed [F1].
  1847.  
  1848.    Once you are in HELP mode, you may view other HELP screens.  Pressing [F1]
  1849.    while in HELP displays the menu of available topics.  You may select from
  1850.    the menu, or press [PgUp] or [PgDn] to view the screens sequentially.
  1851.  
  1852.    For the HELP function to operate, EDDY must be able to find the file
  1853.    "EDDY.AUX".  EDDY can find it in any of the following directories:
  1854.  
  1855.    - A directory which is mentioned in your DOS PATH statement
  1856.    - The current working directory
  1857.    - The directory you executed EDDY from (if you have DOS 3.0 or higher)
  1858.  
  1859.    The initial HELP display, which appears when you type just "EDDY" with
  1860.    nothing else on the command line, is disabled when you use a customized
  1861.    copy of EDDY (see Section 25).  However, if EDDY finds he's running a
  1862.    customized copy on a machine that appears to be different from the one
  1863.    where the customizing was done, the initial HELP is re-enabled.
  1864.  
  1865.    EDDY loads the HELP module from EDDY.AUX when you press [F1], if there is
  1866.    enough memory available (around 60K).
  1867.  
  1868.    The HELP screens and menus have their own color attributes, not tied to
  1869.    those used for other EDDY screens (but HELP colors are the same as menu
  1870.    colors).  These colors may be customized as desired (see Section 25.2).
  1871.  
  1872.    6.1 HELP for Warnings and Other Messages
  1873.  
  1874.    Most of EDDY's messages can readily be understood from their wording and
  1875.    context.  For those that seem worthy of a bit more explanation, however,
  1876.    Appendix B of this document offers further information.  When there is more
  1877.    information provided in Appendix B, a message to that effect will appear
  1878.    beneath the warning or error message.
  1879.  
  1880.  
  1881.    7.  UNDO Command - [F2], [^F2]
  1882.  
  1883.    Any changes requested may be "Undone" as long as they have not yet been
  1884.    written to disk by entering UPDATE mode.  To undo changes on the current
  1885.    file, press [F2].  To undo all changes for all files, press [^F2].
  1886.  
  1887.    7.1 Partial UNDO
  1888.  
  1889.    You may UNDO the COPY, MOVE, DELETE and DESTROY commands without affecting
  1890.    other changes pending for the file.  Just press the key for the same
  1891.    command again; i.e., if a file is tagged for COPY, and you decide not to
  1892.    COPY, press [F5] and the tag will disappear, but other changes will remain.
  1893.  
  1894.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  32
  1895.  
  1896.  
  1897.  
  1898.    8.  LOOK Command - [F3], [^F3]
  1899.  
  1900.    LOOK has three variations, depending upon where the cursor is.  If the
  1901.    current line has a subdirectory, the request is interpreted as "display the
  1902.    contents of this subdirectory".  For normal files, LOOK means "display the
  1903.    contents of this file".  If the "Drive X:  is..." heading line is under the
  1904.    cursor, LOOK means "treat the entire disk as a file, and display it".
  1905.  
  1906.  
  1907.    8.1 LOOK at Subdirectory
  1908.  
  1909.    When you LOOK at a subdirectory, you change EDDY's working directory.  To
  1910.    do this, move the cursor to the display line of the directory you want to
  1911.    LOOK at and press [F3].  Changing directories with [F3] turns off option /W
  1912.    if it is on. For other ways to change the working directory, see Section 5.
  1913.  
  1914.    Figure 8-1 might have been reached from the display in Figure 1-1, as
  1915.    follows:  1) turn on option /R, to get " memory" in the display; 2) move
  1916.    cursor to the subdirectory "EDDY", and press [F3]; 3) in the resulting
  1917.    display (not shown), move cursor to "MACROS" line and press [F3] again.
  1918.  
  1919. ================================================================================
  1920. filename.ext    size  mmddyy    time    RHYDAS                                 ^
  1921. DIR of A:\EDDY\MACROS\*.*                                                      |
  1922. Drive A: is EDDY                     7 files,   7168 bytes      2048 bytes free|
  1923.                                                                                |
  1924. .            <DIR>   11-16-86  8:45:00a nnnynn             |======|            |
  1925. ..           <DIR>    1-25-87 12:52:02p nnnynn             | MENU |            |
  1926. DOS      MAC     319  8-25-86  8:43:36p nnnnyn             |======|            |
  1927. KEYBD    MAC     621  1-21-87  1:15:14a nnnnyn             [Alt+F1]            |
  1928. MISC     MAC    1607  1-21-87  3:49:18p nnnnyn                                 |
  1929. OPCODES  MAC    1448  2-04-87  7:54:22p nnnnyn             |======|            |
  1930. VIDEO    MAC     711  1-21-87  1:38:47d nnnnyn             | HELP |            |
  1931.  memory       655360  7-11-88  8:55:00p                    |======|            |
  1932.                                                              [F1]              |
  1933.         .
  1934.         .
  1935.         .
  1936.                                                                                |
  1937. -EDIT- seq=N  [F2]:UNDO  [F3]:LOOK  [F5]:COPY  [F6]:MOVE  [F7]:DELETE  [F9]:DOSv
  1938. ================================================================================
  1939.  
  1940.                                   Figure 8-1
  1941.  
  1942.    To go to the parent directory of the working directory, move the cursor to
  1943.    the line containing ".." and press [F3].  In our example, this would get
  1944.    the display of "A:\EDDY\*.*".  To return to the display of Figure 1-1, use
  1945.    [F3] on the ".." line again.
  1946.  
  1947.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  33
  1948.  
  1949.  
  1950.  
  1951.    Using [F3] to change directories turns off option /W if it is on.
  1952.  
  1953.    If you move to a new working directory with changes pending (renames,
  1954.    copies, etc., which have not been through an UPDATE), the changes will be
  1955.    discarded -- in effect, Undone.  If there are pending changes, EDDY will
  1956.    warn you and ask for confirmation before moving to the new directory.
  1957.  
  1958.    Also see Section 5.7 if you work with "SUBST"ed drives.
  1959.  
  1960.    If there are no changes pending, pressing [Enter] will have the same effect
  1961.    as pressing [F3] if you are positioned on a file, directory or "drive"
  1962.    entry in the display; i.e., you will LOOK at that entry.  On other display
  1963.    lines, you'll get the usual "Nothing to update" message.  [Enter] always
  1964.    initiates an UPDATE if changes are pending, or if you are customizing EDDY.
  1965.  
  1966.    Note that the third box on the right side of the screen shows "LOOK" as the
  1967.    action corresponding to [Enter] if there are no changes pending; if there
  1968.    are, the box says "UPDATE".
  1969.  
  1970.    If you don't like the use of [Enter] as an alternate way to LOOK, see
  1971.    Section 25.3.4.
  1972.  
  1973.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  34
  1974.  
  1975.  
  1976.  
  1977.    8.2 LOOK at File Contents (in Working Directory)
  1978.  
  1979.    To LOOK at the data contained in the current file, press [F3].  [^F3] LOOKs
  1980.    at the data in ALL files in the directory, one at a time.  Pressing [Esc],
  1981.    or pressing [F3] a second time, returns you to EDIT mode.
  1982.  
  1983.    8.2.1 LOOK Mode Commands
  1984.  
  1985.    a. Hex/ASCII Format Control - [Tab], [Shift+Tab]
  1986.  
  1987.    EDDY uses the first 512 bytes in a file to decide how to display the data
  1988.    (hex or ASCII format).  ASCII is used if at least 80% of the first 512
  1989.    bytes are printable (20h - 7Eh), formatting control characters -- CR, LF,
  1990.    FF, TAB -- or line/box-drawing characters.  Otherwise, hex format is used.
  1991.  
  1992.    [Tab] toggles between ASCII and hex display formats.  If you don't like
  1993.    that key, press [Shift+Tab].  EDDY will ask you to press the key you want
  1994.    to use as a toggle.  Any function key or [Alt]-shifted key that doesn't
  1995.    conflict with other LOOK, PATCH or FIND usage is OK.  E.g., [F5] and [F12]
  1996.    are OK, but [F1] (the "HELP" key) is not; [Alt+h] is OK, but [Alt+b] (used
  1997.    for bit-stripping) isn't.  If [Tab] is not used to toggle, it may be used
  1998.    in PATCH and FIND to enter TAB characters (see Sections 9 and 16).
  1999.  
  2000.    b. Printing a File - [Alt+p]
  2001.  
  2002.    Pressing [Alt+p] prints the current file.  Printing begins with the line at
  2003.    the top of the screen, and continues until a key is pressed.  With a
  2004.    non-ASCII file, it's probably a good idea to ensure it's "printable", by
  2005.    pressing [p] before [Alt+p].  See Section 8.2.5a for more on this.
  2006.  
  2007.    Pressing [Alt+Shift+p] sends a formfeed to the printer, but doesn't print.
  2008.  
  2009.    c. EGA/VGA Screen Control - [e]
  2010.  
  2011.    If you have an EGA (or VGA) monitor, you may switch between 25 lines per
  2012.    screen and 43 (or 50) lines by pressing [e].  This is the same as turning
  2013.    option /E ON or OFF (see Section 2.3).
  2014.  
  2015.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  35
  2016.  
  2017.  
  2018.  
  2019.    8.2.2 ASCII Format Display
  2020.  
  2021.    In ASCII format, a new line is initiated when either a CR or LF is
  2022.    encountered (but a CRLF pair only counts as one line).  The line number of
  2023.    the line at the top of the screen is shown on the status line at the bottom
  2024.    of the screen.  The highest line number EDDY can display is 65535.
  2025.  
  2026.    The "arrow" (and related) keys work a little differently in LOOK mode.  The
  2027.    display may be thought of as a "window" which can be moved around to view
  2028.    various parts of a file, while the file itself does not move.
  2029.  
  2030.    The keys used to move the display window around in ASCII format are:
  2031.  
  2032.     [Up]        - move up 1 line         [Down]   - move down 1 line
  2033.     [PgUp]      - move up 1 page         [PgDn]   - down 1 page
  2034.     [^Home]     - first page             [^End]   - last page
  2035.     [Left]      - left 1 column          [Right]  - right 1 column
  2036.     [Shift+t] ([T]) - tab left 20 columns  [t]    - tab right 20 columns
  2037.     [^Left]     - left edge (col. 1)     [^Right] - right edge (last column)
  2038.     [Home]      - same as [^Left]        [End]    - same as [^Right]
  2039.     [^PgDn]     - auto-scroll down       [^PgUp]  - auto-scroll up
  2040.  
  2041.    [PgUp] and [PgDn] move a screen at a time, overlapping the previous screen
  2042.    by one line.  When paging in ASCII format through a long non-text file,
  2043.    EDDY may spend a lot of time looking for CRs and LFs that aren't there.  If
  2044.    EDDY appears to be "hung up" after a [PgUp] or [PgDn], press [^c] or
  2045.    [BackSpace] to interrupt the processing and display the file from wherever
  2046.    EDDY has reached, and no further processing will take place.
  2047.  
  2048.    If you just want to pause temporarily, to look at the screen or think about
  2049.    what's going on, press and hold [ScrollLock].  All processing will stop.
  2050.    Release the key to continue.  s read to thus far.
  2051.  
  2052.    The effect of the [Up] and [Down] keys in LOOK mode may be modified by
  2053.    pressing [s].  [s] toggles these keys between their normal scrolling speed
  2054.    of one-line-per-keypress and half-page-per-keypress ("speed scrolling").  A
  2055.    half page is defined by the number of text lines in the display, not the
  2056.    physical lines available on your screen.  Thus, the speed of scrolling will
  2057.    vary, depending on the data you're LOOKing at.
  2058.  
  2059.    Speed scrolling is of limited value unless you're using a mouse.  With a
  2060.    mouse, it gives a faster way of scrolling, without requiring use of the
  2061.    keyboard to press [PgUp]/[PgDn].
  2062.  
  2063.    Auto-scroll moves the display up or down continuously, without further key
  2064.    presses.  It is started by [^PgDn] or [^PgUp].  Pressing the same key again
  2065.    speeds up the scrolling; pressing the opposite one slows it down.  Any
  2066.    other key stops auto-scroll.
  2067.  
  2068.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  36
  2069.  
  2070.  
  2071.  
  2072.    8.2.3 ASCII Format Commands
  2073.  
  2074.    a.  TAB Expansion - [0] thru [8] / [Alt+0] thru [Alt+8]
  2075.  
  2076.    TABs expand to 8-character boundaries as a default.  You may change the TAB
  2077.    expansion by pressing [0], [1],...,[8].  TABs will then expand to the
  2078.    boundary you have selected.  If you press [0], TAB characters will be shown
  2079.    as "blobs" on the screen, and no expansion will be done.
  2080.  
  2081.    The default setting is used with each new entry to LOOK.  You can change
  2082.    the default setting by pressing [Alt+0], [Alt+1],...,[Alt+8].
  2083.  
  2084.    The current TAB expansion factor is shown at the bottom of the screen.  If
  2085.    this is also the default, it will be indicated by an "=" (e.g., "tab=8");
  2086.    if it is a temporary setting, a ":" will be used (e.g., "tab:4").
  2087.  
  2088.  
  2089.    b.  Bit Stripping - [b] / [Alt+b]
  2090.  
  2091.    With files that have lots of high-order bits set (e.g., WordStar) to
  2092.    obscure the real meanings of the characters, try bit-stripping.  Pressing
  2093.    [b] causes EDDY to clear the high-order bit before the characters are
  2094.    displayed.  Press [b] again to toggle the bit-stripping action.
  2095.  
  2096.    Bit-stripping is normally OFF when you enter LOOK mode, and "bits=8" will
  2097.    be shown on the bottom line.  The "=" means the displayed value is the
  2098.    default, which will be reset at each entry to LOOK.  If you press [b], you
  2099.    will see the display "bits:7".  This means that only the low-order 7 bits
  2100.    are used from each byte for building the display, and the ":" indicates
  2101.    that this is a temporary state, in effect only until you exit LOOK mode.
  2102.  
  2103.    To change the default state for bit-stripping, press [Alt+b].
  2104.  
  2105.    If you use [b] (or [Alt+b]) after the first line of the file, EDDY loses
  2106.    track of the line number.  To indicate this, the bottom line shows
  2107.    "line:?".  Returning to the top of the file restores the line number
  2108.    synchronization.
  2109.  
  2110.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  37
  2111.  
  2112.  
  2113.  
  2114.    c.  Ruler Line Display - [r] / [u] / [d]
  2115.  
  2116.    To determine what position a particular character in the display occupies
  2117.    in its line, press [r].  You will see a line similar to this one:
  2118.  
  2119.    21 ++++++^+++++++++^+++++++++^+++++++++^+++++++++^+++++++++^+++++++++^+++++
  2120.  
  2121.    The number at the left is the column number in the file of the character
  2122.    shown in column 1 of the screen.  The "^" characters mark the columns which
  2123.    are even multiples of 10 in the FILE (not necessarily the same as columns
  2124.    on the screen).  In this example, which is what you might see after a [t],
  2125.    the "^"s mark columns 30, 40, etc.
  2126.  
  2127.    The ruler is moved up or down by pressing [u] or [d], respectively.
  2128.  
  2129.  
  2130.    d.  Jump to New Line - [j]
  2131.  
  2132.    You may move directly to any line in the file by pressing [j], and then
  2133.    typing the line number you are interested in.  If you type a number larger
  2134.    than any in the file, you'll get a display of the last few lines.
  2135.  
  2136.    After pressing [j], you'll see a field of 5 zeros, where you may enter the
  2137.    line number to which you want to jump.  The cursor starts in the second
  2138.    digit of this field, on the assumption that line numbers entered will most
  2139.    frequently be 9999 or less.  However, you may use all 5 positions if
  2140.    needed.  Line numbers larger than 65,535 are not supported.
  2141.  
  2142.  
  2143.    e.  Line Wrapping - [l] / [Alt+l]
  2144.  
  2145.    Line wrapping means all lines are "broken" if they are longer than 80
  2146.    characters, with the remainder appearing on the next line of the screen.
  2147.    Thus, the whole line is visible on the screen at once.
  2148.  
  2149.    [l] is a toggle key which turns line wrapping alternately ON and OFF.  Line
  2150.    wrapping normally defaults to OFF on entering LOOK mode.  In this case, you
  2151.    would see the string "line=1" at the bottom of the display, which tells you
  2152.    that line wrapping is OFF (the first character is "l"), this is the default
  2153.    state for the toggle (the "=" sign) and we are at the first line of the
  2154.    file.  If you press [l] to turn line wrapping ON, a broken vertical line
  2155.    (the DOS "piping" symbol) replaces the "l" in "line", and the string
  2156.    displayed would be "|ine:1".  The ":" shows that ON is a temporary state.
  2157.  
  2158.    To change the default state for line-wrapping, press [Alt+l].
  2159.  
  2160.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  38
  2161.  
  2162.  
  2163.  
  2164.    Even though the lines are wrapped on the screen, EDDY still works with
  2165.    complete logical lines, as determined by the presence of CR/LF characters.
  2166.    When you move the display up or down, a line at a time or by paging, the
  2167.    display moves in units of complete logical lines.  The display will always
  2168.    begin at the start of a logical line (except in some cases when toggling
  2169.    between ASCII and hex formats).  Movement of the display up or down is
  2170.    based on the line at the top of the screen.
  2171.  
  2172.  
  2173.    8.2.4 Hex Format Display
  2174.  
  2175.    An example of a hex format display appears below (Figure 8-2).  The number
  2176.    under the heading "Offset" is the number of bytes from the start of the
  2177.    file, in hex.  Next comes the hex value of the data, followed by the
  2178.    equivalent characters, under the "ASCII" heading.
  2179.  
  2180. ================================================================================
  2181.  Offset    00 01 02 03 04 05 06 07-08 09 0A 0B 0C 0D 0E 0F          ASCII     P
  2182.  
  2183. 00000000   E9 ED 0E F5 01 9B 06 B3 A4 23 2A 38 6C 38 0B 1B     im.u...3$#*8l8..
  2184. 00000010   1E 1E 43 59 43 43 4E 00 00 00 00 00 00 00 46 09     ..CYCCN.......F.
  2185. 00000020   00 00 41 42 43 44 45 46 49 4B 4D 50 52 54 57 03     ..ABCDEFIKMPRTW.
  2186. 00000030   4E 06 00 00 3F 3F 3F 3F 3F 3F 3F 3F 3F 3F 3F 3F     N...????????????
  2187. 00000040   3F 3F 3F 3F 3F 3F 3F 3F 3F 3F 3F 3F 3F 3F 3F 3F     ????????????????
  2188. 00000050   3F 3F 3F 3F 3F 3F 3F 3F 3F 3F 3F 3F 3F 3F 3F 3F     ????????????????
  2189. 00000060   3F 3F 3F 3F 3F 3F 3F 3F 3F 3F 3F 3F 3F 3F 3F 3F     ????????????????
  2190. 00000070   3F 3F 3F 3F D5 CD CD CD CD CD CD CD CD CD CD CD     ????UMMMMMMMMMMM
  2191. 00000080   CD CD CD CD CD CD CD CD CD CD CD CD CD CD CD CD     MMMMMMMMMMMMMMMM
  2192. 00000090   CD CD B8 0A 24 B3 20 54 48 41 4E 4B 20 59 4F 55     MM8.$3 THANK YOU
  2193. 000000A0   20 66 6F 72 20 75 73 69 6E 67 20 45 44 44 59 28      for using EDDY(
  2194. 000000B0   74 6D 29 B3 0A 24 B3 20 20 20 20 20 20 20 20 20     tm)3.$3
  2195. 000000C0   76 65 72 73 69 6F 6E 20 35 2E 30 31 20 20 20 20     version 5.01
  2196. 000000D0   20 20 20 20 B3 0A 24 B3 20 20 20 43 6F 70 79 72         3.$3   Copyr
  2197. 000000E0   69 67 68 74 28 43 29 20 31 39 38 37 2C 38 38 2C     ight(C) 1987,88,
  2198. 000000F0   38 39 20 20 20 B3 0A 24 B3 20 62 79 20 4A 6F 68     89   3.$3 by Joh
  2199. 00000100   6E 20 53 63 6F 66 69 65 6C 64 2C 20 42 6F 78 20     n Scofield, Box
  2200. 00000110   34 37 31 33 36 20 B3 0A 24 B3 4D 6F 72 72 69 73     47136 3.$3Morris
  2201. 00000120   6F 6E 20 48 69 6C 6C 20 50 2E 4F 2E 2C 20 48 6F     on Hill P.O., Ho
  2202. 00000130   6E 67 20 4B 6F 6E 67 B3 0A 24 B3 20 20 20 20 20     ng Kong3.$3
  2203. 00000140   41 6C 6C 20 72 69 67 68 74 73 20 72 65 73 65 72     All rights reser
  2204.  
  2205. -LOOK-   EDDY.COM      bits=8  tab=8  line=1      [F1]:HELP  [Alt+F1]/click:MENU
  2206. ================================================================================
  2207.  
  2208.                                 Figure 8-2
  2209.  
  2210.    NOTE: If no mouse is present, there will be no reference to click on the
  2211.    bottom line.  See Section 2.1.2 for information on using EDDY with a mouse.
  2212.  
  2213.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  39
  2214.  
  2215.  
  2216.  
  2217.    8.2.5 Hex Format Commands
  2218.  
  2219.    The keys used in LOOK mode to move around in the hex-format display are:
  2220.  
  2221.     [Up]    - move up 1 line          [PgUp]  - up 1 page
  2222.     [Down]  - move down 1 line        [PgDn]  - down 1 page
  2223.     [^Home] - display first page      [^End]  - display last page
  2224.     [^PgDn] - auto-scroll down        [^PgUp] - auto-scroll up
  2225.  
  2226.    Additional commands are available in hex format are described below.
  2227.  
  2228.  
  2229.    a.  Printability - [p]
  2230.  
  2231.    Normally, the characters under the "ASCII" heading are the exact
  2232.    equivalents of the hex data.  However, many of the characters corresponding
  2233.    to the hex values in the ranges 00h -- 1Fh and 7Fh -- 9Fh are interpreted
  2234.    as printer commands by most printers.  An attempt to use the DOS
  2235.    [Shift]-[PrtSc] function on a screen containing these characters will
  2236.    result in an assortment of form feeds, font changes, carriage returns,
  2237.    etc., rather than the screen print desired.
  2238.  
  2239.    EDDY provides an option to accommodate screen printing of hex displays.  If
  2240.    you press [p], telling EDDY to format the screen for printing, the
  2241.    characters in the troublesome ranges will be replaced by periods, and all
  2242.    high-order bits will be turned off.  The hex data part of the display is
  2243.    unchanged.  When [p] is pressed, a blinking letter "P" appears at the right
  2244.    end of line 1 to remind you that "printability" is turned on.  [p] is a
  2245.    toggle key, and turns printability alternately on and off.
  2246.  
  2247.    The example in Figure 8-2 has printability selected.
  2248.  
  2249.  
  2250.    b.  Bit Stripping - [b] / [Alt+b]
  2251.  
  2252.    Bit stripping in hex format works as described in 8.2.3b, above, but
  2253.    affects only the ASCII portion of the display.  The actual character
  2254.    present in the file, with no bits stripped, is shown in the hex portion of
  2255.    the display.
  2256.  
  2257.    c.  Jump to New File Position - [j]
  2258.  
  2259.    You may move directly to any position in the file by pressing [j] and then
  2260.    typing the 8-digit hex offset which you are interested in.  If you type too
  2261.    large a value, you'll get a display of the last few lines of the file.
  2262.  
  2263.    If you jump with the display in hex format, EDDY loses track of the line
  2264.    number (but you get there faster).
  2265.  
  2266.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  40
  2267.  
  2268.  
  2269.  
  2270.    d.  Word-oriented Display - [w], [W]
  2271.  
  2272.    When LOOKing at a file in hex format, you may select the hex portion of the
  2273.    display to be in words (as opposed to the normal bytes) by pressing [w].
  2274.    If you want to see the words in inverted order (high-order byte first),
  2275.    press [W].  Press the same key again to return to the normal byte display.
  2276.  
  2277.    If you want the word display to start with the odd-numbered bytes, press
  2278.    [t].  Press [t] again to revert to even byte orientation.
  2279.  
  2280.    When displaying inverted words, the heading at the top of the display shows
  2281.    the inverted sequence of bytes.
  2282.  
  2283.  
  2284.    8.2.6 LOOK Mode With a Mouse
  2285.  
  2286.    In LOOK mode, ASCII (text) display format, a left click from anywhere calls
  2287.    up the menu.  In hex format, the otherwise unused area between the two
  2288.    parts of the display is indicated by arrows pointing from the bottom line;
  2289.    left click here to call the menu.
  2290.  
  2291.    When PATCHing, a left click anywhere except the indicated "click area"
  2292.    means "update" (same as [Enter]); a double left click means "update, don't
  2293.    change timestamp" (same as [^Enter]).
  2294.  
  2295.    A right click returns to EDIT from LOOK, or to LOOK from PATCH.
  2296.  
  2297.  
  2298.    8.3 LOOK at File Contents (in Target Directory) - [Alt+F3]
  2299.  
  2300.    To LOOK at the contents of a file in the target directory which has the
  2301.    same name as the current file, press [Alt+F3].  Remember, if the current
  2302.    file has been renamed, even though not yet UPDATEd, the NEW name will be
  2303.    used to decide which target file to LOOK at.  If there is no target
  2304.    directory, or there is no file with that name, you will be informed.
  2305.    Otherwise, you will see a display identical to that described above, and
  2306.    all the LOOK mode commands will work the same way.
  2307.  
  2308.    When the file displayed is from the target directory, a "T" is shown on the
  2309.    last line in column 7, thus:
  2310.  
  2311. . . .
  2312. 00000100   24 B3 20 20 20 43 6F 70 79 72 69 67 68 74 20 28     $|   Copyright (
  2313. 00000110   43 29 20 31 39 38 37 2C 31 39 38 38 20 20 20 B3     C) 1987,1988   |
  2314. 00000120   24 B3 20 62 79 20 4A 6F 68 6E 20 53 63 6F 66 69     $| by John Scofi
  2315. 00000130   65 6C 64 2C 20 42 6F 78 20 34 37 31 33 36 20 B3     eld, Box 47136 |
  2316. 00000140   24 B3 4D 6F 72 72 69 73 6F 6E 20 48 69 6C 6C 20     $|Morrison Hill
  2317.  
  2318. -LOOK-T  EDDY.COM      bits=8  tab=8  line=1       [F1]:HELP       [Alt+F1]:MENU
  2319. ================================================================================
  2320.  
  2321.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  41
  2322.  
  2323.  
  2324.  
  2325.    8.4 Compare Directory Entries - [Shift+F3], [Shift+^F3]
  2326.  
  2327.    To compare the directory entries of corresponding files in the working and
  2328.    target directories, press [Shift+F3].  If files have been renamed, even
  2329.    though not yet UPDATEd, the NEW name will be used for comparisons.
  2330.  
  2331.    Press [Ctrl], [Shift] and [F3] simultaneously to compare working and target
  2332.    directory entries (one at a time) of all files in the working directory.
  2333.    After each comparison, the result is displayed and EDDY waits for a key to
  2334.    be pressed before proceeding to the next comparison.
  2335.  
  2336.    [^c] or [BackSpace] terminates a [Shift+^F3].
  2337.  
  2338.  
  2339.    8.5 Compare Files - [Alt+Shift+F3]
  2340.  
  2341.    Press [Alt], [Shift] and [F3] simultaneously to compare the contents of the
  2342.    current file and the corresponding file (i.e., same filename) in the target
  2343.    directory.  If files have been renamed, even though not yet UPDATEd, the
  2344.    NEW name will be used for comparisons.
  2345.  
  2346.    EDDY will tell you whether the file contents are identical or not.  The
  2347.    offset in the file where bytes do not match (if any) will be displayed,
  2348.    along with the hex values of the bytes involved.
  2349.  
  2350.    If the files are different lengths, the comparison will still be done.
  2351.    This allows you to determine, for example, whether the files are identical
  2352.    at least up to the length of the shorter one.
  2353.  
  2354.    Successive [Alt+Shift+F3]'s on the same file tell you the next byte where a
  2355.    difference exists.  If there are no more differences, EDDY will tell you
  2356.    that.  (On files of different lengths, if the only difference is the extra
  2357.    bytes in the longer one, only the first difference will be reported.)
  2358.  
  2359.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  42
  2360.  
  2361.  
  2362.  
  2363.    8.6 LOOK at RAM (or ROM, or ???)
  2364.  
  2365.    You may LOOK at your PC's memory (if option /R is ON) by moving to the "
  2366.    memory" entry and then pressing [F3].  RAM contents will be displayed in
  2367.    hex format, from 0000:0000 up to the limit of installed RAM.  EDDY bases
  2368.    its assumption about RAM size on the value in memory at 0040:0013 -
  2369.    0040:0014h at the time EDDY begins executing.  If your system has 640K, for
  2370.    example, you will see "80 02" in these locations.
  2371.  
  2372.    EDDY refreshes the display between keystrokes, so you can watch various
  2373.    locations in RAM as they change; e.g., the BIOS timer count at 0040:006Ch,
  2374.    the diskette motor counter at 0040:0040h, or the keyboard buffer and
  2375.    related data starting at 0040:0017h.  (Not true for Color Graphics Adapters
  2376.    -- too much screen "flicker".  See Section 25.3.3 if you have a CGA)
  2377.  
  2378.    It's sometimes interesting to look at other parts of the PC address space,
  2379.    such as ROMs and display memory.  For example, if you press [j] and then
  2380.    enter an offset of "F000:FFFF", you will see the end of the BIOS ROM, which
  2381.    usually has the copyright notice.
  2382.  
  2383.    One curiosity:  When accessing addresses that have no physical memory
  2384.    equivalent, EDDY will show hex "FF" for those bytes; however, bytes with
  2385.    other values sometimes appear.  If you try to go back to display those
  2386.    bytes after they have scrolled off the screen, they may have changed value
  2387.    or even have disappeared.  This does not appear to be a bug in EDDY.  This
  2388.    also occurs with DEBUG and Turbo Debugger when they are used to look at
  2389.    high memory.
  2390.  
  2391.  
  2392.    8.7 LOOK at Entire Disk
  2393.  
  2394.    You may also LOOK at an entire physical disk, regardless of file locations
  2395.    or extents.  This is explained in detail in Section 21.2.
  2396.  
  2397.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  43
  2398.  
  2399.  
  2400.  
  2401.    9.  PATCH Command - [F4], [^F4]
  2402.  
  2403.    Normally, you will use LOOK or FIND before PATCH, in order to locate the
  2404.    place in the file to PATCH.  Once you have found it, press [F4].  If you
  2405.    want to PATCH every file in the directory (one at a time), press [^F4].
  2406.  
  2407.    Pressing [Esc], or pressing [F4] a second time, returns you to LOOK mode.
  2408.  
  2409.    The PATCH mode display is similar to the LOOK mode hex format display with
  2410.    "printability" turned off.  It has two cursors -- one in the hex part of
  2411.    the display and one in the ASCII part.  These cursors move in unison, to
  2412.    facilitate matching corresponding bytes in the two parts of the display.
  2413.  
  2414.    One of the cursors will be blinking, the other not.  The blinking cursor
  2415.    shows where you may enter changes to the data.  [Tab] toggles between hex
  2416.    and ASCII data entry formats.  (If you don't like [Tab] for this purpose,
  2417.    see Section 8.2.1a).  If [Tab] is not the toggle key, it can be used to
  2418.    enter TAB -- 09h -- bytes directly in ASCII format).
  2419.  
  2420.    In ASCII data entry format, the cursor in the text part of the display
  2421.    blinks and the hex cursor does not.  The hex cursor also expands to cover
  2422.    two hex digits, since entering a single text character affects both digits.
  2423.  
  2424.    In either format, as you enter data in one part of the display the
  2425.    corresponding data in the other part is updated and displayed accordingly.
  2426.    Also, any data changed remains highlighted (reverse video) in the display.
  2427.  
  2428.    You can move the cursors to the place you want to change data with the
  2429.    "arrow" keys -- [Left], [Right], [Up] and [Down] -- and [Home] and [End].
  2430.  
  2431.    If you go to PATCH right after a FIND, the blinking cursor will be on the
  2432.    character at the start of the "found" string.  The cursor will be in the
  2433.    same mode (hex/ASCII) used to enter the search string when you did the
  2434.    FIND.  If you press any key except [F4] after the FIND, the cursor will be
  2435.    placed on the first character of the display if you then PATCH.
  2436.  
  2437.    Changes can be made to only one screen at a time.  To UNDO, press [F2].
  2438.  
  2439.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  44
  2440.  
  2441.  
  2442.    9.1 Changing a File's Length
  2443.  
  2444.    You may use [Alt+z] to add bytes at the end of a file, or [Alt+y] to delete
  2445.    bytes, either from the beginning or end of the file.
  2446.  
  2447.    9.1.1 Appending Bytes to a File - [Alt+z]
  2448.  
  2449.    Files may also be expanded using PATCH.  With the cursor at the end of the
  2450.    file, if there is unused space left on the screen, you can add a "^Z" (end-
  2451.    of-file byte) after the last byte in the file by pressing [Alt+z].  You can
  2452.    add as many bytes as you want, up to the limit of space on the screen (or
  2453.    until the disk is full).  Bytes that have been added can also be patched.
  2454.  
  2455.    9.1.2 Deleting Bytes From a File - [Alt+y]/[Alt+a]/[Alt+b]
  2456.  
  2457.    After a press of [Alt+y], EDDY asks whether you want to delete bytes BEFORE
  2458.    or AFTER the cursor, and then waits for [b] or [a], respectively.  You may
  2459.    also press [Esc], if you decide not to delete anything after all.
  2460.  
  2461.    Pressing [b] deletes from the beginning of the file up to the byte at the
  2462.    cursor.  [a] deletes everything in the file after the byte at the cursor.
  2463.    The byte at the cursor is never deleted.  If you press [b] with the cursor
  2464.    on the first byte of the file, or [a] while it's on the last, EDDY won't
  2465.    complain, but nothing will be deleted.
  2466.  
  2467.    Pressing [Alt+a] is equivalent to [Alt+y] followed by [a], with no question
  2468.    asked.  [Alt+b] is equivalent to [Alt+y], then [b].
  2469.  
  2470.  
  2471.    9.2 Updating in PATCH - [Enter] or [^Enter]
  2472.  
  2473.    You may write your changes to disk by pressing [Enter] twice.  Normally --
  2474.    after [Enter] -- EDDY puts the current DOS date and time on a file that has
  2475.    been patched.  If you use [^Enter] to start the UPDATE, EDDY asks whether
  2476.    you want to do this.  (If you have customized EDDY as described in Section
  2477.    25, no question is asked, and the timestamp remains unchanged.)
  2478.  
  2479.    After UPDATE, EDDY will return to LOOK mode.  In LOOK mode you may move to
  2480.    another part of the file, and then press [F4] to go back to PATCH to make
  2481.    more changes.  The PATCH-UPDATE-LOOK-PATCH cycle may be repeated as needed.
  2482.  
  2483.  
  2484.    9.3 PATCHing RAM
  2485.  
  2486.    With option /R turned ON, you may change your PC's memory by using PATCH on
  2487.    the " memory" entry in the display.
  2488.  
  2489.    One thing that is almost SURE to hang up your machine is to mess with the
  2490.    values in the BIOS keyboard buffer pointers (0040:001A - 0040:001D), so
  2491.    EDDY will not allow these locations to be updated.  EDDY won't complain if
  2492.    you TRY to change them, and they'll appear to be changed right after
  2493.    patching, but they'll really still be set to the values DOS has put there.
  2494.  
  2495.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  45
  2496.  
  2497.    9.4 PATCHing Disks by Physical Sector
  2498.  
  2499.    You may also PATCH any bytes on a physical disk, regardless of file
  2500.    locations or extents.  This is explained in detail in Section 21.3.
  2501.  
  2502.    !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
  2503.    WARNING!  USE GREAT CARE WITH SECTOR PATCHING ON "COMPRESSED" OR "EXTENDED"
  2504.    DRIVES -- I.E., DEVICES CREATED AND MANAGED BY DOUBLESPACE, STACKER, AND
  2505.    SIMILAR PRODUCTS.  PATCHING FILES STORED ON THOSE DISKS IS PERFECTLY SAFE,
  2506.    HOWEVER.  SEE SECTION 21.1 FOR MORE INFORMATION.
  2507.    !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
  2508.  
  2509.  
  2510.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  46
  2511.  
  2512.  
  2513.  
  2514.    10. Synchronization Controls - [Alt+c]
  2515.  
  2516.    These Controls affect operation of the COPY, MOVE, DELETE and DESTROY
  2517.    commands, which are described in Sections 11 through 13.
  2518.  
  2519.    When copying, moving or deleting files, you'll often want to choose the
  2520.    files to be operated on based upon whether they are in the target directory
  2521.    or not, and also based on a comparison of their timestamps.  Common cases
  2522.    are when you'd like to give commands such as:
  2523.  
  2524.       "Copy files that are newer than the corresponding files in the target"
  2525.    or
  2526.       "Delete files that are duplicates of those in the target".
  2527.  
  2528.    The Synchronization Controls allow you to just that, as well as many other
  2529.    combinations.
  2530.  
  2531.  
  2532.    10.1  Controls for COPY/MOVE
  2533.  
  2534.    There is a Control for each of the following cases:
  2535.  
  2536.        1. File not in target
  2537.        2. Target file older
  2538.        3. Target file NEWER!
  2539.        4. Target different size (date and time same)
  2540.        5. Same date,time & size
  2541.  
  2542.    The Controls are always checked when a COPY or MOVE command is used.
  2543.  
  2544.    These Controls (1-5) may each have a setting of:
  2545.        "Y" - Yes, tag the file if this statement is true,
  2546.        "N" - No, don't tag the file if this statement is true, or
  2547.        "C" - Confirm before tagging (i.e., ask before tagging)
  2548.  
  2549.    Controls set to "Y" or "N" only affect the operation of the multiple-file
  2550.    COPY and MOVE commands -- [^F5] and [^F6].  They are NOT used with and have
  2551.    NO EFFECT on single-file commands -- e.g., COPY this file ([F5]).
  2552.  
  2553.    Controls set to "C" affect both single- and multiple-file COPY and MOVE
  2554.    command -- [F5], [^F5], [F6], [^F6].  A Control setting of "C" means
  2555.    whenever that case is encountered, the target directory entry will be
  2556.    displayed.  EDDY then waits for you to confirm whether you want to tag the
  2557.    file or not.  This is explained further in Section 10.2. ("C" works
  2558.    slightly differently in batch mode; see Section 20.3 for more information).
  2559.  
  2560.    Thus, for the example...
  2561.  
  2562.       "Copy files that are newer than the corresponding files in the target"
  2563.  
  2564.    the corresponding Control settings would be N,Y,C,C,N.
  2565.  
  2566.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  47
  2567.  
  2568.  
  2569.  
  2570.    With these settings (N,Y,C,C,N), tagging will be done as follows:
  2571.  
  2572.        1. Any files not in the target won't be tagged.
  2573.        2. Any files newer than files with the same name will be tagged.
  2574.        3. If there is a file in the target that is newer than the one in the
  2575.             working directory, the two files' directory entries will be dis-
  2576.             played and EDDY will wait for you to decide whether to tag or not.
  2577.        4. If the files in the working and target directories have the same
  2578.             timestamps, but the files' sizes are different, EDDY will display
  2579.             and wait, as with #3.
  2580.        5. Any files with identical timestamps and sizes won't be tagged.
  2581.  
  2582.    The default Control settings (1 - 5) are Y,Y,C,C,N.  The settings may be
  2583.    displayed and/or changed by pressing [Alt+c].  You may then select the
  2584.    values for the Controls by pressing [y], [n], or [c], or by pressing [Left]
  2585.    or [Right].  Pressing [*] restores default settings.
  2586.  
  2587.    There is one case where the "File not in target" control will be ignored.
  2588.    If you COPY or MOVE when there is no target directory, one of the actions
  2589.    you may take is to create a new directory to serve as the target (see
  2590.    Section 5.2.2).  If you have just created the target, then obviously any
  2591.    file you want to copy will be "not in target".  In this case, Control #1
  2592.    will be treated as "Y" as long as the target directory remains the same.
  2593.  
  2594.  
  2595.    10.2 Tagging Confirmation Process
  2596.  
  2597.    During any (single- or multiple-file) COPY or MOVE, if EDDY encounters a
  2598.    case where the working and target files meet the condition defined by a
  2599.    Control which is set to "C", the directory entries and the following
  2600.    message are displayed:
  2601.  
  2602.       "[F3]/[Alt+F3]:LOOK,  [F5]:COPY,  [F6]:MOVE,  [F7]:DELETE,  else [Esc]"
  2603.  
  2604.    [F3] goes into LOOK mode, to examine the file contents in the working
  2605.    directory, in case you need more information from the file in order to
  2606.    decide what to do.  [Alt+F3] LOOKs at the file contents in the target.  In
  2607.    either case, when you exit from LOOK, you will be at the same place in the
  2608.    display, with EDDY still waiting for one of the other keys to be pressed.
  2609.  
  2610.    [F5], [F6] and [F7] will tag the file for the normal action for that key.
  2611.    [Esc] -- or any other key -- will leave the file untagged.
  2612.  
  2613.    In addition to the cases defined by the Controls, some other situations are
  2614.    also require confirmation:
  2615.  
  2616.    - A COPY or MOVE must be confirmed if the corresponding file in the target
  2617.        has the "read-only" attribute ON.
  2618.    - A MOVE, DELETE or DESTROY must be confirmed if the file has the "read-
  2619.        only" attribute ON.
  2620.  
  2621.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  48
  2622.  
  2623.  
  2624.  
  2625.    One situation can be tricky:  if the confirmation display is because of
  2626.    "Target file NEWER!", and you proceed to LOOK mode -- [F3] -- and from
  2627.    there to PATCH -- [F4] -- your patching will normally update the file's
  2628.    timestamp.  Upon return, EDDY will find that the condition requiring your
  2629.    decision no longer exists (i.e., the timestamp is NOW), and will therefore
  2630.    automatically tag the file for COPY or MOVE.
  2631.  
  2632.  
  2633.    10.3 Synchronizing/Reconciliation Directories
  2634.  
  2635.    Often it is useful to be able to ensure that two directories have exactly
  2636.    the same versions of the same files.  This is particularly handy when you
  2637.    are working with more than one computer (e.g., one at home and one at the
  2638.    office) and using a floppy to carry data back and forth.
  2639.  
  2640.    With the Synchronization Controls set to their default values (Y,Y,C,C,N),
  2641.    this is easily done, as follows:
  2642.  
  2643.        a. Set one of the directories to be synchronized as working and the
  2644.             other as target (it doesn't matter which is which).
  2645.        b. Press [^F5] to tag all files that need to be copied.
  2646.        c. Press [Enter] twice to start the copying (UPDATE) process.
  2647.        d. Press [Alt+x] to exchange the working and target directories.
  2648.        e. Repeat Steps b and c.
  2649.  
  2650.    Synchronization of the directories is now complete.  The only way there
  2651.    could be any difference between them is if copies of a file existed
  2652.    originally in both directories, and had the same timestamp and size, but
  2653.    the files' contents were different.
  2654.  
  2655.  
  2656.    10.4 Controls for DELETE/DESTROY
  2657.  
  2658.    There is also a sixth Synchronization Control, which determines whether the
  2659.    first 5 will be used to control the DELETE and DESTROY commands, too:
  2660.  
  2661.        6. CONTROLS for Delete?
  2662.  
  2663.    This Control may be set to either "Y" or "N" -- "C" is not applicable.
  2664.  
  2665.    When Control 6 is set to "Y", the files in the target will be checked as
  2666.    specified by the settings of Controls 1 - 5, and the tagging will be done
  2667.    accordingly.  If there is no target directory, Control #6 has no effect.
  2668.  
  2669.    Thus, for the example...
  2670.  
  2671.        "Delete files that are duplicates of those in the target"
  2672.  
  2673.    the Control settings (1 - 6) would be N,N,N,N,Y,Y (or N,C,C,C,Y,Y if you
  2674.    want EDDY to tell you about any differences).
  2675.  
  2676.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  49
  2677.  
  2678.  
  2679.  
  2680.    11.  COPY Command - [F5], [^F5]
  2681.  
  2682.    You may copy files and/or directories (and all their contents).  The
  2683.    Synchronization Controls (see Section 10) work closely with the COPY
  2684.    command to help you in deciding which files you want to copy.
  2685.  
  2686.    When copying, EDDY has the capability of changing the new copy's data in
  2687.    certain ways -- "converting" the file.  The available CONVERT functions are
  2688.    described in Section 11.5.
  2689.  
  2690.    EDDY also allows you to copy RAM to a file (see Section 18), and to copy
  2691.    raw disk-image data -- sectors, clusters, complete disks -- to and from
  2692.    files (see Section 22).
  2693.  
  2694.    The COPY command actually just "tags" a file to indicate that it has been
  2695.    selected.  The word "Copy" will appear, to show the file has been tagged.
  2696.    The actual copy will be done when you enter UPDATE mode.  After UPDATE,
  2697.    "copied" will appear in the display for that file.
  2698.  
  2699.    If you have indicated other changes to be made to the file's directory
  2700.    entry (renaming, timestamping or attribute settings), these changes will be
  2701.    made during the UPDATE process before the copying, so the target copy will
  2702.    have the same settings as the working directory file after the update.
  2703.  
  2704.    An exception to this is the archive attribute bit.  Files copied will have
  2705.    the archive attribute turned ON in the target directory (unless you are
  2706.    using option /A, or the target is on a remote disk).  For files copied from
  2707.    a fixed disk (or RAM disk) to a floppy, the archive attribute is also set
  2708.    OFF in the working directory.  In all other cases, the archive attribute is
  2709.    left unchanged in the working directory.
  2710.  
  2711.    Also, if a file with the "shared" attribute is copied, the result in the
  2712.    target will not have that attribute.
  2713.  
  2714.    Copied files normally receive the same date and time as the original; if
  2715.    you want to put the current timestamp on copies, use [^Enter] to start the
  2716.    UPDATE process, rather than [Enter].  If you use [^Enter], EDDY will ask
  2717.    you whether or not you want new timestamps.
  2718.  
  2719.    Changing the target while files are tagged for copying will result in these
  2720.    files being un-tagged EDDY will warn you if this would occur.
  2721.  
  2722.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  50
  2723.  
  2724.  
  2725.  
  2726.    11.1 COPY a File - [F5]
  2727.  
  2728.    Press [F5] to tag the current file for copying.  If there is no target
  2729.    directory, EDDY will ask for one.  Entering target directories is explained
  2730.    in Sections 5.2.2 and 5.3.5.
  2731.  
  2732.    If the target directory contains a subdirectory that has the same name as
  2733.    the file you are trying to tag, EDDY will inform you of the conflict and no
  2734.    tagging will occur on that file.
  2735.  
  2736.  
  2737.    11.2 COPY Multiple Files - [^F5]
  2738.  
  2739.    [^F5] will review all files in the working directory for copying, except
  2740.    those already tagged for COPY, MOVE, DELETE or DESTROY.  All files (but NOT
  2741.    subdirectories) which meet the criteria defined by the Synchronization
  2742.    Controls (see Section 10) will be tagged for copying.
  2743.  
  2744.    As the list of files is being reviewed, [^c] or [BackSpace] may be pressed
  2745.    to terminate the process before all files have been reviewed.  If you just
  2746.    want to pause temporarily, to look at the screen or think about what's
  2747.    going on, press and hold [ScrollLock].  All processing will stop.  Release
  2748.    the key to continue.
  2749.  
  2750.    If you want EDDY to check only those files from the cursor and further
  2751.    down, turn on option /L before pressing [^F5].
  2752.  
  2753.    Using option /5 on the command line is the batch mode equivalent of [^F5].
  2754.    See Section 20 for more information on this.
  2755.  
  2756.  
  2757.    11.3 Copying Files With Disk Errors
  2758.  
  2759.  
  2760.    If you have a file that's on a disk that has "bad spots", EDDY will often
  2761.    let you save the "good" parts, by COPYing the file.  See Section 24.4 for
  2762.    more information on this.
  2763.  
  2764.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  51
  2765.  
  2766.  
  2767.  
  2768.    11.4 COPY a Directory - [F5]
  2769.  
  2770.    Press [F5] to tag the current subdirectory for copying.  If there is no
  2771.    target directory, EDDY will ask for one.  Entering target directories is
  2772.    explained in Sections 5.2.2 and 5.3.3.  The target may be on a different
  2773.    drive from the working directory.
  2774.  
  2775.    If the target directory contains a file that has the same name as the sub-
  2776.    directory you are trying to tag, EDDY will inform you of the conflict and
  2777.    no tagging will occur on that subdirectory.
  2778.  
  2779.    Also, the target must not be in a path which includes the directory to be
  2780.    copied (i.e., you can't copy a directory to its own child or other
  2781.    subordinate directory).
  2782.  
  2783.    If there is a subdirectory in the target with the same name, you will be
  2784.    asked if you wish to overwrite it.  If you do, the directory will be tagged
  2785.    for copying.  When you UPDATE, the subdirectory in the target, WITH ALL THE
  2786.    FILES AND SUBDIRECTORIES IN IT, will be deleted first and then replaced by
  2787.    the directory being copied and all ITS files and subdirectories.  There is
  2788.    no checking or comparison of file timestamps involved in this copy process;
  2789.    it is a complete replacement of one tree by another.
  2790.  
  2791.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  52
  2792.  
  2793.  
  2794.  
  2795.    11.5 CONVERT File Data
  2796.  
  2797.    If you have a WordStar-like file, with lots of high-order bits obscuring
  2798.    the text, you can make a readable copy by copying with bit-stripping.  If
  2799.    you want to get rid of TAB characters in a file, you can also do that.
  2800.  
  2801.    11.5.1  TABs to Spaces - [Alt+0] thru [Alt+8]
  2802.  
  2803.    To get rid of TABs in a file, tag it by pressing [Alt+number].  [Alt+#]
  2804.    (where "#" is "2" thru "8") means expand (at UPDATE time) any TABs in the
  2805.    file with spaces to move to the next #-byte boundary, resulting in a larger
  2806.    file.  This can possibly cause an out-of-space condition during the UPDATE,
  2807.    as explained in Section 24.3.  [Alt+1] replaces each TAB by a single space.
  2808.    [Alt+0] deletes the TABs completely, resulting in a smaller file.
  2809.  
  2810.    Files which have been tagged in this way will show the TAB expansion used
  2811.    in parenthesis after the "Copy"; e.g., if you used [Alt+4], you would see
  2812.    "Copy(4)" to the right of that file's display.  If bit-stripping was also
  2813.    used, you would see "Copy(b4)".
  2814.  
  2815.    As every byte must be scanned individually, TAB expansion is much slower
  2816.    than other copying.
  2817.  
  2818.    11.5.2  Bit-Stripping - [Alt+b]
  2819.  
  2820.    To get rid of the high-order bits that obscure the text in some files, tag
  2821.    the file(s) by pressing [Alt+b].  The new copy will have no high-order bits
  2822.    in it after the UPDATE is done.
  2823.  
  2824.    Files which have been tagged in this way will show "Copy(b)" to the right
  2825.    of the file's display.
  2826.  
  2827.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  53
  2828.  
  2829.  
  2830.  
  2831.    12.  MOVE Command - [F6], [^F6]
  2832.  
  2833.    You may move files and/or directories (and all their contents).  The
  2834.    Synchronization Controls (see Section 10) work closely with the MOVE
  2835.    command to help you in deciding which files you want to move.
  2836.  
  2837.    Moving a file places its entry in the target directory and deletes it from
  2838.    the working directory.  This is the same as doing a COPY and then a DELETE.
  2839.    The heading information showing the number of files in the display and the
  2840.    number of free bytes on the disk will be updated.
  2841.  
  2842.    The MOVE command actually just "tags" a file to indicate that it has been
  2843.    selected.  The word "Move" will appear, to show the file has been tagged.
  2844.    The actual move will be done when you enter UPDATE mode.
  2845.  
  2846.    After UPDATE, "moved" will appear in the display for that file.  The
  2847.    display of size, date, etc., will be cleared, indicating that the file no
  2848.    longer exists in that directory.  If you re-sort the display, or move to
  2849.    another working directory and then return, files moved won't be displayed.
  2850.  
  2851.    If you have indicated other changes to be made to the file's directory
  2852.    entry (renaming, timestamping or attribute settings), these changes will be
  2853.    made during the UPDATE process, before the move is done.
  2854.  
  2855.    Files moved will normally have the archive attribute turned ON in the
  2856.    target directory (unless you are using option /A, or the target is on a
  2857.    remote disk).
  2858.  
  2859.    Also, if a file with the "shared" attribute is moved, the result in the
  2860.    target will not have that attribute.
  2861.  
  2862.    Moved files normally receive the same date and time as the original; if
  2863.    you want to put the current timestamp on the moved files, use [^Enter] to
  2864.    start the UPDATE process, rather than [Enter].  If you use [^Enter], EDDY
  2865.    will ask you whether or not you want new timestamps.
  2866.  
  2867.    Changing the target while files are tagged for moving will result in these
  2868.    files being un-tagged.  EDDY will warn you if this would occur.
  2869.  
  2870.  
  2871.    12.1 MOVE a File - [F6]
  2872.  
  2873.    Press [F6] to select the current file to be moved.  If there is no target
  2874.    directory specified, EDDY will ask for one.  Entering target directories is
  2875.    explained in Sections 5.2.2 and 5.3.3.
  2876.  
  2877.    If the target directory contains a subdirectory that has the same name as
  2878.    the file you are trying to tag, EDDY will inform you of the conflict and no
  2879.    tagging will occur on that file.
  2880.  
  2881.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  54
  2882.  
  2883.  
  2884.  
  2885.    12.2 MOVE Multiple Files - [^F6]
  2886.  
  2887.    [^F6] will review all files in the working directory for moving, except
  2888.    those already tagged for COPY, MOVE, DELETE or DESTROY.  All files (but NOT
  2889.    subdirectories) which meet the criteria defined by the Synchronization
  2890.    Controls (see Section 10) will be tagged for moving.
  2891.  
  2892.    As the list of files is being reviewed, [^c] or [BackSpace] may be pressed
  2893.    to terminate the process before all files have been reviewed.  If you just
  2894.    want to pause temporarily, to look at the screen or think about what's
  2895.    going on, press and hold [ScrollLock].  All processing will stop.  Release
  2896.    the key to continue.
  2897.  
  2898.    If you want EDDY to check only those files from the cursor and further
  2899.    down, turn on option /L before pressing [^F5].
  2900.  
  2901.    Using option /6 on the command line is the batch mode equivalent of [^F6].
  2902.    See Section 20 for more information on this.
  2903.  
  2904.  
  2905.    12.3 MOVE a Directory - [F6]
  2906.  
  2907.    This feature is sometimes called "prune and graft".  Press [F6] to tag the
  2908.    current subdirectory for moving.  If there is no target directory, EDDY
  2909.    will ask for one.  Entering target directories is explained in Sections
  2910.    5.2.2 and 5.3.3. The target may be on a different drive from the working
  2911.    directory.
  2912.  
  2913.    If the target directory contains a file that has the same name as the sub-
  2914.    directory you are trying to tag, EDDY will inform you of the conflict and
  2915.    no tagging will occur on that subdirectory.
  2916.  
  2917.    Also, the target must not be in a path which includes the directory to be
  2918.    moved (i.e., you can't move a directory to its own child or other
  2919.    subordinate directory).
  2920.  
  2921.    If there is a subdirectory in the target with the same name, you will be
  2922.    asked if you wish to overwrite it.  If you do, the directory will be tagged
  2923.    for moving.  When you UPDATE, the subdirectory in the target, WITH ALL THE
  2924.    FILES AND SUBDIRECTORIES IN IT, will be deleted first and then replaced by
  2925.    the directory being moved and all ITS files and subdirectories.  There is
  2926.    no checking or comparison of file timestamps involved in this move process;
  2927.    it is a complete replacement of one tree by another.
  2928.  
  2929.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  55
  2930.  
  2931.  
  2932.  
  2933.    12.4 Fast Directory Move
  2934.  
  2935.    If the working and target directories are on the same drive, it is possible
  2936.    to bypass the tedious file-by-file copying that is normally used in moving
  2937.    a directory.  As this is achieved by using techniques other than standard
  2938.    DOS services, EDDY will ask your preference before beginning the move
  2939.    process when you start the UPDATE.
  2940.  
  2941.    Fast move cannot be used if a directory of the same name already exists in
  2942.    the target.
  2943.  
  2944.    EDDY speeds up the directory move task by writing directly to the working
  2945.    and target directories, and using DOS services where available.  No direct
  2946.    manipulation of the File Allocation Table (FAT) is involved.
  2947.  
  2948.  
  2949.    12.4.1 What Makes it Fast?
  2950.  
  2951.    This process has been exhaustively tested by the author and many users,
  2952.    without any problems.  However, some of us are hesitant (read
  2953.    "intelligent") about using programs that mess with our disks in
  2954.    non-standard ways.  Therefore, the following information is offered.
  2955.  
  2956.    Specifically, the steps involved in a "fast" subdirectory move are:
  2957.  
  2958.        1. Set the "directory" attribute OFF in the subdirectory's entry in
  2959.             the working directory, making DOS think the subdirectory is a file
  2960.        2. Move the "file" to the target directory, with the standard DOS
  2961.             "rename" command
  2962.        3. Turn the "directory" attribute back ON in the target directory
  2963.        4. Adjust the "cluster number" in the moved directory's ".." (parent)
  2964.           entry to point to the target rather than the working directory
  2965.  
  2966.    After a directory move, you may notice a lot of disk activity before the
  2967.    EDIT display reappears.  Don't be alarmed; the program is simply rereading
  2968.    all the information in both the working and target directories, to ensure
  2969.    that all the data displayed reflects the new tree structure.
  2970.  
  2971.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  56
  2972.  
  2973.  
  2974.  
  2975.    12.4.2 Had a Problem?  Don't Panic!
  2976.  
  2977.    If there is a problem with any of the above steps (e.g., a power failure
  2978.    during the update), recovery is straightforward.
  2979.  
  2980.    - If the subdirectory is still shown as a directory entry in the working
  2981.    directory, there's no problem.
  2982.  
  2983.    - If you have reason to suspect there might have been a problem, and the
  2984.    entry is shown in the target as a directory, it's possible that step 4 was
  2985.    not completed successfully.  This is resolved quickly and easily by running
  2986.    "CHKDSK /F" on the disk.  CHKDSK will display "Invalid sub-directory entry"
  2987.    and fix the cluster number automatically.
  2988.  
  2989.    - If there was a problem with step 3, the subdirectory will be shown as a
  2990.    "file" (i.e., no "directory" attribute) in the target, with a length of
  2991.    either one cluster -- typically, 2048 bytes -- or zero.  Don't panic!
  2992.    There's only one little bit that has to be changed.  To fix this problem,
  2993.    LOOK at the target, then LOOK at the disk to display the raw directory
  2994.    data.  Move the display until the entry for the "file" is at the top, and
  2995.    PATCH offset 0Bh to "10h".  Your directory is now restored.  Exit from
  2996.    LOOK, and you'll see the result.
  2997.  
  2998.    - If the subdirectory is shown as a "file" in the working directory, LOOK
  2999.    at the disk, and proceed as described in the previous paragraph.
  3000.  
  3001.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  57
  3002.  
  3003.  
  3004.  
  3005.    13.  DELETE Command - [F7], [^F7]
  3006.  
  3007.    To select the current file for deletion, press [F7].  No other changes may
  3008.    be made to a file that is selected for deletion.
  3009.  
  3010.    "Delete" appears next to the file.  The deletion will be done when you
  3011.    UPDATE, and "deleted" will appear.  All directory information (size, date,
  3012.    etc.) will be blanked out, indicating that the file no longer exists in
  3013.    that directory.  If you re-sort the display, files deleted won't be shown.
  3014.    The heading information showing the number of files in the display and the
  3015.    number of free bytes on the disk will be updated to reflect the deletion.
  3016.  
  3017.    If Synchronization Control #6 (see Section 10.4) is set to "N" (the
  3018.    default), [^F7] tags all files in the working directory for deletion,
  3019.    except those already tagged for COPY, MOVE or DESTROY.
  3020.  
  3021.    If Control #6 is "Y", the other Controls determine which files will be
  3022.    tagged by [^F7], based upon a comparison of working and target directories.
  3023.    If Control #6 is "Y" and there is no target directory, you'll be asked for
  3024.    one.  If you don't enter a target, Control #6 will be treated as "N" for
  3025.    processing the current [^F7] command.
  3026.  
  3027.    To interrupt EDDY after [^F7], press [^c] or [BackSpace].  If you just want
  3028.    to pause temporarily, to look at the screen or think about what's going on,
  3029.    press and hold [ScrollLock].  All processing will stop.  Release the key to
  3030.    continue.
  3031.  
  3032.    Using option /7 on the command line is the batch mode equivalent of [^F7].
  3033.    See Section 20 for more information on this.
  3034.  
  3035.  
  3036.    13.1 Deleting Subdirectories
  3037.  
  3038.    Subdirectories may also be deleted, even if they are not empty.  EDDY will
  3039.    warn you that the directory is not empty when you press [F7], and ask
  3040.    whether you want to delete or not.  If you choose to proceed, all files in
  3041.    the directory, plus any subordinate subdirectories and all of their files,
  3042.    will be deleted when you UPDATE.
  3043.  
  3044.    In this type of deletion, no check is made for read-only file attributes on
  3045.    the files in the subdirectory -- they are all deleted without further
  3046.    question.  Obviously, this type of deletion should be done only when you
  3047.    are sure there's nothing important left in the directory.
  3048.  
  3049.    As the deletions are being made, the full path and file name of each file
  3050.    or subdirectory being deleted will be displayed prior to its deletion.  In
  3051.    the display, subdirectories are shown with a final '\' after the name, to
  3052.    distinguish then from files.
  3053.  
  3054.    As with other UPDATE actions, pressing a key during the UPDATE will suspend
  3055.    activity until you decide how you want to proceed.
  3056.  
  3057.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  58
  3058.  
  3059.  
  3060.  
  3061.    13.2 Logical DELETE (Ignore) - [Alt+F7], [Alt+^F7]
  3062.  
  3063.    Pressing [Alt+F7] flags a file with "(Ignore)".  It will then be ignored by
  3064.    any of the repeating (i.e., [Ctrl]-shifted) commands.  This lets you
  3065.    eliminate files from a list that you want to do a repeated FIND on, for
  3066.    example, not wasting time with files that are not of interest for the FIND.
  3067.    [Alt+F7] also undoes any changes that may be pending on the file.
  3068.  
  3069.    Pressing a key for any command which affects a logically deleted file
  3070.    cancels the "(Ignore)".  [Left] or [Right] also cancels the "(Ignore)".
  3071.  
  3072.    [Alt+^F7] flags all files with "(Ignore)".  Thus you can ignore all but a
  3073.    few files when executing the next command, such as [^f], the multi-file
  3074.    FIND, or [Shift+^F9], the multi-file Point-and-Shoot.  It's easier to
  3075.    "ignore all" and then UNDO the few, rather than ignoring one by one.
  3076.  
  3077.  
  3078.    13.3 DESTROY - [Shift+F7], [Shift+^F7]
  3079.  
  3080.    If you want to protect the contents of deleted files from being looked at
  3081.    by anyone, even using utilities designed for that purpose, use "DESTROY".
  3082.    Destroying means to overwrite a file, thus destroying the data in it, and
  3083.    then delete the file from the working directory.
  3084.  
  3085.    To select the current file for destruction, press [Shift+F7].  "Destroy"
  3086.    appears next to the file.  The actual overwrite and deletion will be done
  3087.    when you enter UPDATE mode.  EDDY overwrites the file with question marks.
  3088.    Afterward, "destroyed" appears next to that file, and all directory
  3089.    information is erased.  The counts of the numbers of files in the display
  3090.    and the free bytes on the disk will be updated to reflect the deletion.
  3091.  
  3092.    If Synchronization Control #6 (see Section 10.4) is set to "N" (the
  3093.    default), [Shift+^F7] tags all files in the working directory for deletion,
  3094.    except those already tagged for COPY, MOVE or DELETE.
  3095.  
  3096.    If Control #6 is set to "Y", then the other Controls are used to determine
  3097.    which files will be tagged by [Shift+^F7], based upon a comparison of
  3098.    working and target directory entries.  If Control #6 is "Y" and there is no
  3099.    target directory, you'll be asked for one.  If you don't enter a target,
  3100.    Control #6 will be treated as "N" for processing the current [Shift+^F7]
  3101.    command.
  3102.  
  3103.    To interrupt EDDY after [Shift+^F7], press [^c] or [BackSpace].  If you
  3104.    just want to pause temporarily, to look at the screen or think about what's
  3105.    going on, press and hold [ScrollLock].  All processing will stop.  Release
  3106.    the key to continue.
  3107.  
  3108.    Using option /8 on the command line is the batch mode equivalent of
  3109.    [Shift+^F7].  See Section 20 for more information on this.
  3110.  
  3111.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  59
  3112.  
  3113.  
  3114.  
  3115.    14.0 DOS Gateway
  3116.  
  3117.    EDDY allows you to exit to DOS (the DOS "shell"), execute other commands or
  3118.    programs, and return to EDDY to pick up where you left off.  All requested
  3119.    changes and actions will still be in effect when you return.
  3120.  
  3121.    When you exit to DOS, all memory used by HELP and/or by menus is released
  3122.    for use by DOS.  In addition, if you are using the gateway from EDIT mode
  3123.    (as opposed to LOOK), any memory used by LOOK as well as the i/o buffer
  3124.    space will be released.  This memory will be reallocated as required when
  3125.    you return control to EDDY.
  3126.  
  3127.  
  3128.    14.1 The DOS Shell - [F9]
  3129.  
  3130.    From EDIT or LOOK mode, pressing [F9] exits to DOS.  EDDY will ask you to
  3131.    confirm that you want to exit.  When you exit, EDDY loads a new copy of
  3132.    COMMAND.COM, which will process your DOS commands normally.  The screen is
  3133.    cleared, followed by COMMAND.COM's announcement, and then the DOS prompt.
  3134.  
  3135.    The default directory will be EDDY's current working directory.  You may
  3136.    change this if you wish.  EDDY will restore it when you return.
  3137.  
  3138.    When you're ready to return to EDDY, type "EXIT" at the DOS command prompt.
  3139.  
  3140.    If you forget to EXIT, you may run short of memory later on, because memory
  3141.    remains assigned to both EDDY and the extra copy of COMMAND.COM.  To remind
  3142.    you to EXIT, EDDY changes the DOS prompt to end with "Exit>".  (This is not
  3143.    done if your DOS environment is larger than 10,529 bytes -- an EDDY
  3144.    internal buffer limitation.).  If you don't want this reminder added to
  3145.    your prompt, see Section 25.3.1.
  3146.  
  3147.    If you use the DOS Shell from LOOK often, you may want to use option /U
  3148.    when you execute EDDY.  This leaves more memory for DOS to work with.
  3149.  
  3150.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  60
  3151.  
  3152.  
  3153.  
  3154.    14.2  Point-n-Shoot
  3155.  
  3156.    Point-n-Shoot refers to the capability to move the cursor to a file you
  3157.    want to operate on ("point") and press a key ("shoot") to begin the
  3158.    operation.  EDDY offers three types of point-n-shoot operations:
  3159.  
  3160.    - Execute the file (for .COM, .EXE or .BAT files)
  3161.  
  3162.    - Operate on the file with any command you choose.
  3163.  
  3164.    - Operate on the file with a command you have previously defined in the
  3165.      "EDDY.USE" file.
  3166.  
  3167.  
  3168.    14.2.1 Execute .COM, .EXE or .BAT File - [Alt+F9]
  3169.  
  3170.    When the cursor is located on a file with an extension of "COM", "EXE" or
  3171.    "BAT", pressing [Alt+F9] executes that file.
  3172.  
  3173.    The filename is first displayed in a dialog box, so that you may edit the
  3174.    command line if you like, to add filenames, switches, redirection, or
  3175.    whatever is appropriate for the file involved.
  3176.  
  3177.    When you are ready to execute the file, press [Enter] (or [Alt+F9] again).
  3178.  
  3179.    When the program or batch file finishes, EDDY waits for a key to be
  3180.    pressed.  This pause allows time for you to read anything that may have
  3181.    been displayed on the screen by the file which was just executed.
  3182.  
  3183.  
  3184.    14.2.2 Execute Default Command - [Shift+F8]
  3185.  
  3186.    You don't have to guess ahead of time what you might want to do to a file.
  3187.    Any command you like may be used on any of your files, at any time.  You
  3188.    may even use commands that are not related to a specific file, if you wish,
  3189.    although this would normally be done via the DOS Gateway.
  3190.  
  3191.    Press [Shift+F8] to get a dialog box showing the current "default" command.
  3192.    This command may be used as-is, edited and then used, or replaced entirely
  3193.    by whatever command you want to use on the current file.  Press [Enter] (or
  3194.    [Shift+F8] again) to execute the command.
  3195.  
  3196.    When you set up or modify the default command, EDDY will ask whether you
  3197.    want to pause after executing it, before returning to the EDIT mode
  3198.    display.  This pause allows time for you to read anything that may have
  3199.    been displayed on the screen by the file which was just executed.
  3200.  
  3201.    The commands you enter in the dialog box must include the full path name to
  3202.    tell EDDY where the program to be executed is located.
  3203.  
  3204.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  61
  3205.  
  3206.  
  3207.    Also, the program name must be followed by at least one blank, and the
  3208.    command, including the filename to be operated on, cannot be longer than 76
  3209.    bytes.  Any bytes beyond the 76th will be truncated.
  3210.  
  3211.    You may save the new or edited command as the new default if you wish.  If
  3212.    you want to make it a permanent default, use EDDY's customizing feature -
  3213.    see Section 25.  If you save the command, the name of the current file will
  3214.    be replaced in the command for each new file you use it on.  Your decision
  3215.    as to whether to pause after executing the command is also saved.
  3216.  
  3217.    An un-customized version of EDDY has a default of "C:\UTIL\DOS2UNIX %".
  3218.    The "%" marks the place in the command where the current filename will be
  3219.    inserted.  This is included as an example only, and may not be suitable for
  3220.    your system.  A comment is also included with the sample, as a reminder of
  3221.    the restrictions.  In constructing your own default, the comments may be
  3222.    written over (or not), as you wish.
  3223.  
  3224.  
  3225.    14.2.3 Point-n-Shoot with EDDY.USE - [Shift+F9]
  3226.  
  3227.    You may define different commands to be used with different files.  For
  3228.    instance, you might want to use PKZIP to look at the contents of ".ZIP"
  3229.    files, without leaving EDDY.  The files and corresponding commands must be
  3230.    defined in a file called "EDDY.USE", which may be created with EDLIN or any
  3231.    other editor or word processor which can produce a simple ASCII file.
  3232.  
  3233.    A sample EDDY.USE is part of the EDDY distribution package.  This sample
  3234.    includes extensive explanatory comments, and I hope it will suggest ways in
  3235.    which EDDY can help your system be easier and more convenient to use.
  3236.  
  3237.    Files are defined in EDDY.USE as usual for DOS (including wildcards), and
  3238.    the commands are similar to .BAT file commands.  The full path must be
  3239.    given in the command.  There must be at least one space after the filename.
  3240.  
  3241.    EDDY.USE must be in a directory defined in your PATH variable, the current
  3242.    directory, or (if you have DOS 3.0 or higher) in the same directory that
  3243.    you executed EDDY from.
  3244.  
  3245.    EDDY selects a command from EDDY.USE based upon a comparison of the current
  3246.    filename and extension with the file definitions at the beginning of the
  3247.    lines in EDDY.USE.
  3248.  
  3249.    If the current file doesn't match any definition in EDDY.USE -- or if
  3250.    EDDY.USE can't be found -- you may will see a dialog box containing the
  3251.    default command (see Section 14.2.2, above).
  3252.  
  3253.    When you press [Shift+F9], EDDY will display a dialog box with the command
  3254.    that is to be executed.  You may press [Shift+F9] again or [Enter] to
  3255.    proceed, or you may edit the command before using it.
  3256.  
  3257.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  62
  3258.  
  3259.  
  3260.  
  3261.    For example, if EDDY.USE contains the line:
  3262.  
  3263.                            *.ZIP  C:\UTIL\PKZIP -V  %1
  3264.  
  3265.    pressing [Shift+F9] with the cursor on EXAMPLE.ZIP will give the display:
  3266.  
  3267.                           C:\UTIL\PKZIP -V  EXAMPLE.ZIP
  3268.  
  3269.    and pressing [Enter] will list the contents of EXAMPLE.ZIP (assuming, of
  3270.    course, that you have PKZIP in the UTIL directory).
  3271.  
  3272.    The replaceable parameter ("%1" in the example) tells EDDY where to insert
  3273.    the current filename before executing the command.  The "1" in "%1" has no
  3274.    significance; any digit may be used, or the "%" used by itself.  It is used
  3275.    in the example only to emphasize the similarity to batch files.  Only the
  3276.    first occurrence of "%" is used by EDDY.
  3277.  
  3278.    Commands from EDDY.USE are displayed and may be edited before they are
  3279.    used.  For example, suppose after viewing the contents of EXAMPLE.ZIP as
  3280.    described above, you want to extract the THIS.ONE file you found there.
  3281.    Just press [Shift+F9] again and edit the command to:
  3282.  
  3283.                       C:\UTIL\PKUNZIP  EXAMPLE.ZIP  THIS.ONE
  3284.  
  3285.    After executing the command, EDDY normally returns immediately to the EDIT
  3286.    directory display.  If you want to pause after the command is executed, use
  3287.    a "|" (the DOS piping symbol) as the first character in the command.  With
  3288.    the previous example, the command in EDDY.USE would be:
  3289.  
  3290.                           | *.ZIP  C:\UTIL\PKZIP  V  %1
  3291.  
  3292.    If you edit (modify) the command before executing it, EDDY will always
  3293.    pause before returning to the EDIT display.
  3294.  
  3295.  
  3296.    14.2.4 Point-n-Shoot Again (and again...) - [Shift+^F8] / [Shift+^F9]
  3297.  
  3298.    This facility allows you to repeat the same operation on multiple files, by
  3299.    giving a single command to EDDY.  You may use the default command, by
  3300.    pressing [Shift+^F8], or a command from EDDY.USE, by pressing [Shift+^F9].
  3301.  
  3302.    In either case, the command will be executed first on the current file, and
  3303.    then on files below that in the current display.  This is the same effect
  3304.    as using option /L has with other repeating ([Ctrl]-shifted) commands.
  3305.  
  3306.    With [Shift+^F8], the command will by default be executed only on files
  3307.    from the display that have the SAME extension as the current file.
  3308.    However, you will be asked before execution starts whether you want to
  3309.    operate on all files (i.e., "*.*").
  3310.  
  3311.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  63
  3312.  
  3313.  
  3314.  
  3315.  
  3316.    With [Shift+F9], EDDY.USE defines which files will be operated on, and no
  3317.    question is asked before processing begins.  Thus, if EDDY.USE defines the
  3318.    command for use with "*.*", it will operate on all files.
  3319.  
  3320.    Any files tagged as "Ignore" will be skipped by these commands.
  3321.  
  3322.    The commands in the EDDY.USE file for repetitive processing are defined and
  3323.    interpreted the same as commands for use with individual files (see Section
  3324.    14.2.3), except a command which is to be used by the [Shift+^F9] processing
  3325.    must be preceded by the caret character ("^").  This identifies it as a
  3326.    command for repetitive, multi-file processing, rather than for use only on
  3327.    the current file.  Commands starting with "^" are ignored when EDDY
  3328.    processes the [Shift+F9] keypress; commands without the initial "^" are
  3329.    ignored during [Shift+^F9] processing.
  3330.  
  3331.    This allows you to specify different processing for the same files, depen-
  3332.    ding on whether they are processed singly or as a group.
  3333.  
  3334.    For example, suppose you want to use your editor on a single program source
  3335.    file, but compile or assemble to get listings of source files you have
  3336.    modified and tested satisfactorily.  This is the way the two commands below
  3337.    could be used if they were contained in EDDY.USE.
  3338.  
  3339.                         *.ASM C:\PE\PE2 /PC:\PE\ASM.PRO %1
  3340.  
  3341.                        ^ *.ASM C:\MASM\MASM %1,NUL,C:\LIST;
  3342.  
  3343.    You would simply display the appropriate directory, "(Ignore)" any .ASM
  3344.    files you don't wish to assemble, and then press [Shift+^F9].
  3345.  
  3346.    If the file doesn't match any definition in EDDY.USE, you may use EDDY's
  3347.    default point-and-shoot command.
  3348.  
  3349.    After executing the command, EDDY normally returns immediately to the EDIT
  3350.    directory display.  If you want to pause after each file is processed, use
  3351.    a "|" (the DOS piping symbol) in the command, right after the "^".
  3352.    Continuing with the previous example, the command in EDDY.USE would be:
  3353.  
  3354.                          ^| *.ASM C:\MASM %1,NUL,C:\LIST;
  3355.  
  3356.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  64
  3357.  
  3358.  
  3359.  
  3360.    15.  QUIT Command - [F10], [Esc]
  3361.  
  3362.    When you are through with EDDY, press [F10].  [F10] will restore your
  3363.    default drive and directory to the settings they had when you executed EDDY
  3364.    (or to your "recall" directory, if you have selected one as described
  3365.    below). EDDY will terminate immediately and return to DOS.
  3366.  
  3367.    If you have changes pending which have not yet been processed by UPDATE,
  3368.    EDDY will remind you that there are such changes, and ask you to confirm
  3369.    that you want to QUIT anyway.
  3370.  
  3371.    One exception to this may occur when option /K is used.  Pressing [F10]
  3372.    when a message is displayed and waiting for a key press will only erase the
  3373.    message (like any other key).  You must press [F10] again to terminate.
  3374.  
  3375.    Some users prefer to use [Esc] as a way to QUIT from EDIT.  If you want to
  3376.    QUIT by using [Esc], just press it and hold it down.
  3377.  
  3378.  
  3379.    15.1 Directory Recall - [Shift+F10], [Shift+^F10]
  3380.  
  3381.    [Shift+F10] selects the current working directory as the "recall"
  3382.    directory.  Directory recall is a "place-holding" mechanism, used in two
  3383.    ways:  1) When you exit from EDDY, this directory will be set as the DOS
  3384.    default, and 2) If you press [Shift+^F10], the directory will be "recalled"
  3385.    as the new working directory.  If no recall directory is selected, the DOS
  3386.    default directory, as it was before you executed EDDY, will be used.
  3387.  
  3388.    15.2 Exit to Directory - [Alt+F10]
  3389.  
  3390.    [Alt+F10] exits from EDDY -- just like [F10] -- but leaves the current
  3391.    working directory as the DOS default.
  3392.  
  3393.    [Alt+F10] may also be used from the directory tree diagram display (see
  3394.    Section 5.3.2).  If you press [Alt+F10] in that case, EDDY will exit to the
  3395.    directory that is currently highlighted in the display.
  3396.  
  3397.  
  3398.    15.3 EGA and VGA Display Control - [^F10]
  3399.  
  3400.    If you have an EGA or VGA monitor, EDDY normally resets the display to the
  3401.    same number of lines that were in use when EDDY was executed.  However, if
  3402.    you use [^F10] to quit, the result is the same as [F10], except the display
  3403.    will be left with the number of lines per screen you have set (by using
  3404.    option /E) while in EDDY.
  3405.  
  3406.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  65
  3407.  
  3408.  
  3409.  
  3410.    16.  FIND and/or REPLACE String in File, Disk or RAM
  3411.  
  3412.    To find a string, press [Alt+f] when the EDIT mode cursor is on that
  3413.    display entry, or when in LOOK mode.  (In LOOK mode, [/] or [\] have the
  3414.    same effect as [Alt+f].) If you want to search through all files in the
  3415.    working directory, press [^f] -- see Section 16.5.
  3416.  
  3417.    As an example, suppose you were using EDDY to LOOK at this file
  3418.    ("EDDY.DOC") and were positioned to the "Technical Support" section.  If
  3419.    you pressed [Alt+f], the display would be similar to Figure 16-1.
  3420.  
  3421.    The second line in the window shows a series of "5F"s and underlines.  The
  3422.    underlines have no special significance.  They only mark the place where
  3423.    you may enter the string you want EDDY to find.
  3424.  
  3425.    When you have entered the string EDDY is to search for, press [Enter] for a
  3426.    "close" match search or [^Enter] for an exact match.
  3427.  
  3428.  
  3429.                    * * *  (text continues on next page)  * * *
  3430.  
  3431. EXAMPLE "FIND" SCREEN:
  3432. ================================================================================
  3433. bug, surely!), if you take the trouble to report it, I'll try to solve it.
  3434. And I'll get back to you with a fix, if possible.
  3435.  
  3436. EDDY's PATCH command, using an area within EDDY reserved for this purpose,
  3437. makes it reasonably easy to fix minor bugs without having to wait for a whole
  3438. new version of the program.
  3439.  
  3440. With any problem report, please include the following information:
  3441.  
  3442.     1. Version number of your copy of EDDY (as shown on the logo
  3443. |------------------------------------------------------------------------------|
  3444. |                  Enter new FIND string, or use this one...                   |
  3445. |          5F 5F 5F 5F 5F 5F 5F 5F 5F 5F 5F 5F 5F 5F 5F 5F     ________________|
  3446. |                                                              ^               |
  3447. |           [Enter] to FIND "close" match, [^Enter] for exact match            |
  3448. |                                                                              |
  3449. |                     Global match is:"?"  [Alt+g] to change                   |
  3450. |------------------------------------------------------------------------------|
  3451.     5. As complete a description of the problem as possible -
  3452.        - what did you enter on the command line?
  3453.        - [PrtSc] listings of the screen before and after the problem
  3454.        - how was EDDY's output different from what you expected?
  3455.        - any other information that seems relevant
  3456.  
  3457. -LOOK-   EDDY.DOC      bits=8  tab=8  line=1357      [F1]:HELP     [Alt+F1]:MENU
  3458. ================================================================================
  3459.  
  3460.                                   Figure 16-1
  3461.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  66
  3462.  
  3463.  
  3464.    A "close" match will ignore upper and lower case differences.  One or more
  3465.    blanks in the string will match any number of consecutive blanks, carriage
  3466.    returns, line feeds or TABs (or any combination).  An exact match requires
  3467.    that every character match completely, including case and blanks.
  3468.  
  3469.    A close match will also find words that have been hyphenated and broken
  3470.    across two lines.  If you enter the string "bicycle" and then ask EDDY for
  3471.    a "close" match, it will find any occurrence of "bicycle" or even of "bicy-
  3472.    cle" (i.e., broken at the end of the line).
  3473.  
  3474.    Once you have entered a string, that string becomes the default for any
  3475.    later FINDs, on the same or other file.
  3476.  
  3477.    Exact match FINDs are much faster than "close" matches.
  3478.  
  3479.    In LOOK mode, you may press [f] to repeat the previous FIND, using the same
  3480.    string and the same type of match (close or exact).
  3481.  
  3482.    When EDDY finds the string, it goes to LOOK mode with the line containing
  3483.    the string at the top.  The first byte of the string is highlighted, and it
  3484.    blinks.  If there are long lines, and the string is off-screen, EDDY will
  3485.    move the display window to show the string.
  3486.  
  3487.    If the string begins with a carriage return or line feed, the display will
  3488.    be in hex format, even if it was in ASCII when the search began.  This is
  3489.    because these characters are used as line break controls, and do not appear
  3490.    in an ASCII display itself; therefore, hex format is used.
  3491.  
  3492.    If the string was not found, EDDY will "beep", the message "Not found" will
  3493.    be displayed, and the last page of the file will be shown.
  3494.  
  3495.    You may interrupt EDDY's search by pressing any key.
  3496.  
  3497.  
  3498.    16.1 Entering New FIND Strings
  3499.  
  3500.    The dialog box for FIND (and FIND & REPLACE -- see Section 16.6) is
  3501.    different from other dialog boxes.  This is because of the requirement to
  3502.    enter two incompatible data formats (hex and ASCII) on the same line.
  3503.  
  3504.    You may notice that the line where you enter strings looks a lot like
  3505.    EDDY's PATCH mode display.  In fact, the same data entry routines are used,
  3506.    and you enter your string just as though you were patching this line.
  3507.  
  3508.    Values 00 - 7Eh may be entered in ASCII format.  00h - 19h may be entered
  3509.    by using the [Ctrl]-shifted keys:  [^@], [^a], etc.  In hex, all values may
  3510.    be entered.  [Tab] toggles between hex and ASCII; if you don't like [Tab]
  3511.    for this purpose, see Section 8.2.1a.  If [Tab] is not the toggle key, it
  3512.    can be used to enter TAB (09h) bytes in ASCII format.
  3513.  
  3514.    If any part of the string is entered in hex, or if the string has a hyphen
  3515.    in it, matches to words broken over two lines will not be found.
  3516.  
  3517.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  67
  3518.  
  3519.  
  3520.  
  3521.    Under the data entry line, marking the end of the string, is an up arrow
  3522.    (shown in Figure 16-1 as "^").  This arrow normally points to the last
  3523.    character entered, although you may move back to change a character if you
  3524.    make a mistake, and the arrow won't move.  To mark the end of the string at
  3525.    another place, move the cursor to that place and press [Up].
  3526.  
  3527.    If you begin entering characters in the first (leftmost) position of the
  3528.    string, EDDY erases whatever previous string was there and accepts your
  3529.    input as a completely new string.  However, if you move the cursor to some
  3530.    position further to the right, and enter your first character there, you
  3531.    can make changes to the previous string (including the first position).
  3532.  
  3533.    You may also use [Ins] and [Del] to edit FIND strings.
  3534.  
  3535.    Two other features provide a lot of flexibility for FINDing data:  the
  3536.    "global match" character and the "don't match" attribute.
  3537.  
  3538.  
  3539.    16.2 Global Match Character - [Alt+g]
  3540.  
  3541.    The global match character works like the "?" wild card in DOS.  If a FIND
  3542.    string has the global match character, that position in the string will
  3543.    match any byte.  For example, the FIND string "str?ng" will match "strxng",
  3544.    "str@ng", "str ng", etc.  The default global match character is "?".
  3545.  
  3546.    If you want to search for a string which includes the character currently
  3547.    used for global matching, you can specify any other character by pressing
  3548.    [Alt+g] and then typing the new global match character.  You may use any
  3549.    character except space for global matching.  The new global match character
  3550.    remains in effect until changed by another [Alt+g].
  3551.  
  3552.  
  3553.    16.3 "Don't Match" Attribute - [Alt+k]
  3554.  
  3555.    You may also give any character in the FIND string the "don't match" (or
  3556.    "match anything BUT this") attribute.  This means that the character in
  3557.    that position in the string will match any character in the file EXCEPT the
  3558.    actual character in the string.  To give this attribute to a character,
  3559.    press [Alt+k] and then type the character.  The character will be high-
  3560.    lighted on the screen to remind you it has the "don't match" attribute.
  3561.  
  3562.    For example, if the second character in the string "xyz" were designated as
  3563.    "don't match", the string would be a successful match to "x0z", "x=z",
  3564.    etc., but would not match "xyz".
  3565.  
  3566.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  68
  3567.  
  3568.  
  3569.  
  3570.    If your string contains a global match character, you may designate it as
  3571.    "don't match" if you wish.  In this case, that character (in that string
  3572.    position only) is no longer treated as a global match.  For example,
  3573.    suppose the global match character is "?", and you use the string "abc?"
  3574.    with the last character as "don't match".  Then EDDY would not find "abc?"
  3575.    if it occurred in the file, but it would find "abc-" or "abcd", etc.
  3576.  
  3577.    Similarly, if you designate a blank as "don't match", it will no longer
  3578.    match multiple blanks, carriage returns, line feeds or TABs.  Instead, it
  3579.    will simply be treated as a match to any single character except blank.
  3580.  
  3581.    Typing any character in a string position previously designated "don't
  3582.    match" removes the "don't match" attribute.
  3583.  
  3584.  
  3585.    16.4 FIND "Any Text"
  3586.  
  3587.    Sometimes you may want to search a .COM or .EXE file to see what messages
  3588.    might be lurking in it (such as "gotcha!" or "virus", for example).  Or you
  3589.    might want to see how many words in a document have more than "n" letters.
  3590.  
  3591.    You can do things like this by entering a FIND string that has only "?"s
  3592.    (or whatever global match character you are using).  If your string has
  3593.    only "?"s, it will FIND any string of upper- or lowercase LETTERS that is
  3594.    at least as long as your string.  It will also match strings containing
  3595.    spaces, as long as there are not two or more in a row.
  3596.  
  3597.    Thus, the FIND string "?????" would match:
  3598.                            "abcde", "AbcDE", or "a c e"
  3599.    but would not match:
  3600.                            "ab&de", "Ab-DE", or "a  de".
  3601.  
  3602.    You can also use the "don't match" attribute ([Alt+k]) with strings of
  3603.    "?"s.  Don't match in this case means match only if the character is NOT a
  3604.    letter ("space" is not a letter).
  3605.  
  3606.    For example, if the middle "?" in the above FIND string were given the
  3607.    "don't match" attribute, the string would match:
  3608.                            "ab&de", "Ab-DE", or "a  de"
  3609.    but would not match:
  3610.                            "abcde", "AbcDE", or "a c e".
  3611.  
  3612.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  69
  3613.  
  3614.  
  3615.  
  3616.    16.5 Search for FIND String in All Files - [^f]
  3617.  
  3618.    To search through all files for the given string, press [^f].  The first
  3619.    file from your current display will be displayed in LOOK mode, and the FIND
  3620.    window will be ready for you to enter the FIND string.
  3621.  
  3622.    If a match is found, the first character is highlighted in a LOOK mode
  3623.    display, as for [Alt+f] or [f].  If there is no match in that file, the
  3624.    search will proceed to the next file, continuing until there is a match or
  3625.    there are no more files.
  3626.  
  3627.    After a match, you have 4 choices:
  3628.  
  3629.    1.  Pressing [f] searches the file for any more matches, and proceeds to
  3630.    the next file if no match is found.
  3631.  
  3632.    2.  You can press [Alt+f] to change the FIND string, and the new string
  3633.    will used for matching from that point on.
  3634.  
  3635.    3.  [Esc] exits from the current file without searching further, and moves
  3636.    on to the next file.
  3637.  
  3638.    4.  To stop the search and return to EDIT mode, press [^c] or [BackSpace].
  3639.  
  3640.  
  3641.    16.6 FIND and REPLACE - [Alt+r]
  3642.  
  3643.    To replace occurrences of the FIND string with a new string (the "REPLACE
  3644.    string"), press [Alt+r].  The FIND window will be expanded to allow entry
  3645.    of a REPLACE string in the lower portion of the window.  REPLACE strings
  3646.    are entered exactly the same as FIND strings, and may be ASCII and/or hex.
  3647.  
  3648.    Switching between the two parts of the window is done with the cursor keys:
  3649.    [Up] moves from the REPLACE part to the FIND part, and [Down] moves from
  3650.    FIND to REPLACE.
  3651.  
  3652.    To shrink the window back to normal FIND-only size, press [Alt+r] again.
  3653.  
  3654.    If you begin the search with the expanded window on the screen, then the
  3655.    REPLACE string will be used whenever a match is found for the FIND string.
  3656.    When you begin the search, you will be asked whether you want EDDY to pause
  3657.    for you to confirm before replacing, or just to go ahead and make the
  3658.    replacement automatically.
  3659.  
  3660.    If the REPLACE string is shorter than the FIND string (e.g., with a "close"
  3661.    match that includes white space), the REPLACE string will be padded with
  3662.    trailing blanks as required to make the two strings the same length.  A
  3663.    REPLACE string may not be longer than its corresponding FIND string.
  3664.  
  3665.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  70
  3666.  
  3667.  
  3668.    17.  File Selection by Filtering
  3669.  
  3670.    You may use EDDY's "filter" feature to display only files which have
  3671.    certain attributes (e.g., read only) and/or particular timestamps (e.g.,
  3672.    files with timestamps later than 9 A.M.  today).  Filter values may be
  3673.    entered from the command line or while executing EDDY.  When filters are in
  3674.    use, they are shown in the top line of the display.
  3675.  
  3676.    If the working directory has files that are not displayed because a filter
  3677.    is being used, an asterisk will appear just to the right of the file count
  3678.    field in the display heading (e.g., "53*files" instead of "53 files").
  3679.  
  3680.    Filters normally have no effect on subdirectory entries in the display.
  3681.    All subdirectories are displayed, regardless of attribute settings or
  3682.    timestamp, with two exceptions:  if the directory attribute is selected as
  3683.    part of an attribute filter or if the display sequence is "unsorted", then
  3684.    subdirectory entries are filtered in the same manner as other file entries.
  3685.  
  3686.    When you set or change a filter and there are other changes pending, such
  3687.    as renaming, copying, etc., EDDY checks to be sure that all files with
  3688.    changes will still be included in the display after the new filter takes
  3689.    effect.  If not, you will be warned that some changes will be lost, and
  3690.    given a chance to decide whether to proceed or not.
  3691.  
  3692.  
  3693.    17.1 Filtering by Attribute
  3694.  
  3695.    You may filter the directory display so that it contains only files with
  3696.    attributes you specify, by using an attribute selection parameter.
  3697.  
  3698.  
  3699.    17.1.1 Attribute Selection from the Command Line
  3700.  
  3701.    A command line attribute selection parameter begins with a plus sign ("+")
  3702.    to distinguish it from a path specification.  The "+" is followed by one or
  3703.    more letters for the file attributes you choose.  The letters to use are
  3704.    the same as the letters in EDDY's display heading:  R, H, S, D, A or N.
  3705.  
  3706.    To select files which have the attribute ON, enter the letter in upper
  3707.    case; for files with the attribute OFF, lower case.  Thus, to select only
  3708.    files which are "hidden", enter "+H"; for files which are read-only and not
  3709.    modified since last backup (i.e., "archive" attribute off), enter "+Ra" or
  3710.    "+aR" (the order makes no difference).  If more than one attribute is
  3711.    selected, all must match in order for a file to be selected.
  3712.  
  3713.    If you specify an incorrect letter, or use the same letter in both upper
  3714.    and lower case, EDDY will terminate with an "Invalid format" error message.
  3715.  
  3716.    Attribute selections are shown in the display heading.  The letters for the
  3717.    selected attributes will blink, showing they're used for file selection,
  3718.    and they will be the same case -- upper or lower -- as you specified.
  3719.  
  3720.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  71
  3721.  
  3722.  
  3723.  
  3724.    17.1.2 Attribute Selection in EDDY - [Alt+a]
  3725.  
  3726.    Press [Alt+a] for attribute selection while executing EDDY.  You may then
  3727.    enter the attributes to be used for filtering.  [Esc] restores the
  3728.    attribute filter previously in effect, if any.
  3729.  
  3730.    To select an attribute, press the key for the corresponding letter -- [R],
  3731.    [H], [S], [D], [A] or [N].  Pressing a key once selects "attribute ON",
  3732.    twice selects "attribute OFF", and a third time deselects the attribute.
  3733.    When you are satisfied with the selection, press [Enter].
  3734.  
  3735.    You may also select attributes by moving the cursor to an attribute and
  3736.    clicking the mouse or pressing [Tab].
  3737.  
  3738.  
  3739.    17.2 Filtering by Timestamp
  3740.  
  3741.    You may filter the directory display so that it contains only files with
  3742.    timestamps in a range you specify, by using timestamp selection.
  3743.  
  3744.  
  3745.    17.2.1 Timestamp Selection from the Command Line
  3746.  
  3747.    A command line timestamp selection parameter is enclosed in double quote
  3748.    marks Immediately following the first quote must be one of the following:
  3749.    "]", "<" or "=".  These mean that the files to be selected for display must
  3750.    have timestamps greater than, less than, or equal to the timestamp you use.
  3751.  
  3752.    Next, you must provide the timestamp value.  This may be a date, a time, or
  3753.    both.  Following the timestamp value is the closing quote mark.
  3754.  
  3755.    Leading zeros must be used when entering dates if needed to make up a two-
  3756.    digit value -- e.g., "5/31/88" would be rejected; "05/31/88" would be O.K.
  3757.  
  3758.    Times are based on a 12-hour clock, and must be in the form "hh:mma" for
  3759.    A.M. times, or "hh:mmp" for P.M.  Again, leading zeros are required.
  3760.  
  3761.    If you wish to specify both date and time, the date and time must be
  3762.    separated by one space.
  3763.  
  3764.    Some examples of valid timestamp values are:
  3765.  
  3766.     ">05/31/88 09:00p" - select files with timestamps later than this
  3767.  
  3768.     "=07/23/86" - select files created at any time on this date only
  3769.  
  3770.     "<10:30p" - select files created before this time, on any date
  3771.  
  3772.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  72
  3773.  
  3774.  
  3775.  
  3776.    Normally, EDDY will re-sort the display when you use timestamp filtering.
  3777.    When the filter includes a date, the display will be sorted by date.  If
  3778.    the filter has only a time, it will be sorted by time.
  3779.  
  3780.    However, if you have explicitly changed the display sequence (by using
  3781.    option /1 or one of the sort commands), then filtering by timestamp will
  3782.    not cause a re-sort.
  3783.  
  3784.    If you make a mistake with the timestamp, EDDY will usually terminate with
  3785.    an "Invalid format" error.  However, if you leave off one or the other of
  3786.    the quotes, and your filter value includes a "<" or a ">", DOS will use
  3787.    these as redirection symbols, rather than as part of the command line.
  3788.  
  3789.    With "<", you will probably get a "File not found" message, while with ">"
  3790.    the "Invalid format" and logo display output from EDDY will be put in a
  3791.    (hopefully new!) file in your default directory.
  3792.  
  3793.    If these possibilities worry you, you may use "+" and "-" instead of ">"
  3794.    and "<", when entering a timestamp filter value from the command line.
  3795.  
  3796.    17.2.2 Timestamp Selection in EDDY - [Alt+q]
  3797.  
  3798.    Press [Alt+q] for timestamp selection.  Any timestamp filter in effect at
  3799.    that time will be cancelled, the null timestamp "=00-00-00 00:00p" will
  3800.    appear in the top line, and the cursor will move to the "=" sign.  If you
  3801.    don't want to enter a new timestamp value, press [Enter] while the null
  3802.    timestamp is displayed, and no timestamp filter will be used.
  3803.  
  3804.    Otherwise, the null timestamp may be edited just as though it was a normal
  3805.    file timestamp in the body of the display.  When you are happy with the
  3806.    filter value, press [Enter].  If you enter an invalid timestamp, EDDY will
  3807.    "beep" at you and move the cursor to the field in error.
  3808.  
  3809.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  73
  3810.  
  3811.  
  3812.  
  3813.    18.  Playing With RAM
  3814.  
  3815.    You may access your PC's main memory from EDDY, in much the same way as for
  3816.    files.  If option /R is turned ON, the display will include an entry with
  3817.    the name " memory", showing the no. of bytes of RAM in your system (as
  3818.    indicated by your system's BIOS), and the current DOS date and time.
  3819.  
  3820.    This entry will appear at the end of the list of files in most displays,
  3821.    with two exceptions:  if the sort sequence is inverted, the " memory" entry
  3822.    will be at the top; and if there are more files in the directory than EDDY
  3823.    can display at once, the " memory" entry will not appear at all.
  3824.  
  3825.    " memory" is not included in the display of number of files and bytes used.
  3826.  
  3827.    You may LOOK at, FIND strings in, or PATCH the " memory" entry.  For more
  3828.    information on these, see the respective sections of this document.
  3829.  
  3830.    Pressing [F5] while the cursor is on the " memory" entry tags RAM for
  3831.    COPYing.  When you UPDATE, the RAM data will be dumped into a file named
  3832.    "-MEMORY-.@@@" (in the target).  If such a file already exists, it will be
  3833.    overwritten.  The file will be as large as your PC's memory, so on floppy-
  3834.    only systems you probably won't have enough room.
  3835.  
  3836.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  74
  3837.  
  3838.  
  3839.  
  3840.    19.  Volume Identifiers
  3841.  
  3842.    DOS offers two methods of identifying disks:  volume labels and volume
  3843.    serial numbers.  EDDY provides services for both.
  3844.  
  3845.  
  3846.    19.1 Volume Labels - [Alt+v]
  3847.  
  3848.    To create or change a volume label on a disk, press [Alt+v].  Then type the
  3849.    new label in the dialog box on the screen, and [Enter].  The new label will
  3850.    take effect immediately.
  3851.  
  3852.    Labels may contain ANY characters you like, with one exception:  the first
  3853.    byte may not be 05 (hex), as this is reserved by DOS.  You may even enter a
  3854.    label of all blanks, if you want, or labels containing characters such as
  3855.    colons, backslashes and periods.
  3856.  
  3857.    When creating a new label for an unlabelled disk, you'll get an error if
  3858.    the disk's root directory already has the maximum number of entries (e.g.,
  3859.    112 for a DSDD 5-1/4" floppy) allowed by DOS.
  3860.  
  3861.    To delete an existing label, press [Alt+Shift+v].
  3862.  
  3863.  
  3864.    19.2 Volume Serial Numbers - [^v]
  3865.  
  3866.    To create or change a volume serial number on a disk, press [^v].  Then
  3867.    type the new serial number in the dialog box on the screen, and [Enter].
  3868.  
  3869.    The serial number consists of 8 hexadecimal digits ("0" - "9", "A" - "F").
  3870.    There is also a hyphen displayed, but this is only for readability.  The
  3871.    hyphen is not part of the serial number.
  3872.  
  3873.  
  3874.    20.  Batch Operations
  3875.  
  3876.    20.1 Commands Available
  3877.  
  3878.    In batch mode, you may COPY, MOVE, DELETE or DESTROY files.  The desired
  3879.    command is specified on the command line, as a "numeric" option.  The
  3880.    numbers used correspond to function keys used interactively...
  3881.  
  3882.              /5 - COPY files ([^F5])      /6 - MOVE files ([^F6])
  3883.              /7 - DELETE files ([^F7])    /8 - DESTROY files ([Shift+^F7])
  3884.  
  3885.    Other numeric options useful in batch mode are:
  3886.  
  3887.    20.2 Processing Sequence
  3888.  
  3889.    /1x - "x" defines the sequence (E = extension, D = date/time, N = name,
  3890.    etc.) in which files will be processed.  Lowercase means inverted order.
  3891.  
  3892.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  75
  3893.  
  3894.  
  3895.  
  3896.    20.3 Synchronization Controls
  3897.  
  3898.    /2xxxxxx - "x"s define Synchronization Control settings (see Section 10).
  3899.    If the default settings are correct, /2 is not required.  Normal defaults
  3900.    are Y,Y,C,C,N,N.
  3901.  
  3902.    Thus, to COPY files newer than corresponding files in the target, enter a
  3903.    command like...
  3904.                                "EDDY/5  C:\WORK A:"
  3905.  
  3906.    To DELETE files that are duplicates of those in the target, enter...
  3907.                            "EDDY/7/2NNNNYY C:\WORK A:"
  3908.  
  3909.    Attribute and timestamp filters may be used to select files in batch mode.
  3910.    Files with read-only, hidden or system attributes will not be processed in
  3911.    batch mode unless they are explicitly selected by an attribute filter.
  3912.  
  3913.    If a file to be copied or moved is "read-only" in the target, the command
  3914.    will proceed only if the file is also read-only in the working directory.
  3915.    Otherwise, the file name will be displayed with a message to inform you of
  3916.    the situation, and the file will not be copied or moved.
  3917.  
  3918.    NOTE:  In batch mode the Control setting "C" works differently than it does
  3919.    when you use EDDY interactively.  If the condition is encountered corres-
  3920.    ponding to a Syncronization Control which is set to "C", the file name and
  3921.    the message describing the condition will be displayed for information
  3922.    only, and the file will NOT be copied, moved, or otherwise acted upon.
  3923.  
  3924.    If there are many such messages, so that they scroll off before you can
  3925.    read them, remember you may press [ScrollLock] anytime to pause the
  3926.    display.
  3927.  
  3928.  
  3929.    20.4 ERRORLEVEL
  3930.  
  3931.    Non-batch mode executions always leave ERRORLEVEL set to zero.
  3932.  
  3933.    When a batch mode execution finishes, "ERRORLEVEL" will be set according to
  3934.    the results, as follows:
  3935.  
  3936.    If all updates were done successfully, ERRORLEVEL will be set to zero.  If
  3937.    updates were not done because no files qualified according to the criteria
  3938.    given by the Synchronization Controls, ERRORLEVEL will be set to 255.
  3939.  
  3940.    Any error encountered will terminate EDDY, and ERRORLEVEL will be set to
  3941.    the standard DOS error number as applicable (e.g., ERRORLEVEL = 2 for "File
  3942.    not found", 3 for "Path not found, etc.").
  3943.  
  3944.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  76
  3945.  
  3946.  
  3947.  
  3948.    21. Disk Jockey's Delight  (format-level disk functions)
  3949.  
  3950.    These functions are not available when looking at remote (network) drives.
  3951.  
  3952.  
  3953.    21.1  "Compressed" or "Extended" Drives (DoubleSpace, etc.)
  3954.  
  3955.    EDDY can do things to your disks that you normally shouldn't do if using
  3956.    disk capacity expansion utilities such as DoubleSpace, Stacker, SuperStor,
  3957.    or similar products.  Specifically, sorting directories is virtually
  3958.    certain to cause problems on these "drives" (i.e., your data may
  3959.    disappear!), and patching disk sectors (files are OK) is very likely to
  3960.    cause problems if you're not completely certain of what you're doing.
  3961.  
  3962.    Therefore, EDDY tries to identify such drives before proceeding with any of
  3963.    these functions.  If a drive is identified as being one of these, you will
  3964.    either be warned and asked for confirmation before EDDY proceeds, or the
  3965.    function will simply be rejected, depending upon what you're trying to do.
  3966.  
  3967.    The first time one of these functions is requested on a drive, if EDDY
  3968.    can't decide automatically whether it's a real drive (some vendors provide
  3969.    information on how to detect their products, and some don't) you will be
  3970.    asked...  Is <x:> a "compressed drive" - DoubleSpace, Stacker, etc (y/n)?
  3971.    ...and EDDY will react according to your answer for the rest of that
  3972.    session.  If you customize, this information will be recorded permanently,
  3973.    so you won't be pestered by the question any more.
  3974.  
  3975.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  77
  3976.  
  3977.  
  3978.  
  3979.    21.2 LOOK at Entire Disk - [F3]
  3980.  
  3981.    If you press [F3] on the third line of the display ("Drive X:  is..."), you
  3982.    will enter LOOK mode for the entire disk, without regard to any file or
  3983.    directory structure.  In effect, the whole disk is treated as a single
  3984.    file.  The display will begin with the sector on the disk where the current
  3985.    working directory is located.
  3986.  
  3987.    When LOOKing at the disk, the display is always in hex.  However the
  3988.    meaning of "Offset" is different; "Offset" specifies physical disk sectors
  3989.    (normally 512 bytes each).  Here's an example of this type of display:
  3990.  
  3991. ================================================================================
  3992.  Offset    00 01 02 03 04 05 06 07-08 09 0A 0B 0C 0D 0E 0F          ASCII     P
  3993.  
  3994.      1B0   6F 6E 73 AC 20 77 68 69 63 E8 20 61 72 E5 20 A0 ??? ons, which are
  3995.      1C0   63 6F 6D 70 75 74 65 E4 20 A0 61 75 74 6F 6D 61 ??? computed  automa
  3996.      1D0   74 69 63 61 6C 6C F9 20 8D 0A A0 A0 A0 A0 A0 A0 ??? tically ..
  3997.      1E0   A0 A0 A0 77 68 65 EE 20 65 6E 74 65 72 65 64 AE ???    when entered.
  3998.      1F0   20 20 49 EE 20 63 61 73 65 F3 20 77 68 65 72 E5 ???   In cases where
  3999. 0000193F   20 74 68 E5 20 64 69 6D 65 6E 73 69 6F 6E 61 EC      the dimensional
  4000. 0633 010   20 77 65 69 67 68 F4 20 A0 69 F3 20 8D 0A A0 A0      weight  is ..
  4001.      020   A0 A0 A0 A0 A0 A0 A0 67 72 65 61 74 65 F2 20 74            greater t
  4002.      030   68 61 EE 20 74 68 E5 20 61 63 74 75 61 EC 20 77     han the actual w
  4003.      040   65 69 67 68 74 AC 20 74 68 E5 20 53 79 73 74 65     eight, the Syste
  4004.      050   ED 20 61 75 74 6F 6D 61 74 69 63 61 6C 6C F9 20     m automatically
  4005.      060   8D 0A A0 A0 A0 A0 A0 A0 A0 A0 A0 E3 61 6C 63 75     ..         calcu
  4006.      070   6C 61 74 65 F3 20 64 69 6D 65 6E 73 69 6F 6E 61     lates dimensiona
  4007.      080   EC 20 77 65 69 67 68 F4 20 63 68 61 72 67 65 73     l weight charges
  4008.      090   2E 0D 0A 2E 70 61 0D 7d A0 A0 A0 A0 A0 A0 46 72     ....pa..      Fr
  4009.      0A0   6F ED 20 A0 69 6E 66 6F 72 6D 61 74 69 6F EE 20     om  information
  4010.      0B0   A0 65 6E 74 65 72 65 64 AC 20 74 68 E5 20 53 79      entered, the Sy
  4011.      0C0   73 74 65 ED 20 63 72 65 61 74 65 F3 20 A0 E1 20     stem creates  a
  4012.      0D0   A0 64 65 74 61 69 6C 65 E4 20 8D 0A A0 A0 A0 A0      detailed ..
  4013.      0E0   A0 A0 68 69 73 74 6F 72 F9 20 A0 6F E6 20 65 61       history  of ea
  4014.      0F0   63 E8 20 73 68 69 70 6D 65 6E F4 20 72 65 63 6F     ch shipment reco
  4015.  
  4016. -LOOK-   Drive C:\     bits=8  tab=8  line= ?      [F1]:HELP       [Alt+F1]:MENU
  4017. ================================================================================
  4018.  
  4019.                                    Figure 21-1
  4020.  
  4021.    The first line of each sector's display has the logical sector number in
  4022.    the "Offset" field (0000193F in the example).  The other lines for the
  4023.    indicate the offset of the bytes from the beginning of the sector.
  4024.  
  4025.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  78
  4026.  
  4027.  
  4028.  
  4029.    If the sector is the first sector of a cluster, the second line also shows
  4030.    the cluster number (0633 in the example).  Numbering starts with cluster 2,
  4031.    which begins with the first sector in the disk's data area.  Sectors in the
  4032.    DOS disk control area, which include the boot sector(s), File Allocation
  4033.    Table(s), root directory, etc., do not have cluster numbers.
  4034.  
  4035.    However, the starting sectors of the root directory and File Allocation
  4036.    Table(s) have "ROOT" and "FAT" respectively, under the sector number.
  4037.  
  4038.    You may notice the "???" strings in the first few lines of Figure 21-1;
  4039.    this is the way EDDY indicates sectors on which DOS has reported that an
  4040.    error has occurred while reading the data.  The data may not be accurate.
  4041.  
  4042.  
  4043.    21.2.1 Jumping Around
  4044.  
  4045.    Several "shortcut" methods are available to move the display quickly to
  4046.    various parts of the disk:
  4047.  
  4048.    a. Jump to Sector - [j]
  4049.  
  4050.    To move to a particular sector, press [j].  EDDY will ask you to enter the
  4051.    sector number, in hex.  When you have done so, the display will move
  4052.    accordingly.  If the number entered is larger than the last sector number
  4053.    on the disk, the last sector will be displayed.
  4054.  
  4055.    b. Jump to Cluster - [Alt+j]
  4056.  
  4057.    To move to a particular cluster, press [Alt+j].  EDDY will ask you to enter
  4058.    the cluster number, in hex.  When you have done so, the display will move
  4059.    accordingly.  If the number entered is larger than the last cluster number
  4060.    on the disk, the last cluster will be displayed.
  4061.  
  4062.    c. Jump to Working Directory - [Alt+w]
  4063.  
  4064.    Pressing [Alt+w] moves you to the first cluster of the working directory.
  4065.    (This is automatic when you LOOK at disk, but can also be used any time.)
  4066.  
  4067.    d. Jump to Target Directory - [Alt+t]
  4068.  
  4069.    If there is a target directory, and it is on the same disk as the working
  4070.    directory, it will be displayed if you press [Alt+t].
  4071.  
  4072.    e. Jump to Starting Cluster - [Alt+s]
  4073.  
  4074.    A directory entry contains a pointer (cluster number) to the first disk
  4075.    area allocated to that file or directory.  This pointer remains in the
  4076.    entry even after the file has been deleted, until that entry is used again.
  4077.  
  4078.    To look at the data on the disk at the logical start of the area allocated
  4079.    to a file or directory (the cluster), position the directory entry on the
  4080.    first line of the screen and press [Alt+s].
  4081.  
  4082.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  79
  4083.  
  4084.  
  4085.  
  4086.    f. Jump to Next Cluster - [Alt+n]
  4087.  
  4088.    Space on the disk is allocated in clusters, and the record of space alloca-
  4089.    ted is maintained in "chains" of cluster numbers, in the FAT.  To view the
  4090.    data in the next cluster in the chain for a file, press [Alt+n].
  4091.  
  4092.    g. Jump to Unallocated Cluster - [Alt+u]
  4093.  
  4094.    When [Alt+u] is pressed after entry to LOOK, the first cluster that has not
  4095.    been allocated is displayed.  After that, [Alt+u] displays the next
  4096.    sequential unallocated cluster.  When all unallocated clusters have been
  4097.    displayed, the display returns to the first one.
  4098.  
  4099.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  80
  4100.  
  4101.  
  4102.  
  4103.    21.2.2 Displaying Directory Entries - [Alt+d]
  4104.  
  4105.    If you have a directory entry displayed at the top of the screen, such as
  4106.    would be the case after an [Alt+w] or [Alt+t] command, described above, you
  4107.    can use [Alt+d].  The result will be a display (nearly) like EDDY's EDIT
  4108.    mode format for that entry.  An example is given in Figure 21-2.
  4109.  
  4110.    The attributes are shown by the letters "RHYDASV".  These are the same as
  4111.    in the EDIT mode heading line (except "V", which indicates the volume label
  4112.    attribute).  In this display, they show the attribute settings directly;
  4113.    upper case means attribute ON, lower case means OFF.
  4114.  
  4115.    The "cluster" number is the starting cluster which is (or was, if the entry
  4116.    has been deleted) allocated to the file or subdirectory.
  4117.  
  4118.    After displaying a directory entry, any keypress will clear it.  If the key
  4119.    used is also a valid command, it will be executed.
  4120.  
  4121. ================================================================================
  4122.  Offset    00 01 02 03 04 05 06 07-08 09 0A 0B 0C 0D 0E 0F          ASCII     P
  4123.  
  4124. 00000053   49 42 4D 42 49 4F 20 20 43 4F 4D 27 00 00 00 00     IBMBIO  COM'....
  4125. ROOT 010   00 00 00 00 00 00 01 48 CA 10 02 00 DF 4D 00 00     .......HJ..._M..
  4126. |------------------------------------------------------------------------------|
  4127. |        IBMBIO  .COM     19935  6-10-88  9:00:02a RHYdAsv, cluster=0002       |
  4128. |------------------------------------------------------------------------------|
  4129.      050   00 00 00 00 00 00 01 48 30 11 1B 00 1C 63 00 00     .......H0....c..
  4130.      060   44 4F 53 20 20 20 20 20 20 20 20 13 00 00 00 00     DOS        .....
  4131.      070   00 00 00 00 00 00 11 A2 3F 10 28 00 00 00 00 00     ......."?.(.....
  4132.      080   54 4F 53 48 49 42 41 31 36 30 30 28 00 00 00 00     Toshiba1600(....
  4133.      090   00 00 00 00 00 00 21 AC 9B 12 00 00 00 00 00 00     ......!,........
  4134.      0A0   54 41 53 4D 20 20 20 20 20 20 20 13 00 00 00 00     TASM       .....
  4135.      0B0   00 00 00 00 00 00 27 63 B5 12 BE 02 00 00 00 00     ......'c5.>.....
  4136.      0C0   E5 52 49 56 45 20 20 20 44 20 20 20 00 00 00 00     eRIVE   D   ....
  4137.      0D0   00 00 00 00 00 00 09 0F 38 13 9A 26 12 C0 05 00     ........8..&.@..
  4138.      0E0   55 54 49 4C 20 20 20 20 20 20 20 13 00 00 00 00     UTIL       .....
  4139.      0F0   00 00 00 00 00 00 31 AC 9B 12 66 01 00 00 00 00     ......1,..f.....
  4140.      100   48 4D 41 56 20 20 20 20 20 20 20 13 00 00 00 00     HMAV       .....
  4141.      110   00 00 00 00 00 00 D6 AE 9B 12 A2 01 00 00 00 00     ......V...".....
  4142.      120   4D 49 53 43 20 20 20 20 20 20 20 13 00 00 00 00     MISC       .....
  4143.      130   00 00 00 00 00 00 3A 7D CB 12 FD 08 00 00 00 00     ......:}K.}.....
  4144.      140   47 41 4D 45 53 20 20 20 20 20 20 13 00 00 00 00     GAMES      .....
  4145.  
  4146. -LOOK-   Drive C:\     bits=8  tab=8  line=?       [F1]:HELP       [Alt+F1]:MENU
  4147. ================================================================================
  4148.  
  4149.                                   Figure 21-2
  4150.  
  4151.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  81
  4152.  
  4153.  
  4154.  
  4155.    21.3 PATCH Anything on a Disk - [F4]
  4156.  
  4157.    You can patch disks without regard to logical or physical file structure.
  4158.    This capability should be used with caution, as it is quite possible to
  4159.    make a disk unusable by patching the wrong byte(s).  The first part of the
  4160.    disk (before cluster 0002) contains formatting and space allocation
  4161.    information, and is the most sensitive area.  Therefore, EDDY will warn you
  4162.    and ask for confirmation before patching there.
  4163.  
  4164.    If this capability worries you, see the next section.
  4165.  
  4166.    !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
  4167.    WARNING!  USE GREAT CARE WITH SECTOR PATCHING ON "COMPRESSED" OR "EXTENDED"
  4168.    DRIVES -- I.E., DEVICES CREATED AND MANAGED BY DOUBLESPACE, STACKER, AND
  4169.    SIMILAR PRODUCTS.  PATCHING FILES STORED ON THOSE DISKS IS PERFECTLY SAFE,
  4170.    HOWEVER.  SEE SECTION 21.1 FOR MORE INFORMATION.
  4171.    !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
  4172.  
  4173.    21.4 That's Too Dangerous!
  4174.  
  4175.    These very powerful features can be extremely dangerous in the hands of an
  4176.    inexperienced user, or worse, someone who is intent on doing damage.  For
  4177.    this reason, some users prefer not to have all the capabilities readily
  4178.    available, especially on machines that may be used by more than one person.
  4179.  
  4180.    By creating a customized version of EDDY, you can PERMANENTLY disable the
  4181.    absolute sector patching feature.  Just answer "n" when the question:
  4182.                "Allow disk PATCHing by sector in new EDDY (y/n)?"
  4183.    is asked, and the customized version will have this feature disabled.  If
  4184.    you answer "y", you can change ANYTHING on a disk, including format data.
  4185.  
  4186.    Even if you customize again, using the disabled EDDY.COM as the master
  4187.    copy, sector patching cannot be re-enabled.  Your original copy of EDDY.COM
  4188.    (or EDDY.OLD, after customizing), will still do sector patching, however,
  4189.    so it should be kept safely tucked away where only you can get to it.
  4190.  
  4191.  
  4192.    21.5 FIND Strings Anywhere on a Disk - [Alt+f]
  4193.  
  4194.    The FIND command works the same as with a file.  Refer to Section 16.
  4195.  
  4196.  
  4197.  
  4198.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  82
  4199.  
  4200.  
  4201.    22. Working With Disk-Image Data
  4202.  
  4203.    You can copy entire disks -- boot sector, FAT, and all -- for backup or
  4204.    other purposes.  Some of the reasons you might want to do this are
  4205.    described below.
  4206.  
  4207.    You can also copy selected parts of a disk, which is primarily useful for
  4208.    data recovery purposes in situations where other methods fail.
  4209.  
  4210.    These functions are not available when LOOKing at remote (network) drives.
  4211.  
  4212.  
  4213.    22.1 COPY Disk Image - [Shift+F5]
  4214.  
  4215.    To copy an entire disk to a file, move the cursor to the "Drive" line of
  4216.    the display and press [Shift+F5].  The target directory must be on a
  4217.    separate disk, which must be larger than the disk being copied.
  4218.  
  4219.    The resulting disk-image file will be named "DRIVE.{x}", where "x" is the
  4220.    letter of the drive that was copied.  If a file with this name already
  4221.    exists in the target directory, you'll get a warning message and EDDY will
  4222.    let you decide whether to proceed or not.  If you proceed, the existing
  4223.    file will be overwritten.
  4224.  
  4225.    This file will be 4 bytes longer than the disk being copied (6 bytes if
  4226.    it's a hard disk).  EDDY writes the sector size and no. of sectors of the
  4227.    source disk at the beginning of the file, for checking compatibility if
  4228.    EDDY is used to restore the file to a disk (see next section).  If you need
  4229.    a file that is an exact image of your disk (i.e., doesn't have these extra
  4230.    bytes), use EDDY's PATCH command to delete the first 4 (or 6) bytes.
  4231.  
  4232.    This feature will not work with copy-protection schemes that use non-DOS
  4233.    formats for some or all parts of the disk.  Hidden files, non-standard
  4234.    directory structures, and unique boot programs are no problem, however.
  4235.  
  4236.    "That's interesting", you say, "but why would I want to do that?"
  4237.  
  4238.    There are several possible uses for this feature:
  4239.  
  4240.    a.  Upload/Download Entire Disks
  4241.  
  4242.    Sending entire disks electronically is difficult without EDDY.  If you have
  4243.    a disk you'd like to transmit via modem, use disk-image copying.
  4244.  
  4245.    Then you can compress the resulting "DRIVE.{x}" file, and transmit.  (For
  4246.    maximum compression, use a newly-formatted disk to create your original.)
  4247.    Make sure the receiver has a copy of EDDY, so that he can rebuild the disk
  4248.    as described in Section 22.2.
  4249.  
  4250.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  83
  4251.  
  4252.  
  4253.  
  4254.    b.  Make Multiple Disk Copies Quickly
  4255.  
  4256.    Another use for this feature is in making multiple copies of a single disk.
  4257.    Using EDDY to do a disk-image copy and then doing repeated disk-image
  4258.    restores, as described in Section 22.2 below, is a lot faster than
  4259.    repeating DOS's "diskcopy" several times.  It's particularly effective if
  4260.    you copy the disk image to a RAM disk.
  4261.  
  4262.    c.  Reduce Disks Needed for Backup
  4263.  
  4264.    A lot of software packages have a LOT of disks (Borland C++ comes to mind).
  4265.    Common sense tells us we should make backup copies of these disks, in case
  4266.    the originals go bad someday (There's ANOTHER 11 disks to store!).
  4267.  
  4268.    With EDDY, you can copy the original disks to image files, compress them
  4269.    with PKZIP or whatever, and copy two (sometimes 3) of those compressed
  4270.    files to one high-density disk.  You've just cut your backup disk count at
  4271.    least in half.
  4272.  
  4273.    If you ever need the backup, just uncompress the file for the disk you
  4274.    need, then use EDDY's disk-image restore, and you're ready to go.
  4275.  
  4276.    d.  No-Hassle Hard Disk Backup
  4277.  
  4278.    If you have two hard disks, you can use disk-image copying to backup the
  4279.    smaller on the larger -- and it's MUCH faster than other methods.  I
  4280.    routinely backup my laptop's disk to an external hard disk.  It takes about
  4281.    6 minutes, with NO disk swapping or other manual intervention,for a 20 MB
  4282.    hard disk.  And there are NO floppies to store and keep track of.
  4283.  
  4284.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  84
  4285.  
  4286.  
  4287.  
  4288.    22.2 Disk-Image Restore - [Shift+F5]
  4289.  
  4290.    This is the command that makes disk-image copying, described above, so
  4291.    useful.  This is how you rebuild identical-to-the-original, fully
  4292.    functional disks from the disk-image files.
  4293.  
  4294.    Unlike the commands described in Section 21, [Shift+F5] is used in EDIT
  4295.    mode.  It writes a file previously created with EDDY's disk-image copy
  4296.    capability to an entire physical disk, overwriting everything, including
  4297.    format, boot and file allocation information on the target disk.  The
  4298.    result is an exact copy of the disk originally used to create the file.
  4299.  
  4300.    When this command is used, the display will show "Copy image" next to the
  4301.    file involved.  The actual copying will be done only when you enter UPDATE,
  4302.    by pressing [Enter] as normal from EDIT.  Since the entire target disk will
  4303.    be overwritten by this operation, [Shift+F5] cannot be used if any other
  4304.    COPY or MOVE operations are pending.
  4305.  
  4306.    EDDY checks the disk format of the target disk against the information
  4307.    saved from the original disk.  If there is any difference, or if the file
  4308.    size has been changed since it was created, the restore will not proceed.
  4309.  
  4310.  
  4311.    22.3  COPY Selected Disk Areas
  4312.  
  4313.    This capability is particulary useful for recovering lost or damaged data
  4314.    when other methods fail.  This section describes the commands available to
  4315.    copy raw, disk-image data selectively.
  4316.  
  4317.    With these commands, you may copy all or parts of the DOS "system" area
  4318.    (the boot sector, FAT, root directory and any "hidden" sectors that may be
  4319.    part of your disk's format), or portions of the "data" area, where your
  4320.    files are -- or were -- stored.
  4321.  
  4322.    The resulting disk-image file will be named "SECTORS.{x}", where "x" is the
  4323.    letter of the drive that was copied.  If a file with this name already
  4324.    exists in the target directory, you'll get a warning message and EDDY will
  4325.    give you a choice as to how you wish to proceed: either by overwriting the
  4326.    existing file or appending the new data to it.
  4327.  
  4328.    To COPY, you must first "mark" the areas desired.  This process is
  4329.    different, depending on which part of the disk is involved.  Marking is
  4330.    described in the next two sections.
  4331.  
  4332.    Once you have selected the data you want to COPY, press [Enter] to start
  4333.    the COPY process. This is further described in Section 22.3.4.
  4334.  
  4335.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  85
  4336.  
  4337.  
  4338.  
  4339.    22.3.1  Mark Sectors (System Area) - [m]
  4340.  
  4341.    In the system area, EDDY treats the data as three logical groups:  the boot
  4342.    sector, plus any "hidden" sectors that may be present following it; the
  4343.    File Allocation Table(s); and the root directory.
  4344.  
  4345.    You may select any or all of these to be copied to the SECTORS.{x} file, by
  4346.    positioning the LOOK display anywhere within the system area (e.g., by
  4347.    pressing [Home], [Home] to move to the boot sector) and then pressing [m]
  4348.    (for "mark").  To "UNDO" marking of data previously selected, press [F2].
  4349.  
  4350.    EDDY will ask which of the logical groups you wish to include in the COPY
  4351.    process.  You will also be asked if you want to include "system area
  4352.    descriptions" along with the copied data.  If you choose to do so, a brief
  4353.    description will be placed in the file at the beginning of each logical
  4354.    data group, making it easy to identify which part of the data follows.
  4355.  
  4356.  
  4357.    22.3.2  Mark Clusters (Data Area) - [m]
  4358.  
  4359.    Clusters to be copied are marked by moving the LOOK display to the cluster
  4360.    desired, and pressing [m].  If no clusters are currently marked, the single
  4361.    displayed cluster will be marked.  If one or more clusters are already
  4362.    marked, the displayed cluster, plus all the clusters between it and the
  4363.    currently-marked clusters will be marked.  Thus, the marked area is always
  4364.    a contiguous set of clusters.
  4365.  
  4366.    Only areas of the disk which are formatted for file storage, i.e., cluster
  4367.    2 and beyond, can be marked in this way.  Lower-numbered sectors (boot
  4368.    sector, FAT, root directory, etc.) may be copied as described in the
  4369.    preceding section.
  4370.  
  4371.    Pressing [F2] (the "Undo" key) unmarks any clusters previously marked.
  4372.  
  4373.  
  4374.    22.3.3  Jump to Marked Area - [Alt+m]
  4375.  
  4376.    If you press [Alt+m], the display will move to the first marked sector or
  4377.    cluster, if any, unless it is already displayed.  In the latter case, if
  4378.    there are more marked clusters, the display will move to the last one.
  4379.    [Alt+m] has no effect if there are no marked areas, or if the entire disk
  4380.    is marked.
  4381.  
  4382.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  86
  4383.  
  4384.  
  4385.  
  4386.    22.3.4  COPY Marked Area - [Enter]
  4387.  
  4388.    When you have defined the portion of the disk you want to copy, by marking
  4389.    it, press [Enter].  After you confirm -- as with other update-type
  4390.    operations -- by pressing [Enter] again, the area you have selected will be
  4391.    copied to the target directory.
  4392.  
  4393.    If both the system area and the data area are marked, both will be copied.
  4394.  
  4395.    After copying is complete, EDDY unmarks all marked areas and remains in
  4396.    LOOK mode.  You may mark additional areas as desired, and copy those areas
  4397.    as well.  This may be repeated as often as you like (as long as there is
  4398.    enough space in the target).
  4399.  
  4400.    As long as you do not return to EDIT, all data copied will be added to the
  4401.    end of the data in the "SECTORS.{x}" file.  This allows you to build that
  4402.    file without respect to the order of clusters on the disk.
  4403.  
  4404.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  87
  4405.  
  4406.  
  4407.  
  4408.    22.4  Data Recovery
  4409.  
  4410.    When you accidentally delete a file, there are many excellent products to
  4411.    help you recover your data.  With luck, your file was allocated to contig-
  4412.    uous disk clusters, its directory entry has not been re-used, and no part
  4413.    of it has been overwritten.  In this case, and even some more complicated,
  4414.    these programs can often recover your file automatically.  If this solves
  4415.    your problem, congratulations!  There's nothing easier.
  4416.  
  4417.    However, normally Mr. Murphy has made his contribution by the time you
  4418.    realize you have a problem.  In this situation, EDDY offers facilities to
  4419.    assist you in recovering your data as easily as possible, and SAFELY!
  4420.  
  4421.    The job is made a little easier by some of the commands provided by EDDY.
  4422.    It is safe because all writes are to the target disk, which normally is
  4423.    physically separate from the one containing your data (although you may
  4424.    override this if you choose).  Thus, there is no chance of making things
  4425.    worse, by erroneously patching FATs or directories, or by copying data you
  4426.    are trying to recover on top of data you will want to recover later.
  4427.  
  4428.    The steps for file recovery are...
  4429.  
  4430.    1.  Set your working directory to the directory which used to contain the
  4431.        file which had the data you want to recover.  Move to the "Drive X:
  4432.        is..." line and press [F3].  Then press [Alt+w] to move to the area of
  4433.        the disk containing the working directory.  Continue with Step 2.
  4434.  
  4435.        If the directory has been deleted too, start with the (former) parent
  4436.        directory as your working directory, and use Steps 2 and 3 to move to
  4437.        the disk area containing the deleted directory information.  Then begin
  4438.        with Step 2 from there.
  4439.  
  4440.    2.  Move the display until the line containing your deleted filename (or
  4441.        directory) is at the top of the display.  Only the first byte of the
  4442.        filename will be different:  that byte will be either "E5" or "05" hex;
  4443.        the rest of the name will be unchanged (Note that there is no "."
  4444.        between the name and extension parts).
  4445.  
  4446.        If you'd like a clear display of the directory entry at the top of the
  4447.        display, press [Alt+d].  This can be particularly useful if there are
  4448.        several entries that might be the one you're looking for, or if the
  4449.        name was only one byte long, because you may be able to identify the
  4450.        correct entry by the former size, date, time and/or attributes.
  4451.  
  4452.        If you don't find the filename in the first cluster of the directory,
  4453.        press [Alt+n] to move to the next cluster allocated to the directory,
  4454.        and continue looking for the filename.
  4455.  
  4456.        If you can't find the filename, go to Step 4, below.
  4457.  
  4458.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  88
  4459.  
  4460.  
  4461.  
  4462.    3.  When you have the filename at the top of the screen, press [Alt+s], to
  4463.        display the starting cluster of the deleted file.  If the data looks
  4464.        like what you expected to find, proceed to Step 5.
  4465.  
  4466.        If the data there doesn't look like it belongs to that file, the
  4467.        cluster has probably been re-used by DOS to store another file.  In
  4468.        this case, continue with Step 4.
  4469.  
  4470.    4.  This step is needed when you have to do things the hard way -- when
  4471.        directory entries or data file space has been re-used, and things are
  4472.        not so easy to find.
  4473.  
  4474.        The task is to identify the first cluster containing data belonging to
  4475.        your file.  If you know what the data looked like, you may be able to
  4476.        locate it by using the FIND command to locate some known string.
  4477.  
  4478.        Otherwise, you'll have to scan through the clusters until you find one
  4479.        that contains likely-looking data.  This is not QUITE so hard as it
  4480.        might be, because EDDY provides you with a way of looking only at
  4481.        clusters which are currently unallocated, which is where any data from
  4482.        deleted files will be found.  (But see note at bottom of this page.)
  4483.        Use [Alt+u] to look at the unallocated clusters, one after another.
  4484.        This is still tedious, but at least it's better than deciphering the
  4485.        FAT to locate these clusters.
  4486.  
  4487.        When you've found the cluster you want to start recovering, proceed to
  4488.        the next step.
  4489.  
  4490.    5.  Mark the selected cluster, using [m].
  4491.  
  4492.    6.  Look at the next cluster.  If it looks like the next part of the file,
  4493.        mark it, too.  Repeat this step until the current cluster looks like
  4494.        it's from another file, or from this one, but out of sequence.
  4495.  
  4496.    7.  Write the marked cluster(s), by pressing [Enter].
  4497.  
  4498.    8.  Find the next cluster that looks like it logically follows the last one
  4499.        written, using FIND or [Alt+u], as appropriate (refer to Step 4 for an
  4500.        explanation of these).
  4501.  
  4502.    9.  Repeat steps 5 - 8 until you feel you have all the data from your file
  4503.        (or as much of it as is left, if other files have overwritten some of
  4504.        the clusters previously used by your file).
  4505.  
  4506.    10. Your data will be found in the "SECTORS.{x}" file ("x" is the drive
  4507.        where your data was stored) in the target directory.
  4508.  
  4509.    NOTE:  Some implementations of DOS do not de-allocate clusters when a file
  4510.    is deleted, but rather wait until the space is needed and then do a
  4511.    "garbage collection".  This makes recovery of a deleted file MUCH easier,
  4512.    as the cluster allocation chain remains intact.  Just restore the first
  4513.    byte of the filename in the directory and Voila!, there's your file.
  4514.  
  4515.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  89
  4516.  
  4517.  
  4518.  
  4519.    23. Directory Optimization
  4520.  
  4521.    There are three main reasons for changing the order of directory entries on
  4522.    disk:  to improve access speed, to free wasted disk space, and/or to allow
  4523.    directory information to be presented in some non-standard sequence that's
  4524.    unique to a particular application or user's preference.
  4525.  
  4526.         Access Speed
  4527.         ------------
  4528.         When DOS needs to access a particular file or subdirectory, it
  4529.         does a sequential search from the top of the directory, until it
  4530.         either finds the entry it's looking for, a never-used directory
  4531.         slot, or the end of the directory.  Clearly, if the entry wanted
  4532.         is near the beginning, and there are no directory slots present
  4533.         that are marked as "deleted", it'll be found quicker.
  4534.  
  4535.         Disk Space
  4536.         ----------
  4537.         Directories may grow as large as necessary to hold as many files
  4538.         as are placed in them, up to the limit of available disk space --
  4539.         except for the root directory, which has a size fixed at format-
  4540.         ting time.  Once they have grown, they NEVER shrink, even if you
  4541.         delete all the files in them.  The only way they get smaller is
  4542.         when the entire directory is deleted -- OR use EDDY to erase
  4543.         deleted entries and free the associated space (directory packing).
  4544.  
  4545.         Non-standard Sequences
  4546.         ----------------------
  4547.         Many utilities offer a variety of sequences for sorting directo-
  4548.         ries:  typically filename, extension, size or timestamp.  However,
  4549.         sometimes there's a need to put directories in an arbitrary
  4550.         sequence, which can't be handled by the usual sorting utilities.
  4551.         This might be to get the directories in the desired order for a
  4552.         disk optimizer, or just because you prefer to see them listed
  4553.         that way.  EDDY lets you put things in any order you please, by
  4554.         using the "Shuffle" command (see Section 23.2).
  4555.  
  4556.    !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
  4557.    WARNING!  DO NOT USE DIRECTORY OPTIMIZATION ON "COMPRESSED" OR "EXTENDED"
  4558.    DRIVES -- I.E., DEVICES CREATED AND MANAGED BY DOUBLESPACE, STACKER, AND
  4559.    SIMILAR PRODUCTS.  SEE SECTION 21.1 FOR MORE INFORMATION.
  4560.    !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
  4561.  
  4562.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  90
  4563.  
  4564.  
  4565.  
  4566.    23.1 Sorting a Directory
  4567.  
  4568.    Directories are normally sorted for display purposes only (as described in
  4569.    Section 1.4.2) to group files in ways -- by name, date, etc.  -- that make
  4570.    it easier to work with them.  Usually, displaying this way is enough, and
  4571.    there's no need to keep the sequence permanently on disk.
  4572.  
  4573.    When you do want to make the sequence permanent, however, just press
  4574.    [Shift] at the same time as you press the regular sorting commands; e.g.,
  4575.    press [Alt+Shift+n] for sorting by name, [Alt+Shift+d] for sorting by date,
  4576.    etc.  -- except [Alt+Shift+u] has no effect.  When the directory has been
  4577.    sorted by using the shifted commands, the letter for the sequence code at
  4578.    the bottom of the screen will blink.
  4579.  
  4580.    The blinking sequence code indicates that when you UPDATE, the directory
  4581.    can be rewritten to disk in that sequence.  After all file-related UPDATE
  4582.    actions -- copy, move, delete, rename, etc.  -- have been done, the
  4583.    message...
  4584.                       Write sorted directory to disk (y/n)?
  4585.    ...will appear, and EDDY will wait for your reply.  If you answer "y", the
  4586.    rewrite process will begin.
  4587.  
  4588.    If the current directory display includes only some of the files in the
  4589.    directory, due to a file specification used (e.g., "*.DOC"), or attribute
  4590.    or timestamp filtering, then the entries for those files will be rewritten
  4591.    first, before the remaining entries in the directory.  The result will be a
  4592.    directory display with two, separately sorted parts
  4593.  
  4594.    Any entries marked as "erased" by DOS will be moved to the end of the
  4595.    directory, to minimize time wasted by DOS in searching through them when
  4596.    using the directory later.
  4597.  
  4598.    For a way to eliminate this wasted time altogether, refer to Section 23.3.
  4599.  
  4600.    Before starting the rewrite, a check is made to be sure no files are
  4601.    currently open in the directory.  Rewriting with open files is likely to
  4602.    cause directory corruption, as DOS maintains pointers to absolute disk
  4603.    locations for data about files that are open, and rewriting will probably
  4604.    move that data during the process.
  4605.  
  4606.    EDDY uses some undocumented data structures within DOS to check for open
  4607.    files.  If EDDY finds data there that doesn't look valid, and therefore is
  4608.    unable to check for open files, this message...
  4609.                    Unsure if files open. Sorting not attempted
  4610.    ...will be displayed.
  4611.  
  4612.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  91
  4613.  
  4614.  
  4615.  
  4616.    23.2 Shuffling a Directory - [Alt+F6]
  4617.  
  4618.    EDDY lets you arrange your directories in any order you wish*.  Rather than
  4619.    sorting in the standard ways  -- name, size, etc. -- you may move the
  4620.    directory entries around to suit your own preferences, and then write them
  4621.    permanently in that sequence.
  4622.  
  4623.    This is useful to improve access speed to frequently-used directories and
  4624.    files, by placing them at the beginning of their respective directories.
  4625.  
  4626.    Shuffling is accomplished as follows:
  4627.  
  4628.    1.  Move the cursor to the directory or file you wish to move, and press
  4629.        [Alt+F6].  The action tag "Shuffle" will appear next to that entry.
  4630.  
  4631.    2.  Move the cursor to the entry located where you want the tagged entry to
  4632.        be placed, and press [Alt+F6] again.  The tagged entry will be moved to
  4633.        the position immediately after the current entry.
  4634.  
  4635.    When one or more entries have been shuffled, the sequence code shown at the
  4636.    bottom of the screen will change to a blinking "?".  If you UPDATE, the
  4637.    directory will be rewritten in the order it is displayed, and after the
  4638.    UPDATE the indicated sequence will be "U" (unsorted).
  4639.  
  4640.  
  4641.    23.3 Packing a Directory
  4642.  
  4643.    Erased directory entries are placed at the end of the directory by the
  4644.    rewrite process.  However, they still occupy space and they still waste
  4645.    search time when a file is "Not found" (this can become significant with
  4646.    long "PATH statements).  On the plus side, an erased entry MAY be used to
  4647.    recover a file deleted by mistake.
  4648.  
  4649.    If you are sure you won't need to recover any files deleted in a directory,
  4650.    then use EDDY to get rid of them.  Depending on how many there are, you may
  4651.    get some additional free space on your disk, as EDDY will shrink the
  4652.    directory to the minimum size needed to hold the entries remaining.  You
  4653.    will also eliminate time wasted in searching through them.
  4654.  
  4655.    When the directory rewrite process begins, if any directory slots are
  4656.    marked as "deleted", EDDY will ask...
  4657.                     Erase "deleted" directory entries (y/n)?
  4658.    If you answer "y", the directory will be "packed" as it is rewritten.
  4659.  
  4660.    ---------------------------------------------------------------------------
  4661.  
  4662.    * NOTE:  There are two exceptions to "any order":  the '.' and '..' entries
  4663.    at the beginning of a subdirectory can't be moved, nor can the DOS system
  4664.    files (IBMBIO.COM, IBMDOS.COM or similar name) at the beginning of a root
  4665.    directory be moved.
  4666.  
  4667.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  92
  4668.  
  4669.  
  4670.  
  4671.    23.4 Had a Problem?  Don't Panic!
  4672.  
  4673.    This process has been exhaustively tested by the author and many users,
  4674.    without any problems.  However, some of us are hesitant (read
  4675.    "intelligent") about using programs that mess with our disks in
  4676.    non-standard ways.  Therefore, the following information is offered.
  4677.  
  4678.    Sorting and rewriting directories cannot be done using the standard DOS
  4679.    application services.  EDDY handles this by writing directly to the
  4680.    directories, and using DOS services where available.  No non-standard
  4681.    manipulation of the File Allocation Table (FAT) is involved.
  4682.  
  4683.    The steps involved in sorting and rewriting a subdirectory are:
  4684.  
  4685.    1.  Set the "directory" attribute OFF in the subdirectory's entry in the
  4686.        working directory.  This makes DOS think the subdirectory is a file.
  4687.  
  4688.    2.  Read the "file", using standard DOS services.
  4689.  
  4690.    3.  Sort the directory entries in memory, and rewrite the "file"
  4691.        (packing it if appropriate), again using standard DOS services.
  4692.  
  4693.    4.  Turn the "directory" attribute back ON in the directory.
  4694.  
  4695.    If there is a problem with any of the above steps (e.g., a power failure
  4696.    during the update), recovery is straightforward.
  4697.  
  4698.    - If the subdirectory is still shown as a directory entry in its parent
  4699.    directory, there's no problem.
  4700.  
  4701.    - If there was a problem with step 4, the subdirectory will be shown as a
  4702.    "file" (i.e., no "directory" attribute) in the parent directory, with a
  4703.    length of zero.  Don't panic!  There's only one little bit that has to be
  4704.    changed.  To fix this problem, LOOK at the disk to display the raw
  4705.    directory data.  Move the display until the entry for the "file" is at the
  4706.    top, and PATCH offset 0Bh to "10h".  Your directory is now restored.  Exit
  4707.    from LOOK, and you'll see the result.
  4708.  
  4709.  
  4710.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  93
  4711.  
  4712.  
  4713.  
  4714.    24.  UPDATE Mode - [Enter], [^Enter]
  4715.  
  4716.    When you want to apply to disk the changes you have indicated in EDIT mode,
  4717.    press [Enter] to go to UPDATE mode.  EDDY will display the net change in
  4718.    number of bytes used on disk which will result from your update.  A "+"
  4719.    means more bytes will be used, and a "-" means some bytes will be freed.
  4720.  
  4721.    Before actually writing anything to disk, EDDY will ask you to confirm that
  4722.    you want to proceed, by pressing [Enter] again.  This is to avoid writing
  4723.    to disk before you are ready because of touching a key by mistake.
  4724.  
  4725.    If you use [^Enter] to start the UPDATE, EDDY will ask you whether to put
  4726.    the current date/time on files copied.  UPDATE normally -- after [Enter] --
  4727.    leaves the timestamp unchanged on a file that has been copied.  If you use
  4728.    [^Enter] instead, EDDY will ask whether you want to do this or not.
  4729.  
  4730.    (If you have customized EDDY as described in Section 25, EDDY assumes you
  4731.    are familiar with the program; in this case, no question is asked, and the
  4732.    timestamp on copied files will be set to the current DOS values.)
  4733.  
  4734.  
  4735.    24.1 Applying changes
  4736.  
  4737.    As each file is processed, its EDIT mode display line is displayed,
  4738.    allowing you to monitor UPDATE's progress through the directory.  If a
  4739.    file's display line is not yet shown, nothing has been done to that file.
  4740.  
  4741.    After each file has been processed, EDDY checks to see if you have pressed
  4742.    a key.  If so, updating will be suspended.  All processing for the file
  4743.    being worked on will be completed, but no work will start on the next file.
  4744.  
  4745.    When UPDATE has been suspended, it may be resumed by pressing [Enter] (or
  4746.    [^Enter], if you want to change the way timestamps on any further copied
  4747.    files are treated).  If you press [Esc], EDDY returns to EDIT mode, leaving
  4748.    intact any requests for changes not yet processed by UPDATE; these changes
  4749.    may be undone if desired, or you may UPDATE them later.
  4750.  
  4751.    UPDATE does Deletes and Destroys first.  After deletions, a second pass is
  4752.    made to apply any other requested changes.
  4753.  
  4754.    If there are errors during UPDATE processing, (read or write problems,
  4755.    e.g.) EDDY reports the error as indicated by DOS and suspends the UPDATE at
  4756.    that point.  You may resume the UPDATE or return to EDIT, as you choose.
  4757.  
  4758.    After a successful UPDATE, pressing any key returns to EDIT.  If the key is
  4759.    one of EDDY's commands, it will be acted on.
  4760.  
  4761.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  94
  4762.  
  4763.  
  4764.  
  4765.    After an UPDATE, any files moved or deleted from the working directory will
  4766.    be shown grouped together at the end of the directory display, rather than
  4767.    in their original locations before the UPDATE.
  4768.  
  4769.    If there are more files in the directory than can be displayed by EDDY,
  4770.    files deleted or moved will not be shown; instead, additional files from
  4771.    the working directory will be displayed.
  4772.  
  4773.  
  4774.    24.2 Print a Record of Your Changes - [Alt+p]
  4775.  
  4776.    While EDDY is waiting for confirmation to proceed with an UPDATE -- i.e.,
  4777.    after you have pressed [Enter] once, and before you press it a second time
  4778.    -- you may tell EDDY to print the changes as they are made.
  4779.  
  4780.    Press [Alt+p] to print.  Pressing [Alt+p] again turns printing off.
  4781.  
  4782.    You may also turn printing on during the UPDATE by pressing [Alt+p].
  4783.    Printing will begin with the next change.
  4784.  
  4785.  
  4786.    24.3 Target Capacity Check
  4787.  
  4788.    EDDY checks to be sure there is enough room on the target directory disk to
  4789.    satisfy any COPY or MOVE requests you may have made before starting the
  4790.    update.  If there is, EDDY proceeds as described above.
  4791.  
  4792.    However, when there is not enough room, you'll see the following messages:
  4793.  
  4794.                               Not enough room on X:
  4795.                               Bytes needed: nnnnnnn
  4796.                               Can't COPY/MOVE files
  4797.  
  4798.    "X:" is the target disk drive.  The number of additional bytes needed is
  4799.    calculated from the file sizes in the working directory and the cluster
  4800.    size of the target directory disk, and takes into account that EDDY does
  4801.    deletions first while updating.
  4802.  
  4803.    To make room on the target disk, you must delete or move files occupying
  4804.    clusters equal to the total "bytes needed".  (Most files' sizes are not
  4805.    even cluster multiples, but the space allocated to them by DOS always is.)
  4806.  
  4807.    When there are changes requested in addition to the copies and/or moves,
  4808.    this message will also be displayed:
  4809.  
  4810.                           [Enter] to apply other UPDATEs
  4811.  
  4812.    If you decide to go ahead, requested changes other than copies and moves
  4813.    will be done, but files selected for copying or moving will be ignored.
  4814.  
  4815.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  95
  4816.  
  4817.  
  4818.  
  4819.    There are some situations in which the displayed summary of changes in disk
  4820.    space used may be inaccurate.  In some cases, EDDY may run out of disk
  4821.    space at some intermediate stage during COPY/MOVE operations, even though
  4822.    the summary indicates there is enough space.  This may happen in two
  4823.    situations.  First, when all of these conditions occur:
  4824.  
  4825.     1) Two or more files, for which there are files with the same name in the
  4826.        target directory, are being copied or moved.
  4827.     2) Some of the files from the working directory use more clusters than
  4828.        their namesakes in the target directory, and some use fewer.
  4829.     3) The big files are copied or moved before the small ones.
  4830.  
  4831.    In this case, all free space could be filled before space is freed by the
  4832.    copying or moving of the smaller files.  If this happens, just resume the
  4833.    UPDATE by pressing [Enter].  When the UPDATE has completed, the files that
  4834.    were not copied will still be tagged.  UPDATE again to copy those.
  4835.  
  4836.    A second situation that can cause the computed space requirement to be
  4837.    inaccurate is when copying is done with TAB expansion (see Section 11.5.1).
  4838.    TAB expansion (using [Alt+2] thru [Alt+8]) results in a file larger than
  4839.    the original.  As EDDY does not scan the file first to count the actual
  4840.    number of TABs in the file and calculate the number of additional bytes
  4841.    that will result from the TAB expansion, it is possible to run out of space
  4842.    on the target disk.
  4843.  
  4844.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  96
  4845.  
  4846.  
  4847.  
  4848.    24.4 Error Recovery
  4849.  
  4850.    24.4.1 Data Errors
  4851.  
  4852.    If a read error is encountered on a disk during a COPY or MOVE operation,
  4853.    EDDY offers three alternatives:
  4854.  
  4855.      1 - Write a sector of "#" bytes in the new copy of the file in place of
  4856.          the sector that cannot be read.  The new copy will be the same length
  4857.          as the original.  All data which was in disk sectors that did not
  4858.          have have a problem will of course be copied intact.
  4859.  
  4860.          To see where the errors were, you might do a FIND on a string with
  4861.          several "#"s in a row.  (EDDY writes a full sector, minus 4 bytes, of
  4862.          "#"s -- the "#"s are preceded and followed by a CR,LF pair.)
  4863.  
  4864.      2 - Skip the sector entirely, and write the next good block immediately
  4865.          after the previous block in the new copy. This obviously results in
  4866.          a new copy that is shorter than the original.
  4867.  
  4868.          When this alternative is used, there is nothing in the new file to
  4869.          indicate where sectors have been deleted.
  4870.  
  4871.      3 - Abort the copy/move process. In this case the DOS error code will be
  4872.          displayed, and no new copy will be produced. EDDY will continue with
  4873.          any other updates that may have been requested for other files.
  4874.  
  4875.    After an update where choice 1 or 2 has been selected, the message
  4876.    displayed for the file(s) involved will be "copied(?)" or "moved(?)", to
  4877.    indicate that the new copy is not exactly the same as the original.  Also,
  4878.    the date and time on the new copy will always be the current date and time
  4879.    in this case.
  4880.  
  4881.    If multiple errors occur on a file, all will be treated in the same way,
  4882.    according to the alternative you select when the first was encountered.
  4883.  
  4884.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  97
  4885.  
  4886.  
  4887.  
  4888.    24.4.2 Cross-linked Files
  4889.  
  4890.    When EDDY copies a file, the number of bytes actually read is compared to
  4891.    the file size contained in the file's directory entry.  If there is a
  4892.    difference, you will see the message: "Size shown in directory incorrect".
  4893.  
  4894.    The most probable cause of this is that you have two files which have
  4895.    somehow had the same disk cluster assigned to them by DOS (This is NOT a
  4896.    problem caused by EDDY!).  You can verify that this is the case by running
  4897.    CHKDSK; CHKDSK will tell you which cluster is the overworked one, and would
  4898.    also normally tell you that there are some "lost allocation units".  Under-
  4899.    standing the situation is fairly straightforward; finding the cause is not!
  4900.  
  4901.    What this means is that you have the beginning of both files intact, up to
  4902.    the cluster where they are cross-linked.  After that cluster, you have the
  4903.    rest of ONE of those files.  The rest of the other file, minus whatever was
  4904.    stored in the problem cluster, is most likely to be found in the "lost
  4905.    allocation units".
  4906.  
  4907.    EDDY doesn't offer any special capabilities to help you, beyond providing a
  4908.    way to look at file contents and truncate files as required, but the
  4909.    following discussion is offered in the hope that it may help someone
  4910.    confronted with this problem for the first time.
  4911.  
  4912.    If you have this problem, to salvage what you can, do the following:
  4913.  
  4914.      1 - Copy both files to the target directory.  One of them will be correct
  4915.          (call this one "GOODFILE" for purposes of this discussion).  You'll
  4916.          probably have to LOOK at them or try running them to figure out which
  4917.          one that is.
  4918.  
  4919.      2 - Run CHKDSK /F to convert the "lost" bits to a file.  CHKDSK will give
  4920.          it a name like "FILE000n.CHK".  Multiple files will be created if
  4921.          there is more than one group ("chain") of lost clusters.
  4922.  
  4923.      3 - If the file that was NOT correct after this step (call this one
  4924.          "BADFILE") is a text file, LOOK at the ".CHK" file(s) to see if you
  4925.          can identify some data that appears to belong with BADFILE.  If so,
  4926.          rename that .CHK file appropriately (say, "BADFILE.MOR").  If BADFILE
  4927.          is not a text file, there's probably not much you can do, except
  4928.          proceed to step 6.
  4929.  
  4930.      4 - You may then use your editor, word processor, EDDY or whatever to
  4931.          chop off the erroneous data at the end of BADFILE.  (This is data
  4932.          that actually duplicates some of the correct data belonging to
  4933.          GOODFILE).
  4934.  
  4935.      5 - Then, using DOS's COPY command (or other tools as appropriate),
  4936.          rejoin the two parts -- e.g., COPY BADFILE+BADFILE.MOR  BETTER.FIL.
  4937.  
  4938.      6 - Delete the remaining .CHK files after examining them to be sure the
  4939.          don't contain anything useful.
  4940.  
  4941.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  98
  4942.  
  4943.  
  4944.  
  4945.    25.  EDDY's Default Settings are Lousy!
  4946.  
  4947.    You can't please all of the people all of the time.  With this in mind,
  4948.    EDDY is designed to be easy to "tailor" to your taste in several ways.
  4949.  
  4950.    EDDY can be customized, creating a new copy of EDDY.COM with the various
  4951.    colors, options, controls, etc.  set the way you like them.
  4952.  
  4953.  
  4954.    25.1 Customizing - "EDDY/0"
  4955.  
  4956.    To customize, execute EDDY with option /0 (i.e., enter "EDDY/0") and use
  4957.    the normal commands available in the program to set the options, etc.  When
  4958.    you have everything set up the way you want it, press [Enter].
  4959.  
  4960.    You'll see a display of the various features that may be customized, to use
  4961.    as a final checklist.  Press any key to clear this display, and then tell
  4962.    EDDY to create a new copy of itself with the settings you have selected, by
  4963.    pressing [Enter] or [^Enter].  Normally, EDDY puts the current date/time on
  4964.    the new copy; if you want the old timestamp on the new copy, use [^Enter].
  4965.  
  4966.    When you customize, your working directory must contain the version of
  4967.    EDDY that is to be customized (which must be the same as the version that's
  4968.    executing), and it must be named "EDDY.COM".
  4969.  
  4970.    The customizable features, and the ways to set them, are:
  4971.  
  4972.     1. Screen colors (see Section 25.2)
  4973.         - use [Alt+r]  (note: [Alt+r] valid only during customizing)
  4974.  
  4975.     2. Options (see Section 2.3)
  4976.         - select via [Alt+o] or from the command line
  4977.  
  4978.     3. Synchronization Controls (see Section 10)
  4979.         - select via [Alt+c]
  4980.  
  4981.     4. Sort sequence (see Section 1.4.2)
  4982.         - use [Alt+d], [Alt+e], [Alt+h], [Alt+n], [Alt+s], [Alt+u] or [Alt+i]
  4983.  
  4984.           NOTE: If you use any of the above sort commands, then sorting
  4985.           by date/time when using a timestamp filter is not automatic.
  4986.  
  4987.     5. Default action for [Alt+w] and [Alt+t] (see Section 5.1.1)
  4988.  
  4989.     6. Default point-and-shoot command (see Section 14.2.2)
  4990.         - use [Shift+F8], and enter desired command
  4991.  
  4992.     7. Attribute filter (see Section 17.1)
  4993.         - use [Alt+a], or from the command line, "+xx"
  4994.  
  4995.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  99
  4996.  
  4997.  
  4998.  
  4999.     8. Command key used with left mouse button (see Section 2.1.2a)
  5000.         - use [Alt+m], then press key for desired command
  5001.  
  5002.     9. Left- or right-handed mouse (see Section 2.1.2b)
  5003.         - use [Alt+m], then press right mouse button
  5004.  
  5005.    10. Mouse sensitivity (see Section 2.1.2c)
  5006.         - use [Alt+Shift+m], then move left or right
  5007.  
  5008.    11. LOOK mode bit-stripping, line-wrapping and TAB default settings
  5009.         (see Section 8.2.3)
  5010.         - in LOOK mode, use [Alt+b], [Alt+l] and [Alt+number], respectively
  5011.  
  5012.    12. Hex/ASCII toggle key (see Section 8.2.1a)
  5013.         - in LOOK mode, [Shift+Tab] allows selection of the key to be used
  5014.  
  5015.    13. Auto-scrolling speed (see Section 8.2.2)
  5016.         - in LOOK mode, use [^PgUp]/[^PgDn]
  5017.  
  5018.    14. Enable/disable absolute sector patching feature (see Section 21.4)
  5019.         - answer question: "Allow disk PATCHing by sector in new EDDY (y/n)?"
  5020.  
  5021.    15. Identify compressed disks permanently (see Section 21.1)
  5022.         - answer question: "Is <x:> a 'compressed disk'...(y/n)?"
  5023.  
  5024.    When customizing, no editing, copying, patching or other changes to the
  5025.    disk can be made.  The only purpose for this mode is to let you set things
  5026.    the way you want them, and then make a copy of EDDY with those settings.
  5027.  
  5028.    The customized version will be written to the working directory, and will
  5029.    be named "EDDY.COM".  The original copy of EDDY will be renamed "EDDY.OLD".
  5030.  
  5031.    During the process of creating the new, customized EDDY.COM, there could be
  5032.    error conditions such as bad spots on the disk which cause the process to
  5033.    abort; if this occurs, you may see an error message referring to "EDDY.NEW"
  5034.    (e.g., "Error writing EDDY.NEW").  EDDY.NEW is the name given to the new
  5035.    copy during the customizing process, until it has completed without error;
  5036.    only then are the files renamed as described in the preceding paragraph.
  5037.  
  5038.    The messages "Where's EDDY.COM?" or "Incompatible EDDY.COM", mean EDDY.COM
  5039.    is not in your working directory, or the version that's there is not the
  5040.    same as the version that's executing, respectively.
  5041.  
  5042.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page 100
  5043.  
  5044.  
  5045.  
  5046.    25.2 Rainbow Selection - [Alt+r]
  5047.  
  5048.    In "customize" mode only, the [Alt+r] command is available to allow you to
  5049.    select the color combination for EDDY that best suits your monitor and
  5050.    preferences.  [Alt+r] displays the following:
  5051.  
  5052.                              SELECT SCREEN COLORS
  5053.  
  5054.                            For next color on  Press
  5055.                            -----------------  -----
  5056.                            Headings            [h]
  5057.                            Text body           [t]
  5058.                            Cursor line         [c]
  5059.                            Window borders      [w]
  5060.                         [Alt+F1] for menu/HELP colors
  5061.                          (Upper case for prev color)
  5062.  
  5063.                        [Enter] when you like the colors
  5064.  
  5065.    Pressing any of the indicated letters changes the color of the corres-
  5066.    ponding part of the display, cycling through all the available colors as
  5067.    you press repeatedly.  Upper case letters cycle in the opposite direction.
  5068.  
  5069.    When the colors are the way you want them, press [Enter].  Those colors
  5070.    will then be used with the new, customized copy of EDDY you create.
  5071.  
  5072.  
  5073.    25.3 Customizing by PATCHing
  5074.  
  5075.    It is also possible to customize some features of EDDY by using EDDY's
  5076.    PATCH capability -- [F4] -- directly on EDDY.COM.
  5077.  
  5078.    25.3.1 DOS Prompt String
  5079.  
  5080.    EDDY modifies the DOS prompt to end with "Exit>" when you use the DOS Gate-
  5081.    way, [F9], to remind you that an EXIT command is eventually needed.  If you
  5082.    don't like this, or if you'd prefer some other display, PATCH EDDY.COM
  5083.    beginning at offset 00000008 (hex).  In an unmodified copy of EDDY, you'll
  5084.    see the string "Exit$g" in this location, followed by a hex byte of "00".
  5085.  
  5086.    If you want no change to the DOS prompt, change byte 00000008 to hex "00".
  5087.    If you want to use a different prompt, you may PATCH up to six bytes
  5088.    (00000008 - 0000000D) with the string you want to use.  Following the last
  5089.    byte of your string, PATCH one byte to "00" hex, to terminate the string.
  5090.  
  5091.    25.3.2  Data Error Indicator
  5092.  
  5093.    When EDDY finds data errors on a disk during a COPY operation, the bad
  5094.    sectors may be written out to contain all "#" bytes.  If you PATCH the byte
  5095.    in EDDY.COM at offset 00000006 to any other value, that value will be used
  5096.    as the bad sector filler character.
  5097.  
  5098.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page 101
  5099.  
  5100.  
  5101.  
  5102.    25.3.3  I Don't Mind a Little Flicker
  5103.  
  5104.    EDDY displays RAM (in LOOK mode) with a constant update of the screen
  5105.    between keystrokes, in order to allow you to watch what's really happening
  5106.    there; i.e., some locations, such as the system clock, are constantly
  5107.    changing.  However, updating with this frequency causes a lot of screen
  5108.    flicker if a Color Graphics Adapter is used.  Most people find this very
  5109.    annoying, and so this "real time" display isn't normally done with a CGA.
  5110.  
  5111.    However, if you REALLY want to try this, PATCH the byte in EDDY.COM at
  5112.    offset 00000007 to anything other than "00" hex.  Have an aspirin ready.
  5113.  
  5114.  
  5115.    25.3.4  Don't Confuse [F3] and [Enter]
  5116.  
  5117.    If you don't like the fact that [Enter] acts like [F3] when there are no
  5118.    pending changes for UPDATE (as described at the end of Section 8.1), patch
  5119.    the byte at 00000005 to anything other than "00" hex.
  5120.  
  5121.  
  5122.    25.4  How Do I Get Rid of the *$#^&! "UNREGISTERED" Message?
  5123.  
  5124.    That's an easy one: Register!  See Section 26 for details.
  5125.  
  5126.    If you have already registered a version earlier than EDDY v.7a, drop me a
  5127.    line and I'll send you the latest version, registered in your name.
  5128.  
  5129.    If you have registered EDDY v.7a or later, you may patch the registration
  5130.    data into the new copy of EDDY, as follows:
  5131.  
  5132.         1.  Press [F3] to LOOK at your registered copy of EDDY.COM.  Write
  5133.         down the value found in the 6 bytes of data beginning at offset
  5134.         00000025 (00000054 in version 7a, 00000055 in 7b).
  5135.  
  5136.         2.  Press [F4] to PATCH your new copy of EDDY.COM, beginning at offset
  5137.         00000010, with your name -- exactly as it appears when you QUIT from
  5138.         your old, registered version.
  5139.  
  5140.         3.  PATCH the new copy of EDDY.COM beginning at offset 00000025 with
  5141.         the 6 bytes of data you found in step 1.
  5142.  
  5143.    Your new copy of EDDY will now display the "Registered to:  (your name)"
  5144.    message when you run it.  If not, you have probably made an error in one of
  5145.    the above steps.  (The name used in step 2 must correspond to the 6 bytes
  5146.    used in step 3; otherwise, "UNREGISTERED" will be displayed.)
  5147.  
  5148.    If you prefer not to bother with these steps, I'll be glad to send you (the
  5149.    registered user) the latest version, registered in your name, for the cost
  5150.    of handling and distribution (see Section 26.1 for current prices).
  5151.  
  5152.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page 102
  5153.  
  5154.  
  5155.  
  5156.    26.  Registration
  5157.  
  5158.    If you have registered an earlier version of EDDY, refer to Section 25.4.
  5159.  
  5160.    If you find EDDY to be useful and satisfactory after a reasonable trial
  5161.    period, and you continue to use EDDY, then you should register, either by
  5162.    credit card (see Section 26.2) or by sending your registration fee (see
  5163.    Section 26.1) to the address shown when EDDY exits.
  5164.  
  5165.    The low registration fee purchases a license, as described in Section 26.4.
  5166.    It also entitles you to technical support as described in Section 27, to
  5167.    receive one free upgrade, subsequent updates at cost of handling and
  5168.    distribution (see Section 26.1), and to the satisfaction of knowing you
  5169.    have done "the right thing".
  5170.  
  5171.    Also, the "Register" button on the screen will no longer appear, and EDDY
  5172.    stops "nagging" you when you customize or do multiple updates.
  5173.  
  5174.    When you register, you will receive the latest version, registered in your
  5175.    name.  This does NOT count as your free upgrade; you are still entitled to
  5176.    to a free upgrade at a later date, as new releases become available.
  5177.  
  5178.    EDDY will (gently) remind you if your copy is not yet registered.  However,
  5179.    all versions, registered or not, are fully functional -- not "crippled" in
  5180.    any way.  All features are available to everyone.
  5181.  
  5182.  
  5183.    26.1 Pricing
  5184.  
  5185.    "Users" means the number of people, on a network or separately, who may be
  5186.    using the program simultaneously.
  5187.  
  5188.     1 -  5 users ............................ each $25.00
  5189.  
  5190.     6 - 20 users ............................ each $20.00
  5191.  
  5192.    21 - 99 users ............................ each $15.00
  5193.  
  5194.    100 or more users ........................ each $10.00
  5195.  
  5196.  
  5197.    Updates available to registered users at 20% of the above prices (e.g.,
  5198.    $5.00 for a single copy), to cover postage and handling costs.
  5199.  
  5200.    All prices are expressed in US dollars.
  5201.  
  5202.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page 103
  5203.  
  5204.  
  5205.  
  5206.    26.2 Registering by Credit Card
  5207.  
  5208.    CREDIT CARD ORDERS ONLY
  5209.    =======================
  5210.    You can order with MasterCharge, Visa, American Express, or Discover from
  5211.    PsL -- Public (software) Library -- by calling 800-2424-PsL or 713-524-6394
  5212.    or by FAX to 713-524-6398 or by CIS Email to 71355,470.  You can also mail
  5213.    credit card orders to PsL at P.O.Box 35705, Houston, TX 77235-5705.
  5214.  
  5215.    Please refer to item number 10740 when ordering by credit card.
  5216.  
  5217.    THE ABOVE PHONE/FAX NUMBERS ARE FOR ORDERS ONLY
  5218.    ===============================================
  5219.    Please DO NOT send credit card orders directly to the author.  This will
  5220.    only delay shipment.  I am not able to process credit card orders, and
  5221.    must send them back to you with a request to resubmit through PsL.
  5222.  
  5223.    Any questions about the status of the shipment of the order, refunds,
  5224.    registration options, product details, technical support, volume discounts,
  5225.    dealer pricing, site licenses, etc, must be directed to John Scofield, at
  5226.    the address shown on the logo when you exit from EDDY.
  5227.  
  5228.    To insure that you get the latest version, PsL will notify me via email the
  5229.    day of your order,  and I'll ship the latest version directly to you.
  5230.  
  5231.  
  5232.    26.3 Registering by Mail
  5233.  
  5234.    To register by mail, you may use the form provided by PRINTing the last
  5235.    page of this file (EDDY.DOC), or by running the "REGISTER.BAT" file.
  5236.  
  5237.    You may also ask EDDY to print a copy of the form, by pressing [Alt+z].
  5238.  
  5239.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page 104
  5240.  
  5241.  
  5242.    26.4 "The License"
  5243.  
  5244.    Registration purchases a license for the right to use the program -- NOT
  5245.    the program itself.  One registration fee entitles you to one ACTIVE copy
  5246.    of the program at any time.
  5247.  
  5248.    Here are the terms of the license:
  5249.  
  5250.        THIS SOFTWARE AND THE DISK ON WHICH IT IS  CONTAINED ARE LICENSED TO
  5251.        YOU, FOR YOUR OWN USE.  THIS IS  COPYRIGHTED  SOFTWARE.  YOU ARE NOT
  5252.        OBTAINING  TITLE TO THE SOFTWARE OR ANY  COPYRIGHT  RIGHTS.  YOU MAY
  5253.        NOT  SUBLICENSE, RENT, LEASE, CONVEY, MODIFY,  TRANSLATE, CONVERT TO
  5254.        ANOTHER PROGRAMMING LANGUAGE, DECOMPILE, OR DISASSEMBLE THE SOFTWARE
  5255.        FOR ANY PURPOSE.
  5256.  
  5257.        YOU MAY MAKE AS MANY  COPIES OF THIS  SOFTWARE AS YOU NEED.  YOU MAY
  5258.        USE THIS  SOFTWARE ON  MORE THAN ONE  COMPUTER, PROVIDED THERE IS NO
  5259.        IT WILL BE USED  SIMULTANEOUSLY  ON MORE THAN ONE  COMPUTER.  IF YOU
  5260.        NEED TO USE THE SOFTWARE  ON MORE THAN ONE  COMPUTER  SIMULTANEOUSLY,
  5261.        PLEASE CONTACT THE  AUTHOR.  SITE LICENSES ARE AVAILABLE.
  5262.  
  5263.    Thanks to Steven Hudgik for the form and most of the wording used in the
  5264.    license and warranty disclaimers. His book, "Writing & Marketing Shareware"
  5265.    (Windcrest Books, 1992), is highly recommended.
  5266.  
  5267.  
  5268.    26.5 Pass A Copy to a Friend ("de-personalized")
  5269.  
  5270.    If you would like to pass a copy of EDDY along for someone else to try,
  5271.    that would be great!  However, some users feel uncomfortable in giving out
  5272.    a copy that shows their name every time it runs.  If you would like to
  5273.    "de-personalize" a copy before passing it on, just patch EDDY.COM at
  5274.    offset 00000025 hex to 00 hex (or any other value different from what's
  5275.    currently there);  that copy will become an "UNREGISTERED" copy.
  5276.  
  5277.  
  5278.    26.6 EDDY is NOT Free and NOT Public Domain!
  5279.  
  5280.    Although EDDY is distributed in this way, it is not free. It is also
  5281.    protected by copyright, and has not been released into the public domain.
  5282.  
  5283.    EDDY is shareware.  This means you are free to make copies, pass copies on
  5284.    to anyone else who may be interested, and take a reasonable time to "try
  5285.    before you buy" (I consider something on the order of 30 days to be
  5286.    "reasonable").  You are, however, expected to honor the "buy" obligation if
  5287.    the "try" is satisfactory.
  5288.  
  5289.    Copies of the program may not be sold for more than the cost of the medium
  5290.    they are copied on, plus reasonable handling charges.
  5291.  
  5292.    EDDY and this User's Manual may be copied ad lib provided the author's
  5293.    copyright notice and disclaimers of warranty are reproduced in full.
  5294.  
  5295.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page 105
  5296.  
  5297.  
  5298.  
  5299.    27.  Distribution and Support / Disclaimer
  5300.  
  5301.    If you have a problem with EDDY, I'll do my best to help.  However, before
  5302.    we get to the specifics of such help, please consider the following:
  5303.  
  5304.    If you have not yet done so, please read the "DISCLAIMER" that appears both
  5305.    below and at the beginning of this file.  In part, this disclaimer means
  5306.    there is no representation that EDDY will do ANYTHING, whether or not the
  5307.    author or the documentation states or implies that it will.  Similarly,
  5308.    there is no representation that the program will NOT do anything harmful or
  5309.    annoying.  Whatever it may do or not do, the author is not responsible for
  5310.    the results.  Any person using EDDY bears all risk as to the quality and
  5311.    performance of the software, and the consequences of using it.
  5312.  
  5313.                        DISCLAIMER - PLEASE READ CAREFULLY!
  5314.    ===========================================================================
  5315.       BY USING THIS PROGRAM, EDDY ("the software"), YOU ACCEPT THESE TERMS:
  5316.  
  5317.         THE  SOFTWARE  AND  ITS  ASSOCIATED  DOCUMENTATION  ARE SUPPLIED
  5318.         "AS-IS", WITHOUT ANY WARRANTY OF ANY KIND.  THE AUTHOR EXPRESSLY
  5319.         AND SPECIFICALLY  DISCLAIMS ALL  REPRESENTATIONS AND  WARRANTIES
  5320.         RELATING TO THE SOFTWARE, WHETHER EXPRESS OR IMPLIED, INCLUDING,
  5321.         BUT  NOT   LIMITED  TO,  ANY  IMPLIED   WARRANTIES  OF  QUALITY,
  5322.         PERFORMANCE,   MERCHANTABILITY   OR  FITNESS  FOR  A  PARTICULAR
  5323.         PURPOSE.   NEITHER  THE  AUTHOR  NOR  ANYONE  ELSE WHO  HAS BEEN
  5324.         INVOLVED IN THE DELIVERY OF THE SOFTWARE SHALL BE LIABLE FOR ANY
  5325.         DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL  DAMAGES
  5326.         ARISING OUT OF THE USE OR  INABILITY TO USE THE  SOFTWARE OR FOR
  5327.         ANY LOSS  OR  DAMAGE  OF ANY  NATURE  CAUSED  TO  ANY  PERSON OR
  5328.         PROPERTY  AS A RESULT  OF THE USE OF THE  SOFTWARE,  EVEN IF THE
  5329.         AUTHOR HAS BEEN SPECIFICALLY  ADVISED OF THE POSSIBILITY OF SUCH
  5330.         DAMAGES OR CLAIMS.  THE AUTHOR IS NOT RESPONSIBLE FOR ANY COSTS,
  5331.         INCLUDING,  BUT NOT  LIMITED TO,  THOSE INCURRED  AS A RESULT OF
  5332.         LOST PROFITS  OR REVENUE,  LOSS OF USE OF THE SOFTWARE,  LOSS OF
  5333.         DATA,  THE  COSTS  OF  RECOVERING  ANY  SOFTWARE  OR  DATA,   OR
  5334.         THIRD-PARTY  CLAIMS.  IN NO EVENT  SHALL THE  AUTHOR'S LIABILITY
  5335.         FOR ANY DAMAGES TO YOU OR  ANY OTHER PARTY EVER EXCEED THE PRICE
  5336.         PAID FOR THE LICENSE TO USE THE SOFTWARE, REGARDLESS OF THE FORM
  5337.         OF THE CLAIM.
  5338.  
  5339.    ===========================================================================
  5340.  
  5341.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page 106
  5342.  
  5343.  
  5344.  
  5345.    27.1 Technical Support
  5346.  
  5347.    Technical support is guaranteed to be available to any registered user for
  5348.    at least six months from the date of registration.  In practice, support is
  5349.    available for an unlimited time; only if circumstances (e.g., illness) make
  5350.    it impractical to continue would support ever cease.
  5351.  
  5352.    In the unlikely event you (as a registered user) have a problem with EDDY
  5353.    (not a bug, surely!), if you take the trouble to report it, I'll try to
  5354.    solve it.  And I'll get back to you with a fix, if possible.
  5355.  
  5356.    With any problem report, please include the following information:
  5357.  
  5358.     1. Version number of your copy of EDDY (as shown on the logo
  5359.        which is displayed when you exit from EDDY)
  5360.  
  5361.     2. Level of MS- or PC-DOS you are using
  5362.  
  5363.     3. Any resident programs being used -
  5364.        - listings or copies of AUTOEXEC.BAT and CONFIG.SYS are very helpful!
  5365.  
  5366.     4. As complete a description of the problem as possible -
  5367.        - what did you enter on the command line?
  5368.        - what commands did you use just before the problem occurred?
  5369.             (the last 4-5 keystrokes, if possible)
  5370.        - how was EDDY's output different from what you expected?
  5371.        - IMPORTANT! what were your settings for EDDY's...
  5372.             ...options?
  5373.             ...Synchronization controls?
  5374.             ...attribute or timestamp filters?
  5375.        - what customization, if any, have you selected (per Section 25)?
  5376.        - [PrtSc] screen printouts before and after the problem (if possible)
  5377.        - any other information that seems relevant
  5378.  
  5379.     5. Hardware used
  5380.       (please provide the information from the following list that seems
  5381.       related to your problem) -
  5382.        - computer: brand name & model
  5383.        - memory size, and whether Expanded or Extended Memory installed
  5384.        - monitor: color or B/W, brand name & model, screen size (if not 25x80)
  5385.        - display adapter: Mono, CGA, EGA, VGA or ???; brand name & model
  5386.        - mouse, if any: number of buttons, brand name & model
  5387.        - working directory disk drive: type & size, brand name & model
  5388.        - target directory disk drive: type & size, brand name & model
  5389.        - any other hardware
  5390.  
  5391.     6. Your name, address and phone number
  5392.  
  5393.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page 107
  5394.  
  5395.  
  5396.  
  5397.    27.2  How Can I Get in Touch With You?
  5398.  
  5399.    I move around a LOT;  both throughout the US and in various places around
  5400.    the world.  Mail eventually reaches me, but it sometimes takes a while
  5401.    longer than people expect.  Please try to be patient -- I WILL respond.
  5402.  
  5403.    Please send all correspondence to:  John Scofield
  5404.                                        117 West Harrison Bldg.
  5405.                                        6th floor, Dept. S-678
  5406.                                        Chicago, IL 60605 USA
  5407.  
  5408.    This address is a forwarding service.  If quicker contact/response is
  5409.    needed, and you have access to a modem, you may also reach me via
  5410.    CompuServe:  70162,2357.  If you have access to the Internet, e-mail may
  5411.    be sent to me at:
  5412.                                 scofield@ACM.org
  5413.  
  5414.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page 108
  5415.  
  5416.  
  5417.  
  5418.    27.3  Where Can I Find the Latest Version?
  5419.  
  5420.    EDDY is available on CompuServe (IBMSYS, LIB 6) and many other BBSs,
  5421.    including the ASP Hub Network BBSs, which offer it as a free download.
  5422.  
  5423.    In an effort to make it easier for you to obtain your favorite software,
  5424.    the latest updates of many programs written by ASP members can be found on
  5425.    the BBSs listed below. These BBSs are members of the ASP Hub Network (AHN).
  5426.  
  5427.    Zone 1 - East Coast USA
  5428.         North-East Coast                      Mid-East Coast
  5429.    [Site #1]                             [Site #2]
  5430.         The Consultant BBS                    The Break RBBS <East>
  5431.         Jay Caplan                            Bruce Jackson
  5432.         P.O. Box 8571                         4660 Whitaker PL
  5433.         New York NY 10116-4655                Dale City, VA 22193-3011
  5434.         Data1) 718-837-3236                   Data1) 703-680-9269
  5435.                                               Data2) 703-551-0000
  5436.  
  5437.    Zone 2 - North Mid-USA               Zone 3 - Southern Mid-USA
  5438.    [Site #3]                             [Site #4]
  5439.         The Twilight Zone                     The DataExchange BBS
  5440.         John Hrusovszky                       Don Morris
  5441.         1119 E. Main St                       119 Herring St.
  5442.         Auburndale, WI 54412                  Leesville, LA 71446
  5443.         Data1) 715-652-2758                   Data1) 318-239-2122
  5444.  
  5445.    Zone 4 - West Coast USA
  5446.    [Site #5]                            [Site #6]
  5447.         Attention to Details BBS             Space BBS
  5448.         Clint Bradford                       Owen Hawkins
  5449.         5085 Trail Canyon Dr                 PO Box X
  5450.         Mira Loma CA 91752                   Menlo Park, CA 94026
  5451.         Data1) 909-681-6221                  Data1) 415-323-4398 (ASP Files)
  5452.                                              Data2) 415-323-4193 (Other Files)
  5453.  
  5454.    Zone 5 - Canada
  5455.    [Site #7]
  5456.         Knightec BBS
  5457.         Phil Knight
  5458.         35 Robb Blvd #6
  5459.         Orangeville, ONT L9W 3L1
  5460.         Data1) 519-940-0007
  5461.  
  5462.    These BBSs are bound by special agreement with the ASP.  In the case of a
  5463.    dispute contact the ASP Omsbudsman.
  5464.  
  5465.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page 109
  5466.  
  5467.  
  5468.  
  5469.    27.4  A.S.P. Ombudsman
  5470.  
  5471.    This program is produced by a member of the Association of Shareware
  5472.    Professionals (ASP).  ASP wants to make sure that the shareware principle
  5473.    works for you.  If you are unable to resolve a shareware-related problem
  5474.    with an ASP member by contacting the member directly, ASP may be able to
  5475.    help.  The ASP Ombudsman can help you resolve a dispute or problem with an
  5476.    ASP member, but does not provide technical support for members' products.
  5477.    Please write to the ASP Ombudsman at 545 Grover Road, Muskegon, MI 49442-
  5478.    9427 or send a Compuserve message via CompuServe Mail to ASP Ombudsman
  5479.    70007,3536.
  5480.  
  5481.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  a1
  5482.  
  5483.  
  5484.  
  5485.                                    Appendix A
  5486.  
  5487.                                 Command Reference
  5488.  
  5489.  
  5490.     I. Function Keys, Shifted Function Keys
  5491.  
  5492.          [F1]            HELP
  5493.          [F2]            UNDO
  5494.          [F3]            LOOK at file, directory, disk or RAM
  5495.          [F4]            PATCH file, disk or RAM
  5496.          [F5]            tag file for COPY (EDIT)...
  5497.                          ...OR...COPY directory tree to file
  5498.          [F6]            tag file for MOVE
  5499.          [F7]            tag file for DELETE
  5500.          [F8]            Execute default point-n-shoot command
  5501.          [F9]            DOS gateway
  5502.          [F10]           QUIT, return to exit directory if selected
  5503.  
  5504.          [^F2] - [^F8]   Same as above, for all files
  5505.          [^F10]          Same as [F10]; if EGA/VGA, lines/screen unchanged
  5506.  
  5507.          [Alt+F1]        Display pull-down menus
  5508.          [Alt+F3]        LOOK at file in target directory
  5509.          [Alt+F6]        Shuffle directory entries
  5510.          [Alt+F7]        Logical DELETE (Ignore) - current file
  5511.          [Alt+^F7]       Logical DELETE (Ignore) - all files
  5512.          [Alt+F9]        Execute COM, EXE or BAT file
  5513.          [Alt+F10]       QUIT, exit to current working directory
  5514.  
  5515.          [Shift+F3]      Compare file's directory entries in work and target
  5516.          [Shift+^F3]     Compare all files' dir entries in work and target
  5517.          [Shift+F5]      Copy entire disk to file (disk-image copying)...
  5518.                          ...OR...copy image file to disk (disk-image restore)
  5519.          [Shift+F7]      DESTROY (overwrite file, then delete)
  5520.          [Shift+^F7]     DESTROY all files
  5521.          [Shift+F8]      Execute default point-n-shoot command
  5522.          [Shift+^F8]     Execute default point-n-shoot command on all files
  5523.          [Shift+F9]      Execute command defined in EDDY.USE on current file
  5524.          [Shift+^F9]     Execute command defined in EDDY.USE on all files
  5525.          [Shift+F10]     Set directory recall
  5526.          [Shift+^F10]    Recall directory
  5527.  
  5528.          [Alt+Shift+F3]  Compare current file's contents in working and target
  5529.  
  5530.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  a2
  5531.  
  5532.    II. [Alt]- and [Ctrl]-Shifted Keys
  5533.  
  5534.          [Alt+a]         ATTRIBUTE filtering (EDIT)...
  5535.                          ...OR...Truncate file after cursor (PATCH)
  5536.          [Alt+b]         Set bit-stripping default state (LOOK)...
  5537.                          ...OR...Truncate file before cursor (PATCH)...
  5538.                          ...OR...Copy with bit-stripping (EDIT)
  5539.          [Alt+c]         Synchronization CONTROL
  5540.          [Alt+d]         Sort by file DATE/time...
  5541.                          ...OR...Display directory entry (LOOK at disk)
  5542.          [Alt+Shift+d]   Sort by file DATE/time, rewrite after UPDATE
  5543.          [Alt+e]         Sort by file EXTENSION
  5544.          [Alt+Shift+e]   Same as [Alt+e], but rewrite after UPDATE
  5545.          [Alt+f]         FIND string in file
  5546.          [Alt+g]         Assign GLOBAL match character (FIND)
  5547.          [Alt+h]         Sort by file time (HOUR/minute)
  5548.          [Alt+Shift+h]   Same as [Alt+h], but rewrite after UPDATE
  5549.          [Alt+i]         INVERT display sequence
  5550.          [Alt+j]         Jump to disk cluster (LOOK at disk)
  5551.          [Alt+k]         Set "don't match" byte (FIND)
  5552.          [Alt+l]         Set line-wrapping default state (LOOK)
  5553.          [Alt+m]         Change command used for primary mouse key (EDIT); ...
  5554.                          ...OR...Jump to marked area (LOOK at disk)
  5555.          [Alt+Shift+m]   Adjust mouse sensitivity
  5556.          [Alt+n]         Sort by file NAME...
  5557.                          ...OR...Jump to NEXT cluster (LOOK at disk)
  5558.          [Alt+Shift+n]   Sort by file NAME, rewrite after UPDATE
  5559.          [Alt+o]         OPTION settings
  5560.          [Alt+p]         PRINT (directory, in EDIT; changes, in UPDATE; ...
  5561.                          ...OR...file, in LOOK)
  5562.          [Alt+Shift+p]   Send formfeed to printer
  5563.          [Alt+q]         Timestamp filtering (EDIT)
  5564.          [Alt+r]         REPLACE toggle (FIND)...
  5565.                          ...OR...Rainbow (color) selection, when customizing
  5566.                                  (with option /0)
  5567.          [Alt+s]         Sort by file SIZE...
  5568.                          ...OR...Jump to STARTING cluster
  5569.                                  (LOOK at disk)
  5570.          [Alt+Shift+s]   Sort by file SIZE, rewrite after UPDATE
  5571.          [Alt+t]         TARGET directory inquiry/change using tree or box...
  5572.                          ...OR...display TARGET directory (LOOK at disk)
  5573.          [Alt+Shift+t]   TARGET directory inquiry/change using dialog box
  5574.          [Alt+u]         Leave display UNSORTED...
  5575.                          ...OR...display UNALLOCATED cluster (LOOK at disk)
  5576.          [Alt+v]         VOLUME label addition or changing
  5577.          [Alt+Shift+v]   VOLUME label deletion
  5578.          [Alt+w]         WORKING directory change using tree or box...
  5579.                          ...OR...display WORKING directory (LOOK at disk)
  5580.          [Alt+Shift+w]   WORKING directory change using dialog box
  5581.          [Alt+x]         eXCHANGE working and target directories
  5582.          [Alt+y]         Delete bytes from beginning or end of file (PATCH)
  5583.          [Alt+z]         View registration info/Print registration form...
  5584.                          ...OR...Append ^Z to file (PATCH)
  5585.  
  5586.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  a3
  5587.  
  5588.  
  5589.  
  5590.          [^c]            interrupt repeating command
  5591.          [^f]            FIND string in all files
  5592.          [^n]            change attribute on all files to OFF
  5593.          [^v]            Volume serial number display/update
  5594.          [^w]            "Where's That File?"
  5595.          [^y]            change attribute on all files to ON
  5596.  
  5597.          [^letter]       from tree display or directory dialog box...
  5598.                          ...scan directory tree for drive indicated
  5599.  
  5600.          [^\]            select drive from list of valid drives
  5601.  
  5602.  
  5603.    III. Miscellaneous Keys
  5604.  
  5605.          [=]             Set file date and time to...
  5606.                          ...EDDY's timestamp if [Alt+equal] previously used...
  5607.                          ...otherwise, use current DOS date and time
  5608.          [Alt+equal]     Set EDDY's timestamp to date and time of...
  5609.                          ...current file or directory
  5610.          [Alt+minus]     Undo effect of preceding [Alt+equal]
  5611.  
  5612.          [+]             Toggle attribute ON/OFF
  5613.          [Tab]           Toggle hex/ASCII display or data entry format...
  5614.                          ...(LOOK, PATCH and FIND)
  5615.          [Shift+Tab]     Set new key for hex/ASCII toggle...
  5616.                          ...(LOOK, PATCH and FIND)
  5617.  
  5618.          [0]             TAB characters not expanded (LOOK)
  5619.          [1] - [8]       TABs expand to next "n"-byte boundary (LOOK)
  5620.          [Alt+0] - [Alt+8]   Same as [0]-[8], result is new default (LOOK)...
  5621.                          ...OR...Copy with TAB expansion (EDIT)
  5622.  
  5623.          [b]             BIT-stripping toggle (LOOK)
  5624.          [d]             Move ruler DOWN (LOOK)
  5625.          [e]             EGA/VGA lines-per-screen toggle (LOOK)
  5626.          [f]             Repeat previous FIND (LOOK)
  5627.          [j]             JUMP to new position in file (LOOK)
  5628.          [l]             LINE-wrapping toggle (LOOK)
  5629.          [m]             MARK area to be copied (LOOK at disk)
  5630.          [p]             Make hex display PRINTABLE (LOOK)
  5631.          [r]             RULER line display (LOOK)
  5632.          [s]             Speed-scrolling toggle
  5633.          [t]             Shift display 20 bytes right (LOOK)
  5634.          [T]             Shift display 20 bytes left (LOOK)
  5635.          [u]             Move ruler UP (LOOK)
  5636.          [w]             Display words, not bytes (LOOK)
  5637.          [W]             Display inverted words (LOOK)
  5638.  
  5639.          [BackSpace]     interrupt repeating command
  5640.          [ScrollLock]    Interrupt processing temporarily. Resume when...
  5641.                          ...[ScrollLock] is released.
  5642.  
  5643.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  b1
  5644.  
  5645.  
  5646.  
  5647.                                     Appendix B
  5648.  
  5649.  
  5650.                            What Does That Message Mean?
  5651.  
  5652.    The purpose of this Appendix is to explain some of EDDY's error and status
  5653.    messages which may not be completely self-explanatory or clear from their
  5654.    context.  Messages are listed alphabetically.
  5655.  
  5656.    When these messages are displayed on the screen, they are followed by a
  5657.    reminder that more information about why the message appeared and what, if
  5658.    anything, you should do about it, may be found in this Appendix.
  5659.  
  5660.    If you find some other messages EDDY produces that need clarification,
  5661.    please let me know, and I'll include them in the next update.
  5662.                           ------------------------------
  5663.  
  5664.    Can't adjust sensitivity
  5665.         An error has been returned by the mouse driver.  Probable cause is a
  5666.         non-Microsoft compatible mouse being used.
  5667.  
  5668.    Can't find COMMAND.COM
  5669.         After searching the DOS environment, EDDY has either failed to find
  5670.         the "COMSPEC" variable, which tells where to find COMMAND.COM, or has
  5671.         tried to find COMMAND.COM where COMSPEC said it was, but couldn't.
  5672.  
  5673.         You won't be able to do any DOS Gateway or Point-n-Shoot operations,
  5674.         but other EDDY commands will work correctly.  When you quit EDDY,
  5675.         though, you'll have a problem when DOS can't find COMMAND.COM either.
  5676.  
  5677.    Can't patch this file
  5678.         You have pressed [F4], but EDDY cannot get "write" access to the file.
  5679.         This is not just a read-only file; in that case, EDDY would ask first,
  5680.         and then remove the read-only status so that patching could proceed.
  5681.  
  5682.         This may occur on a network, if the file is part of a non-DOS file
  5683.         system, such as UNIX, and you don't have permission for write access.
  5684.  
  5685.    Directory is part of target path
  5686.         You can't move a directory to its "child", nor to any directory
  5687.         subordinate to it.  E.g., you can't move C:\UTIL to C:\UTIL\MISC; you
  5688.         could, however, move C:\UTIL\MISC to C:\ if you wished.
  5689.  
  5690.    Directory recall set
  5691.         You have pressed [Shift+F10], selecting the current working directory
  5692.         for possible "recall".  If you later press [Shift+^F10], this
  5693.         directory will again become the working directory.  If you press [F10]
  5694.         or [^F10], you will quit EDDY with this directory as the DOS default.
  5695.  
  5696.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  b2
  5697.  
  5698.  
  5699.  
  5700.    DOS version problem
  5701.         This message appears if you execute EDDY under a DOS version earlier
  5702.         than 2.0, or if you try to rename a subdirectory or sort/shuffle and
  5703.         rewrite a directory but are using a level of DOS earlier than 3.0.
  5704.  
  5705.    EDDY.AUX problem
  5706.         Much of EDDY's major functionality is stored in the EDDY.AUX file, as
  5707.         a set of 5 separate overlays.  If this file can't be located, is
  5708.         found to be corrupt, or is a different version than EDDY.COM, there
  5709.         really isn't much useful that can be accomplished.  Most times, you
  5710.         might just as well hit [F10].  However, in case you have EDDY.AUX
  5711.         tucked away in some non-normal directory, you can recover.  Make that
  5712.         your working directory, press [F1] (or any of a variety of other keys)
  5713.         and EDDY will discover EDDY.AUX and happily continue.
  5714.  
  5715.    File not found. [Ins] to rename.
  5716.         You probably pressed a key by mistake, causing EDDY to go into speed-
  5717.         search mode for a matching filename that wasn't there.  If what you
  5718.         really wanted to do was rename the file, either press [Ins] to turn on
  5719.         renaming for that file, or set Option /F ON for all files.
  5720.  
  5721.    Memory corrupted!
  5722.         When EDDY temporarily gives up control to DOS for Gateway or Point-n-
  5723.         Shoot functions, a checksum of EDDY's memory area is computed and
  5724.         recorded.  It is computed again when EDDY regains control.  If there's
  5725.         a difference, some process that has been executed outside of EDDY has
  5726.         written to memory that belongs to EDDY.  EDDY terminates immediately,
  5727.         without attempting to restore any paths, colors, fonts, etc.
  5728.  
  5729.    No target. Delete all (y/n)?
  5730.         You have set the Synchronization Controls to specify that the files
  5731.         in the target are to be compared with those in the working directory,
  5732.         and the result used to determine which files will be tagged for
  5733.         DELETE.  But there is currently no target directory.
  5734.  
  5735.    Not enough memory
  5736.         This may appear when trying to use the DOS Gateway or Point-n-Shoot
  5737.         functions, and there is not enough memory to load the requested
  5738.         program.  It may also occur if EDDY returns from executing one of
  5739.         these functions, and finds that there is not enough memory available
  5740.         to continue (and so EDDY terminates).
  5741.  
  5742.         You might also see this message when you try to rewrite a sorted
  5743.         directory to disk.  It means there isn't enough room in memory for all
  5744.         of the directory entries plus workspace for the sort process
  5745.  
  5746.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  b3
  5747.  
  5748.  
  5749.  
  5750.    Not supported for this disk
  5751.         There are several conditions that can produce this message:
  5752.         1. The disk is larger than 32 MB, and the version of DOS being used
  5753.            can't handle it.
  5754.         2. The disk is a remote drive, accessed on a network, and you are
  5755.            attempting some low-level operation, such as sector patching.
  5756.         3. EDDY has received conflicting data regarding the disk format.  The
  5757.            program always cross-checks this data by calling combinations of
  5758.            BIOS and DOS functions, so that all critical data is treated to a
  5759.            "second opinion".  If there is disagreement, no low-level access
  5760.            will be attempted by EDDY.
  5761.  
  5762.    Path name too long
  5763.         This one can really be puzzling (some users have reported it as a
  5764.         bug).  When you have a path with a long chain of subdirectories, EDDY
  5765.         may refuse to move to a directory, giving this message.  It means DOS
  5766.         can't get to the directory, even though it's there.  This can happen
  5767.         if you rename a directory with a longer name, and the resulting path
  5768.         is longer than 64 bytes.  It can be even more obscure if you are using
  5769.         a SUBST'ed disk, so that the path doesn't look too long; however, DOS
  5770.         uses the total effective length, after expanding the SUBST path.
  5771.  
  5772.    Press key for primary mouse button
  5773.         EDDY is waiting for you to select -- by pressing -- a key to define
  5774.         the command to be executed whenever you subsequently press the primary
  5775.         (normally, the left) mouse button.
  5776.  
  5777.    Same disk
  5778.         You have tried to copy, or prepare to copy, an entire disk, plus
  5779.         format information added by EDDY, to a file on that same disk -- 5
  5780.         quarts won't fit in a gallon jug.
  5781.  
  5782.    Size shown in directory incorrect
  5783.         Probable cross-linked file.  Refer to Section 24.4.2 of this document.
  5784.  
  5785.    Timestamp frozen
  5786.    Timestamp unfrozen
  5787.         When the timestamp is frozen, it will remain set to the same value,
  5788.         and that value will be used whenever [=] is pressed.  When it's
  5789.         unfrozen (or has never been frozen), the current DOS date and time
  5790.         will be used when [=] is pressed.
  5791.  
  5792.    EDDY v.7d User's Manual   Copyright (C) 1987-93 by John Scofield  page  b4
  5793.  
  5794.  
  5795.  
  5796.    Unable to complete directory move
  5797.         Refer to Section 12.4.2 of this document
  5798.  
  5799.    Unable to complete directory rewrite
  5800.         Refer to Section 23.4 of this document
  5801.  
  5802.    Unsure if files open. Sorting not attempted
  5803.         Refer to Section 23.1 of this document
  5804.  
  5805.    WARNING!  Memory allocation changed
  5806.         When EDDY temporarily gives up control to DOS for Gateway or Point-n-
  5807.         Shoot functions, the amount of free memory is recorded.  If the same
  5808.         amount of memory is not available when EDDY regains control, you've
  5809.         most likely run some program which has TSR'd (terminated and stayed
  5810.         resident).  Although this is not usually a problem that affects EDDY's
  5811.         operation, it will probably cause trouble when you finally quit, as
  5812.         there are likely to be "holes", or unusable areas in memory that can
  5813.         only be eliminated by rebooting.  If you can remove the TSR program by
  5814.         using the DOS Gateway, you should do so to avoid problems later.  If,
  5815.         however, so much memory has been taken that EDDY can't continue, you'll
  5816.         see "Not enough memory", and EDDY will terminate.
  5817.  
  5818.    EDDY Registration Form
  5819.  
  5820.                                                           Date ____________
  5821.     John Scofield
  5822.     117 West Harrison Bldg.
  5823.     6th floor, Dept. S-678
  5824.     Chicago, IL 60605
  5825.  
  5826.     Dear John:
  5827.  
  5828.     Please register me as another happy user of EDDY.  Here's my $25.00.
  5829.  
  5830.     I have version _____ of EDDY, which I got from ______________________
  5831.  
  5832.     ____________________________________________________________________ .
  5833.  
  5834.     (If you would give me some information about your system, it might
  5835.     help with trouble-shooting later on; also, I'm curious about what
  5836.     kind of hardware EDDY has worked successfully with.  Thank you.)
  5837.  
  5838.     I use a _____________________ PC, along with a ______________ monitor
  5839.  
  5840.     and a _____________________ video adapter.  I have ______K bytes of
  5841.  
  5842.     regular memory in my system.  I use MS-DOS/PC-DOS, level _____.
  5843.  
  5844.     My system also has (please check any that apply)...
  5845.  
  5846.         __  _____MB Hard disk, (brand/model ____________________________)
  5847.         __  5-1/4", 360 KB floppy drive     __  5-1/4", 1.2 MB floppy drive
  5848.         __  3-1/2", 720 KB floppy drive     __  3-1/2", 1.4 MB floppy drive
  5849.         __  Expanded memory (_____MB)       __  Extended memory (_____MB)
  5850.         __  A __-button mouse (brand, model _________________)
  5851.         __  A monitor bigger than 25x80. Mine has ___ lines & ___ columns
  5852.         __  Other: ______________________________________________________
  5853.  
  5854.  
  5855.     Yours truly,
  5856.  
  5857.  
  5858.     ____________________________ (name)
  5859.  
  5860.     ____________________________ (address)
  5861.  
  5862.     ____________________________
  5863.  
  5864.     ____________________________                      If you need a
  5865.                                                       receipt, please
  5866.     ____________________________ (phone no.)          check here: ___
  5867.  
  5868.     P.S.  I have the following comments or suggestions for EDDY:
  5869.  
  5870.  
  5871.  
  5872.  
  5873.  
  5874.     P.P.S.  I'd like to see updates to EDDY posted to ___________________
  5875.            BBS, if possible.  Its phone number is: (    )________________.
  5876.